Vaisala HUMICAP Structural Humidity Measurement Kit SHM40. Full SHM40 product presentation and introduction to the borehole method

Similar documents
The industrial humidity transmitter

The industrial humidity transmitter

USER'S GUIDE. Vaisala HUMICAP Indicator HMI41 and Probes HMP41/45/46 M210316EN-A

HMT330 Series Humidity and Temperature Transmitters for Industrial Applications

DMT345 and DMT346 Dewpoint Transmitters

PTU300 Combined Pressure, Humidity and Temperature Transmitter

testo Probe series testo 661x The industrial humidity transmitter We measure it. SPECIFICATIONS testo Probe series testo 661x

In order to minimize the impact of rain, snow, ice and solar radiation on the measurement the EE33-M must be mounted inside a radiation shield.

Supplied with. Calibration certificate. HD 200 Hygrometer

DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions

DPL4000 Portable Low Range Dew Point Analyzer

testo Probe series testo 661x The industrial humidity transmitter Committing to the future

HMT330 Series Humidity and Temperature Transmitters for Industrial Applications

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310

EE211. Humidity and Temperature Transmitter for Continuous High Humidity. Features. 42 v1.3 / Modification rights reserved EE211 EE211

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

USER'S GUIDE. Vaisala HUMICAP Hand-Held Humidity and Temperature Meter HM70 M210297EN-E

HLX31 Series. Multifunctional Industrial Transmitter for Humidity / Temperature / Dew Point / Absolute Humidity... Model A. Model B.

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310

EE210. Humidity and Temperature Transmitter for Demanding Climate Control. Applications. Features. 36 v2.5 / Modification rights reserved EE210

MMT330 Series Moisture and Temperature Transmitters for Oil

HMT330 Series Humidity and Temperature Transmitters

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Humidity transmitter for critical climate applications

HMT330 Series Humidity and Temperature Transmitters for Demanding Humidity Measurement

DMT340 Series Dew Point and Temperature Transmitters

HMT330 Series Humidity and Temperature Transmitters for demanding humidity measurement

Environmental Conditions C - remote sensing probe up to 120 C (248 F)

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

HMT330 Series Humidity and Temperature Transmitters for Demanding Humidity Measurement

EE32/33 Series. Humidity / Temperature Transmitter for High Humidity and Chemical Applications. Typical Applications. Features

CAEL-DP Series Dew Point Transmitter for Industrial Control

Advanced Test Equipment Rentals ATEC (2832) HMP45A&HMP45D HUMIDITY AND TEMPERATURE PROBES Operating Manual

Humidity goes Digital

Click Here for PRICE LIST TABLE OF CONTENTS

USER S GUIDE. EE211 - Heatead Humidity and Temperature Transmitter for High Humidity Applications GENERAL ASSEMBLY SCOPE OF SUPPLY CAUTION

M212022EN-A. User Guide. Vaisala HUMICAP â Humidity and Temperature Probes HMP4, HMP5, HMP7, HMP8, TMP1

Dual Moisture Meter Pin / Pinless Moisture Meter

Instruction Manual. T3110 T3110L T3110Ex

) a Direct Measure of Oil Quality. Water Activity (a w

PTU200 Transmitter. Measuring Barometric Pressure, Humidity and Temperature

2YL-T15-4M & 2YL-T16-4M Thermocouple Loggers. 2YL-M36-4M & 2YL-M37-4M Multi Terminal Input Loggers. 2YL-M61-4M & 2YL-M62-4M Lux Loggers

DMT PERFORMING UNDER PRESSURE DMT. Applications. Special features. Description 1/9

ON/OFF HUMIDIFIER CONTROL (ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET OVERVIEW WALL CONTROLLER INSTALLATION (TCY-BH-T-U)

sensor, which compensates for ageing effects, is highly insensitive to pollution and offers outstanding long term stability.

PosiTector DPM. Dew Point Meter. INSTRUCTION MANUAL v Simple. Durable. Accurate.

