Series 230 Automatic Transfer Switch

Similar documents
Series 230 Automatic Transfer Switch

Series 230 Automatic Transfer Switch

ASCO SERIES 230 Automatic Transfer Switch

SERIES 230 Automatic Transfer Switch C1000 Intelligent Controller User Manual

Model KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.

Model KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.

Maximum Reliability & Excellent Value. Features. UL Listed Withstand & Close-On Ratings. Series 300 Power Transfer Switches

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

SERIES 230 A2ADTL Transfer Switch User Manual

ASCO 920 Remote Control (RC) Switches

920 Remote Control (RC) Switches

SERIES 230 C2ADTL Transfer Switch User Manual

SECTION 16496E ATS MOLDED CASE WITH ATC 900 CONTROLLER

Model: KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

MSR 2400R. Rugged Power System for Military and Heavy Duty Applications

4000 SERIES Power Transfer Switches Product Features

ASCO SERIES 300 Manual Transfer Switch Solutions

STANDARD SUBMITTAL PACKAGE

Series 300 POWER TRANSFER SWITCHES MAXIMUM RELIABILITY & EXCELLENT VALUE FEATURES

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)

TECHNICAL DESCRIPTION

White Paper Surge Protective Devices in Automatic Transfer Switches

MAXIOM. Data Sheet. Lighting Relay Panel. Overview Leverage the Power of BAS Integration

FTA750 LIMITED SERVICE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

ASCO SERIES 300 Service Entrance Power Transfer Switch

CI-tronic Reversing contactor Type RCI

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

RT4F-120V/20A-WAC RECTIFIER

ASCO Series 300 Generator Paralleling System

FTA1350 WYE-DELTA CLOSED FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

RT12-240V/2.4kW Rectifier Specification

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

Residual Current Devices FRCdM Type B, B+ and Bfq Digital

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.

Residual Current Devices. Residual Current Devices FRCmM-NA according to UL1053 & IEC/EN 61008

Residual overvoltage relay

Chloride CROSS Rack 16 A, 32 A and 63 A

Bulletin 290/291 ArmorStart LT Distributed Motor Controllers Specifications

MINER-S Station Controller

ATS22C21S6U softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp)

RT4F-110V/25A RECTIFIER

Contact protection relay

RT4F-48V/50A-WAC RECTIFIER

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

Uninterruptible Power Supplies

ASCO Power Transfer Load Centers. Power Switching & Controls for Business-Critical Continuity

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description

LOW VOLTAGE BYPASS/ISOLATION BREAKER BASED AUTOMATIC TRANSFER SWITCHES SECTION 16496D

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1

SUGGESTED SPECIFICATION SINGLE OPERATOR OPEN TRANSITION AUTOMATIC TRANSFER SWITCH WITH RPTCS MICROPROCESSOR CONTROL

GE Digital Energy Power Quality. Zenith ZTG Series. Low-Voltage Automatic Transfer Switches

BT300 HVAC Drives Electronic Bypass (E-Bypass) Options

RT4B-110V/12A RECTIFIER

ATS22C17Q. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)

ASCO 7000 SERIES Power Control Systems

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Overvoltage Protection Devices

ADJUSTABLE SPEED DRIVES. Q9 Series

AI561 Analog Input Module

Liebert LM Series Surge Protective Device Continuous Protection For Your Business. Surge Protection For Business-Critical Continuity

DC561, digital input/output module,

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

DI561 Digital Input Module

Dorman Smith Loadbank 125 MCCB Panel Boards

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

JK Series POWER DISTRIBUTION. Solid State Starters Medium Voltage A

Bulletin 294 ArmorStart LT Distributed Motor Controllers Feature Diagram

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100hp)

Redundancy unit CP-A RU

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing

ATS22D47S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATS01N206RT soft starter for asynchronous motor - ATS01-6 A V

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

ATS22C41Q soft starter-ats22-control 220V-power 230V(110kW)/ V(220kW)

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka

DX561 Digital Input/Output Module

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

AO523 Analog Input Module

RT7-48V/6kW Specification

DC562, digital input/output module,

BT300 HVAC Drives. Designed for HVAC. Description. Technical Specification Sheet Document No March 4, 2013

SmartOnline 208/120V or 240/120V 16kVA 11.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 8U Rack/Tower, USB, DB9 Serial

895/896M Frequency Output Math Modules

DI572 Digital Input Module

Siemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities.

