CONTENTS. 1. Preface Features Technical Specifications Application of Dummy Plate Usage of Connector & Roller...

Similar documents
Price Computing Scale ER Series

Simple Weighing Scale. SW-1S / 1C Series OWNER S MANUAL 9002-SW

Cautions for Your Safety

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

UWE-1707 SERIES CONTENTS OPERATION MANUAL ELECTRONIC WEIGHING INDICATOR 1. SPECIFICATIONS 2. INSTALLATION

IGB Series. Operation Manual. Platform Scale. Kg/Lb Specification IMPORTANT

Installation Manual. 65 Interactive LED/LCD. Model: HILF65101 (64.56 )

Line Interactive 1000VA/1400VA/2000VA Uninterruptible Power System

CAUTIONS... 4 INTRODUCTION...

Universal AC Power Source + AC Power Analyzer

SUBWOOFER SYSTEM YST-MSW10

BBA-Series Precision Balances

FCS-30/60/150 kg (3 DIFFRENT SCALES) Shipping scale

NOTE. This is warning & caution mark. This is hazard alert mark. This is useful information mark

PRECAUTIONS...4 PREFACE...6 NAMES AND FUNCTIONS...6 INSTALLATIONS...8 OPERATIONS...11 ERROR MESSAGE...13 SPECIFICATIONS...13

BILL COUNTER OPERATION MANUAL PRODUCT #700012

DL Series NEWDOLBO OWNER S MANUAL. Simple Weighing Scale 9002-DL

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

Operation Manual WARNING. Be sure to read this Operation Manual before use. Universal Space Amusement Equipment Ltd.

S-2000 OWNER S MANUAL

GMC-206/215/230 Digital Desktop Weighing Scale Operation Manual

DOT MATRIX PRINTER SP6000 SERIES

JANOME DESKTOP ROBOT JR2000N Series. Operation Manual. <Setup> For Qualified Installer ONLY

MWP SERIES. High Precision

LED Accu Penta 9x12W RGBWAU

Instruction Manual for. Torbal AGZN Series Balances

YST-SW20 SUBWOOFER SYSTEM OWNER S MANUAL. Active Servo Technology

IDS-801 Series Compact Bench Counting Scale. User Manual

Table of Contents. Laboratory Balances. Instruction Manual - TORBAL AGC Series

CONTENTS. PRECAUTIONS Introduction Installation... 7

Important Information KX-NTV150. Communication IP Camera. IP Video Doorphone. Model No. Model No. KX-NTV160

Camera Control Box. Instruction Manual CCB-WD (1)

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

EHC-WF. User/Technical Manual. Contents subject to change without notice

THE BULLET. Bluetooth Speaker with NFC Technology. Instruction Manual

Instruction Manual for. Torbal AGCN Series Balances

Kilotech. KRS SWP Series. Counter-top weighing scale. NTEP (USA) and Measurement Canada approved.

User s Manual Model PBL100 Logic Probe IM E. 4th Edition

Technical Parameter... 4 Installation and Connection... 5

Table of Contents. 3-1 Specifications & Features Front Panel Display Keyboard. 3-3 Rear Panel. 3-4 Power Supply. 4.

JanusRAID SA-6692J Hardware User Manual

INSTRUCTION MANUAL DISTRIBUTION UNIT. Please read this manual thoroughly before use, and keep it handy for future reference.

Instruction Manual. 14 Portable DVD Player - BPDVD14

OCEAN WATERPROOF WEIGHING SCALE USER MANUAL

USB 2.0 SR. Extender over one CAT-5 Cable. User Manual EXT-USB2.0-SR. Version A1

7 Digital Photo Frame

The ultimate multi-purpose digital scale Ideal for letters, parcels and large boxes

EQUIPMENT OPERATION MANUAL

User Manual DUO BEAM/RG

POWER SUPPLY UNIT PSU-3

TWISTED PAIR DISTRIBUTOR KE 0108CH-DW. Instruction Manual. Thank you for your purchase of this product

Installation Manual. Model: HILU Ultra HD Interactive Flat Panel Display

EB300 Weighing Scale Operation Manual

Motorized Curtain Tracks Progress 50 Motor Set

Weighing Indicator USER S GUIDE. globalindustrial.com. globalindustrial.com. 11 Harbor Park Drive Port Washington, NY 11050

