QGV Units with G-120 Drives IMMEDIATE ACTION REQUIRED IMPORTANT PRODUCT SAFETY NOTICE

Similar documents
Installation Instructions

QuincyHQ.com. Distributor Reference Guide

ServView 17S KVM Switch

SIRIUS CAPACITOR MODULE User Manual. Model number: A-1.7C-M-SD-G Version 1.0; Release Date: April 2018

UT Martin Environmental Health & Safety Safety Procedure

User Manual. 1U LCD Keyboard Drawer. KwikDraw - A Series. Manual. IT and Instrumentation for industry. - With KVM options - 15", 17, 19 screen size

Application Note (Revision NEW) Original Instructions EGCP-3 LS Using an EGCP-3 in a Single-Phase Zig Zag Generator Application

Operating instructions. Switching amplifier DN0210 DN / / 2015

Techno SERVO GCODE INTERFACE

Installation, Operation and Maintenance Manual

Installation Instructions

Operating Instructions

Application Note (Revision NEW) Original Instructions. EGCP-2 Differences

Putting Allen Bradley SCL-150 Controllers Back in the Run Mode

Chapter 2: Disassembly

SKIVING MACHINE MAINTENANCE & INSTRUCTIONS MANUAL ASSK2. Allswage UK. Roebuck Street, West Bromwich, B70 6RB

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

Toughbook. CF-C1 MK1 refurbished. Table of Contents:

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Operating instructions. Speed monitor D / / 2014

Model HM-535 Power Supply Installation and Service Instructions

SE Engineering, PC strives to be a leader in the power system engineering field by providing our customers with the highest level of quality,

ATV Single Gang Disc Harrow OWNER S MANUAL

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

ATV Single Row Disc Harrow OWNER S MANUAL

EGCP-3 LS Revision R Software Revision M. Application Note (Revision NEW, 6/2009) Original Instructions

Job Sheet 5 Motor Drives

Model 2380 Rack-Mount Kit

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

Install Motor Controller User Manual

User Guide. μvrc Robotic Control System. μvrc Robotic Control System. Part No. V

Input Power Selector Switch. Product Manual (Revision NEW) Original Instructions for use with Generator Set Control Assembly

USER MANUAL VIBRATION CONTROL RMA-POWER-BOX 107/230

39 SLEEVE HITCH DISC OWNER S MANUAL

Made In America 2017 TigerStop, LLC. Tablet Package. Installation Guide. February 2017 Mk1

User Manual RKD-KVM-20 / RKDS-KVM-20. WRKD-KVM-19 / WRKDS-KVM-19 Series. Series

HV-CS kv Edge Mount Triaxial Jack

High Pressure E/P Regulator. ITVH Series

MFA-0801 & MFA-1201 D-M-E Smart Series Low Voltage Temperature Control System. User s Manual. D-M-E Company

MANUAL Functional Safety

ICON SERIES IDRIVE. Intelligent Constant Pressure. Water Supply Controller User Manual. idrive

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Operating manual. Diagnostic adapter VAS Operating manual Diagnostic adapter VAS Client documentation Revision: 00 Version: 05/2018

INSTRUCTION MANUAL IM253 R0. AquaStart COMBINATION SOFT STARTERS START-UP MANUAL

SATA II HDD Canister KISS DA 435 Quick Reference Guide

Notebook Tour User Guide

FUSION 400. User s Guide. 4-Bay Serial ATA Hot-Swap Drive Enclosure. For Windows

TECH-system Type 322 BASIC

Model 2380 Rack-Mount Kit

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

ELECTRICAL SUPPLY TROUBLESHOOTING QUICK GUIDE SAFETY PRECAUTIONS

COOPER POWER SERIES. Input/Output (I/O) module installation instructions. Voltage Regulators MN225067EN

IO-INTERFACE. Procon. INSTALLATION MANUAL Version 1.01 MITSUBISHI ELECTRIC FOR INSTALLERS

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Lockout/Tagout Training:

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

Series 370 S SoftwSystem are Qui Switch/Mult ck Start G imeter uide Quick Start Guide

TABLE OF CONTENTS PRODUCT INFORMATION... 3 SPECIFICATIONS... 4 IMPORTANT SAFETY INSTRUCTIONS... 5

Vista SD Portable Remote Control Pendant

Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide

GN 4170 headset telephone Hands-free ease with sleek, space-saving phone

RAINPROOF* COLOR CAMERA SECURITY SYSTEM

USERS GUIDE ASP-18H-4K. HDMI 4K2K 1x8 Splitter with EDID Management. Manual Number:

