BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL PNP TRANSISTOR OUTPUT MODULE, 16 points (MECHATROLINK-I / -II, short circuit protection)

Similar documents
NPN / PNP DISCRETE INPUT & NPN TRANSISTOR OUTPUT MODULE, 16 points each

NPN/PNP DISCRETE HIGH SPEED INPUT & NPN TRANSISTOR OUTPUT MODULE

R7D-RR8 BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL REMOTE CONTROL RELAY CONTROL MODULE, 8 points MODEL. (DeviceNet)

R6-NC1 BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL CC-Link INTERFACE MODULE MODEL. (CC-Link Ver.1.10; for 16-point analog signals)

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

R3-NL1 LONWORKS INTERFACE MODULE BEFORE USE... INSTALLATION POINTS OF CAUTION INSTRUCTION MANUAL. R3-nL1 MODEL

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

DLS-E2 TELEMETERING UNIT BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL MODEL. (16 contact inputs & 16 open collector outputs)

R3-GE1 BEFORE USE... INSTALLATION POINTS OF CAUTION INSTRUCTION MANUAL ETHERNET INTERFACE MODULE MODEL. (Modbus/TCP)

PWR. Power Module Slots

R3-NL2 INSTALLATION BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL LONWORKS INTERFACE MODULE MODEL. (I/O 56 points)

R6-NE1 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL ETHERNET INTERFACE MODULE MODEL. (Modbus/TCP, for 32-point analog signals)

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

MODEL: R2K-1 SEN TRONIC AG. R2K Series

MODEL: R3-NE1. Remote I/O R3 Series. ETHERNET INTERFACE MODULE (Modbus/TCP) 27.5 (1.08)

R3-NE1 ETHERNET INTERFACE MODULE MODEL. Remote I/O R3 Series. (Modbus/TCP)

R1M-J3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL RTD & POTENTIOMETER INPUT MODULE MODEL. (8 points)

MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R3-NFL1. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) Remote I/O R3 Series

CONTENTS 1. BEFORE USE GENERAL DESCRIPTION POINTS OF CAUTION HARDWARE SPECIFICATIONS... 4

NETC01-M2. Network converter USER MANUAL. MECHATROLINK-Ⅱ compatible HM

R7X CONFIGURATOR. (model: R7CON) Users Manual , Minamitsumori, Nishinari-ku, Osaka JAPAN Tel: Fax:

INSTRUCTION MANUAL 2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

TABLE OF CONTENTS. Communication Functions

1) Indicates that the identified danger WILL cause physical and property damage.

MODEL: R3-NL2. RELATED PRODUCTS XIF File (Device Interface File) XIF file is used to define a LonWorks device when programmed on LonMaker.

THT-500-A/R (C5) 1. System Configuration COMMUNICATION INSTRUCTION MANUAL. No. THT5CE

Communication Controller CC-Link/CPL Converter CMC10A

THERMO-CON. Model No. HECR002-A5. Keep available whenever necessary.

Anybus-S CC-Link. Fieldbus Appendix. Rev HMS Industrial Networks AB. Germany Japan Sweden U.S.A UK

Technical Manual. YASKAWA AC Drive-Option Card MECHATROLINK-II. Type: SI-T3

MODEL: R1M-GH. PC Recorders R1M Series

R: Red Y: Amber G: Green B: Blue W: White. R: Red Y: Amber G: Green B: Blue W: White. R: Red Y: Amber G: Green B: Blue W: White.

USB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD.

Enhanced communication

EtherCAT Remote I/O Terminal GX series

KTA-250 Anemometer Alarm Card

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

EX-RC1 Remote I/O Adapter

MODEL: GR8-EM. Communication Adaptor GR8 Series

USER'S GUIDE FX-485ADP COMMUNICATION ADAPTER FX0N-485ADP COMMUNICATION ADAPTER

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

Vorne Industries. 2000S Series Serial Input Alphanumeric Display User's Manual

MODEL: R3-NL1. RELATED PRODUCTS XIF File (Device Interface File) XIF file is used to define a LonWorks device when programmed on LonMaker.

