CPU 412. Function. Programmable properties

Similar documents
General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory

100 ms. 30 µs; Time per I/O byte. 24 V DC No; Power supply via system power supply. Not relevant for 400 series (300 series set)

Product type designation. General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory

Product type designation. General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory

Parameterizable properties The S7 configuration as well as the properties and response of the CPUs can be parameterized using STEP 7:

General information. Supply voltage. Input current

CPU 319F-3 PN/DP. Page 1682 Mar 2008 Siemens ITS

Product type designation. General information. CiR - Configuration in RUN. Input current. Power loss. Memory

General information. Supply voltage. Input current

General information. Supply voltage. Input current

General information. Supply voltage. Input current

CPU 412H. Function. Parameterizable properties

6ES7151-8AB01-0AB0. 5/18/2011 Siemens Industry IA/DT/BT Service&S. siemens.com/ww/llisapi.dll?func=csl 1/10 ET200S, IM151-8 PN/DP CPU, 192 KB

SIMATIC S7-400, CPU KB WORKING MEMORY (384 KB CODE, 384 KB DATA) 1. INTERFACE MPI/DP 12 MBIT/S 2.IF PROFIBUS DP, 3.

Product type designation. General information. Supply voltage. Input current. Power losses

CPU 317F-2 DP. Page 1603 Mar 2008 Siemens ITS

Product type designation. General information. Supply voltage. Input current. Power loss

General information. Supply voltage. Input current

Supply voltage. Input current. Power loss. Memory. Battery. CPU processing times

SIPLUS CPU 313C-2DP. Function

Programming package STEP 7 V5.2 SP1 or higher with HSP 0126

General information. Supply voltage

Product type designation. General information. Supply voltage

Product type designation. General information. Supply voltage

General information. Engineering with. Supply voltage. Load voltage L+ Input current. Power losses. Memory. Work memory.

General information. Display. Control elements. Supply voltage

General information. Configuration control. Display. Control elements. Supply voltage

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

General information. Configuration control. Display. Control elements. Supply voltage

General information. Display. Control elements. Supply voltage

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

General information. Display. Control elements. Supply voltage

Product type designation

Product type designation. General information. Supply voltage. Input current

General information. Configuration control. Control elements. Supply voltage. Input current. Power. Power loss. Memory

SIMATIC PC-based controller

64 kbyte ; 64 KB / 21K instructions RAM (integrated) Yes ; 4 KB: bit memory, counter, times and data

General information. Supply voltage

PROFINET/Industrial Ethernet Controllers / Modular controllers / SIMATIC S7-400

Multi Panel options. SIMATIC WinAC MP 2/169

SIMATIC. ET 200S IM CPU Interface Module. Introduction. New features 2. Technical specifications 3. Product Information 06/2007 A5E

Data sheet CPU 315SN/PN ECO (315-4PN33)

CP ADVANCED. Function

Data sheet CPU 015PN (015-CEFPR01)

Data sheet CPU 015PN (015-CEFPR00)

Data sheet VIPA CPU 214PG (214-2BE03)

Data sheet CPU 315SN/NET (315-4NE12)

Data sheet SLIO CPU 015PN (015-CEFPR01)

Data sheet CPU 315SN/NET (315-4NE12)

Data sheet VIPA CPU 214NET PG (214-2BT13)

Data sheet CPU 315SB/DPM (315-2AG12)

Data sheet CPU 315SB/DPM (315-2AG12)

Data sheet VIPA CPU M13C (M13-CCF0000)

Data sheet CC 03, Commander Compact (603-1CC21)

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current

General information. Configuration control. Display. Control elements. Supply voltage

General information. Display. Supply voltage

General information. Display. Supply voltage

Data sheet CPU 013C (013-CCF0R00)

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

SIMATIC NET. S7-CPs for PROFIBUS. CP Extended for PROFIBUS. Manual Part B4

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

General information. Display. Supply voltage. Input current. Encoder supply. Output current

CPU 224. The compact high-performance CPU With 24 inputs/outputs on board Expandable with up to 7 expansion modules Design

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current

Data sheet VIPA CPU 115DP (115-6BL22)

General information. Display. Supply voltage. Input current

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

General information. Display. Supply voltage. Input current. Encoder supply. Output current. Power loss. Memory

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

Data sheet CPU 115 (115-6BL02)

General information Engineering with Programming package. Display with display

Commander compact. Commander compact Lines displays. System SLIO. System 100V. Lines displays Commander compact 603-1CC CC21.