Air data test indicator Model CPA2501

Precision hand-held pressure indicator Model CPH6400

DBC 150/650 Series. Druck Dry Block Temperature Calibrators. GE Sensing. Features

Hand-Held Pressure Indicator

Your Eye Inside. VIDEO BORESCOPES Made in USA. The next generation of fully-portable, articulating videoscopes!

Programmable transmitter of temperature, relative humidity and other derived humidity values with 0 to 10 V outputs Instruction Manual

USER S GUIDE. EE210 - Humidity and Temperature Transmitter for demanding Climate Control Applications GENERAL

HygroPalm 0. Portable Humidity Temperature Indicator. Instruction Manual

User manual. paper moisture meter humimeter RH5 with sword sensor

Precision digital pressure gauge Model CPG1500

14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page

Precision digital pressure gauge Model CPG1500

Hand-Held Thermometer Model CTH 6200

Hand-Held Pressure Indicator Model CPH6200-S1 Model CPH6200-S2 (2-channel version)

GA-12. madur Polska sp. z o.o.

Multi Units Humidity/Temperature Transmitter. HygroViewer Model JW300 User Manual

Additel 760 Automatic Handheld Pressure Calibrator

Portable low-pressure controller Model CPC2000

SigmaCheck. Fully Featured Eddy Current Conductivity Meter ET NDE

C100 Portable Multifunction

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

ProcessCalibrator Model CPH6000

! Ranges from -45º to 650ºC. ! Rapid heating, cooling and settling. ! Switch test, ramp, step and preset functions

Precision digital gas density indicator Model GDI-100-D

Intelligent Operator Panel for SINAMICS G converters siemens.com/sinamics-accessories

User Manual. Thermohygrometer. Model with NIST-Traceable Calibration THE STANDARD IN PRECISION MEASUREMENT

HygroLog HL20 and HL21 Data Logger. User Guide

Additel 760 Automatic Handheld Pressure Calibrator Selection Guide

HI HI N HI HI

Technical Information Liquiline To Go CYM290 and Liquiline To Go Ex CYM291

Temperature and humidity regulator H3020 H3021 H3023 H3027. Instruction Manual

HygroPalm. Portable Humidity Temperature Indicator. Instruction Manual

Outdoor Temperature Humidity and Light Level Sensor

PMI Borescope Lizard 100 Series User Guide

Temperature/Humidity Data Logger with 2 External Inputs

4 AA nickel-etal bybrid cells (min. 2,200 mah) Use only AC Adapter (5 VDC / min. 1 A) supplied for recharging

Hand-held pressure indicator Model CPH6300-S1 (1-channel version) Model CPH6300-S2 (2-channel version)

USER'S GUIDE. Vaisala HUMICAP Humidity and Temperature Transmitters HMW90 Series M211399EN-F

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )

Your Eye Inside VIDEO BORESCOPES. The next generation of fully-portable, articulating videoscopes!

Operating manual XA1000 / XP200 / XP400

HygroLog HL20 and HL21 Data Logger. User Guide

Data logger / EASYBus

Hand-held thermometer Model CTH6200

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

HI 9828 Multiparameter Water Quality Meter...

PORTABLE VIDEO BORESCOPE. User Manual

Portable pressure calibrator Model CPH7600

Humidity goes Digital

HI 9828 Multiparameter Water Quality Meter...

Differential Pressure Monitoring in Cleanroom Technology

A1H Portable Humidity Temperature Indicator Instruction Manual

Intrinsically safe Hand-Held Pressure Indicator (ATEX-version) Model CPH62I0

Hand-held thermometer Model CTH6200

Transcription:

Vaisala HUMICAP Structural Humidity Measurement Kit SHM40 Full SHM40 product presentation and introduction to the borehole method

SHM40 a starter kit ideal for the borehole method Practical tool for humidity measurement of concrete and other structures Designed for the borehole method Based on the HM40 indicator and HMP40S probes Accessories and weather-proof case SHM40 and accessories (e.g. HM40S, HMP40S, HM40SINDI) are non-configurable items Page 2 / 2014-09-25 / MRU / Vaisala

