ASCO SERIES 300 Service Entrance Power Transfer Switch

Similar documents
Series 300 POWER TRANSFER SWITCHES MAXIMUM RELIABILITY & EXCELLENT VALUE FEATURES

ASCO Series 300 Power Transfer Switches

ASCO Series 300 Power Transfer Switches

Maximum Reliability & Excellent Value. Features. UL Listed Withstand & Close-On Ratings. Series 300 Power Transfer Switches

4000 SERIES Power Transfer Switches Product Features

ASCO Series 300 Power Transfer Switches for Power Outage Protection

920 Remote Control (RC) Switches

ASCO SERIES 200 Power Transfer Switches

ASCO 4000 Series Power Transfer Switches

Power Switching & Controls for Business-Critical Continuity

ASCO SERIES 300 Manual Transfer Switch Solutions

ASCO 920 Remote Control (RC) Switches

ASCO Power Transfer Load Centers. Power Switching & Controls for Business-Critical Continuity

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

7000 SERIES Power Switching Solutions. Closed Transition Transfer Switching. Delayed Transition Transfer Switching

Model KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.

7000 SERIES Power Switching Solutions. Closed Transition Transfer Switching. Delayed Transition Transfer Switching

Model KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.

SUGGESTED SPECIFICATION For Series 300 Automatic Transfer Switches (3ATS)

GE Digital Energy Power Quality. Zenith ZTG Series. Low-Voltage Automatic Transfer Switches

Model: KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.

Transfer Switches 5.1 Transfer Switch Equipment Product Selection Guide... Product Description... Application Description...

ASCO Series 300 Generator Paralleling System

LOW VOLTAGE BYPASS/ISOLATION BREAKER BASED AUTOMATIC TRANSFER SWITCHES SECTION 16496D

ASCO 4000 Series Power Transfer Switches

Medium-Voltage Circuit Breaker-Type Automatic Transfer Switches and Bypass/Isolation Switches

SECTION 16496E ATS MOLDED CASE WITH ATC 900 CONTROLLER

ASCO 7000 Series POWER TRANSFER SWITCH

ASCO 4000 SERIES Series Power Transfer Switches Product Features Series

SECTION TRANSIENT VOLTAGE SUPPRESSION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS

ASCO 4000 SERIES Power Transfer Switches

SECTION SWITCHBOARDS

ASCO SERIES 230 Automatic Transfer Switch

Application Techniques CENTERLINE 2100 Motor Control Centers

Catalog Number Identification with Elements Explained V V V V X 347 V Hz

Transfer Switches Contactor-Based Designs

MX150 CONTROLLER. Operation & Maintenance Manual CI-AZOM E (12/12) (70R-2000D)

GE Zenith Controls. Operation and Maintenance Manual. MX150 Microprocessor Controller Transfer Switch Control Panel 70R-2000C 11/04

Series TS Amp. Automatic Transfer Switches

Transfer Switches Magnum-Based Designs

Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System

SUGGESTED SPECIFICATION CLOSED TRANSITION AUTOMATIC TRANSFER SWITCH WITH LOAD BREAK BYPASS/ISOLATION OPERATION WITH RPTCS MICROPROCESSOR CONTROL

CTG/CTGD Series Transfer Switches Amps CI-AZOM E (10/10) 70R-1000D. Operation and Maintenance Manual

(1986; Rev. 1989) Molded Case Circuit Breakers and Molded Case Switches. (1985; Rev. 1988) Enclosures for Electrical Equipment (1000 Volts Maximum)

Transfer Switches Magnum-Based Designs

SUGGESTED SPECIFICATION SINGLE OPERATOR OPEN TRANSITION AUTOMATIC TRANSFER SWITCH WITH RPTCS MICROPROCESSOR CONTROL

PDI Modular Compact Remote Power Panel

SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

1. Section Lightning Protection for lightning protection system. D. The installation shall be in conformance with NEC Article 285.