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

Great Western Painting Assured Equipment Grounding Conductor Program OR Ground Fault Circuit Interrupter (GFCI)

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

Line Interactive 1000VA/1400VA/2000VA Uninterruptible Power System

EMS Electrical Management System

Robot Light V2. User Manual

INSTALLATION INSTRUCTIONS 07/2018

If you have questions about your KCD-2000 and its operation, please contact technical support at

HBO 100 Microscope Illuminating System

PLI Mbps Powerline Adapter User Manual

dedicated KVM switch and rackmount screen technology User Manual CV-1201D DVI-D KVM Designed and manufactured by Austin Hughes

User Manual - KVM Rear Kit Version

Manual Control Unit GFC 32

Temperature Guard Models VM500-3 & VM500-3HT. Home Guard Model VM Operating Manual and Installation Instructions

FIBARO SINGLE SWITCH

Elements of a Lockout/Tagout Program

BPN-SAS-F424-A6 Backplane USER'S GUIDE

Please read and retain these instructions for future reference v002: 14/03/17. Cradle, Charger, Instruction manual, Lithium-ion Battery 3.7 V d.c.

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A

Operating instructions IO-Link master CabinetLine AL19xx

Temperature Guard Models VM500-3 & VM500-3HT. Home Guard Model VM Operating Manual and Installation Instructions

MAXIMA+ Series Rotary Level Indicator

COOPER POWER SERIES. 600 A U-OP visible break connector system operation instructions. Deadbreak Apparatus Connectors MN650022EN

Model 7705 Control Module

Teslights Hybrid Lighting Controls B-PLC Solution UVAX Protocol Head End CA Technical Manual, T0115 June 2015

Features and Benefits of XeteX Controls. Other Unit Control Functions. Energy Recovery Functions

Owner s Instruction Manual

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

Electrician. Skilled Migration Assessment Services / Trades Recognition Services

4 Port USB Power Hub. Model: JH-800 USER MANUAL

Installation and Wiring

Bosch Smart Home. Plug Instruction Manual

MAXIMA + Series ROTARY LEVEL CONTROL

E8431 First Edition Model: T00CP

THECHARGEHUB.COM. User Manual. For Square & Round Models

Troubleshooting the Digisolver for Allen Bradley SLC-500 Programmable Logic Controllers

Transcription:

Service Alert Communications To: All Quincy Distributors From: Quincy Compressor Subject: Service Alert #389 Date: 02/01/2013 QGV Units with G-120 Drives IMMEDIATE ACTION REQUIRED IMPORTANT PRODUCT SAFETY NOTICE We are writing to inform you of an increased risk of fire occurring in your Quincy Compressor (variable speed units) that require a mandatory safety upgrade to be performed on your machine which features the Siemens G-120 variable frequency drive (VFD) utilizing the Siemens CU240S or CU240E Control Units (CU). Quincy has learned that these models originally shipped with a Control Unit setting which might permit the VFD to continue to energize the drive motor if the control circuit loses power. This quality issue represents a potential safety issue, as there is an increased risk of fire or potential damage to the compressor itself or its surroundings, which has prompted Quincy Compressor to issue this memo. General Information Two upgrade options are acceptable, depending on the end-users use of the machine. Option 1: Suitable for Customers NOT interested in using Networking functionality. Upgrade the PLC code to version 7.77 HMI code should be at version7.22. Note: Some models will already be at 7.22. In the event the QGV has this version of code, motor re-commissioning may not be required. In the event the HMI does not have version 7.22, recommissioning of the drive will be mandatory, which also requires the main drive motor to be off and fully cool. Upgrading the PLC code will not automatically set Parameter 2014 as described below unless the motor is recommissioned. The parameter can be set with the keypad. QGV Networking will not be included in PLC code 7.77 Option 2: Suitable for Customers who DO utilize the QGV Networking Functionality. No PLC or HMI code upgrade is required. The servicing distributor will use a keypad to manually change Parameter 2014 to be active within the VFD. (instructions shown below) Contact Quincy Compressor that you are utilizing the networking option. Quincy Compressor will supply an updated code version when completed.

If the program is not updated, the parameter will need to be reset if a motor recommission is performed in the future. Each distributor should immediately contact all QGV customers whose machines require the upgrade, and schedule a time to perform this upgrade. This is a mandatory upgrade: 100% compliance is required. For each Serial Number on record for which this change is required, Quincy Compressor will require a photograph to verify the change to the VFD parameters. When filing the warranty claim, Quincy Compressor will allow (1) hour labor plus travel and mileage for performing the upgrade. Multiple units at the same location must be completed on the same trip. Option 2 - Drive setting update: This is a drive setting update for Siemens G120 Drives that use the CU240S or CU240E control units.

