GE Energy Connections Grid Solutions MMLZ. Technical Data Sheet Auxiliary Modules. Publication reference: MMLZ/EN TDS/B

Similar documents
MMLG 01, 02, 03, 04 MMLB01

MMLB 01/MMLB 02 Multi-finger Test Plug/ Single-finger Test Plug Technical Data MMLB_EN_TD_A

Type MVTT 14 and MVTT 15: Static Digital Time delay relays

Earth-fault Relay SPAJ 110 C. Product Guide

Feeder protection relay SPAA 121 C. Product Guide

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

satech TSB-14 MAIN FEATURES

REYROLLE 2RMLG. Operating Recommendations

Combined Overcurrent and Earth-fault Relay SPAJ 140 C. Product Guide

MiCOM Agile P99x. Grid Solutions. Testing & Commissioning. Test Block, Multi-finger Test Plug and Single-finger Test Plug. Design Flexibility

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1

Combined Overcurrent and Earth-fault Relay SPAJ 141 C. Product Guide

HID. GE Consumer & Industrial Multilin. High Impedance Differential Module Instruction manual GEK Copyright 2005 GE Multilin

Residual overvoltage relay

Feeder protection relay SPAA 341 C. Product Guide

Feeder protection relay

Arc protection relay. Features Three-phase overcurrent function. Application

RMS Product Presentation

IRI1-ES Sensitive Earth Fault Current Relay. Manual IRI1-ES (Revision A)

Sensitive definite time or inverse time earth-fault stage for back-up residual earthfault

Title Power Supply Units for Signalling Equipment - DC (Regulated & Filtered) Units. Reference Number SPS 30 - (RIC Standard: SC SP)

7XG225-3RMLG Test Block System Answers for infrastructure & cities.

Universal Power Supplies

Table 1 Relay Model and Function

High-Tech Range IRI1-ES- Sensitive Earth Fault Current Relay

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

High impedance protection relay

High Impedance Protection Relay SPAE010, SPAE011. Product Guide

Defender B Board. Make The Switch

DGBV-EP DIGITAL GENERATOR AND GENERATOR-TRANSFORMER UNIT PROTECTION. Field of application

RT4F-120V/20A-WAC RECTIFIER

RT4B-110V/12A RECTIFIER

MODEL SW6000 & SM6100 CENELEC INSTRUCTIONS

Synchro-check relay. Application

3RV1 Circuit-Breakers

B60 Domestic Voltage Optimisation Unit

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description

1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection

TeSys IEC Contactors and Overload Relays

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

Arc protection relay. Features Three-phase overcurrent function. Application

7SG26 Tau Autoreclose and synchronization Answers for energy

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

70 SERIES. Line monitoring relay

Switch Disconnectors, Main and EMERGENCY-STOP Switches

////// SUBSTATIONS. DC Switchgear Range. Type MBS (IEEE/ANSI standards)

DTRV-EP. COMPLEX DIGITAL PROTECTION FOR 120 kv / MEDIUM VOLTAGE TRANSFORMERS. Application field

SIGMA D++ / SIGMA D+ / SIGMA D Directional Fault Indicator

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

Autodaptive Capacitor Control M 2501B

MESP TECHNICAL SPECIFICATION FOR A RECTIFIER UNIT CONTROL & PROTECTION SYSTEM FOR USE IN THE 1500V DC TRACTION SYSTEM

Single Phase Systems-North American PC125/PC420 Series

Zelio Control-modular measurement and control relays 1

K1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm

Company Directive ENGINEERING SPECIFICATION EE SPEC: 136

IMP/ 001 / 014 Policy for the Protection of Distribution Networks

VersaPoint I/O Module

INSTITUTE OF TESTING AND CERTIFICATION (INDIA) PVT. LTD.