SmartOnline V 10kVA 7kW Online, Double-Conversion UPS, 6U Rack/Tower, Extended Run, Pre-installed SNMP port, RS232, 3 Phase in-single Phase out

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

B. System Design and Performance Requirements

SECTION SURGE PROTECTION DEVICES. A. Section includes Surge Protection Devices for low-voltage power, control, and communication equipment.

Jockey Pump Controllers

ASCO 7000 Series IEC Medium Voltage Power Transfer Switches

SECTION 16450: NON-AUTOMATIC TRANSFER SWITCH / QUICK CONNECT GENERATOR SWITCHBOARD <S> <OM>

SWITCHGEAR. XLM Switchgear

2.) Cabinet setup and preset data shall, as standard, be fully user programmable on a per cabinet or system wide basis.

Power Series Transfer Switch

Series Amp Pad Mount Quick Connect Input and Output Power Panels

DGC-2000 DIGITAL GENSET CONTROLLER

Jockey Pump Controllers

SECTION SURGE PROTECTIVE DEVICES

White Paper Surge Protective Devices in Automatic Transfer Switches

SmartOnline SV Series 40kVA Medium-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, 2 Battery Modules

Specifications, Installation, and Operating Instructions

Series 230 Automatic Transfer Switch

PowerFlex 400 AC Drive Guide Specification

SmartOnline SVX Series 120kVA Modular, Scalable 3-Phase, On-line Double-Conversion 400/230V 50/60Hz UPS System

The ASCO 7000 Series. Protecting data centers, hospitals, airports, retail stores and other facilities

SmartOnline SVX Series 90kVA 400/230V 50/60Hz Modular Scalable 3-Phase On-Line Double- Conversion Medium-Frame UPS System, 5 Battery Modules

SmartOnline 10kVA On-Line, Double-Conversion UPS, 6U Rack/Tower, 3-Phase input, 1-Phase output

SECTION DISTRIBUTION SWITCHBOARDS

SmartOnline SVTX Series 3-Phase 380/400/415V 30kVA 27kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

White Paper Avoiding SPD Procurement Errors

PGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY

Series 230 Automatic Transfer Switch

Power Series Transfer Switch

Experience, innovation and reliability

Total Protection Solutions Surge Protective Devices SurgeTrack Series: 080, 120, 160, 240, 300 and 400

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

Series 230 Automatic Transfer Switch

AIR COOLED MODULAR RECTIFIER

SmartOnline SV Series 20kVA Small-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, No SVBM Battery Module

Elastimold Molded Vacuum Recloser - MVR

ASCO 7000 Series Power Transfer Switches

4.3. Switchboards. Contents Description Pow-R-Line Drawout Molded Case Circuit Breaker Switchboards Product Selection...

You re in Total Command DISCOVER THE AWESOME POWER OF THE ASCO LOW VOLTAGE 7000 SERIES GENERATOR PARALLELING CONTROL SWITCHGEAR

DIVISION 16 SECTION Surge Protective Device Submittal (SPD)

soft load power transfer solutions for continuous, reliable power

ASCO 7000 SERIES Medium Voltage Tranfer Switches

MAXIOM. Data Sheet. Lighting Relay Panel. Overview Leverage the Power of BAS Integration

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

GE Zenith Controls. Operation and Maintenance Manual. Entelli-Switch 250 Microprocessor Controller Transfer Switch Control Panel 71R-2000A 11/04

SmartOnline V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack, LCD display, USB, DB9 Serial

THE SURGE PROTECTION SOLUTION

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

Quick Start Installation Guide

Line A. Inverse parallel scrs. Load a FUSION. Line B SCR POWER. O delta CONTROLLERS. Line c. inverse parallel scrs. Load C. FUSION Brochure Rev 3.