48NDVD BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL BARGRAPH INDICATING ALARM MODEL

SATEL I-LINK 100 MB I/O-converter User Guide, Version 1.1

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

USER S MANUAL. FX2N-64DNET DeviceNet Interface Block

No.170. R7L Series I/O Type Addition. February 2009 I N S I D E

Switching Power Supply

FR-2057iT. 16-channel Sink Type Isolated Output Module With Isolated Communication line. User Manual

MODEL: WL40EW2F. Wireless I/O WL40F Series

DX200 OPTIONS MECHATROLINK-II COMMUNICATION FUNCTION INSTRUCTIONS

Analog Input/Output Modules

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

EX-RC1 Remote I/O Adapter

DELOMATIC - MULTI-FUNCTION SYSTEM PART 2 INSTALLATION INSTRUCTION

RTU560 Connections and Settings DIN Rail RTU 560CIG10

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

High Speed Remote I/O Module

IO-DI8-RO8, IO-DI8-RO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

SSI-1016H Specifications and Operation Manual

FA-M3 FA Link H Modules FA-bus Modules. Contents. F3LP02-0N FA Link H Module F3LP12-0N Fiber-Optic FA Link H Module... 5

MODEL: M1EXV. OUTPUT Field-selectable DC Output Current output: 0-20 ma DC Voltage output: V DC Voltage output: V DC

NPN output PNP output Cord connection Cord length: 2 m Through-beam 7 m Light-ON. 2 m. (selectable by wiring) Diffuse reflective 0.

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

EX-RC1 Remote I/O Adapter

MODEL: MD7ST. [3] LOOP DISCONNECT FUSE 0: Without 1: With (CENELEC/ATEX approval Not selectable)

Operating instructions. ProcessLine analogue module AC / / 2012

Communications & Networking

COMMUNICATION CONVERTER FOR PROFIBUS

Appearance Size (mm) Power supply voltage Model (W H D) 100 to 240 VAC K3SC to 240 VAC

Trajexia motion controller

FA-M3 FA Link H Modules FA-bus Modules. Contents. F3LP02-0N FA Link H Module F3LP12-0N Fiber-Optic FA Link H Module... 5

MODEL: 40DN. Digital Panel Meters 40 Series

General Specifications

MODEL: M1EXM. OUTPUT Field-selectable DC Output Current output: 0-20 ma DC Voltage output: V DC Voltage output: V DC

Island bus expansion module

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

Switched Mode Power Supply Operating manual PAP800

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

Hints for Replacement of Obsolete Controller Models BY240 with New Models BY340

Preface. The CC-Link unit is compatible with up to CC-Link Ver. 2.0.

EX120/121/122 Series Some protocols are not CE-compliant.

MGate 5111 Quick Installation Guide

Safety Relay Unit (I/O Unit Type)

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

RTD-NET Installation Instructions

T1K MODBUS Base Controller Specifications

Trajexia Motion Controller

Eaton Logic Controller Modbus Distributed I/O Adapter Module INSTRUCTION SHEET

DIO-1616LN-FIT. Features. Specifications. Ethernet Remote I/O F&eIT N Series Isolated Digital Input/Output Unit DIO-1616LN-FIT 1. Ver.1.

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

Transcription:

INSTRUCTION MANUAL PNP TRANSISTOR OUTPUT MODULE, 16 points (MECHATROLINK-I / -II, short circuit protection) R7ML-DC16D MODEL R7ML-DC16D BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If you have any problems or questions with the product, please contact M-System s Sales Office or representatives. PACKAGE INCLUDES Discrete output module... (1) MODEL NO. Confirm that the model number described on the product is exactly what you ordered. INSTRUCTION MANUAL This manual describes necessary points of caution when you use this product, including installation, connection and basic maintenance procedures. POINTS OF CAUTION CONFORMITY WITH EU DIRECTIVE Use MECHATROLINK-II network cable with core (Yasukawa Controls Model JEPEC-W63-x-E) or equivalent for the network. Be sure to earth FG terminal. The actual installation environments such as panel configurations, connected devices and connected wires may affect the protection level of this unit when it is integrated in a panel system. The user may have to review the CE requirements in regard to the whole system and employ additional protective measures to ensure CE conformity. POWER INPUT RATING & OPERATIONAL RANGE Locate the power input rating marked on the product and confirm its operational range as indicated below 24V DC rating 24V ±1%, approx. 85mA GENERAL PRECAUTIONS Before you remove the unit or mount it, turn off the power supply and input signal for safety. ENVIRONMENT Indoor use. When heavy dust or metal particles are present in the air, install the unit inside proper housing with sufficient ventilation. Do not install the unit where it is subjected to continuous vibration. Do not subject the unit to physical impact. Environmental temperature must be within to 55 C (32 to 1 F) with relative humidity within 3 to 9% RH in order to ensure adequate life span and operation. WIRING Do not install cables close to noise sources (relay drive cable, high frequency line, etc.). Do not bind these cables together with those in which noises are present. Do not install them in the same duct. FG terminal is NOT a protective conductor terminal. AND... The unit is designed to function as soon as power is supplied, however, a warm up for 1 minutes is required for satisfying complete performance described in the data sheet. 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-63 JAPAN Phone +81(6)6659-821 Fax +81(6)6659-851 E-mail info@m-system.co.jp EM-785-X Rev.1 P. 1 / 1