MRC1800H SERIES. Output. Features

BE1-50/51M TIME OVERCURRENT RELAY ADVANTAGES

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077

Session Five: IEC61850 Based Process Bus Protection Solution for Remote Located Power Transformers

Circuit Breakers Type CTI 25M, CTI 45MB

RT4F-110V/25A RECTIFIER

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

Residual Current Devices drcm Digital

Innovation on Medium Voltage Switchgear

Devices raised mounting

VCL-TP, Teleprotection Equipment With Trip Counter Display Panel

K1B004TLH cam switch - 1 pole A - screw mounting

MAINS DISTRIBUTION UNIT MDU14-CO

E-STOP relay, safety gate monitor

Room Temperature Controller

Bus Protection Application Challenges

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

DRS-LA413. Circuit Breaker Failure Relay. Operating Principle DRS-LA413. Operating Principle. Revision: 2 from Dwg.No.: DIL

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

GE Grid Solutions. MiCOM S1 Agile. Release Notes. Publication reference: S1Agile/EN RN/I.1

K1D012ULH cam changeover switch - 2-pole A - screw mounting

E-STOP relays, safety gate monitors

1492-SP Supplementary Protectors

Voltage regulator. SPAU 341 C 1MRS MBG Issued: July 1998 Status: Revised Version: C/ Data subject to change without notice

SEL-734B Data Sheet. Advanced Monitoring and Control System. Major Features and Benefits

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

LED DRIVERS. CLi10/CLi15 (10/15 watt) DALI/Touch/Corridor Dimmable

MRA1 Trip circuit supervision. Manual MRA1 (Revision A)

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

E-STOP relays, safety gate monitors

Auxiliary Units for 7SR23 High Impedance Protection Energy Management

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

GRD130 - FEATURES APPLICATION

TeSys protection components

Installation, Operation and Maintenance Instructions

SIRCO Load break switches for power distribution from 125 to 5000 A

Valve and Case Expansion Monitor Specifications

DEEP SEA ELECTRONICS PLC

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

Relays for Various Protection Applications / 7SV600

Transcription:

GE Energy Connections Grid Solutions MMLZ Technical Data Sheet Auxiliary Modules Publication reference: MMLZ/EN TDS/B

MMLZ Technical Data Sheet FEATURES Wide choice of application specific models Fully compatible with other Midos equipment Suitable for rack or panel mounting Figure 1: Typical MMLZ module (MMLZ 07 shown) MMLZ_EN TDS_B 1

Technical Data Sheet MMLZ INTRODUCTION The MMLZ range of modules consists of various non-protective devices, that have been accommodated in standard Midos cases. The modules, each of which has been designed for a specific purpose, are fully compatible with the Midos range. MMLZ01 MMLZ02 MMLZ03 MMLZ04 MMLZ05 MMLZ06 MMLZ07 MMLZ08 MMLZ09 MMLZ10 MMLZ11 MITZ01 MMLZ 15 MMLZ 16 MMLZ18 MMLZ 19 MMLZ 20 MMLZ 21 MMLZ 22 MMLZ 23 MMLZ 24 MMLZ 25 MMLZ 26 MMLZ 27 MMLZ 28 MMLZ 29 MMLZ 31 Models Available Acceleration test module Blocking test module Protection in/out module Zone 2 override/normal switch module Blocking in/out module High impedance busbar switch module Channel test switch Auto reclose switching module Interrupt breaker fail switch module Protection in/out selector switch module Loopback test facility Auto-reclose switching module Auto-reclose switching module Channel test switch - send only Channel test switch - receive only Channel test switch - intertrip Channel test switch - intertrip Channel test switch - blocking Channel test switch - triangulated intertrip Channel test switch - receive intertrip Channel test switch - single end intertrip Channel selector switch Channel selector switch Switching module - K/MiCOM schemes Switching module and CB indication - K/MiCOM schemes Switching module and CB indication - K/MiCOM schemes 2 MMLZ_EN TDS_B