SHM40 Page 3 / 2014-09-25 / MRU / Vaisala

Features and Benefits Easy to use Accurate measurement data in a stabilization graph Truly interchangeable HMP40S measurement probes HMP40S is a cable probe with HMP110 and cable with quick connector Durable IP65 classified measurement probe and case Conforms to ASTM standard F2170-09 Page 4 / 2014-09-25 / MRU / Vaisala

Standard contents of the SHM40 kit 1. Pocket for documents and accessories 2. HM40 indicator with quick connection adapter (HM40SINDI) 3. HMP40S humidity and temperature probe (HMP40S) 4. Plastic tubes, 12 pcs (19266HM) 5. Rubber plugs, 12 pcs (233976) 6. Protective covers with lid, 3 pcs (19268HM) 7.&8. optional accessories for wet concrete, see next slide Page 5 / 2014-09-25 / MRU / Vaisala

Accessories for wet concrete Optional items not included with the standard kit: Long rubber plug for fresh concrete, 12 pcs (26530HM) Plastic flange for fresh concrete, 12 pcs (26529HM) X Preparing the plastic tube, plastic flange and long rubber plug for fresh concrete Plugged tube with flange in fresh concrete Page 6 / 2014-09-25 / MRU / Vaisala

Standard sellable items HM40S HM40 indicator with adapter and cable probe HMP40S RH&T probe HM40SINDI HM40 indicator with adapter (no probe included) 1 2 6 7 8 3 4 5 HM40S with standard case Three HMP40S probes HM40SINDI (no probe incl.) Page 7 / 2014-09-25 / MRU / Vaisala

HMP40S RH&T probe for structural moisture measurements 1. HMP110 probe 2. 30 cm cable 3. Integrated rubber plug 4. Quick connection adapter for HM40 4 1 2 3 Page 8 / 2014-09-25 / MRU / Vaisala

HM40SINDI Indicator and quick connection adapter 1. Quick connection adapter for HMP40S probe 2. Display 3. Right function button 4. Up arrow button 5. Power button 6. Left function button 7. Down arrow button 8. Menu button 6 7 8 1 2 3 4 5 The HM40 indicator is powered by two AA-size batteries. You can use the following battery types: Alkaline (IEC-LR6) Lithium (IEC-FR6) NiMH (IEC-HR6) Page 9 / 2014-09-25 / MRU / Vaisala

Indicator screen layout and controls 1. Alert indicator 2. Currently selected quantity 3. Battery indicator 4. Measurement display area 5. Currently selected view 6. Left function button: change view 7. Menu button: enter menu 8. Right function button Long press: tag point, short press: tag point and hold screen 9. Power button Long press: power on/off, short press: activate backlight 10. Arrow buttons: change quantity 3 4 5 6 7 1 2 10 8 9 Page 10 / 2014-09-25 / MRU / Vaisala

HM40S Quantities explained Quantity Symbol Unit(s) Description Relative humidity RH % Ratio of the partial pressure of water vapor in the air to the saturation vapor pressure of air at the current temperature. Dewpoint Td C F Temperature at which the water vapor in the air will condense into water at the current pressure. When the dewpoint is below 0 C, the HM40 outputs frostpoint (Tf) instead of dewpoint. Wet bulb temperature Tw C F The minimum temperature that can be reached by evaporative cooling in the current conditions. Absolute humidity a g/m3 gr/ft3 Mixing ratio x g/kg gr/lb Enthalpy h kj/kg btu/lb Temperature T C F Quantity of water in a cubic meter (or cubic foot) of air. Ratio of water vapor mass per kilogram (or pound) of dry air. Sum of the internal energy of a thermodynamic system. Temperature in Celsius or Fahrenheit scale. Page 11 / 2014-09-25 / MRU / Vaisala

Indicator views Graphic view 1. Current values 2. Vertical spacing of the grid 3. Graph maximum 4. Graph minimum 5. Time Numeric view Statistics view Page 12 / 2014-09-25 / MRU / Vaisala

Other indicator features Hold and tag function Calibration of the probe attached Settings: Graph duration Units metric, non-metric Language English, German, French, Finnish, Spanish, Swedish, Chinese, Russian, Japanese, Portuguese Time and date Pressure hpa, bar, atm, PSI Backlight, battery, navigation, rounding Page 13 / 2014-09-25 / MRU / Vaisala