3700 SERIES USER MANUAL

USERS GUIDE MCX-STH. 3G SDI to HDMI Converter. Manual Number:

EPS Power Supply

Instruction Manual. 9 Dual Screen Portable DVD Player - BPDVD99

High Precision Quad Output DC Power Supply

NIR Moisture Analyzer KB-30

PNP415/417 POP 'N PLUG WITH CUSTOM TABLETOP SURFACE USER'S GUIDE

Users Manual STP-103II. Thermal Printer Rev

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

Robot Light V2. User Manual

When using the scale, the following safety precautions should always be followed:

PX Series Balances. Quick Start Guide. Please download the user manual from

Touch-controller_IM_03943A_1_Co_EN.indd 오후 3:06:00

TWP series. Weighing Indicator Service Manual

User Manual. Stoltzen SHSP14 HDMI Splitter 1x4. 4K HDMI Splitter 1x4. All Rights Reserved. Version: SHSP14_2016V2

User Manual. Waterproof Weighing Scale. ELW Plus / ESW Plus ELW Plus Wipower

Please refer to Page 3.

-auto Power Off- T1/T2/T1-T2

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

PW-II Service Manual PW-II SERVICE MANUAL

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

EQUIPMENT OPERATION MANUAL

TWP-W. Weighing Indicator Service Manual

COLOR VIDEO DOOR PHONE

DC-V3213XJ-4.3mm DC-V3213XJ-2.5mm

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only.

OWNER'S MANUAL. Model:PSV Amp SWITCHING DC POWER SUPPLY.

Instruction Manual MINI CALIBRATOR MC-20

MODEL PS-11 DIGITAL PORTION SCALE

HCC-CW-201A. CWDM Analyzer. Operation Guide

1. Introduction Page 2. Specifications Page Installation Page Key Functions Page Operations Page 6. Check Weighing Page 6

1. INTRODUCTION This manual contains installation, operation and maintenance instructions. Please read the manual completely before using the balance.

User Manual TL-FO-HD. 4K Optical Fiber Extender. All Rights Reserved. Version: TL-FO-HD_160628

M U L TI - SP ORT SCOREBOARD

Installation Manual INTELLIGENT SERVER. Model name: BMS-LSV6UL

PRECAUTIONS FOR USE. Be sure to use indoor wiring within the specified voltage requirements. For extension cord, use the specified rating or more.

! User Manual Rev. 1

User Manual VIDEO DOOR PHONE

USER S GUIDE. Weighing Indicator. globalindustrial.com. Use of RS232 Port Using Windows for the Printer Driver, Adjust Computer Settings as Follows:

Fujitsu Stylistic ST4000 Series TABLET DOCK USER S GUIDE

YJ Carat and Gold Scales

A120 A W/240W PA Mixer-Amplifier 70V/100V

S2 USER MANUAL. AL Manual 110ES WL S2 En 103

PS805 Thermal Receipt Printer. User Manual. Safety Notice: Main Features:

DF-780(B) Operation Guide

Transcription:

2

CONTENTS - RW-2601P Series Caution... 4 1. Introduction... 5 2. Features... 7 3. Technical Specifications... 7 4. Explanation of Frontal Aspect... 9 5. Test Mode...11 6. Set Mode... 14 7. Calibration Mode... 17 8. Error message and Trouble shooting... 21 - RW-P Series 1. Preface... 24 2. Features... 24 3. Technical Specifications... 25 4. Application of Dummy Plate...27 5. Usage of Connector & Roller... 28 3

Caution Safety Caution Make sure to comply with the safety cautions as they are designed to prevent dangers in advance by using the products safely and properly. Cautions are categorized into 2 types and the significances of Warning and Caution are as follows. Refers to situation that may result in high possibility of substantial danger including death or serious injuries if the directions are infringed. Refers to situation that may result in high possibility of injuries or material losses if the directions are infringed. 1. Never disassemble, repair or modify. Such will not only exempt the product from warrantee but also cause damages to the apparatus, electrocution or fire. 2. Do not damage, process or excessively pull, bend or twist the power supply cord. This may damage the power supply cord and may cause fire or electrocution. 3. Do not place combustible spray or fire in nearby location. 4. Do not water to external aspect of the product of use in humid location. This may cause insulation to be deteriorated, thereby causing risk of electrocution or fire, or occurrence of error in weighing. 5. Do not place at location exposed to direct sunlight or near hot objects such as stove. It may cause fire. 6. Make sure to insert the power supply plug fully in order to prevent the plug from becoming loose. If the contact is not stable, electrical spark may occur and cause fire. 4