MMLZ Technical Data Sheet APPLICATIONS The MMLZ modules cater for a variety of applications with each individual module being designed for a specific function. A selection of switch modules is available for use in, for example, distance, blocking, auto-reclose, breaker fail or high impedance busbar switching schemes, whilst others have been designed for on-site testing of signalling equipment. The switches may be multi-way multi-position and can be spring return depending on the module type. Similarly, the switches may be key operated or fitted with an adjacent key operated locking device. Functions For the convenience of the following descriptions, certain MMLZ modules are grouped together according to similarity of design. The MMLZ 01 module is designed to provide a convenient method of performing on-site testing of different signalling equipment. The front plate (see Figure 2(a)) contains test plug sockets, for external inputs, and a 4-position rotary switch to select either normal operation or one MMLZ 01 acceleration test module of three alternative test modes. This switch is locked into its selected position and is only released by means of its adjacent key operated cylinder lock. The test signal is transmitted by momentary action pushbutton operation and two indicator lamps to show test status. The MMLZ 01 circuit diagram is shown in Figure 4. The MMLZ 02 is similar in layout (see Figure 2(b)) and function to the MMLZ 01, except for its rotary switch which has three positions. The MMLZ 02 blocking test module three position rotary switch selects either normal operation or one of two test modes. The MMLZ 02 circuit diagram is shown in Figure 5. The MMLZ 07 differs from the MMLZ 01 in that it is used for testing an intertwining channel. Figure 1(g) shows the front plate layout which MMLZ 07 channel test switch module differs from the other two because the test signal received light is omitted. The MMLZ 07 diagram is shown in Figure 10). MMLZ 03 protection in/out switch module MMLZ 10 protection in/out selector switch module MMLZ 04 zone 2 override normal/switch module MMLZ 05 blocking in/out module MMLZ 06 high impedance busbar switch module The front plate layouts of these key operated switching modules are shown in Figures 2(c) and 2(j) respectively. The MMLZ 03 module consists of a three position spring return to neutral switch whereas the MMLZ 10 has a two position switch. The MMLZ 03 can be arranged to operate an electrically reset relay such as the MVAJ 34. The MMLZ 10 is intended to be used without follower relays to provide direct isolation of circuits. The key can only be removed from the MMLZ 03 in the neutral position, whereas it is removable from either position in the MMLZ 10. The circuit diagrams of the switching modules are shown in Figures 6 and 13. The two modules can be used in, for example, distance protection schemes, and are identical, except for their labelling. The front plate layouts of the modules are shown in Figures 2(d) and 2(e) respectively. Each module comprises one key operated three position, spring return to neutral switch that can be arranged to operate an electrically reset relay such as the MVAJ 34. The key is removable in the neutral position. Circuit diagrams for the modules are shown in Figures 7 and 8. The MMLZ 06 is suitable for in/out switching in a high impedance busbar scheme by means of a two position switch and is normally used without a follower relay. The front plate layout and circuit diagram are shown in Figures 2(f) and 9 respectively. Illuminated indication of the switch position is provided. MMLZ_EN TDS_B 3

Technical Data Sheet MMLZ MMLZ 08 auto reclose switch module MMLZ 09 interrupt breaker fail switch module MMLZ 11 - MITZ 01 loopback test facility Functions The module is suitable for auto-reclose in/out switching on a one and a half switch arrangement where a separate switching relay is not fitted. The front plate layout is shown in Figure 2(h). The In/Out switch has two positions and is key operated. Two further non key operated, spring-return switches, each having two positions, are included to separately reset the lockout features associated with the two circuit breakers. The circuit diagram is shown in Figure 11. This module can be used to block the breaker fail circuit to prevent, for example, back trips during testing. The MMLZ 09 has a two-position stayput switch and operates without a follower relay to provide direct isolation of the circuit. The module has three labelling variations, depending on application, which are shown in Figure 2(i). See Figure 12 for the circuit diagram. The MMLZ 11 is used with the MITZ 01 interface unit. The interface unit allows the LFCB digital current differential relay to be connected through optical fibres to a remote multiplexer which has a CCITT G.703 co-directional interface. The MMLZ 11 is positioned in the G.703 interface immediately after the MITZ 01 unit. It enables the LFCB, the MITZ 01 and the cross-site optical link to be tested in a loopback mode. This is achieved by removal of four U-links from the normal position, (see front plate layout in Figure 2(l)) and insertion into the test position. The MMLZ 11 and MITZ 01 combination can be applied to each of a two-ended feeder whereas for a three-ended feeder, two MMLZ 11 and MITZ 01 sets are required per line end. The module circuit diagram is shown in Figure 14. MMLZ 15 and MMLZ 16 switching module MMLZ 26 and MMLZ 27 channel selector switches Switches The MMLZ 15 consists of 3 rotary switches each with 2 positions. It is used in NGC TPS 12/10 auto-reclose scheme. MMLZ 16 differs in that it has only 2 switches. The MMLZ 15 and MMLZ 16 front plate layouts are shown in Figure 2(k) and 2(m) respectively. See Figures 15 and 16 for the circuit diagrams. MMLZ 26 and MMLZ 27 are simple 4 and 3 position selector switches respectively. The switches are locked into the selected position and can only be released by the adjacent key operated lock. Both switches were designed for use with a power line carrier intertripping scheme. The MMLZ 26 and MMLZ 27 front plate layouts are shown in Figures 3(u) and 3(v) respectively. See Figures 25 and 26 for the circuit diagrams. 4 MMLZ_EN TDS_B