COMPONENT IDENTIFICATION FRONT VIEW MECHATROLINK Setting Rotary SW Operating Mode Setting DIP SW (SW1) Station Address Setting Rotary SW Status Indicator LED PC Configurator Jack Discrete Output Status Indicator LED MECHATROLINK Connector PWR ERR RD RUN SD X1 X1 789ABCDEF123456 789ABCDEF123456 STATION ADD. 1 2 3 4 5 6 7 8 9 B. RATE 1 2 3 4 5 6 7 8 CNFG. 1 2 3 4 5 6 7 8 9 A B C D E F 4 5 6 7 1 2 3 1 11 12 13 14 15 16 18 1 2 3 4 5 6 7 8 9 Power Supply Terminals Output Terminals LEFT SIDE VIEW MECHATROLINK Connector 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-63 JAPAN Phone +81(6)6659-821 Fax +81(6)6659-851 E-mail info@m-system.co.jp EM-785-X Rev.1 P. 2 / 1

89ABCDEF1234567 89ABCDEF1234567 R7ML-DC16D STATUS INDICATOR LED ID COLOR FUNCTION PWR Green Turns on when the internal 5V is supplied normally. RUN Green Turns on in normal communications conditions. ERR Red Turns on in no communication or setting error. SD Green Turns on when the module is transmitting. RD Green Turns on when the module is receiving. STATION ADDRESS Station Address is selected between 6H and 7FH (Intelligent I/O) in hexadecimal. (Certain numbers may not be selectable depending on the master types. Refer to the instruction manual of the master unit.) The left switch determines the MSD, while the right switch does the LSD of the address. (Factory setting 6H) DISCRETE OUTPUT STATUS INDICATOR LED Discrete output modules have LED indicators showing output signal status. Contact ON LED ON Contact OFF LED OFF POWER SUPPLY TERMINAL ASSIGNMENT 4 5 6 NC NC +24V 1 2 NC NC 3 FG 7 V NO. ID FUNCTION, NOTES 1 NC ---- 2 NC ---- 3 FG FG 4 NC ---- 5 NC ---- 6 +24V Power input (24V DC) 7 V Power input (V) OUTPUT TERMINAL ASSIGNMENT Station Address Setting (LSD) Station Address Setting (MSD) MECHATROLINK MODE Choose MECHATROLINK-I or -II, and the data size. Positions 2, 4 through 9 are unused. (Factory setting 1) 4 3 2 1 5 6 7 9 8 MECHATROLINK-II (32-byte mode) 1 MECHATROLINK-II (-byte mode) 3 MECHATROLINK-I (-byte mode) MECHATROLINK Setting EXTENSION MODULE Combinations with any extension module is selectable. OPERATING MODE (*) Factory setting 1 11 +24 V Y1 2 Y 1 V 3 Y2 12 Y3 4 Y4 13 Y5 5 Y6 14 Y7 6 Y8 15 Y9 7 YA 16 YB 8 YC YD 9 YE 18 YF NO. ID FUNCTION NO. ID FUNTION 1 V V 1 +24V 24V DC (common) 2 Y Output 11 Y1 Output 1 3 Y2 Output 2 12 Y3 Output 3 4 Y4 Output 4 13 Y5 Output 5 5 Y6 Output 6 14 Y7 Output 7 6 Y8 Output 8 15 Y9 Output 9 7 YA Output 1 16 YB Output 11 8 YC Output 12 YD Output 13 9 YE Output 14 18 YF Output 15 Extension (SW1-1, 1-2) SW1-1 SW1-2 Extension OFF OFF No extension (*) ON OFF Discrete input, 8 or 16 points OFF ON Discrete output, 8 or 16 points Output at the loss of communication (SW1-4) SW1-4 Output at the loss of communication OFF Reset the output (turned off) ON Hold the output (*) (maintains the last data received normally) Caution! - SW1-3, 1-5, 1-6, 1-7, 1-8 are unused. Be sure to turn off unused ones. 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-63 JAPAN Phone +81(6)6659-821 Fax +81(6)6659-851 E-mail info@m-system.co.jp EM-785-X Rev.1 P. 3 / 1