The borehole method Hole ( 16 mm) to a suitable depth in the concrete structure After drilling, hole is cleaned and covered, and humidity in hole is allowed to equalize with humidity in the concrete. Equilibrium in ~3 days Hole must be sealed during equalization time. Plastic tube and rubber plug in the SHM40 kit should be used. Ideally, probe should be inside plastic tube during equalization. For reliable results, it is recommended to have several measurement points. Page 14 / 2014-09-25 / MRU / Vaisala

Recommended setup during borehole stabilization 1. Lid 2. Protective cover 3. Probe cable 4. Rubber plug 5. Probe 6. Plastic tube Page 15 / 2014-09-25 / MRU / Vaisala

Performing the measurement Connecting the HMP40S probe to the indicator quick connection adapter Performing the actual humidity measurement Page 16 / 2014-09-25 / MRU / Vaisala

Specifications (1/2) Relative humidity Measurement range 0... 100 %RH Accuracy (incl. non-linearity, hysteresis and repeatability) Temperature range 0... +40 C 0... 90 %RH ±1.5 %RH 90... 100 %RH ±2.5 %RH Temperature range -40 0 C, +40 +80 C 0... 90 %RH ±3.0 %RH 90... 100 %RH ±4.0 %RH Factory calibration uncertainty at +20 C Humidity sensor Stability ±1.5 %RH Vaisala HUMICAP 180R ±2%RH over 2 years Typical stabilization time in a borehole when the concrete and the probe are in the same temperature 30 min Temperature Measurement range -40 +80 C Accuracy over temperature range: 0 +40 C ±0.2 C -40 0 C, +40 +80 C ±0.4 C Temperature sensor Pt1000 RTD Class F0.1 IEC 60751 Page 17 / 2014-09-25 / MRU / Vaisala

Specifications (2/2) General Operating temperature range for probe -40 C...+80 C Probe weight with standard cable Probe housing material Probe filter and sensor protection Cable material Cable connector Probe housing classification 31 g Stainless steel Membrane filter with chrome coated ABS plastic Wire: PVC, Jacket: PU TRRS male 3.5 mm IP65 HM40 Indicator Operation temperature range for indicator -10...+60 C Storage temperature range -30...+70 C Weight Indicator with adapter and batteries SHM40 case with standard content Indicator materials Indicator adapter materials Housing classification Mechanical drop endurance Power-up time Batteries Operation time (Alkaline batteries) Calculated variables Menu languages (simplified), Russian, Japanese Display Electromagnetic compatibility (EMC) 240 g 3.7 kg PC/ABS blend, Acrylic display lens Nickel plated brass and plastic overmolding IP54 1.0 m without the probe < 3 s 2 x AA sized, 1.5V (LR6) Typical 100 hours (without backlight) Td, Tw, a, x, h English, German, French, Finnish, Spanish, Swedish, Chinese LCD (140 x 160 pixels) European Union directive EN61326-1 for portable equipment Page 18 / 2014-09-25 / MRU / Vaisala

300 ±10 184 71 HM40 Indicator and HMP40S Probe Dimensions 12 72 12 4.5 44 Page 19 / 2014-09-25 / MRU / Vaisala

Spare parts and Accessories Description HM40 indicator with adapter and cable probe for concrete moisture measurements Order Code HM40S HM40 indicator with adapter RH & T probe with cable for concrete moisture measurements HM40SINDI HMP40S Adapter for indicator and cable quick connector HM40SADAPTER Cable for HMP40S probe Long cable (2.7 m) for HMP40S probe HMP40SCABLE HMP40SCABLE2 Plastic tube set (12 pcs) 19266HM Rubber plug set (12 pcs) 233976 Weather-proof carrying case with SHM40 filling 233815 Protective cover with lid (3 pcs) Plastic flange set (12 pcs, for wet concrete) Long rubber plug set (12 pcs, for wet concrete) USB recharger for HM40 indicator batteries 19268HM 26529HM 26530HM 229249SP Page 20 / 2014-09-25 / MRU / Vaisala