MMLZ Technical Data Sheet MMLZ 28, MMLZ 29 and MMLZ 31 switching modules Switches MMLZ 28 and MMLZ 29 have both been designed for use with K Range and MiCOM busbar schemes. The MMLZ 28 has 2 key operated switches. Each switch has 2 positions. One is Busbar/CB Fail - In/Out and the other is Transfer trip - Master/Follower. For each switch the key is removable in either position. The MMLZ 29 consists of 2 key operated switches. Each switch has 3 positions. The top switch has 2 user definable positions, the central position being Off and has a maintained action. The positions in which the key can be removed and the label inscription can be selected by the user at order stage. The lower switch is Trip/Off/Close and has a momentary action. The key can only be removed in the Off position. There is also a Circuit Breaker position mimic. The MMLZ 28 and MMLZ 29 front plate layouts are shown in Figures 3(w) and 3(x) respectively. See Figures 27 and 28 for the circuit diagrams. The MMLZ 31 consists of 2 key operated switches. Each switch has 3 positions, the top switch is Trip/Normal/Close and has a momentary action. The key can only be removed in the Normal position. There is also a circuit breaker mimic. The bottom switch is Local/Off/Remote and has a maintained action. The key can be removed in all positions. Channel Test Switches Channel test switches provide facilities for testing the correct operation of a channel and some also enable propagation time tests to be carried out. The MMLZ 01 module is designed to provide a convenient method of performing on-site testing of different signalling equipment. The front plate (see Figure 2(a)) contains test plug sockets, for external inputs, and a 4-position rotary switch to select either normal operation or one of three alternative test modes. This switch is locked into its selected position and is only released by means of its adjacent key operated cylinder lock. The test signal is transmitted by momentary action pushbutton operation and two indicator lamps to show test status. The MMLZ 01 circuit diagram is shown in Figure 4. MMLZ 18 channel test switch - intertrip schemes - send only MMLZ19 channel test switch - intertrip schemes - receive only MMLZ 20 and MMLZ 21 channel test switch - intertrip MMLZ 18 - send only. The front plate consists of 1 key operated 2 position switch - Test/Normal, a momentary action pushbutton Signal Send to transmit the test signal and 2 indicator lamps Normal and Channel on Test to indicate status. The key can be removed with the switch in either position. MMLZ 19 - Receive only. The MMLZ 19 differs from the MMLZ 18 in that it has no pushbutton. The MMLZ 18 and MMLZ 19 front plate layouts are shown in Figures 3(n) and 3(o) respectively. See Figures 17 and 18 for the circuit diagrams. MMLZ 20 and MMLZ 21 consist of 1 key operated 2 position switch - Test/Normal and 2 indication lamps to indicate status. The key can be removed with the switch in either position. These MMLZs are used for testing signalling channels in intertripping schemes without initiating the intertrip receive trip relays. Both are used in NGC TPS 5/33 schemes. MMLZ 20 is used in Intertrip 003 and MMLZ 21 is used in Intertrip 004. The MMLZ 20 and MMLZ 21 front plate layouts are shown in Figure 3(p). See Figures 19 and 20 for the circuit diagrams. MMLZ_EN TDS_B 5