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

T300MVi MEDIUM VOLTAGE DRIVES

Transfer Switches 5.1 Transfer Switch Equipment Product Selection Guide... Product Description... Application Description...

TU531, TU532 Terminal Unit

TF501, TF521 Terminal Bases

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS

Cashpower Three Phas e

Transcription:

Series 230 Automatic Transfer Switch

Global Headquarters-Florham Park, New Jersey ASCO was founded in 1888, and manufactured the first ATS in 1920, ASCO focuses on the development of ATS, and has become the leader in the ATS industry. The picture on above is ASCO s headquarters, located in Florham Park, New Jersey. ASCO has more than 1600 employees and more than 4 factories covering over 500,000 square feets of manufacturing floor space in North America and Asia. ASCO has installed more than 500,000 automatic transfer switches worldwide. No other manufacturer comes close. The more you know, the more confidence you have in choosing ASCO provides diversified products and solutions to match different requirements: Automatic Transfer Switch ATS Closed Transition Transfer Switch CTTS Delayed Transition Transfer Switch DTTS Automatic Transfer Bypass-Isolation Switch ATB Automatic Closed Transition Bypass- Isolation Switch ACTB Static Transfer Switch STS Soft Load Transfer Switch SLTS Medium Voltage Automatic Transfer Switch MVATS Medium Voltage Closed Transition Transfer Switch MVCTTS Three Position Automatic Transfer Switch Center-off Multi-Sources Transfer System Multi-Generator Parallel Power Connection Systems Emergency Power Management System Lighting Control Contactors Surge Protection Device Standards GB14048.11 IEC/EN 60947-6-1 UL1008 NFPA20,70,99,110 IEEE241.446 NEMA ICS101993 1

The Recognized Leader in Power Transfer Switch Technology Offers the Most Advanced Transfer Switches in the World. Product Overview The Series 230 automatic transfer switch consists of an intelligent controller and a modular load break switch which automatically transfers the load to the emergency power source when it detects under/over voltage, under/over frequency, or phase failure. The switch has three operation positions (source one - center off - source two). The two sources can be isolated in the center off position. A position locking mechanism is also provided. Application The Series 230 capacity is up to 400A, available from 220 to 415 volts, 50 and 60Hz, single phase and three phase. Typical applications include office buildings, residential buildings, telecom, hospital, subway, data center, military, transportation, and fire pump applications. Parameter Rated Operational Current Ie (A) 32 40 50 63 80 100 125 160 200 225 250 315 500 400 630 800 Rated Insulation Voltage U i (V) 800 800 800 800 Rated Impulse Withstand Voltage U imp (kv) 8 12 12 12 Rated Operation Voltage U e (V) 220, 230, 240, 380, 400, 415 Rated Frequency (Hz) 50 / 60 Poles 2, 3, 4 Rated Short-Time Withstand Current I cw (ka, RMS) 10 (0.1s) 15 (0.1s) 25 (0.1s) 40KA(0.1s)/ 20KA(1s) Rated Short-Circuit Making Capacity I cm (ka, PEAK) 17 31.5 65 80 Withstand and Close-On Rating I q (ka) When Used With Current Limiting Fuses When Used With Specific Circuit Breakers Making and Breaking Capacity 10 I e Mechanical Operation Performance (cycles) 10,000 Utilization Category AC - 33B Ue=208V (0.75 1.2)Ue Operation Voltage range (AC) EMC Class Wiring Way Separate Lock Mechanism Auxiliary Contact Ue=220V / 230V / 240V / 380V / 400V Ue= 415V 65 200 200 200 (0.7 1.2) Ue (0.7 1.15) Ue Class A Front Standard Optional (8 contacts maximum) 150 150 80 2