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

Transcription:

ASCO SERIES 300 Service Entrance Power Transfer Switch The ASCO Service Entrance Power Transfer Switch combines automatic power switching with the necessary disconnecting, grounding, and bonding required for use as service entrance equipment. The power transfer switch meets all National Electrical Code requirements for service entrance use. Product Features: Suitable for use as service entrance equipment. Sizes available from 70 3000 amps, 600 VAC, 50 or 60 Hz, single or three phase. 70 400 Ampere listed to UL 1008. 600 3000 Ampere listed to UL 891. Automatic Transfer Switch is listed to UL 1008 for total system loads. Silver plated copper ground and neutral bus with solderless screw type terminals. Ground fault trip protection provided on sizes 1000 amps and above. Available with solid or switched neutral. ASCO Series 300 SE Rated 800 amperes Type 1 enclosure ASCO Series 300 SE Rated amperes in Type 3R enclosure ASCO Series 300SE products use two types of construction. 70 400 Amp Construction 600 3000 Amp Construction Products 400 amperes or less, utilize a single enclosure including a service (utility source) disconnect circuit breaker, as well as the power transfer switch, grounding and bonding provisions. Products 600 amperes and above, utilize a multisection switchboard construction including a service equipment section containing the service (utility source) disconnect circuit breaker, grounding, and bonding provisions. A second section contains the power transfer switch.