Supply voltage. Input current. Encoder supply. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Output current

SIMATIC NET. S7-CPs for Industrial Ethernet CP Manual Part B3S. Release 02/2006 C79000 G8976 C201 03

Supply voltage. Input current. Encoder supply. Memory SIMATIC S7-200, CPU 221 COMPACT UNIT, DC POWER SUPPLY 6 DI DC/4 DO DC, 4 KB CODE/2 KB DATA,

SIMATIC NET. S7-CPs for Industrial Ethernet. CP Advanced. Manual Part B4A. Release 01/2007 C79000-G8976-C193-06

SIMATIC S Central processing units

S7-400 Automation System, CPU Specifications. S7-400 Automation System, CPU Specifications. Manual. Manual SIMATIC S Answers for industry.

TIM 3V- IE ADVANCED. Function

Siemens AG ES AH02-0AE0 6ES BH02-0AE0 6ES CH02-0AE0

STEP 7. Function. Page 1791 Mar 2008 Siemens ITS

System description SLIO

CPU 1512SP-1 PN (6ES7512-1DK00-0AB0) SIMATIC ET 200SP CPU 1512SP-1 PN (6ES7512-1DK00-0AB0) Preface. Documentation guide. Product overview.

Transcription:

CPU 412 Function Block protection: A password concept also protects the user program from unauthorized access Integrated HMI services: The user only has to specify the source and destination of the data with HMI devices. The data are then transported cyclically and automatically by the system. Integrated communication functions: PG/OP communication Global data communication S7 standard communication S7 communication Programmable properties The STEP 7 tool "Hardware configuration" can be used to parameterize the properties and response of the S7-400 including the CPUs, e.g. Page 1729 Mar 2008 Siemens ITS

Multipoint interface MPI: Definition of node addresses Startup/cycle behavior Stipulation of the maximum cycle time and communication load Address allocation: Addressing of I/O modules Retentive area: Definition of the number of retentive bit memories, counters, timers, data blocks, and clock memories Size of the process image, local data Length of the diagnostics buffer Protection level: Definition of access authorizations to program and data System diagnostics: Definition of the handling and scope of diagnostics messages Timed interrupts: Setting of periodicity Display and information functions Status and fault indicators: LEDs indicate internal and external faults and operating modes such RUN, STOP, restart,. test function, etc. Test functions: The PG can be used to display signal states in program execution, modify process tags irrespective of the user program, read out the contents of stack memories, run separate program steps and inhibit program components. Information functions: The PG can be used to provide the user with information about the memory capacity and operating mode of the CPU, and the current utilization of the working and load memories Technical specifications Page 1730 Mar 2008 Siemens ITS

Technical specifications 6ES7 412-1XJ05-6ES7 412-2XJ05-6ES7 412-2EK06-0AB0 0AB0 0AB0 CPU 412-1 CPU 412-2 CPU 412-2 PN Product version Hardware product version 03 03 01 Firmware version V5.3 V5.3 V6.0 General information associated programming package STEP7 V 5.3 SP2 or higher with HW update STEP7 V 5.3 SP2 or higher with HW update STEP7 V5.5 or higher/imap V3.0 + imap STEP7 Addon V3.0 SP5 or higher Page 1731 Mar 2008 Siemens ITS