Technical Data Sheet MMLZ MMLZ 22 channel test switch - distance blocking schemes MMLZ 23 channel test switch - triangulated intertrip scheme MMLZ 24 channel test switch - receive intertrip scheme MMLZ 25 channel test switch - intertrip Channel Test Switches The MMLZ 22 consists of a momentary pushbutton Channel Test and 2 indication lamps Carrier Test Ready and Test Signal Received. It is used in NGC TPS 5/33 schemes SHNB Block 002 and THR Block 002. The MMLZ 22 front plate layout is shown in Figure 3(q). See Figure 21 for the circuit diagram. The front plate of the MMLZ 23 consists of a 4 position rotary selector switch comprising 1 normal and 3 test positions. The switch is locked into the selected position and can only be released by the adjacent key operated lock. There is a momentary action pushbutton to transmit the test signal and an indicator lamp Channel on Test. There are also 2 test sockets - Initiate and Reflex. It is used in NGC TPS 5/33 scheme Intertrip 005. The MMLZ 23 front plate layout is shown in Figure 3(r). See Figure 22 for the circuit diagram. The MMLZ 24 differs from the MMLZ 23 in that the selector switch has only 3 positions comprising 1 normal and 2 test positions. This switch is used in a scheme where the receive trip relays are operated when the channel is tested but not when the timing test is carried out. It is used in NGC TPS 5/33 scheme Intertrip 007. The MMLZ 24 front plate layout is shown in Figure 3(s). See Figure 23 for the circuit diagram. The front plate of the MMLZ 25 consists of a 3 position selector switch comprising 1 normal and 2 test positions, a momentary action pushbutton to transmit the test signal and an indicator lamp Channel on Test. There are also 2 test sockets - Send Start and Receive Output. The switch is locked into the selected position and can only be released by the adjacent key operated lock. It is used in single end intertripping schemes. The MMLZ 25 front plate layout is shown in Figure 3(t). See Figure 24 for the circuit diagram. 6 MMLZ_EN TDS_B

MMLZ Technical Data Sheet HARDWARE DESCRIPTION The modules are housed in Midos cases, suitable for either rack or panel mounting as shown in Figure 29. Standard Midos terminal blocks are located at the rear of the module providing connection for all input and output circuits. MMLZ_EN TDS_B 7

Technical Data Sheet MMLZ Figure 2: Frontplate layouts MMLZ 01 to 16 8 MMLZ_EN TDS_B

MMLZ Technical Data Sheet Figure 3: Frontplate layouts MMLZ 18 to 31 MMLZ_EN TDS_B 9

Technical Data Sheet MMLZ Figure 4: MMLZ 01 acceleration test module (typical only) Figure 5: MMLZ 02 blocking test module 10 MMLZ_EN TDS_B

MMLZ Technical Data Sheet Figure 6: MMLZ 03 protection in/out switch module Figure 7: MMLZ 04 zone 2 override normal/switch module MMLZ_EN TDS_B 11

Technical Data Sheet MMLZ Figure 8: MMLZ 05 blocking in/out module Figure 9: MMLZ 06 high impedance busbar switch module 12 MMLZ_EN TDS_B

MMLZ Technical Data Sheet Figure 10: MMLZ 07 channel test switch module (typical only) Figure 11: MMLZ 08 auto reclose switch module MMLZ_EN TDS_B 13

Technical Data Sheet MMLZ Figure 12: MMLZ 09 interrupt breaker fail switch module Figure 13: MMLZ 10 protection in/out selector switch module (typical only) 14 MMLZ_EN TDS_B

MMLZ Technical Data Sheet Figure 14: MMLZ 11 - MITZ 01 loopback test facility Figure 15: MMLZ switching module MMLZ_EN TDS_B 15