J 03AUS B 3 0600 N GX C Frame Product Type Neutral Code Phase Poles Amperes Voltage Continous Rating Code Controller Code Enclosure D = 70 225 Amp 03AUS = Automatic A = Solid Neutral 2 0070, 0100, 0150, 0, A 1 = 115 B 1 = 120 G = No Optional Accessories C = Type 1 (Standard) M = Type 3R Secure Double J = 150 600 7 Amp 03NUS = NonAutomatic 3 0225 4 C = 208, GX = Optional Accessories Door B = Switched 0250 4 D = 220, N = Type 4 2 Secure Double E = 230 0400, 0600, Door H = 800 1 Amp 3ADUS = Automatic Delayed Neutral F = 240 0800, 1000, H = 380 P = Type 4X 5, 8 Secure Transition 1, 1600, J = 400 Double Door 304 SS G = 1600 3000 Amp 0 K = 415 Q = Type 12 2 Secure Double 3NDUS = NonAutomatic, 2500, 3000 L = 440 Door Delayed Transition M = 460 N = 480 R = Type 3RX 5, 6 Secure Double Door 316 SS P = 550 S = Type 3RX 5, 6 Secure Q = 575 Double Door 304 SS R = 600 V = Type 4X 5, 8 Secure Double Door 316 SS Notes: 1. 115120 volt available 150400 amperes for 3AUS, 3NUS only. 2. Available for 701600 amperes, use type 3R for 03000 ampere applications. 3. A solid neutral is provided as standard. 4., 225 ampere rated switches suitable for use with copper cable only. Refer to paragraph 310.15 of the NEC for additional information. ASCO Series 300SE Power Transfer Switch Dimensions and Shipping Weights UL Type 1 Enclosure 4 UL Type 3R Enclosure 4 Switch Rating Amps 70, 100, 150,, 225 150,, 225, Series 3ADUS/3NDUS Only 250 1, 400 1 600 1 800 1 1000 1, 1 1 Phase Poles Neutral Code Dimensions, In. (mm) Width Height Depth Series 300SE External Power Connections Sizes ULListed Solderless ScrewType Terminals Switch Rating Ranges of ALCU Wire Sizes Approx. Shipping Weight Lb. (kg) 2 A 36 (914) 48 (1219) 13 (330) 400 (185) 2 B 36 (914) 48 (1219) 13 (330) 410 (189) 3 A 36 (914) 48 (1219) 13 (330) 410 (189) 3 B 36 (914) 48 (1219) 13 (330) 430 (198) 2 A 36 (914) 48 (1219) 13 (330) 400 (185) 2 B 36 (914) 48 (1219) 13 (330) 408 (188) 3 A 36 (914) 48 (1219) 13 (330) 408 (188) 3 B 36 (914) 48 (1219) 13 (330) 420 (193) 2 A 42 (1067) 48 (1219) 15.5 (394) 420 (193) 2 B 42 (1067) 48 (1219) 15.5 (394) 430 (198) 3 A 42 (1067) 48 (1219) 15.5 (394) 430 (198) 3 B 42 (1067) 48 (1219) 15.5 (394) 450 (207) 2 A 38 (965) 91 (2311) 28 (711) 860 (396) 2 B 38 (965) 91 (2311) 28 (711) 870 (401) 3 A 38 (965) 91 (2311) 28 (711) 870 (401) 3 B 38 (965) 91 (2311) 28 (711) 880 (405) 2 A 38 (965) 91 (2311) 28 (711) 1460 (673) 2 B 38 (965) 91 (2311) 28 (711) 1470 (677) 3 A 38 (965) 91 (2311) 28 (711) 1470 (677) 3 B 38 (965) 91 (2311) 28 (711) 1480 (682) 2 A 38 (965) 91 (2311) 48 (1218) 1460 (673) 2 B 38 (965) 91 (2311) 48 (1218) 1470 (677) 3 A 38 (965) 91 (2311) 48 (1218) 1470 (677) 3 B 38 (965) 91 (2311) 48 (1218) 1480 (682) 3 A 38 (965) 91 (2311) 48 (1218) 1580 (727) 1600 1, 0 1 3 B 38 (965) 91 (2311) 48 (1218) 1680 (773) 3 A 38 (965) 91 (2311) 72 (1829) 4590 (2111) 2500 1, 3000 1 3 B 38 (965) 91 (2311) 72 (1829) 4690 (2157) Notes: 1. Unit is designed for top and bottom cable entry for all services and load. 2. Enclosures for 600 3000 amps are freestanding. 3. A space heater accessory 44G is required with all service entrance (Type 3R) switches to help reduce 70, 100, 150, 2, 225 2 One #14 to 4/0 AWG 150 3, 3, 225 3, One #4 AWG to 600 MCM 250, 400 Two 1/0 to 250 MCM 600 Two 1/0 to 600 MCM 800, 1000, 1 Four 1/0 to 600 MCM 1600, 0 Six 1/0 to 600 MCM 2500 Twelve 3/0 to 750 MCM 3000 Twelve 3/0 to 750 MCM Notes: 1. All Series 300SE switches are furnished with a solid neutral plate (unless switched neutral configuration is specified) and terminal lugs. 2. and 225 ampere rated switches for use with copper cable only. Refer to paragraph 310.15 of the NEC for all additional information. 3. J 150225 ampere for Series 3ADUS/3NDUS only. 4. Use wire rated 75 degrees minimum for all power connections. 5. Refer to the outline drawing for maximum power cable connections for circuit breaker. 5. Type 316 stainless steel is the standard. It provides an improved reduction in corrosion of salt and some chemicals. It is the preferred choice for marine environments. 6. Available only on switches rated 1600, 0, 2600 and 3000 amperes. 7. J 150225 ampere for Series 3ADUS/3NDUS only. 8. Available only on switches rated 70 1600 amperes. Switch Rating Amps 70, 100, 150,, 225 150,, 225, Series 3ADUS/3NDUS Only 250 1, 400 1 600 1 800 1 1000 1, 1 1 Phase Poles Neutral Code Dimensions, In. (mm) Width Height Depth Approx. Shipping Weight Lb. (kg) 2 A 36 (914) 48 (1219) 16 (406) 500 (232) 2 B 36 (914) 48 (1219) 16 (406) 520 (241) 3 A 36 (914) 48 (1219) 16 (406) 520 (241) 3 B 36 (914) 48 (1219) 16 (406) 530 (246) 2 A 41 (1041) 95.5 (2424) 33 (838) 500 (232) 2 B 41 (1041) 95.5 (2424) 33 (838) 520 (241) 3 A 41 (1041) 95.5 (2424) 33 (838) 520 (241) 3 B 41 (1041) 95.5 (2424) 33 (838) 530 (246) 2 A 42 (1067) 48 (1219) 15.5 (394) 500 (232) 2 B 42 (1067) 48 (1219) 15.5 (394) 520 (241) 3 A 42 (1067) 48 (1219) 15.5 (394) 520 (241) 3 B 42 (1067) 48 (1219) 15.5 (394) 530 (246) 2 A 38 (965) 91 (2311) 28 (711) 1 (555) 2 B 38 (965) 91 (2311) 28 (711) 1220 (564) 3 A 38 (965) 91 (2311) 28 (711) 1220 (564) 3 B 38 (965) 91 (2311) 28 (711) 1240 (574) 2 A 38 (965) 91 (2311) 28 (711) 1520 (703) 2 B 38 (965) 91 (2311) 28 (711) 1540 (712) 3 A 38 (965) 91 (2311) 28 (711) 1540 (712) 3 B 38 (965) 91 (2311) 28 (711) 1580 (731) 2 A 38 (965) 91 (2311) 48 (1218) 1520 (703) 2 B 38 (965) 91 (2311) 48 (1218) 1540 (712) 3 A 38 (965) 91 (2311) 48 (1218) 1540 (712) 3 B 38 (965) 91 (2311) 48 (1218) 1580 (731) 3 A 38 (965) 91 (2311) 48 (1218) 2 (1018) 1600 1, 0 1 3 B 38 (965) 91 (2311) 48 (1218) 2240 (1036) 3 A 38 (965) 91 (2311) 72 (1829) 5280 (2479) 2500 1, 3000 1 3 B 38 (965) 91 (2311) 72 (1829) 5380 (2475) condensation and protect the circuit breaker. It is recommended when environmental enclosures (Type 4, 12) are ordered for installation outdoors. See Optional Accessories page for space heater options (acc. 44G). 4. Dimensional data is approximate and subject to change. Certified dimensions available upon request. Extended Warranties for Series 300SE Transfer Switches (3AUS/3NUS/3ADUS/3NDUS) Description 1 Year Extension (Total of 3 Years) 2 Year Extension (Total of 4 Years) 3 Year Extension (Total of 5 Years) Notes: 1. Standard warranty is (24) months, 2 years from date of shipment, extended warranty is in addition to the two years, for a total of 3, 4 or 5 years, except where the warranty period for the circuit breaker shall be limited to 24 months from date of shipment from ASCO. 2. Refer to Publication 3223 for warranty terms and conditions. Series 300SE AIC Breaker Rating 1 Switch Rating AIC Rating (KA) Voltage 70, 100, 150,, 225 25,000 480 150,, 225 Series 3ADUS/3NDUS Only 35,000 480 250, 400, 600 35,000 480 800 65,000 480 1000, 1 50,000 480 1600, 0 65,000 480 2500, 3000 100,000 480 ASCO Power Technologies 160 Park Avenue, Florham Park, NJ 07932 Notes: 1. Refer to Series 300 Publication 1195 for switch ratings. www.ascopower.com customercare@ascopower.com 1800800ASCO (2726) Copyright January 2017. Publication 7 R2