CiR - Configuration in RUN CiR synchronization time, basic load CiR synchronization time, 100 ms 100 ms 100 ms 30 µs; Time per I/O byte time per I/O slave Supply voltage 24 V DC No; Power supply via system power supply Input current from backplane bus 5 V DC, max. 30 µs; Time per I/O 30 µs; Time per I/O byte byte No; Power supply via system power supply 0.6 A 1.1 A 1.3 A No; Power supply via system power supply from interface 5 V DC, max. 90 ma 90 ma; At each DP interface Power losses Power loss, typ. 2.5 W 4.5 W 5.5 W Power loss, max. 3 W 5 W 6.5 W Memory Work memory integrated 288 Kibyte 512 Kibyte 1 Mbyte integrated (for program) 144 Kibyte 256 Kibyte 0.5 Mbyte integrated (for data) 144 Kibyte 256 Kibyte 0.5 Mbyte expandable No No No 90 ma; At the DP interface Page 1732 Mar 2008 Siemens ITS

Load memory expandable FEPROM ; with Memory ; with Memory ; with Memory Card (FLASH) Card (FLASH) Card (FLASH) expandable FEPROM, max. 64 Mbyte 64 Mbyte 64 Mbyte integrated RAM, max. 512 Kibyte 512 Kibyte 512 Kibyte expandable RAM ; with Memory ; with Memory ; with Memory Card (RAM) Card (RAM) Card (RAM) expandable RAM, max. 64 Mbyte 64 Mbyte 64 Mbyte Backup present with battery ; all data ; all data ; all data without battery No No No CPU-blocks DB Number, max. 1 500; Number range: 1 to 16000 3 000; Number range: 1 to 16000 Size, max. 64 Kibyte 64 Kibyte 64 Kibyte FB Number, max. 750; Number range: 1 500; Number 3 000; Number range: 1 to 16000 1 500; Number range: 0 to 7999 0 to 7999 range: 0 to 7999 Size, max. 64 Kibyte 64 Kibyte 64 Kibyte FC Number, max. 750; Number range: 1 500; Number 1 500; Number Page 1733 Mar 2008 Siemens ITS

range: 0 to 7999 range: 0 to 7999 range: 0 to 7999 Size, max. 64 Kibyte 64 Kibyte 64 Kibyte OB Size, max. 64 Kibyte 64 Kibyte 64 Kibyte Nesting depth per priority class 24 24 24 additional within an error 1 1 1 OB CPU processing times for bit operations, min. 75 ns 75 ns 75 ns for word operations, min. 75 ns 75 ns 75 ns for fixed point arithmetic, 75 ns 75 ns 75 ns min. for floating point 225 ns 225 ns 225 ns arithmetic, min. Counters, timers and their retentivity S7 counter Number 2 048 2 048 2 048 Retentivity adjustable 0 0 0 lower limit Page 1734 Mar 2008 Siemens ITS

2 047 2 047 2 047 upper limit Z 0 to Z 7 Z 0 to Z 7 Z 0 to Z 7 preset Counting range 0 0 0 lower limit 999 999 999 upper limit IEC counter present Type SFB SFB SFB Number Unlimited (limited Unlimited (limited only by RAM capacity) only by RAM capacity) S7 times Number 2 048 2 048 2 048 Retentivity adjustable lower limit upper limit 0 0 0 2 047 2 047 2 047 Unlimited (limited only by RAM capacity) Page 1735 Mar 2008 Siemens ITS

No times retentive No times retentive No times retentive preset Time range 10 ms 10 ms 10 ms lower limit 9 990 s 9 990 s 9 990 s upper limit IEC timer present Type SFB SFB SFB Number Unlimited (limited Unlimited (limited Unlimited (limited only by RAM capacity) only by RAM capacity) only by RAM capacity) Data areas and their retentivity retentive data area, total Flag Number, max. Total working and Total working and load memory (withload memory (with backup battery) backup battery) 4 Kibyte; Size of bit memory address area 4 Kibyte; Size of bit memory address area Total working and load memory (with backup battery) 4 Kibyte; Size of bit memory address area Retentivity available Retentivity preset MB 0 to MB 15 MB 0 to MB 15 MB 0 to MB 15 Page 1736 Mar 2008 Siemens ITS