This setting update will activate a communications monitor in the control unit. With this setting activated the control unit will shut down the drive with a fault F0072 if communications is lost with the PLC. Activate this setting as follows: Stop the compressor by pressing the STOP button on the touch screen. (Not the E-Stop). After the compressor stops proceed as follows. Step 1. Using the light blue keypad, attach it to the control unit on the drive. If you don t see r0000, then press the P key until you see this. Step 2. With r0000 shown in the keypad display, press the UP Arrow Key until the display shows P0003

Step 3. Press the P key and verify that a 3 is displayed. If a 3 is not displayed then use the arrow keys to set the display to a 3. and then press the P key. Press the P key and you will see P0003

Step 4. With P0003 shown in the keypad display, press and hold the UP Arrow Key until the display shows P2014. Step 5. Now press the P key and you will see in000 displayed.

Step 6. Press the P key again and you will see 0 displayed.

Step 7. Now this is very important. Press the down arrow key 1 time and you will see 65535 displayed. Step 8. Now hold the down arrow key until you see 65000 displayed. Step 9. Press the P key and you will see P2014 displayed.

Step 10. Press the Down Arrow key until you se P0971 displayed. Step 11. Press the P key and you will see a 0 displayed.

Step 12. Press the Up Arrow one time to set this to a 1. Step 13. Press the P key and you will see a busy message blinking in the display.

Step 14. Wait until the P0971 is displayed. You can now remove the keypad and run the compressor as normal. If you did not follow this procedure you will see a F0072 displayed.

If you see this screen then press the P key until you see an r0000 displayed and start this setting process over from step 1. The attached form must be filled out, scanned and e-mailed to Quincy Compressor at rotaryservice@ or mail to the address listed on the form. Quincy Compressor strongly advises each distributor to notify your customers of this issue as there is an increased risk of fire and/or catastrophic damage to the compressor and facility. Quincy Compressors emphasizes product quality, and values its association with our customer s productivity and safety. We appreciate your efforts to assist us in this matter and we regret any inconvenience this may have caused you. We trust that you appreciate our ambitions to keep a high level of product safety and quality. We wish to thank you for your cooperation, and our hope is that you recognize our commitment to you, our valued customers, and to your business. Application All QGV units utilizing the Siemens G-120 drive. This does not apply to any units shipped from the Bay Minette, AL plant on September 14, 2012 or after. Required Parts Option 1 PLC chip and keypad. (One set supplied to each selling distributor) Option 2 Keypad (One supplied with PLC chip)

Safety Precautions The operator must employ safe working practices and observe all related local work safety requirements and regulations. Maintenance must only be performed by authorized, trained and specialized personnel. Before maintenance, repair work, adjustment or any other non-routine checks, stop the compressor, switch off the voltage, press the emergency button and depressurize the compressor. In addition, the power insolating switch must be opened and locked. (Lockout/Tagout procedures to be followed) Use only the correct tools for maintenance and repair work. All maintenance work shall only be undertaken when the machine has cooled down. A warning sign bearing a legend such as Work in progress; do not start shall be attached to the starting equipment. Persons switching on remotely controlled machines shall take adequate precautions to ensure that there is no one checking or working on the machine. To this end, a suitable notice shall be affixed to the remote start equipment. Close the compressor air outlet valve before connecting or disconnecting a pipe. Before removing any pressurized component, effectively isolate the machine from all sources of pressure and relieve the entire system of pressure. Scrupulously observe cleanliness during maintenance and repair. Keep dirt away by covering the parts and exposed openings with a clean cloth, paper or tape. Make sure that no tools, loose parts or rags are left in or on the machine. All regulating and safety devices shall be maintained with due care to ensure that they function properly. They may not be put out of action. Always wear the following personal protective equipment: Work clothing, safety shoes, safety goggles, ear protection and safety gloves when there is a cutting risk or a risk for a heat injury.

Service Alert #389 QGV G-120 Program Update Form Fill out form, scan and e-mail to rotaryservice@ or mail to: Quincy Compressor Service Department 701 North Dobson Ave Bay Minette, AL 36507 Distributor Name: Customer Name: Customer Address: Customer Contact Name: Customer Phone Number: Customer E-Mail Address: I verify that (unit serial number), model was serviced on (date) updating the drive program with updated chips or by using the keypad. Print Name: Signature: ** This form must be completely filled out to validate that all units shipped from Quincy Compressor were upgraded with the new program. A separate form must be completed for each unit.