ASCO UL1008 Withstand and Closing Ratings 1,2,7 (RMS Symmetrical Amps) 300, 4000 & 7000 Series 4000 & 7000 Series 7000 Series Switch Rating (Amps) Current Limiting Fuses Specific Breaker Time Based Short Time Ratings 3 (sec) Frame 480V Max. 600V Max. Transfer Bypass Switches 480V 600V Max Size, 240V 480V 600V Time 240V 480V 600V Switches Class.13.2.3.5.1.13.3.5 Max. Max. A Max. Max. Max. (sec) Max. Max. Max. 100kA 300 J D 30 ka J 22kA 22kA 0.025 RK1 D D 70, 100 150 RK1 RK1 ka ka J J 42kA 25kA 25kA 0.025 0.025 D ka J 25kA 0.025 D 230 100kA 300 J 25kA 0.025 E 260, 400 ka 600 J 42kA 0.05 22kA J 150,, 260, 150,, 230, 600 J ka ka 400 260, 400 800 L 50kA 50kA 42kA 0.05 42kA 5 7.5kA J 600 600 ka ka 800 L ka ka 600 J 50kA 50kA 42kA 0.05 42kA 5 7.5kA 9 H 8 600 600 ka ka 1600 L 0.05 50kA 50kA 50kA 36kA 36kA P 8 600 600 ka ka 1600 L 0.05 50kA 50kA 50kA 36kA 30kA 36kA P 8 800 800 1 ka ka 1600 L 0.05 50kA 50kA 50kA 36kA 30kA 36kA H 800 1 800 1 ka ka 1600 10 L 0.05 50kA 50kA 50kA 36kA 36kA Q 8 6001600 6001600 ka ka 0 L 0.05 50kA 50kA S 8 800 1 800 1 ka ka 2500 L 100kA 100kA 0.05 100kA 100kA G 8 1000 1 1000 1 ka ka 0 L 85kA 85kA 85kA 0.05 85kA 85kA 85kA G 1600 0 4 ka ka 2500 L 85kA 4 85kA 4 85kA 4 0.05 85kA 4 85kA 4 85kA 4 42kA 36kA G 8 1600 0 1600 0 ka ka 3000 L 125kA 6 125kA 6 100kA 0.05 100kA 100kA 100kA 42kA 36kA 42kA S 8 1600 0 1600 0 ka ka 2500 L 100kA 100kA 85kA 0.05 100kA 100kA 85kA 85kA 85kA G 2600 3000 2600 3000 ka ka 4000 L 100kA 100kA 100kA 0.05 100kA 100kA 100kA 42kA 36kA 42kA G 8 3 ka 4000 L 100kA 100kA 0.05 100kA 100kA G 4000 4000 ka ka 5000 L 100kA 100kA 100kA 0.05 100kA 100kA 100kA 85KA U 8 2600 4000 2600 4000 ka ka 5000 L 125kA 125kA 125kA 0.05 125kA 125kA 125kA 100kA 100kA Notes: 1) All WCR values indicated are tested in accordance with the requirements of UL 1008, 7th Edition. See ASCO Pub. 1128 for more WCR information 2) Application requirements may permit higher WCR for certain switch sizes. 3) Short Time ratings are provided for applications involving circuit breakers that utilize trip delay settings for system selective coordination 4) Optional front connected service (Accy 40MY and 40NY) limits WCR on 1600 and 0A G Frame switches 5) Switches utilizing overlapping neutral (code "C") have, 0.050 Sec time based rating at 480V Max 6) Rating shown is for Bypass switches only, Transfer Switch rating is 100kA 7) See ASCO for Service Entrance Switch ratings 8) These frames are only available on the 7000 Series product 9) Short Time Rating applies to 600A Bypass switch only, the 600A Transfer Switch does not have a Short Time Rating 10) Max fuse rating is 1A on front connected H frame switches 3Mar17