Number of clock 8; (in 1 memory 8; (in 1 memory 8; (in 1 memory memories byte) byte) byte) Local data adjustable, max. 8 Kibyte 8 Kibyte 8 Kibyte preset 4 Kibyte 4 Kibyte 4 Kibyte Address area I/O address area Inputs 4 Kibyte 4 Kibyte 4 Kibyte Outputs 4 Kibyte 4 Kibyte 4 Kibyte of which, distributed MPI/DP interface, inputs MPI/DP interface, outputs DP interface, inputs DP interface, outputs PN interface, 2 Kibyte 2 Kibyte 2 Kibyte 2 Kibyte 2 Kibyte 2 Kibyte 4 Kibyte 4 Kibyte 4 Kibyte Page 1737 Mar 2008 Siemens ITS

inputs 4 Kibyte PN interface, outputs Process image Inputs, adjustable 4 Kibyte 4 Kibyte 4 Kibyte Outputs, adjustable 4 Kibyte 4 Kibyte 4 Kibyte Inputs, default 128 byte 128 byte 128 kbyte Outputs, default 128 byte 128 byte 128 Kibyte consistent data, max. 244 byte 244 byte 244 byte Access to consistent data in process image Subprocess images Number of subprocess 15 15 15 images, max. Digital channels Inputs 32 768 32 768 32 768 Outputs 32 768 32 768 32 768 Inputs, of which central 32 768 32 768 32 768 Outputs, of which central 32 768 32 768 32 768 Analog channels Inputs 2 048 2 048 2 048 Outputs 2 048 2 048 2 048 Inputs, of which central 2 048 2 048 2 048 Page 1738 Mar 2008 Siemens ITS

Outputs, of which central 2 048 2 048 2 048 Hardware configuration Expansion devices, max. 21 21 21 Multicomputing Interface modules Number of connectable IMs (total), max. Number of connectable IM 460s, max. Number of connectable ; 4 CPUs max. (with UR1 or UR2) ; 4 CPUs max. (with UR1 or UR2) 6 6 6 6 6 6 ; 4 CPUs max. (with UR1 or UR2) 4; IM 463-2 4; IM 463-2 4; IM 463-2 IM 463s, max. Number of DP masters integrated 1 2 1 via IM 467 4 4 4 via CP 10; CP 443-5 Extended Mixed mode IM + CP permitted No; IM 467 not suitable for use with CP 443-5 Ext. and CP443-1 EX4x, EX20, GX20 (in PNIO 10; CP 443-5 Extended No; IM 467 not suitable for use with CP 443-5 Ext. and CP443-1 EX4x, EX20, GX20 (in PNIO mode) 10; CP 443-5 Extended No; IM 467 not suitable for use with CP 443-5 Ext. and CP443-1 EX4x, EX20, GX20 (in PNIO mode) Page 1739 Mar 2008 Siemens ITS

mode) via interface module 0 0 0 Number of pluggable S5 6 6 6 modules (via adapter capsule in central device), max. Number of IO Controllers integrated 0 0 1 via CP 4; No mixed operation of CP443-1 EX40 and CP443-1 EX 41/EX20/GX20, 4; No mixed operation of CP443-1 EX40 and CP443-1 EX 41/EX20/GX20, max. 4 in central max. 4 in central controller controller Number of operable FMs and CPs (recommended) FM CP, point-to-point Limited by number of slots and number of connections CP 440: Limited by number of slots; CP 441: Limited by number of slots and number of connections CP 440: Limited by number of slots; CP 441: Limited by 4; No mixed operation of CP443-1 EX40 and CP443-1 EX 41/EX20/GX20, max. 4 in central controller Limited by number of slots and number of connections CP 440: Limited by number of slots; CP 441: Limited by Page 1740 Mar 2008 Siemens ITS

CP, point-to-point PROFIBUS and Ethernet CPs Time of day Clock Hardware clock (real-time clock) battery-backed and synchronizable Limited by number of slots and number of connections 14; Of which 10 CPs max. or IMs as DP master, 4 PN controller maximum number of slots and number of connections number of slots and number of connections 14; Of which 10 CPs14; In total max. 10 max. or IMs as DP CPs as DP master master, 4 PN and PN controller, controller maximum of which up to 10 IMs or CPs as DP master and up to 4 CPs as PN controller Resolution 1 ms 1 ms 1 ms Deviation per day (buffered), max. 1.7 s; Power off 1.7 s; Power off 1.7 s; Power off Deviation per day 8.6 s; For power 8.6 s; For power On 8.6 s; For power On (unbuffered) max. On Operating hours counter Number 16 16 16 Page 1741 Mar 2008 Siemens ITS

