Proximity Positioner. ICoT. Valve Monitoring and Control Products WESTLOCK

Similar documents
VVP10-H HART VALVE POSITIONER. Great Performance, Compact, Robust in Severe Conditions* HART 7 Communication Protocol. Electronic Coil Technology

FIELDVUE DVC6200 and DVC6200f Digital Valve Controller Management of Change Guide

DVC2000 Series FIELDVUE Digital Valve Controllers

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual

Series 3731 TROVIS SAFE Electropneumatic Ex d Positioner

CHRONOS IDP INTEllIGENT DIGITAl POSITIONER FOR CONTROl VAlVES

Series 3731 Type Electropneumatic Ex d Positioner with HART communication

Series 3730 Electropneumatic Positioner Type

SVI II ESD. SIL3 Partial Stroke Test Device October 2007 BW5000-ESD. The only SIL3 Smart ESD device that is live during and after a shutdown.

2-IQ Series Smart Valve Positioners

Digital EPIC D460/D470 For Rotary, Linear and Standard Applications Operating Manual

TECHNICAL BULLETIN. Logix 500si Series Digital Positioner. Experience In Motion FCD LGENTB /05

Foundation Fieldbus 5400-IS ICoT Positioner

VALVE NETWORKING MONITORING AND CONTROL. Monitoring and Control Products & CApabilities

Series 3730 Electropneumatic Positioner Type with HART communication and pressure sensors

Type i2p-100 Electro-Pneumatic Transducer

Data Sheet T 8394 EN. Series 3725 Type 3725 Electropneumatic Positioner

Fisher FIELDVUE DVC2000 Digital Valve

Series 3793 TROVIS SAFE 3793 Electropneumatic Positioner with HART communication

Do not open when energized or when an explosive atmosphere is present. Electrostatic hazard, clean only with damp cloth.

Series 3731 Electropneumatic Ex d Positioner Type with FOUNDATION TM Fieldbus communication

Data Sheet T 8493 EN. Series 3793 TROVIS 3793 Electropneumatic Positioner with HART communication

Series 3730 Type Electropneumatic Positioner

Installation & Operating Instructions for SmartCal Valve Positioner

TECHNICAL BULLETIN. Logix 500si Series Digital Positioner. Experience In Motion FCD LGENTB /13

AVID SmartCal Valve Positioner - Figure 793 Installation & Operating Instructions

Digital EPIC Control Transmitters Weatherproof, Intrinsically Safe - ATEX/IEC

II ESD. SIL3 Partial Stroke Test Device. The only SIL3 Smart ESD device that is live during and after a shutdown.

Series 3731 Type Electropneumatic Ex d Positioner with FOUNDATION TM fieldbus communication

PROFIBUS-PA Positioner Type 3785

Series 3730 Electropneumatic Positioner Type with PROFIBUS-PA communication

Valtek Logix Series Digital Positioner

Series 3730 Electropneumatic Positioner Type and Type with HART communication

Series 3730 Type Electropneumatic Positioner with HART communication and pressure sensors

Breaking the Limits of Analog Technology. Key attributes of the technology that makes FOUNDATION fieldbus suitable for process control

Series 3730 Type Electropneumatic Positioner

Electropneumatic Positioner Type and Type with HART communication

TPE 1464 Series Pressure Transducer

Series Electropneumatic Positioner Type and Type with HART communication

AccuTrak Rotary Position Monitors Weatherproof NEMA and IEC

T EN TROVIS Electropneumatic Positioner

VALVE ACCESSORIES & CONTROLS V100 POSITIONER VAC V100 SERIES POSITIONER SIMPLE DURABLE RELIABLE

AS-interface Network Card

Series 3730 Type Electropneumatic Positioner with PROFIBUS-PA communication

MTII4200 Level Transmitter Installation, Operation & Maintenance Instructions

Fisher i2p-100 Electro-Pneumatic Transducer

Fisher FIELDVUE DVC2000 Digital Valve

Data Sheet T EN

The TVC Positioner is designed to provide precise position control of rotary or linear hydraulic or pneumatic actuated valve systems.