Series 300 NEW MICROPROCESSOR CONTROLLER The Series 300 incorporates the group G controller with enhanced capabilities for dependable operation in any environment. TIME DELAYS Controller/TS Interface Plug Battery to Maintain Engine Exerciser Clock Settings 2) SE and ER Relay Control Power Transformers Power Supply Jumper Card Engine start time delay delays engine starting signal to override momentary normal source outages, adjustable from 0 to 6 seconds (Feature 1C). Emergency source stabilization time delay to ignore momentary transients during initial generator set loading, adjustable from 0 to 4 seconds (Feature 1F). Retransfer to normal time delay with two settings (Feature 3A). Power failure mode 0 to 60 minutes Test mode 0 to 10 hours Unloaded running time delay for engine cooldown, adjustable from 0 to 60 minutes (Feature 2E). Pre and postsignal time delay for selective load disconnect with a programmable bypass on source failures, adjustable from 0 to 5 minutes (specify ASCO optional accessory 31Z). Optional fully programmable engine exerciser with seven independent routines to exercise the engine generator, with or without loads, on a daily, weekly, biweekly or monthly basis (specify ASCO optional accessory feature bundle 11BE). Delayed transition load disconnect time delay, adjusable from 0 to 5 minutes (3ADTS/3NDTS configuration only). STANDARD SELECTABLE FEATURES Dip Switches for Voltage/Frequency and Feature Functions Mounting Location for Accessory Dongle NR Relay Customer Control Interface Fig. 8: ASCO Series 300 Microprocessor Controller CONTROL AND DISPLAY PANEL RS 485 Port (Optional) Enabled with Feature Bundle 11BE 485 Configuration Dip Switches Mounting Location for Current Sensing Card CAN Bus Port Easytonavigate 128x64 graphical LCD display with keypad provides LED indicators for switch position, source availability, not in auto mode, and alert condition. It also includes test and time delay bypass soft keys. VOLTAGE, FREQUENCY & CURRENT SENSING 3phase under and over voltage settings on normal and single phase sensing on emergency source. Under and over frequency settings on normal and emergency. True RMS voltage sensing with +/1% accuracy. Frequency sensing accuracy is +/ 0.1Hz. Voltage and frequency parameters adjustable in 1% increments. Selecting settings: single or three phase voltage sensing on normal, and single phase sensing on emergency; 50 or 60Hz. 3phase voltage unbalance on normal. Load current sensing card (optional). Inphase monitor to transfer motor loads, without any intentional off time, to prevent inrush currents from exceeding normal starting levels. Engine exerciser to automatically test backup generator each week, with or without load 20 minutes not adjustable. Commit to transfer. Selective load disconnect circuit to provide a pretransfer and/or posttransfer signal when transferring from emergency to normal and/or normal to emergency. Retransfer to normal through soft keys on user interface permits selection of manual or automatic operation. 60Hz or 50Hz selectable switch. Three/single phase selectable switch. REMOTE CONTROL FEATURES External inputs for connecting: Remote test switch. Remote contact for test or peak shaving applications. If emergency source fails, switch will automatically transfer back to normal source if acceptable. Inhibit transfer to emergency. Remote time delay bypass switch emergency to normal.