EXTERNAL DIMENSIONS unit mm (inch) 3 (.12) 115 (4.53) (.66) 54 (2.13) 5 (1.97) 18.5 (.73) DIN RAIL 35mm wide 4 5 6 7 1 11 12 13 14 15 16 18 1 2 3 1 2 3 4 5 6 7 8 9 3 (.12) 3 (1.18) [5 (.2)] 75 (2.95) 6 (.24) 6 (.24) 5.5 (.22) 7 M3 SCREW TERMINALS for POWER 18 M3 SCREW TERMINALS for OUTPUT CONNECTION DIAGRAM Connect the unit as in the diagram below. Note In order to improve EMC performance, bond the FE terminal to ground. Caution FE terminal is NOT a protective conductor terminal. * * FG 24V DC V MECHATROLINK CONNECTOR MECHATROLINK CONNECTOR 3 6 7 1 +24V 2 Y 3 Y2 4 Y4 5 Y6 6 Y8 7 YA 8 YC 9 YE 11 Y1 12 Y3 Output Connection Example +24V 1 + V 1 Y 2 YF 18 EXTENSION CONNECTOR 13 Y5 14 Y7 15 Y9 16 YB 18 YD YF 1 V *MECHATROLINK connectors are internally connected. The network cable can be connected to either one. 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-63 JAPAN Phone +81(6)6659-821 Fax +81(6)6659-851 E-mail info@m-system.co.jp EM-785-X Rev.1 P. 4 / 1

WIRING INSTRUCTIONS SCREW TERMINAL Torque.5 N m SOLDERLESS TERMINAL mm (inch) Refer to the drawing below for recommended ring tongue terminal size. Spade tongue type is also applicable. Solderless terminal Applicable wire size.25 to 1.65 mm 2 (AWG 22 to 16) Recommended manufacturer Japan Solderless Terminal MFG. Co., Ltd, Nichifu Co., Ltd 3.3 (.13) max 6 (.24) max mm (inch) MECHATROLINK CONNECTION MECHATROLINK CONNECTION Master Slave * * terminator SRD+ SRD+ SRD+ SRD+ SRD+ SRD+ terminator MECHATROLINK Cable MECHATROLINK Cable * Terminator Be sure to connect the terminating resistors to the unit at both ends of transmission line. Use the terminating resistor dedicated for MECHATROLINK Model JEPMC-W622, Yaskawa Controls Co., Ltd. Certain types of Master units may have incorporated terminating resistors. Consult the instruction manual for the Master. Slave MECHATROLINK COMMUNICATION MECHATROLINK-I Baud rate 4 Mbps Transmission distance 5 m max. Distance between stations 3 cm min. Transmission media MECHATROLINK cable (Model JEPMC-W63-x-E, Yaskawa Controls Co., Ltd.) Max. number of slaves 15 (The maximum number of slaves might change depending on the master unit. Refer to the manual of the master unit) Transmission cycle 2 msec. (fixed) Data length byte MECHATROLINK-II Baud rate 1 Mbps Transmission distance 5 m max. Distance between stations 5 cm min. Transmission media MECHATROLINK cable (Model JEPMC-W63-x-E, Yaskawa Controls Co., Ltd.) Max. number of slaves 3 (The maximum number of slaves might change depending on the master unit. Refer to the manual of the master unit) Transmission cycle.5 msec., 1 msec., 1.5 msec., 2 msec., 4 msec., 8 msec. Data length bytes / 32 bytes selectable (Must choose identical data size for all stations on one network) 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-63 JAPAN Phone +81(6)6659-821 Fax +81(6)6659-851 E-mail info@m-system.co.jp EM-785-X Rev.1 P. 5 / 1

