Series 230 Automatic Transfer Switch

Similar documents
Series 230 Automatic Transfer Switch

ASCO SERIES 230 Automatic Transfer Switch

Series 230 Automatic Transfer Switch

SERIES 230 Automatic Transfer Switch C1000 Intelligent Controller User Manual

MSR 2400R. Rugged Power System for Military and Heavy Duty Applications

SERIES 230 A2ADTL Transfer Switch User Manual

ASCO 920 Remote Control (RC) Switches

4000 SERIES Power Transfer Switches Product Features

SERIES 230 C2ADTL Transfer Switch User Manual

Maximum Reliability & Excellent Value. Features. UL Listed Withstand & Close-On Ratings. Series 300 Power Transfer Switches

Residual overvoltage relay

Model KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.

920 Remote Control (RC) Switches

RT4F-120V/20A-WAC RECTIFIER

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A

RT12-240V/2.4kW Rectifier Specification

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

Model KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.

SECTION 16496E ATS MOLDED CASE WITH ATC 900 CONTROLLER

RT4F-48V/50A-WAC RECTIFIER

RT4F-110V/25A RECTIFIER

Chloride CROSS Rack 16 A, 32 A and 63 A

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

Series 300 POWER TRANSFER SWITCHES MAXIMUM RELIABILITY & EXCELLENT VALUE FEATURES

RT4B-110V/12A RECTIFIER

AI561 Analog Input Module

Contact protection relay

DC561, digital input/output module,

ASCO SERIES 300 Manual Transfer Switch Solutions

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

UPS. centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw INFINITE POWER. Mission Critical Applications

Uninterruptible Power Supplies

DX561 Digital Input/Output Module

DC562, digital input/output module,

AO523 Analog Input Module

MSR 2400W. Multi purpose Power System for Telecom and Industrial Applications. Nominal Output Voltage. Voltage Setting Range

MAXIOM. Data Sheet. Lighting Relay Panel. Overview Leverage the Power of BAS Integration

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

TECHNICAL DESCRIPTION

Lightning and Surge Arresters

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

ASCO SERIES 300 Service Entrance Power Transfer Switch

DI572 Digital Input Module

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D

DI561 Digital Input Module

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing

CI-tronic Reversing contactor Type RCI

SmartOnline 240/208/120V 8kVA 5.6kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, Split-Phase input, Bypass Switch

Bulletin 290/291 ArmorStart LT Distributed Motor Controllers Specifications

SMARTONLINE E3 UPS SYSTEMS

60103 Circuit Breaker

RT7-48V/6kW Specification

PSC-AC. PSC AC-series W 1 to 3 Outputs. AC-DC Power supply. Input Voltage ranges. Single output ratings. 2-3 outputs ratings

Cashpower Three Phas e

SmartOnline 208/120V or 240/120V 16kVA 11.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 8U Rack/Tower, USB, DB9 Serial

SOCOMEC SIRCOVER MANUALLY OPERATED CHANGEOVER SWITCHES

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

Residual Current Devices FRCdM Type B, B+ and Bfq Digital

Powerterm L144R Transformer/Rectifier Model C2260C four channel 12V/1.5A Transformer/Rectifier Module with Remote Control

TU531, TU532 Terminal Unit

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.

Model: KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.

Feeder protection relay SPAA 121 C. Product Guide

FTA750 LIMITED SERVICE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

Rugged MediaConverter

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)

Siemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities.

Sensitive definite time or inverse time earth-fault stage for back-up residual earthfault

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

Hipulse-U UPS 80kVA - 500kVA Utmost Reliable Power Solution for Critical Business Applications

Earth-fault Relay SPAJ 110 C. Product Guide

SmartOnline SVTX Series 3-Phase 380/400/415V 30kVA 27kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

Phase loss monitor CM-PBE Phasemonitor for over and undervoltage CM-PVE Ordering details

SITOP in the SIMATIC Design

AX521 Analog Input/Output Module

Surge Protection Devices Ex9UE2

RTU560. CT/VT Interface 560CVT10. Meter Operation. Application. Characteristics. Data Sheet CT/VT Interface 560CVT10. Instantaneous Meter Values

PowerLogic power-monitoring units. PM1000 series power meter. Technical data sheet

Bulletin 294 ArmorStart LT Distributed Motor Controllers Feature Diagram

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

TF501, TF521 Terminal Bases

SEL-734B Data Sheet. Advanced Monitoring and Control System. Major Features and Benefits

Overvoltage Protection Devices

AX522 Analog Input/Output Module

LOW VOLTAGE BYPASS/ISOLATION BREAKER BASED AUTOMATIC TRANSFER SWITCHES SECTION 16496D

CI542 PROFIBUS Communication Interface Module

DC532-XC, digital input/output module,

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

ASCO Power Transfer Load Centers. Power Switching & Controls for Business-Critical Continuity

Monitoring Technique. VARIMETER PRO Multifunction Measuring Relay MK 9300N, MH 9300

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.