Series 230 Automatic Transfer Switch Product Features Performance feature Meets or exceeds the requirements of the following regulatory agencies EN60947-6-1/IEC60947-6-1: transfer switching EN55022: Radiated and Conducted Emission, Class A EN61000-3-2: Harmonic Current Emission, Class A EN61000-3-3: Limits of Voltage fluctuation and Flicker EN 61000-4-5: Immunity to Surge EN 61000-4-4: Immunity to Electrical Fast Transient: EN61000-4-2: Immunity to Electrostatic Discharge EN61000-4-3: Immunity to Radiated Electric Fields EN 61000-4-6: Immunity to Continuous Conducted Interference Structure PC Class ATS High ability of withstanding lightning strikes (40kA 8/20μs) Simple reliable mechanism, compact and stylish appearance Modular design, convenient operation, easy maintenance Three operation positions. Two sources can be isolated in the center-off position Arc Extinguish The utilization category is AC-33B, and the ability of withstand and break is10 I e Rotating dual contacts design extinguishes the arc quickly and effectively Arcing contacts and main contacts are separate, avoids main contacts from being destroyed by an arc Clamping contacts are self cleaning wiping action type High short-circuit closing ability Switching Mechanism Both automatic and manual operation are available Unique contacts design limits contact bounce Unique clutch technique makes manual operation easy to do Electrical and mechanical interlocks prevent two sources from connecting simultaneously Innovative motor circuit protection technique, provides precision control Cast steel bevel gear mechanism provides high transmission efficiency, and extends the operation life Controller Different Operating Modes (Source I priority/ No Source priority) C2000 has ability to work with external 24VDC power supply High frequency switching power supply, and wide power voltage range Controller remains operational when power is lost, and avoids data loss Diagnosis fault intelligent with self - protection function (Motor-Protection) RS485 communication interface is available 3

Make Life and Business More Reliable By Using ASCO Series 230 Transfer Switch Ordering Information Type sample: Switch category B2ADTL B3 250 H E 0 0 Line and Neutral AC Voltage (V) 1 2 3 4 5 6 7 Poles L1 L2 L3 N L-L L-N B1 D M - 220 L1 L1 N N B1 E - 230 Source I Source II B1 F - 240 2P 02 C 208 M 02 D L1 L1 220 - L2 L2 02 E 230 - Source I Source II 02 F 240 - M B2 D 220 110 L1 L1 L2 L2 B2 E N N 230 115 Source I Source II B2 F 240 120 03 C 3P 208 - M 03 D L1 L1 220 - L2 L2 03 H L3 L3 380-03 J Source I Source II 400-03 K 415 - B3 C M 208 - L1 L1 B3 D 220 - L2 L2 L3 L3 B3 H 4P 380 220 N N B3 J Source I Source II 400 230 B3 K 415 240 B2ADTL B2ADTL Frame 32A-160A 1 Frame C2ADTL C2ADTL Frame 200A-250A D2ADTL D2ADTL Frame 315A-400A 0032 32A 0100 100A 0250 250A 0630 630A 0040 40A 0125 125A 0315 315A 0800 800A 3 Amps 0050 50A 0160 160A 0315 315A 0063 63A 0200 200A 0400 400A 0080 80A 0225 225A 0500 500A D C1000 Controller 5 Controller E C2000 Controller 6 Optional Accessories 0 Without Accessories X B2ADTL Frame Bridging Bus Bar: 132JA 132JC, Auxiliary Contacts: 132A 132F 1H, 72D See Page 5 7 Enclosure 0 Without Enclosure 4

Optional Accessory Model Description and Order Information B2ADTL Frame Bridging Bus Bar 132 J A Poles A: 2 poles B: 3 poles C: 4 poles Function Code 132J: Bridging Busbar 4 poles Bridging Busbar For example: 132JC, means Bridging Busbar for a 4 poles transfer switch Auxiliary Contacts 132 A A Auxiliary Contact Quantity BLANK: 1 contact A: 2 contacts B: 3 contacts C: 4 contacts Function Code 132A-132F: Auxiliary Contact Auxiliary Contact For example: 132BA, means 2 sets of contacts, closed when the ATS transfer to source II position. 5