Series 300 GROUP G OFFERS SOPHISTICATED FUNCTIONALITY The new Group G controller offers an intuitive, easytonavigate 128*64 graphical LCD display with soft keypad and provides six (6) LED indicators. Switch Position (green for normal, red for emergency LED) S.ource Availability (green for normal, red for emergency LED) Not In Auto (amber LED) Common Alarm (amber LED) The ASCO group G controller is selfcontained with an integrated display (no other components are required for efficient operation). The controller allows for open or delayed transition transfer opertion (both automatic, and nonautomatic configurations). An integrated multilingual user interface for configuration and monitoring (this design approach allowsgreater application flexibility). Multiple sourcesensing capabilities of voltage, frequency (under frequency sensing on normal and emergency sources), and optional current card, single and three phase (does not require an external metering device). Fig. 9: DoorMounted Control & Display Panel 1 2 4 3 6 5 1 Common Alarm 2 Not In Auto Indicator 3 Scroll, Up/Down Arrows 4 Escape Key 5 Enter Key 6 LED Source Availability and Switch Position Indicators Transfer / Time Delay Override control pushbutton Control Status Source Status Alarm Status Controller Information Settings Settings/ Engine Exerciser Settings/General/ Communications Settings/General/Common Alarms Event Logging Statistics Factory/Diagnostics About