Voltage Sag Simulator

NPW800R RETROFITTING. Power and Volatge Protection Relay

Higher Availability: Self-diagnostics. Automatically tests unit electronics and batteries. Designed to simplify maintenance and troubleshooting.

AO561 Analog Output Module

Section 4 Ground-Fault Protection Devices

NEW Series SSH Output to 75A, 510 Vac with Diagnostics High Industrial Performance (HIPpak) Solid-State Relays

Transcription:

Series 230 Automatic Transfer Switch

The Recognized Leader in Power Transfer Switch Technology Offers the Most Advanced Transfer Switches in the World. Application Product Overview The Series 230 automatic transfer switch consists of an intelligent controller and a modular load break switch which automatically transfers the load to the emergency power source when it detects the normal power source under/over voltage, under/over frequency, or phase loss. The switch has three operational positions (Source I, Center-off, Source II). The two sources are isolated when the switch is in the centeroff position. A center-off position locking mechanism is also provided. The Series 230 transfer switch is rated up to 800A and is available from 220 to 415 volts for both 50 and 60 Hz, single and three phase. Typical applications include commercial and residential buildings, hospitals, telecom, subway and transportation, data centers, military and fire pumps. Parameter Rated Operational Current Ie (A) 16 32 63 80 100 125 160 200 225 250 315 400 500 630 800 Rated Insulation Voltage U i (V) 800 1000 1000 1000 1000 Rated Impulse Withstand Voltage U imp (kv) 8 8 12 12 12 Rated Operation Voltage U e (V) 220, 230, 240, 380, 400, 415 Rated Frequency (Hz) 50 / 60 Poles 2,4 2, 3, 4 Rated Short-Time Withstand Current I cw (ka, RMS) 6 (0.03s) 10 (0.1s) 15 (0.1s) 25 (0.1s) 40(0.1s)/ 20(1s) Rated Short-Circuit Making Capacity I cm (ka, PEAK) 8 17 31.5 65 80 Withstand and Close-On Rating I q (ka) When Used With Current Limiting Fuses When Used With Specific Circuit Breakers 65 65 200 200 200 15 50 150 150 80 Making and Breaking Capacity 10 I e Mechanical Operation Performance (cycles) 10,000 Utilization Category AC-32A, AC-33B Operation Voltage range (AC) EMC Class Wiring Way Separate Lock Mechanism Ue=220V / 230V / 240V / 380V / 400V Ue= 415V 125 300V (L-N) (0.7 1.2) Ue (0.7 1.15) Ue Class A Front Standard Auxiliary Contact (Optional) 4 contacts maximum 8 contacts maximum 1

Series 230 Automatic Transfer Switch Product Features Performance Features Meets or exceeds the requirements of the following regulatory agencies EN60947-6-1/IEC60947-6-1: Transfer Switching EN60947-3/IEC60947-3: Suitable for Isolation EN55022: Radiated and Conducted Emission, Class A EN61000-3-2: Harmonic Current Emission, Class A EN61000-3-3: Limits of Voltage fluctuation and Flicker EN 61000-4-5: Immunity to Surge EN 61000-4-4: Immunity to Electrical Fast Transient EN61000-4-2: Immunity to Electrostatic Discharge EN61000-4-3: Immunity to Radiated Electric Fields EN 61000-4-6: Immunity to Continuous Conducted Interference Structure PC Class ATS High ability to withstand lightning strikes (40kA 8/20μs) Simple reliable mechanism, compact and stylish appearance Modular design, convenient operation, easy maintenance Three operating positions. Both sources can be isolated in a center-off position Arc Extinguish The utilization categories are AC-32A, AC-33B, and the ability to withstand and break is10 I e Rotating dual contact design extinguishes the arc quickly and effectively Arcing contacts and main contacts are separate; main contacts are protected from arc damage Wiping-action contacts are self cleaning High short-circuit closing ratings Switching Mechanism Automatic, manual and remote operation are available Unique contacts design limits contact bounce Unique clutch design makes manual operation easy and low force Electrical and mechanical interlocks prevent two sources from connecting simultaneously Innovative motor circuit protection ensures precision operation Cast steel bevel gear mechanism provides high transmission efficiency, and extends operating life Controller Different Operating Modes (Source I priority / No Source priority) C300 and C2000 can work with an external 24VDC power supply High frequency switching power supply, and wide power voltage range Data (e.g. Event log, Setting, etc) remains intact if power is lost Intelligent fault diagnostics enable selfprotecting motor feature RS485 communication interface is available Priority Source Swap 2