Number/Number range 0 to 15 0 to 15 0 to 15 Range of values SFCs 2, 3 and 4: 0 to 32767 hours SFC 101: 0 to 2^31-1 hours SFCs 2, 3 and 4: 0 to 32767 hours SFC 101: 0 to 2^31-1 hours SFCs 2, 3 and 4: 0 to 32767 hours SFC 101: 0 to 2^31-1 hours Granularity 1 hour 1 hour 1 hour retentive Clock synchronization supported to MPI, master to MPI, slave to DP, master to DP, slave in AS, master in AS, slave on Ethernet via NTP No; via CP No; via CP ; as client to IF 964 DP No No Interfaces Interfaces 1 x MPI/PROFIBUS DP 1 x MPI/PROFIBUS DP, 1 x PROFIBUS DP Number of USB interfaces 0 0 0 1st interface 1 x MPI/PROFIBUS DP, 1 x PROFINET (2 ports) Page 1742 Mar 2008 Siemens ITS

Type of interface integrated integrated integrated Physics RS 485 / RS 485 / PROFIBUSRS 485 / PROFIBUS + MPI+ MPI PROFIBUS + MPI Isolated Power supply to interface 150 ma 150 ma 150 ma (15 to 30 V DC), max. Number of connection MPI: 32, DP: 16 MPI: 32, DP: 16 MPI: 32, DP: 16 resources Functionality MPI DP master DP slave Type of interface integrated integrated integrated Physics RS 485 / PROFIBUS + MPI RS 485 / PROFIBUS + MPI Isolated Power supply to interface (15 to 30 V DC), max. 150 ma 150 ma 150 ma Number of connection resources Functionality RS 485 / PROFIBUS + MPI MPI: 32, DP: 16 MPI: 32, DP: 16 MPI: 32, DP: 16 Page 1743 Mar 2008 Siemens ITS

MPI DP master DP slave MPI Number of connections 32; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1 Services PG/OP communication Routing Global data communication S7 basic 32; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1 32; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1 Page 1744 Mar 2008 Siemens ITS

communication S7 communication S7 communication, as client S7 communication, as server Transmission rate, max. 12 Mbit/s 12 Mbit/s 12 Mbit/s DP master Number of connections, max. Services 16; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1 16; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1 16; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1 Page 1745 Mar 2008 Siemens ITS

PG/OP communication Global data communication S7 basic communication S7 communication S7 communication, as client S7 communication, as server Equidistance mode support No No No Page 1746 Mar 2008 Siemens ITS

Isochronous mode SYNC/FREEZE Activation/deactiva tion of DP slaves Direct data exchange (slaveto-slave communication) DPV1 Transmission rate, max. 12 Mbit/s 12 Mbit/s 12 Mbit/s Number of DP slaves, max. Address area Inputs, max. Outputs, max. User data per DP slave 32 32 32 2 Kibyte 2 Kibyte 2 Kibyte 2 Kibyte 2 Kibyte 2 Kibyte Page 1747 Mar 2008 Siemens ITS

244 byte 244 byte 244 byte User data per DP slave, max. 244 byte 244 byte 244 byte Inputs, max. 244 byte 244 byte 244 byte Outputs, max. 244 244 244 Slots, max. 128 byte 128 byte 128 byte per slot, max. DP slave Number of connections 16 16 16 Services ; with ; with interface interface active active PG/OP communication S7 routing Global data communication S7 basic ; with interface active ; with ; with interface ; with interface interface active active active No No No No No No Page 1748 Mar 2008 Siemens ITS

communication S7 communication S7 communication, as client S7 communication, as server Direct data exchange (slaveto-slave communication) DPV1 GSD file No No No No No No http://support.auto http://support.automahttp://support.autom mation.siemens.c tion.siemens.com/w ation.siemens.com/ om/ww/view/de/1 W/view/de/113652 WW/view/de/11365 13652 2 Transmission rate, max. 12 Mbit/s 12 Mbit/s 12 Mbit/s Page 1749 Mar 2008 Siemens ITS