Series 300 ATS OPTIONAL ACCESSORIES ACCESSORY 1UP UPS back up power to allow controller to run with LCD display for 30 seconds without AC power. ACCESSORY 11BE FEATURE BUNDLE A fully programmable engine exerciser with seven independent routines to exercise the engine generator with or without loads, on a daily, weekly, biweekly or monthly basis. Engine exerciser setting can be displayed and changed from the user interface keypad. Event Log display shows the event number, time and date of event, event type, and event reason (if applicable). A maximum of 300 events can be stored. RS 485 Communications Port Enabled Common Alarm Output Contact ACCESSORY 18RX Relay expansion module (REX) provides for some commonly used accessory relays, includes one form C contact for source availability of normal (18G), and one form C contact for availability of emergency (18B) (contact rating 5 amperes @ 30Vdc or @125 VAC resistive). Additional output relay is provided, the default is to indicate a common alarm. (See operator s manual for configurable options.) ACCESSORY 23GA 1 (SINGLE PHASE) AND 23GB (THREE PHASE) Load current metering card measures either single or three phase load current. Note 1: This feature is not available with a Power Meter Option (135L). ACCESSORY 44A Strip Heater with thermostat for extremely cold areas to prevent condensation and freezing of this condensation. External 120 volt power source required. ACCESSORY 44G Strip Heater with thermostat, wired to load terminals: 208240, 360380, 460480, 550600 volts. Contains wiring harnesses for all transfer switch sizes. ACCESSORY 72EE Connectivity Module enabling remote monitoring and control capabilities (pages 1214) ACCESSORY 73 Surge Suppressor (TVSS) Rated. ACCESSORY 62W Audible alarm with silencing feature to signal each time switch transfers to emergency (may require oversize enclosure depending on accessory combination for "D" frame only). ACCESSORY 37B 6' Extension harness for units shipped open type to accommodate customer mounting of controls and switch. ACCESSORY 37C 9' Extension harness for units shipped open type to accommodate customer mounting of controls and switch. ACCESSORY 135L 2 Power Meter on load side (includes shorting block and CTs)Note 2: This feature is not available with Load Current Metering Option (23GA or 23GB). ACCESSORY 30A 3 Shedding circuit initiated by opening of a customersupplied contact. ACCESSORY* 3 Loadshedding circuit initiated by removal of customersupplied voltage. (*Specify Voltage) ACCESSORY 30AA 3 Loadshedding circuit initiated by opening of a customersupplied contact. ACCESSORY 30BA* 3 Loadshedding circuit initiated by removal of customersupplied voltage. (*Specify Voltage) Note 3: Accessory 30A and 30B* are only available for 3ATS only; accessory 30AA and 30BA* are only available for 3ADTS. FIELD CONVERSION KITS FOR Series 300 TRANSFER SWITCHES KIT NO. DESCRIPTION 935147 Feature Bundle Includes Engine Exerciser/Event Log/RS 485/Common Alarm Output Contact (Acc. 11BE) Dongle 935148 REX Module with Source Availability Contacts (Acc. 18RX) 935149 UPS to allow controller to run for 30 seconds minimum without AC Power (Acc. 1UP) 935150 1/3 Phase load current sensing card only (Acc. 23GA/GB) K613127001 Strip Heater (125 watt) 120 volt (Acc. 44A) K613127002 Strip Heater (125 watt) 208480 volt (Acc. 44G) Fig. 10: Strip Heater Kit (Accessory 44G) Fig. 12: Load Current Card (Accessory 23GA/GB) Fig. 11: Relay Expansion Module (Accessory 18RX) Fig. 13: Programmable Engine Exerciser 948551 QuadEthernet Module (Acc. 72EE) K609027 Cable Pull Box (16000 amperes) Fig. 14: Accessory 1UP UPS Backup Power