Make Life and Business More Reliable By Using ASCO Series 230 Transfer Switch Ordering Information To order an ASCO Series 230 Automatic Transfer Switch, complete the following catalog number: E2ADTL B3 0800 H D X 0 1H Frame size Poles Amperes Continuous Rating Voltage Code Controller Options Enclosure Optional Accessories A2ADTL B2ADTL C2ADTL 16 80A Frame 100 160A Frame 200 250A Frame B1: 2 Poles (L-N) (2-wire with Neutral) 02: 2 poles (L-L) (2-wire without Neutral) 0016, 0032 0063, 0080 0100, 0125 D E F 220V 230V 240V B D E C300* C1000 C2000 Insert X If optional accessories are required O C Q Open type IP20 IP54 132JA 132JC B2ADTL Frame BusBar 132A 132F Auxiliary Contacts D2ADTL E2ADTL 315 400A Frame 500 800A Frame B2: 3 Poles (3-wire with Neutral) 03: 3 Poles (3- wire without Neutral) B3: 4 Poles (4-wire with Neutral ) 0160, 0200 0225, 0250 0315, 0400 0500, 0630 0800 H J K 380V 400V 415V 72D C300, C1000 with RS-485 1H C2000 with Energy Storage * The A2ADTL frame is only available with the embedded C300 controller 3

Optional Accessory Model Description and Order Information B2ADTL Frame Bridging Bus Bar 132 J A Poles A: 2 poles (02356097) B: 3 poles (02357091) C: 4 poles (02355942) Function Code 132J: Bridging Busbar 4 pole Bridging Busbar For example: 132JC, means Bridging Busbar for a 4 pole transfer switch Auxiliary Contacts 132 A A Auxiliary Contact Quantity BLANK: 1 contact A: 2 contacts B: 3 contacts C: 4 contacts Function Code 132A-132F: Auxiliary Contact Auxiliary Contact For example: 132BA, means 2 sets of contacts, which close when the ATS transfers to the Source II position. 4

Auxiliary Contact Definition 132A-132C : The auxiliary contacts can be used to indicate position with the CLOSE contact, see Schematic 1. 132D-132F: The auxiliary contacts can be used to indicate position with the OPEN contact, see Schematic 2. Position of The Transfer Switch Auxiliary Contact Function Code 132A 132B 132C Position of The Transfer Switch Auxiliary Contact Function Code 132D 132E 132F I I O O II II Auxiliary Contact Code LAP1F100 (16021426) LAP1F010 (16021427) - - - Auxiliary Contact Code LAP1F100 (16021426) LAP1F010 (16021427) - - - Auxiliary Contact Mounting Position (only showing C2ADTL, D2ADTL, E2ADTL). Auxiliary Contact Mounting Position (only showing C2ADTL, D2ADTL, E2ADTL). 72D C300 or C1000 Controller with RS-485 interface A RS485 interface installed in the C300 or C1000 controller to enable serial communications, supporting MODBUS protocol. This Accessory can only be installed in the factory. Use accessory code 72D when ordering this function. 1H C2000 Controller with energy storage The optional controller with energy storage (Accessory 1H) has an added feature to switch the transfer switch to the center-off position during Source I and Source II failure at the same time. The controller will remain in center-off until either Source I or Source II power is restored and voltage and frequency are both stable. This optional feature can work in Source I Priority and No Source Priority operating modes. This feature is available only after the controller has been powered by AC input for at least10 minutes to charge a capacitor. This Accessory can only be installed in the factory. Use accessory code 1H when ordering this function. 5