MECHATROLINK RELATED COMMANDS MECHATROLINK DATA LINK LAYER COMMAND DESCRIPTIONS The R7ML, Intelligent I/O, performs the connection-type communications according to MECHATROLINK protocol. The following tables explain Data Link Layer Commands supported by the R7ML. MDS Command (4H) Data Format MDS (4H) S () (9H) Message Data Search (MDS) Command Read the ID from the slave station S () Response to MDS 1 ID1 (H) 2 ID2 (8H) Intelligent I/O specified 3 4 5 6 7 8 9 1 11 12 13 14 15 16 Byte through are always in the 32-byte mode. These bytes are unavailable for MECHATROLINK-I, or MECHATROLINK-II in the - byte mode. CDRW Command (3H) Data Format CDRW (3H) ACK (1H) Cyclic Data Read/Write (CDRW) Command Link transmission Acknowledge (ACK) Positive response to CDRW 1 CMD RCMD CMD Application Layer Command RCMD Response to Application Layer Command 2 16 Byte 2 through 16 depend upon the Application Layer Command type. Byte through depend upon the Application Layer Command type. These bytes are unavailable for MECHATROLINK-I, or MECHATROLINK- II in the - byte mode. 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-63 JAPAN Phone +81(6)6659-821 Fax +81(6)6659-851 E-mail info@m-system.co.jp EM-785-X Rev.1 P. 6 / 1

MECHATROLINK APPLICATION LAYER COMMAND DESCRIPTIONS The following tables explain Application Layer Commands supported by the R7ML. NOP Command (H) Data Format CDRW (3H) ACK (1H) Cyclic Data Read/Write (CDRW) Command Link transmission Acknowledge (ACK) Positive response to CDRW 1 NOP (H) NOP (H) No Operation (NOP) Command Nothing is performed. 2 ALARM Error code See MECHATROLINK DATA DESCRIPTIONS 3 STATUS1 Status code See MECHATROLINK DATA DESCRIPTIONS 4 STATUS2 Status code See MECHATROLINK DATA DESCRIPTIONS 5 6 7 8 9 1 11 12 13 14 15 16 Byte through are always in the 32-byte mode. These bytes are unavailable for MECHATROLINK-I, or MECHATROLINK-II in the - byte mode. ID_RD Command (3H) Ddata Format CDRW (3H) ACK (1H) Cyclic Data Read/Write (CDRW) Command Link transmission Acknowledge (ACK) Positive response to CDRW 1 ID_RD (3H) ID_RD (3H) Read ID (ID_RD) Command Read out the device ID 2 ALARM Error code See MECHATROLINK DATA DESCRIPTIONS 3 STATUS1 Status code See MECHATROLINK DATA DESCRIPTIONS 4 STATUS2 Status code See MECHATROLINK DATA DESCRIPTIONS 5 DEVICE_ CODE DEVICE_ CODE Specifies the device code H Product s model number FH Vendor code 6 OFFSET OFFSET Indicates where to start reading in the specified device ID 7 SIZE SIZE Number of byte counts to read 8 ID1 ASCII or binary data 9 ID2 ASCII or binary data 1 ID3 ASCII or binary data 11 ID4 ASCII or binary data 12 ID5 ASCII or binary data 13 ID6 ASCII or binary data 14 ID7 ASCII or binary data 15 ID8 ASCII or binary data 16 Byte through are always in the 32-byte mode. These bytes are unavailable for MECHATROLINK-I, or MECHATROLINK-II in the - byte mode. 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-63 JAPAN Phone +81(6)6659-821 Fax +81(6)6659-851 E-mail info@m-system.co.jp EM-785-X Rev.1 P. 7 / 1