Technical Data Sheet MMLZ Figure 16: MMLZ 16 channel selector switches Figure 17: MMLZ 18 channel test switch - intertrip schemes - send only 16 MMLZ_EN TDS_B

MMLZ Technical Data Sheet Figure 18: MMLZ 19 channel test switch - intertrip schemes - receive only Figure 19: MMLZ 20 channel test switch - intertrip MMLZ_EN TDS_B 17

Technical Data Sheet MMLZ Figure 20: MMLZ 21 channel test switch - intertrip Figure 21: MMLZ 22 channel test switch - distance blocking schemes 18 MMLZ_EN TDS_B

MMLZ Technical Data Sheet Figure 22: MMLZ 23 channel test switch - triangulated intertrip schemes Figure 23: MMLZ 24 channel test switch - receive intertrip scheme MMLZ_EN TDS_B 19

Technical Data Sheet MMLZ Figure 24: MMLZ 25 channel test switch - intertrip Figure 25: MMLZ 26 channel selector switches 20 MMLZ_EN TDS_B

MMLZ Technical Data Sheet Figure 26: MMLZ 27 channel selector switches Figure 27: MMLZ 28 switching modules MMLZ_EN TDS_B 21

Technical Data Sheet MMLZ Figure 28: MMLZ 29 switching modules 22 MMLZ_EN TDS_B

MMLZ Technical Data Sheet RATINGS Nominal current (In) AC Current 5 A Auxiliary Voltage (Vx) Auxiliary voltage (dc) 24V, 48V, 110V Recommended maximum fuse rating 6A Red Spot fuse or equivalent Maximum continuous current Power rating for 1 x 106 operations: Auxiliary voltage Vdc power (W) High Voltage (Dielectric) Withstand Standard Contacts 5 A 24 Vdc 100 W 48 Vdc 85 W 110 Vdc 65 W IEC Compliance IEC 60255-5: 1977 Between independent circuits, with terminals on each independent circuit connected together Between all case terminals and the case earth Across normally open contacts 2 kv ac rms for 1 minute 2 kv ac rms for 1 minute 1 kv ac rms for 1 minute High Impulse Voltage IEC Compliance IEC 60255-5: 1977 Between all independent circuits Between all terminals of the same circuit (except output contacts) Between all terminals connected together and case earth Front time: 1.2 µs, Time to half-value: 50 µs, Peak value: 5 kv, 0.5 J Front time: 1.2 µs, Time to half-value: 50 µs, Peak value: 5 kv, 0.5 J Front time: 1.2 µs, Time to half-value: 50 µs, Peak value: 5 kv, 0.5 J Across normally open outgoing contacts Switch Contacts IEC 60158-1 500V ac rms and 500V dc for 1 minute MMLZ_EN TDS_B 23

Technical Data Sheet MMLZ ENVIRONMENTAL CONDITIONS Ambient Temperature Range Compliance IEC 60068-2-1 Storage and transit temperature range IEC 60068-2-2 (-25 C to +70 C) Operating temperature range (96 hours) -25 C to +55 C Ambient Humidity Range Compliance IEC 60068-2-3 Durability 56 days at 93% relative humidity and +40 C Compliance Enclosure Protection IEC 60529 IP50 (dust protected) Mechanical Environment Compliance IEC 60255-21-1 Class 1, BS 142 Sec. 1.5.1 Vibration Durability 0.5g between 60-150Hz, 0.07 mm peak-peak between 10-60Hz Contacts 3 x 106 operations For Standard Safety Statements for Protection and Control Relays refer to Publication R5948. 24 MMLZ_EN TDS_B

MMLZ Technical Data Sheet Figure 29: Case outline sizes 2, 4 and 6 Module type DC auxiliary voltage Information Required with Order MMLZ 01, 02, 03 etc. Where applicable MMLZ_EN TDS_B 25

Imagination at work Grid Solutions St Leonards Building Redhill Business Park Stafford, ST16 1WT, UK +44 (0) 1785 250 070 www.gegridsolutions.com/contact 2017 General Electric. All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited. MMLZ/EN TDS/B