HART Field Device Specification Fisher FIELDVUE DVC2000 Digital Valve

Series 3730 Electropneumatic Positioner Type and Type with HART communication

Series 3730 Type Electropneumatic Positioner

Type 330SA High-Performance Electric Actuator

Fisher i2p-100 Electro-Pneumatic Transducer

System 6000 Electropneumatic Converters (proportional valves) Electronic Controllers Signal Converters

Foundation Fieldbus optimized for FPSO - CAPEX. Jonas Berge, Emerson Process Management

Digital Positioner 8049

Data Sheet T EN

Series 3730 Type Electropneumatic Positioner with PROFIBUS-PA communication

MST2000 Loop Powered Multivariable SMARTFLOW Transmitter

Fisher 657 and 667 Size 30i - 76i Diaphragm Actuators

BA505C 2-wire 4/20mA manual setpoint station Issue 6

SRD991 Intelligent Positioner with HART, FoxCom, PROFIBUS-PA, FOUNDATION Fieldbus H1 or Without Communication

Installation and operating instructions

Your Global Flow Control Partner. Series 50 Valve Status Monitor Operation and Maintenance Manual

Level-Lance Model 5400A

SideControl Positioner

KOBOLD PDA Series Digital Pressure Transmitter

Rev 7 January DR5x1, 6DR5x2 (x = 0,1,2,3,5,6)

D3 Digital Positioner. PMV D3 Digital Positioner Product Information. A Flowserve Company

Product Data. Model 675 Shark Cage Submersible Level Transmitter ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS

Digital electropneumatic positioner

3200IQ Digital Positioner

HART. Actuator Control. Redefining Flow Control

Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid

SX90 Process Controller

Tachometer Panel, PE3

Instruction Manual EW2002-AP 06/10 Rev D. Putting You In Control SVI II AP. Digital Positioner With Remote Position Sensor

Actuators & Positioners Intelligent Positioners Field Mount Units / Accessories

Series 3730 Type Electropneumatic Positioner with HART communication

Project Execution Best Practices

Dual Module VCT. 5. Lexan Enclosure is Water & Corrosion Proof Contaminants will not affect the module as long as terminal strip is not immersed.

SRD Z Intelligent Positioner stainless steel (316L)

TM Process Instruments. Vivace Process Instruments is a company that provides products and services for industrial automation and control.

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

Intellis Network Control Monitors

Digital electropneumatic positioner

Table of Contents 1. Overview Installation...6

GE Energy. Masoneilan * Products SVI * II AP. Advanced Performance Digital Valve Positioner

Model 675 DREXELBROOK. Shark Cage Submersible Level Transmitter DATA SHEET. Description. Features. Applications.

High-precision valve control using intelligent positioners. sipart

Quick Start Guide v1.0

Fisher i2p-100 Electro-Pneumatic Transducer

Description: IRB-540 Robot with 6-axis Flexi-Wrist Manipulator, S4P Controller, Conveyor Tracking, and Analog Paint Regulation (APR)

TECHNICAL BULLETIN. Logix 3200IQ Digital Positioner. Experience In Motion FCD LGENTB /11

PAST PRESENT & FUTURE TRENDS IN INDUSTRIAL AUTOMATION

IHP24. Intelligent Hydraulic Positioner D HP- PL

Level Plus. Magnetostrictive Liquid Level Transmitters with Temposonics Technology. Accessories for liquid level transmitters Catalog

Output Signal. Temperature 22DTH-56M BACnet DC V, DC V. Electrical Data Power Supply DC V, ±10%, 0.7 W

VA-7700 Series. Electric Valve Actuators. Product Bulletin

Transcription:

Proximity Positioner UNLIKE CONVENTIONAL POSITIONERS, THE ICOT POSITIONER FEEDS BACK VALVE POSITION WITHOUT THE NEED FOR LINKAGES OR LEVERS. Non-contact position feedback is accomplished through the use of a proximity type solid state sensor Non-Contact Position Feedback Unlike conventional positioners, the (patent pending) feeds back accurate valve position without the need for linkages, levers, and rotary or linear seals. Position sensing is performed totally by non-contacting means, permitting use of advanced control strategies where knowledge of valve position is used in predictive and other algorithms. SENSOR

The Advantages of Non-Contact Position Feedback Integrated Position Transmitter The is available with an integrated 4- ma. position feedback transmitter. This cost effective feature eliminates the requirement for the purchase of externally mounted devices when knowledge of valve position is required at a remote location 4- ma -1% Intelligent Calibration, Local Keypad intelligent positioners are equipped with a HART interface or a 3-button membrane keypad for performing on-site electronic calibration. The AutoCal feature allows for simple zero and span adjustments as well as PID and transducer calibration. HART Protocol The positioner responds to HART commands for ease of calibration and provides intelligence for the control valve through a microprocessor based diagnostic system utilizing the HART protocol. Accurate measurement of valve stem position, input signal, and actuator pressure offer operating personnel a real-time perspective on the state of control at the valve. Remote Mount Capability Since valve position feedback to the positioner is accomplished by non-contacting means, the ICoT has the unique ability to be mounted remotely (up to a distance of 5 feet) from the device it is controlling. In the event the control valve is located in either a high vibration or extremely corrosive environment, the non-contact position feedback feature allows for isolated placement of the positioner.

System Overview A B A microprocessor, housed within an environmentally sealed canister, performs position sensor linearization, AutoCal, characterization for valve type, PID control, autotuning, HART information processing, and display management. An electropneumatic transducer, with internal diagnostic elements, converts the servo output signal into a pneumatic signal for directly driving valve actuators. C D Position feedback is accomplished by a non-contact Hall effect magnetic sensor. All rotary positioners are standardly equipped with a Beacon position monitor. Air lines are connected to a machined aluminum manifold having gauges, filters, and a self-contained mechanism for cleaning the transducer orifice. E F G For positioners not equipped with a HART interface, a 3-button membrane keypad is provided for performing on-site electronic calibration. A standard hand-held terminal (the HART Communicator) may be utilized for field operations in conjunction with a remote PC for maintenance information and documentation. A 3/64 channel HART multiplexer provides diagnostic interfacing for multiple positioners. D D B C E A OPTIONS AND ACCESSORIES 4- ma Position Transmitter Proximity Position Sensors Solenoid Valves 4

System Overview DIAGNOSTICS Plant operating personnel are given a real-time perspective on the state of control at the valve, including a view into operating integrity and emerging alarm conditions. Early-warning diagnostic information is constantly being updated to assist production scheduling and maintenance personnel. Cornerstone Window Status Terminate Help HART Comm Instrument communication: Intelligent Modem Unit on Com 1 Instrument Vendor: Model: Tag: ICoT 43 VP3 Positioner-43 ID# Date: 8176 1 June 1 9 Cal Scheme: Standard 8 Range: - 1% 7 Description: 4H 6 CLOSING 5 OPENING 4 % OPENING OFFSET DUE TO FRICTION 3 1 4 6 8 1 1 14 16 18 INPUT SIGNAL (ma) F F G LOOP CONTROLLER DCS A preventive maintenance and data logging system, in parallel with the 4- ma loops, performs online diagnostics of control valves with automatic record keeping for documentation purposes. The HART communications capability of the positioner, coupled with the HPORT TM multiplexer and Cornerstone TM control valve specific software, provides operating personnel the opportunity of implementing customized preventive maintenance programs. It additionally simplifies adherence to occupational health and safety requirements mandated by government regulations. HPORT is a trademark of ARCOM Control Systems, Inc. CORNERSTONE is a trademark of Applied System Technologies, Inc.