Avoid Losing Critical information When Power is Lost Series 230 Dimensions and Weight A2ADTL Frame A 20.5mm(0.81") 108mm(4.25) B A2ADTL 2P 4P Size (mm) A 216.0 252.0 Weight (kg) 1.6 2.0 Note: unit must be installed in the cabinet using a DIN35 rail B2ADTL Frame 112mm(4.4") 117mm(4.6") 104mm(4.1") 78mm(3.1") 29mm(1.1") 184mm(7.2") 126mm(5.0") 214mm(8.4") 93mm(3.66") 96mm(3.78") 107mm(4.21") 121.3mm(4.77") 124mm(4.88") 110mm(4.33") 45mm(1.77") 120mm(4.72") Ă4.5mm(Ă0.18") 171mm(6.73") 18mm(0.71") C Unit: mm(inch) 27mm(1.1") 15mm(0.6") A Unit: mm(inch) B2ADTL 2P 3P 4P Size (mm) A 241.0 349.0 349.0 Weight (kg) 2.6 2.8 2.8 Note: unit must be installed in the cabinet using a DIN35 rail 6

C2ADTL Frame 168mm(6.6") Ø6mm(Ø0.2") 12.5mm(0.5") 20mm(0.8") 9mm(0.4") 194mm(7.6") 182mm(7.2") 50mm(2.0") 128mm(5.0") 172mm(6.8") 23.5mm(0.9") 150.5mm(5.9") 9mm(0.4") 130mm(5.1") 116mm(4.6") 100mm(3.9") 6mm(0.2") 177mm(32.8") 7.5mm(0.3") B A 34mm(1.3") C 126mm(5.0") Unit: mm(inch) C2ADTL 2P 3P 4P A 251.0 285.0 319.0 Size (mm) B 236.0 270.0 304.0 C 68.0 102.0 136.0 Weight (kg) 4.6 5.2 5.8 D2ADTL Frame 173mm(6.8") 15.5mm(0.6") 25mm(1.0") 10mm(0.4") 228mm(9.0") 215mm(8.5") 52mm(2.0") 144mm(5.7") 199mm(7.8") 2.5mm(0.1") 186mm(7.3") 158mm(6.2") 140mm(5.5") 120mm(4.7") 10mm(0.4") Ø7mm(Ø0.3") 206mm(8.1") B A 44mm(1.7") C 120mm(4.7") Unit: mm(inch) D2ADTL 2P 3P 4P A 317.0 361.0 405.0 Size (mm) B 297.0 341.0 385.0 C 103.0 147.0 191.0 Weight (kg) 8.6 9.8 11.0 7

ASCO Power Transfer Switch Solutions for Powerful Peace of Mind E2ADTL Frame 180mm(7.1") 8mm(0.3") 10mm(0.4") 252mm(10.0") 240mm(9.5") 57mm(2.3") 165mm(6.5") 226mm(8.9") 290mm(11.4") 265mm(10.4") 208mm(8.2") 160mm(6.3") Ø9mm(Ø0.4") 228mm(9.0") 14mm(0.6") 65mm(2.6") B A 13mm(0.5") 45mm(1.8") C 19mm(0.7") 174mm(6.9") 195mm(7.7") Unit: mm(inch) E2ADTL 2P 3P 4P A 384 449 514 Size (mm) B 357 422 487 C 146 211 276 Weight (kg) 14 17 20 Shipping Dimensions and Weights (Including TS and controller, without options) Frame Width (mm) Height (mm) Depth (mm) Weight (kg) with C300 Weight (kg) with C1000 Weight (kg) with C2000 2P 4P 2P 3P 4P 2P 3P 4P A2ADTL 310 170 175 1.9 2.3 B2ADTL 602 220 267 4.9 5.5 5.7 5.2 5.8 6.0 C2ADTL 602 335 227 8.9 9.5 10.1 9.2 9.8 10.4 D2ADTL 650 350 300 13.0 14.5 16.0 13.4 14.9 16.4 E2ADTL 767 350 352 16.0 19.0 22.0 16.5 19.5 22.5 * All information is subject to change, for the latest information please contact ASCO sales team. 8