The Auxiliary Contact Definition 132A-132C : The auxiliary contacts can be used to indicate positions with the CLOSE contact, see Schematic 1. 132D-132F: The auxiliary contacts can be used to indicate positions with the OPEN contact,see Schematic 2. Position of The Transfer Switch Auxiliary Contact Function Code 132A 132B 132C Position of The Transfer Switch Auxiliary Contact Function Code 132D 132E 132F I I O O II II Auxiliary Contact Code LAP1F100 - LAP1F010 - - Auxiliary Contact Code LAP1F100 - - LAP1F010 - Auxiliary Contact Mounting Position Auxiliary Contact Mounting Position 72D C1000 Controller with RS-485 interface A RS485 interface installed in the C1000 controller to enable serial communications. Supporting MODBUS protocol. The Accessory can be installed in the factory only. If you want this function, please tell us when you order the controller. 1H C2000 Controller with energy storage The optional controller with energy storage (Accessory 1H) has the added feature to switch the transfer switch to center-off position during Source I and Source II failure at the same time. This optional feature can work in Source I Priority and No Source Priority operating modes. And this feature is available only after the controller has been powered by AC input for 10 minutes. The Accessory can be installed in the factory only. If you want this function, please tell us when you order the controller. 6

Avoid Losing Critical information When Power is Lost B2ADTL Frame Series 230 Dimensions and Weight 78 104 117 184 126 221 A (unit: mm) B2ADTL 2P 3P 4P Size (mm) A 241.0 349.0 349.0 Weight (kg) 2.6 2.8 2.8 Note: It must be installed in DIN35 Rail to the cabinet C2ADTL Frame 167.8 Ø6 177.3 20 9 12.5 181.6 100 116 126 130 150.5 171.5 9 6 17 34 34 34 C 23 23 B A (unit: mm) C2ADTL 2P 3P 4P A 251.0 285.0 319.0 Size (mm) B 236.0 270.0 304.0 C 68.0 102.0 136.0 Weight (kg) 4.6 5.2 5.8 7

D2ADTL Frame 172.8 A B C 44 44 44 215 198.5 140120 120 157.8 186.3 Ø7 15.5x10.5 (unit: mm) D2ADTL 2P 3P 4P A 317.0 361.0 405.0 Size (mm) B 297.0 341.0 385.0 C 103.0 147.0 191.0 Weight (kg) 8.6 9.8 11.0 8

E2ADTL Frame 28 213 65 65 65 9 19 13 251.5 240 107 226 265 208 174 195 290 Ø9 60 10 8 B A C (unit: mm) E2ADTL 2P 3P 4P A 384 449 514 Size (mm) B 357 422 487 C 146 211 276 Weight (kg) 14 17 20 Shipping Dimensions and WeightsShipping Dimension and Weights (Including TS and controller, without options) Frame Width (MM) Height (MM) Depth (MM) Weight (KG) with C1000 Weight (KG) with C2000 2P 3P 4P 2P 3P 4P B2ADTL 602 220 267 4.9 5.5 5.7 5.2 5.8 6.0 C2ADTL 602 335 227 8.9 9.5 10.1 9.2 9.8 10.4 D2ADTL 650 350 300 13.0 14.5 16.0 13.4 14.9 16.4 E2ADTL 767 350 352 16 19 22 16.5 19.5 22.5 * All information is subject to change, for the latest information please contact ASCO sales team. 9