Non-Contact Position Feedback ROTARY CONTROL Since valve position sensing is performed totally by proximity means, hysteresis within the positioner is non-existent. This feature allows for extremely accurate tracking of the control signal to within 1/1 of 1 ma. A non-contact position sensor, employing Hall Effect magnetic principles for position feedback, is embedded within the ICoT housing. An external magnetic module, attached to the output shaft of the actuator rotates about the Hall Effect sensor. An analog-to-digital converter interfaces between the position sensor and a microprocessor while also transmitting the incoming position command (instrument signal) to the microprocessor. Servo circuitry is then utilized for implementation of position control. SENSOR LINEAR CONTROL The ICoT proximity positioner represents a significant departure from previous attempts to reliably measure valve stem position. A static slide-by actuation assembly, attached to the valve stem, is the only moving part of the positioner. Position sensing is performed totally by non-contacting means. Output updating takes place twenty times per second. A microprocessor implements any alteration required to provide the equivalent of equal percentage, quick opening, or linear valve characteristics. Output of the processor is the setpoint input for the servo amplifier circuitry, while the position sensor provides feedback. The position sensor output signal is also fed to the analog-to-digital converter permitting a wide range of diagnostic information to be generated. VALVE YOKE VALVE STEM TOP VIEW SENSOR

Remote Mount Capability REMOTE POSITION CONTROL The is the only positioner capable of remotely controlling a process valve from up to a distance of fifty feet. Since valve position feedback is accomplished by non-contacting means, the ICoT proximity positioner has the unique ability to be mounted remotely from the device it is controlling. For applications where a control valve is located in either a high vibration or extremely corrosive environment, the non-contact position feedback feature allows for isolated placement of the positioner. The position sensor output signal is also fed to the analog-to digital converter housed within the positioner, thereby permitting a wide range of diagnostic information to be generated. From this information, conditions relating to excessive valve friction and the like, may be delineated. HART information consisting of calibration data, current position, and various internal error conditions may be quickly retrieved due to the accessibility of the positioner.

14 14 14 Dimensional Data SERIES 4 - Engineered Resin Enclosure (Dim. inches/mm) Enclosure: Nema 4, 4X Terminal Block: 8 Point Standard Conduit Entrance: One 1/ NPT Standard 1-1/ & -3/4 NPT, Optional M or PG13.5 Optional 3. 76 1. / 5 1.73 44 3.31 84 OPEN 7.76 197 SIDE VIEW 1/4" NPT (3PLACES) 3.4 DIA. 86 DIA> 3.98 11 1.75 44 5/16-18 x 1/" M8 x 1.5 (4 PLACES) 4 6 8 4 6 1 8 1 11 1 16 4 6 8 4 6 1 8 1 11 1 16 4 6 8 4 6 5.93 15 TOP VIEW 1 8 1 11 1 16 3. 76 1.375 35 1/" NPT M (optional).15 65 4.31 19 BOTTOM VIEW 3/4" NPT ( PLACES) Westlock reserves the right to change product designs and specifications without notice, and is not responsible for errors and omissions. Ordering Guide MOUNTING O Normal Mtg. 5 Remote Mtg. ENCLOSURE E Engineered Resin CALIBRATION/COMMUNICATION P Potentiometer K Via On Board Keypad H Via Hart Communication B Both Hart & Keypad *Select option K for the 4 Series or H or B for the 43 Series SWITCHES O None 1 One SPST Two SPST ACTUATOR TYPE 1 Linear 3 Rotary 43 NIEHK A B F OUTPUT OPTION A No Transmitter B 4- ma Analog Output SERIES 41 41 Series 4 4 Series 43 43 Series GAIN F Full Range - Gain adjustment of the positioner can accommodate nearly all valve/actuator combinations. HAZARDOUS RATING NI Nonincendive IS Intrinsically Safe PRESSURE (Actuator Supply) H 4-1 PSI L 15-45 PSI V High Flow (4-1 psi) CONDUIT ENTRY A One 1/ NPT B One M C One PG13.5