1. Introduction Thank you for purchasing the CAS RW(2201P/2401P/2601P)_Series (hereinafter referred to as RW_Series) weighing indicator. We have designed this equipment with many advanced features, high quality construction, and user-friendly menu driven programming. We are confident that you will find the CAS RW_Series will meet all of your most demanding needs. CAS indicator is shaped firmly and delicately designed to coincide with the special requirements of several industrial fields and includes many functions and various external interfaces. Also, it contains help display functions to be used easily. Before using RW_Series, It is recommended to read this manual carefully and to apply the function application fully. Precautions Observe the following safety precautions : Warning When any damage or defect occurs, contact your CAS authorized dealer immediately for proper repair. Insert plug firmly to wall outlet to prevent electric shock. Avoid placing the scale near heather or in direct sunlight. Do not pull the plug by its cord when unplugging. Damaged cord could cause electric shock or fire. To prevent from fire occurring, Do not place or use the scale near flammable or corrosive gas. To reduce electric shock or incorrect reading, Do not spill water on the scale or place it in humid condition. 5

Attention For consistent and accurate reading, maintain periodical check by your CAS authorized dealer. Avoid sudden shock to the scale. Internal mechanism could by damaged. Attach the rubber pad to the bottom of the indicator. Elimination is possible. Place the scale on firm and temperature consistent environment. Keep the scale away from the electromagnetic generation devices. This may interfere with accurate reading. Our Dealers : CAS feels that each of its valued customers should get the best service available. Whether it s the initial installation of our product, maintenance/repair work, or simply answering questions about our products, CAS Corporation and all of its Authorized Dealers are highly trained to assist you with any need regarding CAS products. 6

2. Features Features Up to 6 axle(p/f) scales. Compact size & light weight Box type. Built in inner clock for date / time print. Built in printer. Built in Battery Charger & Large Capacity Battery. (6V/10A x 2 ea) 3. Technical Specification Overview 7

Dimension Specification Model Name RW- 2201P/2401P/2601P Operating Power Inner Battery Operation. (DC 6V) Power Source Display Type Display Designators RW- Printer Box AC 110/220 V, 50/60 Hz( For Battery Charger)) LCD 6 Digit(25mm) Stable, Zero, Kg/ lb Built In Printer Without Display. Accessory Box Cable AC Cord, Adaptor. Product Weight 9.2 kg 6.5 Kg 3.5 Kg 8

4. Front panel Description (1) Display lamp STABLE lamp : Turn on when the weight is stable. ZERO lamp : Turn on when the current weight is 0 kg(0 lb). GROSS/NET lamp : Turn on when the current weight is NET weight. lb/kg : Turn on when the weight unit is lb or kg. (2) Key Usage TARE Key : Current weight is memorized as TARE weight. If you press TARE key in unload condition, tare setting is automatically released. ZERO Key : Used to return the display to the center of ZERO when the platform is empty. GROSS/NET Key : Display gross and net weight by turn. kg/lb Key : Toggles between lb and kg units. (only USA Version) SUM Key : Used to print sum total weights. 9

PRINT Key : Used to print the current weight. TURCK No. Key : Used to input the number plate of vehicle which is used to weigh. Only you can input number within five digits. PRINT Key : Used to store current condition and exit in CALIBRATION, TEST, SET mode. P/F 1 Key : Used to display the weight which is connected to Platform 1. P/F 2 Key : Used to display the weight which is connected to Platform 2. P/F 3 Key : Used to display the weight which is connected to Platform 3. P/F 4 Key : Used to display the weight which is connected to Platform 4. P/F 5 Key : Used to display the weight which is connected to Platform 5. P/F 6 Key : Used to display the weight which is connected to Platform 6. (3) How to enter TEST mode Turn on the Power while pressing the key, and TEST mode starts. (4) How to enter SET mode Turn on the Power while pressing the key, and SET mode starts. (5) How to enter CAL mode Turn on the Power while pressing the key and press key, and CAL mode starts. 10