CONNECT Command (EH) Data Format CDRW (3H) ACK (1H) Cyclic Data Read/Write (CDRW) Command Link transmission Acknowledge (ACK) Positive response to CDRW 1 CONNECT (EH) CONNECT (EH) Establish Connection (CONNECT) Command Requests to establish connection to MECHATROLINK 2 ALARM Error code See MECHATROLINK DATA DESCRIPTIONS 3 STATUS1 Status code See MECHATROLINK DATA DESCRIPTIONS 4 STATUS2 Status code See MECHATROLINK DATA DESCRIPTIONS 5 VER VER Application Layer version number 1H MECHATROLINK-I 21H MECHATROLINK-II 6 COM_MODE COM_MODE Communication mode H -byte mode 8H 32-byte mode 7 COM_TIME COM_TIME Communication cycle (milliseconds) MECHATROLINK-I Multiples of two (2) MECHATROLINK-II Integral multiples of the transmission cycle 8 9 1 11 12 13 14 15 16 DISCONNECT Command (FH) Data Format Byte through are always in the 32-byte mode. These bytes are unavailable for MECHATROLINK-I, or MECHATROLINK-II in the -byte mode. CDRW (3H) ACK (1H) Cyclic Data Read/Write (CDRW) Command Link transmission Acknowledge (ACK) Positive response to CDRW 1 DISCONNECT (FH) DISCONNECT (FH) Release Connection (DISCONNECT) Command Requests to release connection to MECHATROLINK 2 ALARM Error code See MECHATROLINK DATA DESCRIPTIONS 3 STATUS1 Status code See MECHATROLINK DATA DESCRIPTIONS 4 STATUS2 Status code See MECHATROLINK DATA DESCRIPTIONS 5 6 7 8 9 1 11 12 13 14 15 16 Byte through are always in the 32-byte mode. These bytes are unavailable for MECHATROLINK-I, or MECHATROLINK-II in the -byte mode. 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-63 JAPAN Phone +81(6)6659-821 Fax +81(6)6659-851 E-mail info@m-system.co.jp EM-785-X Rev.1 P. 8 / 1

DATA_RWA Command (5H) Data Format CDRW (3H) ACK (1H) Cyclic Data Read/Write (CDRW) Command Link transmission Acknowledge (ACK) Positive response to CDRW 1 DATA_RWA (5H) DATA_RWA (5H) Data Read/Write_A (DATA_RWA) Command Refreshes I/O data 2 ALARM Error code See MECHATROLINK DATA DESCRIPTIONS 3 STATUS1 Status code See MECHATROLINK DATA DESCRIPTIONS 4 STATUS2 Status code See MECHATROLINK DATA DESCRIPTIONS 5 CH1 OUT LO CH1 IN LO CHx OUT Output data See MECHATROLINK DATA DESCRIPTIONS 6 CH1 OUT HI CH1 IN HI CHx IN Input data See MECHATROLINK DATA DESCRIPTIONS 7 CH2 OUT LO CH2 IN LO 8 CH2 OUT HI CH2 IN HI 9 CH3 OUT LO CH3 IN LO 1 CH3 OUT HI CH3 IN HI 11 CH4 OUT LO CH4 IN LO 12 CH4 OUT HI CH4 IN HI 13 EXT OUT LO EXT IN LO EXT OUT Extension output data See MECHATROLINK DATA DESCRIPTIONS 14 EXT OUT HI EXT IN HI EXT IN Extension input data See MECHATROLINK DATA DESCRIPTIONS 15 STATUS LO R7ML status See MECHATROLINK DATA DESCRIPTIONS 16 STATUS HI Byte through are always in the 32-byte mode. These bytes are unavailable for MECHATROLINK-I, or MECHATROLINK-II in the -byte mode. MECHATROLINK APPLICATION LAYER DATA DESCRIPTIONS Alarm Error Codes Errors detected at the slave are set at ALARM in the response and sent to the master. ERROR CODE DESCRIPTION CLASSIFICATION H Normal status ---- 1H Invalid Command Command is not supported. Warning 2H Command Not Allowed Command execution conditions are not met. Warning 3H Invalid Data Data in the command is not correct. Warning 4H Synchronization Error Alarm STATUS1 Bit Allocations Alarm/Warning classification and status information are set at STATUS1 in the response and sent to the master. Bit DEFINITION DESCRIPTION Alarm Bit Normal, 1 Alarm 1 Warning Bit Normal, 1 Warning 2 Command Ready Bit Command cannot be accepted (busy), 1 Command can be accepted (ready) 3...7 Unused ---- STATUS2 Reserved for future use Input Data Input data to be sent from the slave to the master are set in the response. With an output module, output data in the command are repeated and sent back to the master. ID DESCRIPTION REMARKS CH1 IN LO CH1 data, low 8 bits R7ML-DA16 Bit through 7 data are set. R7ML-DC16x, R7ML-YS2, R7ML-YV2 Output data are repeated. CH1 IN HI CH1 data, high 8 bits R7ML-DA16 Bit 8 through 15 data are set. R7ML-DC16x, R7ML-YS2, R7ML-YV2 Output data are repeated. CH2 IN LO CH2 data, low 8 bits R7ML-DA16, R7ML-DC16x Unused R7ML-YS2, R7ML-YV2 Output data are repeated. CH2 IN HI CH2 data, high 8 bits R7ML-DA16, R7ML-DC16x Unused R7ML-YS2, R7ML-YV2 Output data are repeated. CH3 IN LO CH3 data, low 8 bits R7ML-DA16, R7ML-DC16x, R7ML-YS2, R7ML-YV2 Unused CH3 IN HI CH3 data, high 8 bits R7ML-DA16, R7ML-DC16x, R7ML-YS2, R7ML-YV2 Unused CH4 IN LO CH4 data, low 8 bits R7ML-DA16, R7ML-DC16x, R7ML-YS2, R7ML-YV2 Unused CH4 IN HI CH4 data, high 8 bits R7ML-DA16, R7ML-DC16x, R7ML-YS2, R7ML-YV2 Unused 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-63 JAPAN Phone +81(6)6659-821 Fax +81(6)6659-851 E-mail info@m-system.co.jp EM-785-X Rev.1 P. 9 / 1