Series 230 Controller Feature Comparisons C300 Controller Voltage and Frequency Sensing Single phase under and over voltage settings on Source I and Source II Phase loss sensing on Source I and Source II Under and over frequency settings on Source I and Source II Time Delays Time delay sensing accuracy is ±1% Transfer time delay can be set manually Controller Display and Keypad LED display Touch key for clearing alarm and manual operation Switch position indicator lights Source acceptability indicator lights Operating Modes Automatic and manual operation available Source I Priority/ No Source Priority Priority Source Swap Center-off with time delay and center-off with protection The center-off time delay can be set to avoid large current inrush to inductive loads Center-off with protection is available to protect critical loads (e.g. Fire Pump) Remote Control and Communication Can control switch remotely (e.g. Position Control, Time Delay, etc.) Fire control signal input (24VDC) Power Supply of Controller Operation Voltage (VAC): 220/ 230/ 240 C300 has ability to work with 24VDC power supply 9 C1000 Controller Voltage and Frequency Sensing Single phase under and over voltage settings on Source I and Source II Phase loss sensing on Source I and Source II Under and over frequency settings on Source I and Source II Time Delays Time delay sensing accuracy is ±1% Transfer time delay can be set manually Controller Display and Keypad LED display Touch pad for clearing alarm and manual operation Switch position indicator lights Source acceptability indicator lights Operating Modes Automatic and manual operation available Source I Priority/ No Source Priority Priority Source Swap Center-off with time delay and center-off with protection The center-off time delay can be set to avoid large current inrush to inductive loads Center-off with protection is available to protect critical loads (e.g. Fire Pump) Remote Control and Communication Can control switch remotely (e.g. Position Control, Time Delay, etc.) Fire control signal input (24VDC) Power Supply of Controller Operation Voltage (VAC): 220/ 230/ 240/ 380/ 400/ 415 C2000 Controller Voltage and Frequency Sensing 3-Phase under and over voltage settings on Source I and Source II Under and over frequency settings on Source I and Source II Voltage unbalance detection between phases Time Delays Time delay can be set by operating parameter setting menu Time delay sensing accuracy is ±1% Time delay can be set under different working modes Transfer time delay can be set manually Controller Display and Keypad LCD display Touch pad for programming the features and settings Switch position indicator lights Source acceptability indicator lights Operating Modes Automatic and manual operation available Source I Priority/ No Source Priority Priority Source Swap Center-off with time delay and center-off with protection The center-off time delay can be set to avoid large current inrush to inductive loads Center-off with protection is available to protect critical loads (e.g. Fire Pump) Events Display Event log displays: 100 most recently logged events with time and date of each event, event type and event reason Remote Control and Communication Uses RS485 interface, and supports MODBUS Communication Can control switch remotely (e.g. Position Control, Time Delay, etc.) Fire control signal input (24VDC) Power Supply of Controller Operation Voltage (VAC): 220/ 230/ 240/ 380/ 400/ 415 C2000 has ability to work with 24VDC power supply

24-hour Protection No Matter When Trouble Strikes C300 C1000 C2000 Rated Operation Voltage Ue(V) 220/230/240 220/230/240/380/400/415 220/230/240/380/400/415 Rated Frequency (Hz) 50/60Hz 50/60Hz 50/60Hz Display Indicator Source(I,II) Available ATS Position Control Mode Manual/Automatic Source I Priority No Source Priority Remote Control Unique Control Funcation Remote control Priority (1) Priority Source Swap (2) Center-off with protection when Source I and II are lost (3) Optional Diagnosis fault intelligent with self -protection function Source Sensing Setting Voltage Sensing (4) L1-N,L2-N,L3-N L1-L3 L1-L2,L2-L3,L3-L1 Frequency Sensing Power loss Phase loss (5) L1,L2,L3 L1,L3 L1,L2,L3 Undervoltage 65%, 70%, 80%, 85% 70%, 85% 70% 98% Overvoltage (6) 120% / OFF 120% / OFF 102% 120% / OFF Overfrequency Transfer 115% 115% 102% 115% Underfrequency Transfer 85% 85% 85% 98% Time Delay Setting Override Momentary Source Outage 1s 1s 0 3s Transfer to Source II 0s, 5s, 30s, 5min 0 5min 0 5min Transfer to Source I 1s, 30s, 5min, 30min 1s 30min 0 30min Engine Cooldown 2min 2min 0 60min Center-Off Position Delay OFF / 5s OFF / 5s 0 5s Others RS-485 Optional Optional Additional 24V DC Power Input Generator Control Signal Output Fire Control Signal Input Alarm Auxiliary Contact Optional Optional Optional Event Log Display Type LED LED LED+LCD Installation DIN rail installation and Panel installation DIN rail installation and Panel installation :Yes, Standard; Blank: Not Available/ Not Applicable Remarks: 1. Only available for source priority mode 2. C1000 controller with priority swap function requires special soft ware to be field installed 3. Need to use controller with energy storage (Accy 1H) 4. For C300 controller, Source II Voltage sensing is only on L1 5. For C300 controller, Source II Phase loss sensing is only on L1 6. When the controller is used on 415V, its Overvoltage Droupout is 115% both on Source I and Source II Panel installation 10