5. Test Mode (1) How to enter Press the "ON/OFF" key while pressing the key, and TEST menu starts. (2) Available keys Key : Change the set value. Used to increase the set value + 1. Key : Change the digit of the set value. Used to increase the set value 10. Key : Move to the next menu. (3) Test Menu(TEST 1 - TEST 5) Test 1 : Key Test Test 2 : LCD Display Test Test 3 : Load Cell Test and A/D conversion test Test 4 : Serial Interface / Printer Test(RS-232) TEST 1 FUNCTION : Key test Key Display Description TEST 1 condition. ENTER key : test 1 Press the key to be test and the Move to the next Key number No of key mode should be identify menu. ex)in case of Zero key with code of key. Other key : 1 Perform test. If you press Enter key, it will be moved to test 2. 11

< Key List > Key Code Number Key Code Number TEST 2 P/F 1 03 Tare 05 P/F 2 07 Gross/Net 09 P/F 3 11 kg/lb 13 P/F 4 15 Sum 02 P/F 5 04 Print 06 P/F 6 08 Truck No. 10 Zero 01 Enter 14 FUNCTION : LCD display test ENTER key : Move to the next menu. Other key : Perform test. Key Display Description test 2 8.8.8.8.8.8 TEST 2 condition. TEST 2 is automatically performed. After this test completing, it will be moved to test3 automatically. Ref 1. Program is automatically shifted to test 3 after completing Test 2. TEST 3 FUNCTION : Load cell test and A/D conversion Key Display Description ENTER key : TEST 3 condition test 3 Move to the next Digital value of menu. current weight in PF under actual condition. Other key : which you set. Perform test. ex) 1 5 0 0 Display digital value of current weight. This value means converted digital value If you press Enter key, it will be moved to test 4. Ref 1. A/D converter test is automatically completed by displaying converted digital value of current weight. Ref 2. L/C test is also completed by loading the weight on the platform. Check whether digital value is changing. If the digital value is fixed or zero is displayed, please check the connection of the load cell. 12

TEST 4 FUNCTION : Serial Interface / Printer test ENTER key : Exit from the Test Mode Other key : Perform test. Key Display Description test 4 - - - - GOOD 2601P Test 4 condition Press Enter key. It will be moved to Normal Mode after test mode. Ref 1. Perform test only when the printer connection are installed. Ref 2. GOOD message is displayed if the printer connection and specification is done correctly. If or not, ERR 6 message is displayed. Ref 3. The test output format of printer is as the follows. TEST OK If you press the Enter key, it will be returned to NORMAL MODE. However, only when it is connected with printer, this test can be performed. * PRINTER FORM * 2010. 8. 25 10:15:20 WEIGHT 1 1200 kg WEIGHT 2 1200 kg WEIGHT 3 1100 kg WEIGHT 4 1100 kg ---------------------------- TOTAL 4600 kg 13

6. Set Mode (1) How to enter Press the "ON/OFF" key while pressing the key, and TEST menu starts. (2) Available keys Key : Change the set value. Used to increase the set value + 1. Key : Change the digit of the set value. Used to increase the set value 10. Key : Move to the next menu. (3) Set Menu(F01 - F14) F01 : Select Primary Base Unit (kg/lb)-u.s.a version. F02 : Designation of Serial Port Usage(RS-232C). F03 : Automatic Zero Tracking Function F04 : Digital Filter Function. F13 : Quantity of Scales (P/F, Axle Scale) F14 : Select Option Clock. 14

Select Primary Base-unit F01 0 Primary unit is kg 1 Primary unit is lb Select Primary Base-unit F02 0 Not used 1 Connection with Serial printer Automatic Zero Tracking F03 1 ~ 9 0 Not used 1 : 0.5 division ~ 9 : 4.5 division Auto zero tracking will automatically bring the displayed back to 0 when there are small deviations. Digital Filter Function 1 F04 ~ 9 1 : Less Vibration ~ 9 : Much Vibration Adjust set value according to the condition. Select the Back-Light Usage F08 0 Manual Back Light 1 Automatic Back Light Quantity of Scales 1 One scale 2 Two scales F13 3 Three scales 4 Four scales 5 Five scales 6 Six scales 15