Automatic baud rate No No No search Transfer memory 244 byte 244 byte 244 byte Inputs 244 byte 244 byte 244 byte Outputs Address area, max. 32; Virtual slots 32; Virtual slots 32; Virtual slots User data per address 32 byte 32 byte 32 byte area, max. User data per address 32 byte 32 byte 32 byte area, of which consistent, max. 2nd interface Type of interface integrated PROFINET Physics RS 485 / Ethernet RJ45 PROFIBUS Isolated Integrated switch Number of ports 2 Power supply to 150 ma interface (15 to 30 V DC), max. Automatic detection of ; Autosensing Page 1750 Mar 2008 Siemens ITS

transmission speed Autonegotiation Autocrossing Media redundancy supported Switchover time on line break, typically Number of stations in the ring, max. Change of IP address at runtime, supported 200 ms Page 1751 Mar 2008 Siemens ITS 50 ; Assignment by higher-level IO- Controller or by the user program with SFB104 "IP_CONF" 16 48 Number of connection resources Functionality DP master No DP slave No PROFINET IO Controller PROFINET IO Device PROFINET CBA

Local Operating Network DP master Number of connections, max. Services PG/OP communication Global data communication S7 basic communication S7 communication S7 communication, as client S7 Page 1752 Mar 2008 Siemens ITS 16 No No

communication, as server Equidistance mode support Isochronous mode SYNC/FREEZE Activation/deactiva tion of DP slaves Direct data exchange (slaveto-slave communication) DPV1 Transmission rate, max. Number of DP slaves, max. Address area Page 1753 Mar 2008 Siemens ITS 12 Mbit/s 64

4 Kibyte Inputs, max. 4 Kibyte Outputs, max. User data per DP slave 244 byte User data per DP slave, max. 244 byte Inputs, max. 244 byte Outputs, max. 244 Slots, max. 128 byte per slot, max. DP slave Number of connections 16 GSD file Transmission rate, max. Transfer memory http://support.automa tion.siemens.com/w W/view/de/113652 12 Mbit/s Page 1754 Mar 2008 Siemens ITS

244 byte Inputs 244 byte Outputs Address area, max. 32 User data per address 32 byte area, max. User data per address 32 byte area, of which consistent, max. PROFINET IO Controller Services PG/OP communication S7 routing S7 communication Isochronous mode Page 1755 Mar 2008 Siemens ITS ; Only with IRT and the High Performance option

Open IE communication Transmission rate, max. Number of connectable IO devices, max. Max. number of connectable IO devices for RT of which in line, max. Number of IO devices with IRT and the option "high flexibility" of which in line, max. Number of IO Devices with IRT and the option "high performance", max. of which in line, max. Shared device, 100 Mbit/s 256 Page 1756 Mar 2008 Siemens ITS 256 256 256 61 64 64

supported Prioritized startup supported Number of IO Devices, max. Activation/deactivation of IO Devices Number of IO Devices that can be simultaneously activated/deactivat ed, max. IO Devices changing during operation (partner ports), supported Max. number of IO devices per tool Page 1757 Mar 2008 Siemens ITS 32 8 8; 8 parallel calls of the SFC 12 "D_ACT_DP" possible per line. Max. 32 IO Devices changing during operation

(partner ports) are supported. Device replacement without swap medium Send cycles 250 μs, 500 μs, 1 ms, 2 ms, 4 ms additionally with IRT with high performance: 250 µs to 4 ms in 125 µs frame Updating time 250 µs to 512 ms; minimum value depends on preset communication share for PROFINET IO, on the number of IO Devices and on the amount of configured user data, see PROFINET system description Page 1758 Mar 2008 Siemens ITS

Address area Inputs, max. Outputs, max. User data per address area, max. User data consistency, max. PROFINET IO Device Services PG/OP communication S7 routing S7 communication Isochronous mode 4 Kibyte 4 Kibyte 1 024 byte Page 1759 Mar 2008 Siemens ITS No