C300 Controller Port Function Description Accessory 72D Optional RS485 Port 24V 24V RS485 72D 24V DC Power Input Generator Start Alarm Fire Control Input Transfer to Position O Transfer to Position I Transfer to Position II Push to test RS485 GEN ALM FIRE DI 1 DI 2 DI 3 DI 4 485 Port 11

C1000 Controller Port Function Description Accessory 72D Optional RS485 Port 24V RS485 72D Generator Start Alarm Fire Control Input Transfer to Position O Transfer to Position I Transfer to Position II RS485 GEN ALM FIRE DI5 DI6 DI7 485 Port X3 User Terminal X4 C1000 CONTROLLER X1 Power Terminal Power and Voltage Detection X2 Control Terminal Transfer Switch Position Detection and Transfer Control To Transfer Switch X1 To Transfer Switch X2 12

C2000 Controller Port Function Description 24V Alarm O I II TS Position Generator Start RS485 Fire Control Input Transfer to Position O Transfer to Position I Transfer to Position II ALM DO1 DO2 DO3 GEN 485 PORT FIRE DI5 DI6 DI7 X4 User Terminal C2000 CONTROLLER X1 Power Terminal X2 Control Terminal X3 User Terminal X5 Power and Voltage Detection Transfer Switch Position Detection and Transfer Control 24V DC Power Input Lost Power Capacitor. Output To Transfer Switch X1 To Transfer Switch X2 24V Energy storage output Accessory 1H Optional Built-In Capacitor used as a (rechargeable) one-time motor-control transfer after complete power loss. This accessory also requires a different connector board on the Transfer Switch Unit. 1H 13

Critical Loads Demand ASCO Controller Dimensions and Weight* C1000 Controller (With or Without optional 72D Accessory) 80.7 58.7 93.5 94±0.5 C2000 Controller 191±1 80 132 86 142 47±0.5 46.2 111.5 Panel Opening Dimensions Weight: 0.74kg Unit: mm(inch) Run Auto Alarm Source I Source II UP 134±1 Transfer Switch Position Esc Down Enter 189 197 Panel Opening Dimensions Weight: 1kg Unit: mm(inch) 14

Critical Loads Demand ASCO C2000 Controller with Energy Storage (Accessory 1H) 128.7 122.2 189.0 Run Auto Alarm 142.0 Source I Source II 132.0 UP Esc Enter Transfer Switch Position Down 197.0 Weight: 1.64kg Unit: mm(inch) *Not Shipping weight, Actual unit weight 15

About Emerson Network Power Emerson Network Power, a business of Emerson (NYSE:EMR), protects and optimizes critical infrastructure for data centers, communications networks, healthcare and industrial facilities. The company provides new-to-the-world solutions, as well as established expertise and smart innovation in areas including AC and DC power and renewable energy, precision cooling systems, infrastructure management, embedded computing and power, integrated racks and enclosures, power switching and controls, and connectivity. Our solutions are supported globally by local Emerson Network Power service technicians. Learn more about Emerson Network Power products and services at: www.emersonnetworkpower.com About Emerson Emerson (NYSE: EMR), based in St. Louis, Missouri (USA), is a global leader in bringing technology and engineering together to provide innovative solutions for customers in industrial, commercial, and consumer markets around the world. The company is comprised of five business segments: Process Management, Industrial Automation, Network Power, Climate Technologies, and Commercial & Residential Solutions. Sales in fiscal 2013 were $24.7 billion. For more information, visit: www.emerson.com Official Wechat Official Weibo Legal statement: While every precaution has been taken to ensure accuracy and completeness herein, Emerson assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications subject to change without notice. Emerson Network Power Co., Ltd. Address: Block B2 Nanshan Park No.1001 Xueyuan Road Nanshan Dist. Shenzhen, 518055 China China Telephone: 86-755-86010808 Postcode: 518055 Pre-sales hotline: 400-887-6526 After-sales hotline: 400-887-6510 www.emersonnetwork.com.cn Emerson Network Power, ASCO, the Emerson Network Power logo and ASCO logo are trademarks and service marks of Emerson Electric Co. 2015 Emerson Electric Co. E-X6216497-0915