Select Option Clock F14 0 Not used 1 Used Quantity of Scales : Increase of no. : Shift of digit. Enter : Store and move to the next menu. Display C1 10 YEAR : 10 C2 08 MONTH : 08 C3 25 DAY : 15 C4 13 HOUR : 13 C5 10 MINUTE : 10 C6 01 SECOND : 01 Description 16

7. Calibration Mode (1) How to enter Turn on the Power while pressing the key, and then press key, and press Enter key as soon as you selecting the number of platform. If you don't set the number of platform, it will automatically be moved to Normal Mode. F13 should be set before entering to CAL mode. (2) Available keys Key : Change the set value. Used to increase the set value + 1. Key : Change the digit of the set value. Used to increase the set value 10. Key : Move to the next menu. (3) Calibration Menu(CAL 1 - CAL 5) CAL 1 : Maximum Capacity Setting CAL 2 : Minimum Division Setting CAL 3 : Setting Weight CAL 4 : Zero Calibration CAL 5 : Span Calibration 17

CAL 1 FUNCTION : Maximum Capacity Set RANGE 1 ~ 99,999 kg/lb Key Display Description : Increase of no. : Shift of digit. Enter : Store and move to the next menu. ti. 03 CAL 1 10000 Maximum Capacity Value Program version CAL 1 condition 10000 kg / lb Ref 1. The maximum capacity means the maximum weight that scale can measure. Ref 2. Do not input the resolution, there is no need to input the resolution which is Automatically calculated. Ref 3. If you press Enter key, it will be moved to CAL 2. CAL 2 FUNCTION : Minimum Division Set RANGE 0.0005 ~ 100 kg/lb Key Display Description CAL 2 condition : Input the next division. Enter : Store and move to the next menu. CAL 2 0.01 Minimum Division Value 0.01 kg / lb Ref 1. The minimum division means the value of one division. Ref 2. External resolution is obtained by division the min. division by the maximum capacity. Set the resolution to be within 1/10,000. Ref 3. If you press Enter key, it will be moved to CAL 3. 18

CAL 3 FUNCTION : Setting Weight In Span RANGE 1 ~ 99,999 kg/lb : Increase of no. : Shift of digit. Key Display Description Enter : Store and move to the next menu. CAL 3 Maximum Capacity of CAL 1 (ex : 10000) Setting weight (ex : 100) CAL 3 condition 10000 kg / lb 100 kg / lb Ref 1. The weight shall be within the range of 1 % ~ 100 % of maximum weight. Ref 2. If the Setting Weight is under the 1% of the Maximum Capacity, Error message ("ERR 22") will occur. Ref 3. If the Setting Weight over the Maximum Capacity, Error message ("ERR 23") will occur. Ref 4. If you press Enter key, it will be moved to CAL 3. CAL 4 FUNCTION : Zero Calibration Function Key Display Description Enter : Zero Calibration and move to the next menu. CAL 4 UnLOAd A/D value - - - - GOOd CAL 4 condition Unload the tray and press Enter key Display A/D Value. Press Enter Key. Under zero calibration Zero Calibration is completed. The program moves into Span Calibration automatically. Ref 1. If Zero calibration is done without any error, GOOD message is displayed and program automatically moves to CAL 5. Ref 2. If the zero value is too high, ERROR message (ERR 26) is displayed. Ref 3. Zero calibration can be done independently. If you press ZERO key instead of Enter key, zero calibration will perform. After that, it will be moved to SAVE & EXIT mode. 19

CAL 5 FUNCTION : Span Calibration Function Key Display Description Enter : Span calibration and move to the next menu. CAL 5 LOAd Setting weight - - - - GOOd Save CAL 5 condition Unload the weight which was set in CAL 3. It is displayed the setting weight. And then, press Enter key. Under span calibration. Span calibration is completed. Check whether the displayed weight Is same with setting weight. Calibration is completed. Under this condition, release the load. Press the ENTER key to save the value. Ref 1. If Span calibration is done without any error, GOOD message is displayed The weight of setting weight is displayed on Display screen. Check the weight. Ref 2. If the span is low, Error message (ERR 24) is displayed. Calibrate with lower resolution. Ref 3. After setting the exact value, remove the setting weight and Press the "ENTER" key to save the value. Ref 4. In case of setting F13, it can be moved to another Platform. If all of platform is finished, it will be moved to Normal Mode. 20