Open IE communication IRT, supported Prioritized startup supported Shared device, supported Number of IO controllers with shared device, max. Transfer memory Inputs, max. Outputs, max. Submodules Page 1760 Mar 2008 Siemens ITS 2 1 440 byte; Per IO Controller with shared device 1 440 byte; Per IO Controller with shared device 64

Number, max. 1 024 byte User data per submodule, max. Open IE communication Open IE communication, supported Number of connections, max. 46 Local port numbers used at the system end 0, 20, 21, 25, 80, 102, 135, 161, 34962, 34963, 34964, 65532, 65533, 65534, 65535 Keep-alive function, supported Communication functions PG/OP communication Number of connectable OPs 31 31 47 without message processing Number of connectable OPs with message processing 31; When using alarm_s and alarm_d 31; When using alarm_s and alarm_d Data record routing Global data communication 47; When using Alarm_S/SQ and Alarm_D/DQ Page 1761 Mar 2008 Siemens ITS

supported Number of GD packets, 8 8 8 transmitter, max. Number of GD packets, receiver, max. 16 16 16 Size of GD packets, max. 54 byte 54 byte 54 byte Size of GD packet (of which 1 variable 1 variable 1 variable consistent), max. S7 basic communication supported User data per job, max. 76 byte 76 byte 76 byte User data per job (of which 1 variable 1 variable 1 variable consistent), max. S7 communication supported as server as client User data per job, max. 64 Kibyte 64 Kibyte 64 Kibyte User data per job (of which 462 byte 462 byte; 1 variable462 byte; 1 variable consistent), max. S5-compatible communication supported ; Via FC ; Via FC AG_SEND and AG_RECV, max. AG_SEND and AG_RECV, max. ; Via FC AG_SEND and AG_RECV, max. via Page 1762 Mar 2008 Siemens ITS

supported via 10 CP 443- via 10 CP 443-1 10 CP 443-1 or 443-1 or 443-5 or 443-5 5 User data per job, max. 8 Kibyte 8 Kibyte 8 Kibyte User data per job (of which 240 byte 240 byte 240 byte consistent), max. Number of simultaneous AG- 24/24 24/24 24/24 SEND/AG-RECV orders per CPU, max. Standard communication (FMS) supported Open IE communication TCP/IP Number of connections, max. Data length, max. Several passive connections per port, ; Via CP ; Via CP and and loadable FBloadable FB ; Via CP and loadable FB ; via integrated PROFINET interface and loadable FBs 46 32 Kibyte Page 1763 Mar 2008 Siemens ITS

supported ISO-on-TCP (RFC1006) Via CP 443-1 Adv. and loadable FB Number of connections, max. Data length, max. UDP Number of connections, max. 1452 bytes via CP 443-1 Adv. Via CP 443-1 and loadable FB 1452 bytes via CP 443-1 Adv. 1 472 byte Data length, max. Web server supported No No Number of HTTP clients 5 User-defined websites PROFINET CBA (at set setpoint communication load) ; Via integrated PROFINET interface or CP 443-1 Adv. and loadable FBs 46 32 Kibyte; 1452 bytes via CP 443-1 Adv. ; via integrated PROFINET interface and loadable FBs 46 Page 1764 Mar 2008 Siemens ITS

Setpoint for the CPU communication load Number of remote interconnection partners Number of functions, master/slave Total of all Master/Slave connections Data length of all incoming connections master/slave, max. Data length of all outgoing connections master/slave, max. Number of device-internal and PROFIBUS interconnections Data length of device-internal und PROFIBUS interconnections, max. Data length per connection, max. Remote interconnections with acyclic transmission Sampling frequency: 20 % Page 1765 Mar 2008 Siemens ITS 32 150 4 500 45 000 byte 45 000 byte 1 000 16 000 byte 2 000 byte 200 ms; Depending on preset

Sampling time, min. Number of incoming interconnections Number of outgoing interconnections Data length of all incoming interconnections, max. Data length of all outgoing interconnections, max. Data length per connection, max. Remote interconnections with cyclic transmission communication load, number of interconnections and data length used Page 1766 Mar 2008 Siemens ITS 250 250 8 000 byte 8 000 byte 2 000 byte