ASCO Power Transfer Switch Solutions for Powerful Peace of Mind Series 230 Controller Feature Comparisons C1000 Controller Voltage and Frequency Sensing 3-Phase under and over voltage settings on source I and source II Phase lose sensing on source I and source II Under and over frequency settings on source I and source II Time Delays Time delay sensing accuracy is ±1% Transfer time delay can be set manually Controller Display and Keypad LED display Touch pad for clearing alarm and manual operation Switch position indicator lights Source acceptability indicator lights Operating Modes Automatic and manual operation available Source I Priority/ No Source Priority Center-off with time delay and center-off with protection The center-off time delay can be set to avoid large current rushes to inductive loads Center-off with protection is available to protect critical loads (e.g. Fire Pump) Remote Control and Communication Can control switch remotely (e.g. Position Control, Time Delay, etc.) Fire control signal input (24VDC) Power Supply of Controller Operation Voltage (VAC): 220/ 230/ 240/ 380/ 400/ 415 C2000 Controller Voltage and Frequency Sensing 3-Phase under and over voltage settings on source I and source II Under and over frequency settings on source I and source II Voltage unbalance detection between phases Time Delays Time delay can be set by operating parameter setting menu Time delay sensing accuracy is ±1% Time delay can be set under different working modes Transfer time delay can be set manually Controller Display and Keypad LCD display Touch pad for programming the features and settings Switch position indicator lights Source acceptability indicator lights Operating Modes Automatic and manual operation available Source I Priority/ No Source Priority Center-off with time delay and center-off with protection The center-off time delay can be set to avoid large current rushes to inductive loads Center-off with protection is available to protect critical loads (e.g. Fire Pump) Events Display Event log displays: 100 logged events with time and date of each event, event type and event reason Remote Control and Communication Uses RS485 interface, and supports MODBUS Communication Can control switch remotely (e.g. Position Control, Time Delay, etc.) Fire control signal input (24VDC) Power Supply of Controller Operation Voltage (VAC): 220/ 230/ 240/ 380/ 400/ 415 C2000 has ability to work with 24VDC power supply 10

24-hours Protection No Matter When Trouble Strikes Controller C1000 C2000 Intended Application Residential, Light Commercial Commercial, Industrial Rated Operation Voltage U e (V) 220/230/240/380/400/415 220/230/240/380/400/415 Rated Frequency (Hz) 50/60Hz 50/60Hz Display Indicator Source I Available Source II Available Source I Accepted (Load Connected) Source II Accepted (Load Connected) Center-off Position Control Mode Manual/Automatic Source I Priority No Source Priority Source Sensing Setting Phase Selection Source I Voltage Source II Voltage Source I Frequency Source II Frequency Source I power loss Source II power loss Source I phase loss Source II phase loss Source I Voltage Dropout (Undervoltage) 70% or 85% 70% to 98% Source II Voltage Dropout (Undervoltage) 70% or 85% 70% to 98% Source I Overvoltage Trip OFF or 120% 1 102% to 120% or OFF 1 Source II Overvoltage Trip OFF or 120% 1 102% to 120% or OFF 1 Source I Overfrequency Transfer 110% or 115% 102% to 115% Source II Overfrequency Transfer 110% or 115% 102% to 115% Source I Frequency Dropout (Underfrequency) 85% or 90% 85% to 98% Source II Frequency Dropout (Underfrequency) 85% or 90% 85% to 98% Source I Voltage Pick Up 75% or 90% 85% to 100% Source II Voltage Pick Up 75% or 90% 85% to 100% Source I Frequency Pick Up 90% or 95% 90% to 100% Source II Frequency Pick Up 90% or 95% 90% to 100% Time Delay Setting Override Momentary Source I Outage 0 to 3 Seconds 0 to 3 Seconds Override Momentary Source II Outage 0 to 3 Seconds 0 to 3 Seconds Source I 1s to 30 Minutes 0 to 30 Minutes Source II 0 to 5 Minutes 0 to 5 Minutes Engine Cooldown 5 Minutes Fixed 0 to 60 Minutes Center-Off Position Delay OFF or 5 Seconds 0 to 5 Seconds Others RS-485 Modbus 24VDC Capable Generator Control Signal Output Fire Control Signal Input Alarm Auxiliary Contact Optional Optional Events Log Display Type LED LED+LCD Installation Din rail installation and Panel installation Panel installation Controller with Energy Storage optional -Yes, Standard Blank-Not Available/ Not Applicable 1 the controller used on 415V, its Overvoltage Droupout is 115% both on Source I and Source II 11