8. Error message and Trouble shooting Err 02 Reason Load cell connection failure or error in A/D conversion part. Trouble shooting Check the load cell connector to see if the polarity of signal is reversed. Err 06 Reason Error in printer connection Trouble shooting Check with printer connector If there is no problem with printer connector, please request A/S to head office. Err 13 Reason The zero range deviates from the set range. Trouble shooting Confirm that there is nothing on the weighing platform. If there is nothing exist, do calibration in CAL mode. Over Reason The weight on platform is too heavy to be measured. Trouble shooting Do not load cell item exceeds the maximum tolerance. If the load cell is damaged, the load cell should be replaced. Err 21 Reason The resolution is set to be exceeded the limit 1/10,000. Trouble shooting 21

Lower the resolution. The resolution = allowed weight/one division Modify the allowed weight in CAL1 or modify the division in CAL2 so that the resolution should be below 1/10,000. Err 22 Reason The weight for span calibration is set to be lower than 10 % of the maximum capacity of the scale. Trouble shooting Set the weight for span calibration in CAL3 to be more than 10% of the maximum capacity. Err 23 Reason The weight for span calibration is set to be exceeded 100 % of the maximum capacity of the scale. Trouble shooting Set the weight for span calibration to be within the maximum capacity of the scale in CAL 1. Err 24 Reason The load cell output is too small at SPAN calibration. Trouble shooting Setting of current resolution is not possible due to the error in load cell. Proceed calibration again with less resolution. Load cell Sense Voltage for 5V Excitation Voltage Recommended Resolution 2 mv 1/1,000 4 mv 1/2,000 10 mv 1/5,000 22

Err 25 Reason The load cell output is too large at SPAN calibration. Trouble shooting Setting of current resolution is not possible due to the error in load cell. Proceed calibration again with less resolution. Err 26 Reason The load cell output is too large at ZERO calibration. Trouble shooting Check whether the platform empty. Proceed calibration again after checking i 23

max 1 RW-P Series 1. PREFACE We greatly appreciate your purchase of CAS Road Weigher, which is used for displaying the value of weight loaded on each shaft of vehicle. These goods have hold excellent performance and splendid properties through strike tests as well as devoting ourselves under severe quality management. Before using road Weigher, It is recommended to read this manual carefully and to apply the function application fully. CAUTIONS - Avoid sudden temperature change. - Keep it in dry place. - Use this product the place where the ground is flatness and hardness - Don t use this product when it is raining - Keep out of muddy area and sandy area - When the sands get in the gap between loadcell and foot, remove to use air cleaner max 2mm max 2mm SAND AREA, CLAY AREA (To use after cleaning) 2. FEATURE Slim(height 40mm) type built in high accuracy load cell 24

3.TECHNICAL SPECIFICATION OVERVIEW DIMENSION 25

PRODUCT SPECIFICATION MODEL RW-01P RW-05P RW-10P RW-15P 1,000 kg 5,000 kg 10,000 kg 15,000 kg Max (2,000lb) (10,000lb) (20,000lb) (30,000lb) 10kg Division - - - (20lb) Accuracy 0.1% Size LxW 500x400(19.7 x15.7 ) 900x500(35.4 x19.7 ) H 40(1.6 ) WEIGHT 15.8kg 30.2kg OPTION 1) Dummy Plate - Material : Rubber (NBR) - Reference : page 33 26

4. Application of Dummy Plate Clossification Q TY ACCURACY First Weighing 2 nd Weighing 3 rd Weighing 4 rd Weighing 2 A X L E 3 A X L E 4 A X L E PLATE: 2EA PLATE: 4EA PLATE: 2EA DUMMY: 12EA PLATE: 4EA PLATE: 6EA PLATE: 2EA DUMMY: 12EA PLATE: 4EA ±1~3% ±0.1% ±1~3% ±1~2% ±0.1% ±1~2% ±0.5% 5 A X L PLATE: 2EA DUMMY: 12EA E PLATE: 6EA ±1~3% ±0.5% (The ground condition : flatness, hardness, zero declination of close axis) * Application data of dummy plate is possible to be changed according to the ground condition and vehicle condition(old vehicle occasion) 27

5. Usage of Connector & Roller Connection of connector Moving roller (RW-10P,15P) 28

MEMO 29

MEMO 30

31