Output Data Output data to be sent from the master to the slave are set in the command. Unused with all input modules. ID DESCRIPTION REMARKS CH1 OUT CH1 data, low 8 bits R7ML-DC16x Bit through 7 data are set. CH1 OUT HI CH1 data, high 8 bits R7ML-DC16x Bit 8 through 15 data are set. CH2 OUT LO CH2 data, low 8 bits R7ML-DC16x Unused CH2 OUT HI CH2 data, high 8 bits R7ML-DC16x Unused CH3 OUT LO CH3 data, low 8 bits R7ML-DC16x, R7ML-YS2, R7ML-YV2 Unused CH3 OUT HI CH3 data, high 8 bits R7ML-DC16x, R7ML-YS2, R7ML-YV2 Unused CH4 OUT LO CH4 data, low 8 bits R7ML-DC16x, R7ML-YS2, R7ML-YV2 Unused CH4 OUT HI CH4 data, high 8 bits R7ML-DC16x, R7ML-YS2, R7ML-YV2 Unused Extension Input Data R7ML-DC16D Input data of the extension module to be sent from the slave to the master are set in the response. With an output extension module, output data in the command are repeated and sent back to the master. ID DESCRIPTION REMARKS EXT IN LO Extension data, low 8 bits R7ML-EA16, R7ML-EA8 Bit through 7 data are set. R7ML-EC16x, R7ML-EC8x Output data are repeated. EXT IN HI Extension data, high 8 bits R7ML-EA16 Bit 8 through 15 data are set. R7ML-EC16x Output data are repeated. R7ML-EA8, R7ML-EC8x Unused Extension Output Data Output data to be sent from the master to the slave are set in the command. Unused with all input modules. ID DESCRIPTION REMARKS EXT OUT LO Extension data, low 8 bits R7ML-EC16x Bit through 7 data are set. R7ML-EC8x Bit through 7 data are set. EXT OUT HI Extension data, high 8 bits R7ML-EC16x Bit 8 through 15 data are set. R7ML-EC8x Unused R7ML Status Data Status data to be sent from the slave to the master are set in the response. Refer to I/O DATA DESCRIPTIONS. I/O DATA DESCRIPTION DISCRETE OUTPUT 15 Output Output 1 Output 2 Output 3 Output 7 Output 8 Output 15 OFF 1ON 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-63 JAPAN Phone +81(6)6659-821 Fax +81(6)6659-851 E-mail info@m-system.co.jp EM-785-X Rev.1 P. 1 / 1