Transmission frequency: Transmission interval, min. Number of incoming interconnections Number of outgoing interconnections Data length of all incoming interconnections, max. Data length of all outgoing interconnections, max. Data length per connection, max. 1 ms; Depending on preset communication load, number of interconnections and data length used Page 1767 Mar 2008 Siemens ITS 300 300 4 800 byte 4 800 byte 450 byte

HMI variables via PROFINET (acyclic) Number of stations that can log on for HMI variables (PN OPC/iMap) HMI variable updating Number of HMI variables Data length of all HMI variables, max. PROFIBUS proxy functionality supported 2x PN OPC/1x imap 500 ms 1 000 32 000 byte ; 32 PROFIBUS slaves max. connectable 240 byte; Slavedependent Data length per connection, max. Number of connections overall 32 32 48 S7 message functions Page 1768 Mar 2008 Siemens ITS

Number of login stations for message functions, max. 31; Max. 31 31; Max. 31 47; Max. 47 with with alarm_s andwith alarm_s andalarm_s/sq and alarm_d (OP's); max. 8 with alarm_8 and alarm_p (e.g. WinCC) alarm_d (OP's); max. 8 with alarm_8 and alarm_p (e.g. WinCC) Alarm_D/DQ (OPs); max. 8 with Alarm, Alarm_8, Alarm_8P, Notify and Notify_8 (e.g. WinCC) Symbol-related messages SCAN procedure Number of messages overall, max. 256 256 256 Block related messages Process diagnostic messages simultaneously active Alarm-S blocks, max. 250; Simultaneously active alarm_s/sq blocks or alarm_d/dq blocks 250; Simultaneously active alarm_s/sq blocks or alarm_d/dq blocks Alarm 8-blocks Number of instances for alarm 8 300 300 300 250; Simultaneously active alarm_s/sq blocks or alarm_d/dq blocks Page 1769 Mar 2008 Siemens ITS

and S7 communication blocks, max. preset, max. 150 150 150 Process control messages Test commissioning functions Status/control Status/control variable ; Up to 16 ; Up to 16 ; Up to 16 Variables variable tables Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters variable tables Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters variable tables Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters Number of variables, max. 70; Status/control 70; Status/control 70; Status/control Forcing Forcing Force, variables Inputs/outputs, bitinputs, outputs, Inputs/outputs, bit memories, bit memories, memories, distributed I/Os peripheral inputs, distributed I/Os peripheral outputs Number of variables, max. 64 64 64 Status block ; Up to 2 ; Up to 2 simultaneously simultaneously Single step ; Up to 16 simultaneously Page 1770 Mar 2008 Siemens ITS

Number of breakpoints 4 4 16 Diagnostic buffer present Number of entries, max. 200 400 400 adjustable 120 120 120 preset Isochronous mode Isochronous mode ; For PROFIBUS only ; For PROFIBUS only Number of DP masters with 1 2 1 isochronous mode User data per isochronous slave, 244 byte 244 byte 244 byte max. equidistance shortest clock pulse 1.5 ms; 0.5 ms without use of SFC 126, 127 1.5 ms; 0.5 ms without use of SFC 126, 127 max. cycle 32 ms 32 ms 32 ms Configuration Configuration software ; Via PROFIBUS DP or PROFINET interface 1.5 ms; 0.5 ms without use of SFC 126, 127 Page 1771 Mar 2008 Siemens ITS

STEP 7 programming Programming language LAD FBD STL SCL CFC GRAPH HiGraph Command set see instruction see instruction see instruction list list list Nesting levels 7 7 7 Know-how protection User program protection/password protection Block Pageencryption 1772 Mar 2008 ; Siemens With S7ITS block Privacy

Block encryption ; With S7 block Privacy Dimensions Width 25 mm 25 mm 25 mm Height 290 mm 290 mm 290 mm Depth 219 mm 219 mm 219 mm Required slots 1 1 1 Weight Weight, approx. 0.7 kg 0.7 kg 750 g Page 1773 Mar 2008 Siemens ITS