C1000 Controller Port Function Description 24V Generator Start Alarm Fire Control Input Position O Position I Position II GEN ALM FIRE DI5 DI6 DI7 X3 User Terminal C1000 CONTROLLER X1 Power Terminal Voltage Detection X2 Control Terminal Transfer Switch Position Detection and Transfer Control To Transfer Switch X1 To Transfer Switch X2 12

C1000 with RS485 Controller Port Function Description 24V RS485 72D Generator Start Alarm Fire Control Input Position O Position I Position II RS485 GEN ALM FIRE DI5 DI6 DI7 485 Port X3 User Terminal X4 C1000 CONTROLLER X1 Power Terminal Voltage Detection X2 Control Terminal Transfer Switch Position Detection and Transfer Control To TS X1 To TS X2 13

C2000 Controller Port Function Description 24V Alarm O I II TS Position Generator Start RS485 Fire Control Input Position O Position I Position II ALM DO1 DO2 DO3 GEN 485 PORT FIRE DI5 DI6 DI7 X4 User Terminal C2000 CONTROLLER X1 Power Terminal X2 Control Terminal X3 User Terminal Voltage Detection Transfer Switch Position Detection and Transfer Control 24V DC Power Input Lost Power To Transfer Switch X1 To Transfer Switch X2 24V 14

C2000 Controller with Energy Storage Appearance Port Function Description 24V Alarm O I II TS Position Generator Start RS485 Fire Control Input Position O Position I Position II ALM DO1 DO2 DO3 GEN 485 PORT FIRE DI5 DI6 DI7 X4 User Terminal C2000 CONTROLLER X1 Power Terminal X2 Control Terminal X3 User Terminal X5 Voltage Detection Transfer Switch Position Detection and Transfer Control 24V DC Power Input Lost Power C.Output To TS X1 To TS X2 24V Energy storage out put 1H 15

Controller Dimensions and Weight* C1000 Controller 80.7 58.7 93.5 94±0.5 C2000 Controller 191±1 80 86 132 47±0.5 46.2 111.5 Panel Opening Dimensions Weight: 0.74kg (unit: mm) Run Auto Alarm 142 Source I Source II UP 134±1 Transfer Switch Position Esc Down Enter 189 197 Panel Opening Dimensions Weight: 1kg (unit: mm) *Not Shipping weight, Actually unit weight 16

Critical Loads Demand ASCO C2000 Controller with Energy Storage Appearance 128.7 122.2 189.0 Run Auto Alarm 142.0 Source I Source II 132.0 UP Esc Enter Transfer Switch Position Down 197.0 Weight: 1.64kg (unit: mm) 17

About Emerson Network Power Emerson Network Power, a business of Emerson (NYSE:EMR), protects and optimizes critical infrastructure for data centers, communications networks, healthcare and industrial facilities. The company provides new-to-the-world solutions, as well as established expertise and smart innovation in areas including AC and DC power and renewable energy, precision cooling systems, infrastructure management, embedded computing and power, integrated racks and enclosures, power switching and controls, and connectivity. Our solutions are supported globally by local Emerson Network Power service technicians. Learn more about Emerson Network Power products and services at www.emersonnetworkpower.com About Emerson Emerson (NYSE: EMR), based in St. Louis, Missouri (USA), is a global leader in bringing technology and engineering together to provide innovative solutions for customers in industrial, commercial, and consumer markets around the world. The company is comprised of five business segments: Process Management, Industrial Automation, Network Power, Climate Technologies, and Commercial & Residential Solutions. Sales in fiscal 2012 were $24.4 billion. For more information, visit: www.emerson.com Legal statement: While every precaution has been taken to ensure accuracy and completeness herein, Emerson assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications subject to change without notice. Emerson Network Power Co., Ltd. Address: No.1 Kefa Road, Science & Industry Park, Nanshan District, 518057 Shenzhen China Telephone: 86-755-86010808 Postcode: 518057 Pre-sales hotline: 400-887-6526 After-sales hotline: 400-887-6510 www.emersonnetwork.com.cn Emerson Network Power, ASCO, the Emerson Network Power logo and ASCO logo are trademarks and service marks of Emerson Electric Co. 2013 Emerson Electric Co. E-X6216497-1113