User Operation Manual

Similar documents
Co-Lase Users Guide. DM00001 Rev A (DCN 031) These instructions are protected by copyright. All rights reserved.

Renishaw invia Raman Microscope (April 2006)

Standard Operating Procedure for the Horiba FluroMax-4

ASI Photoport TIRF Injector Instruction Manual

User s Guide to the LMD Laser Micro-dissection. System

Indiana Center for Biological Microscopy. BioRad MRC 1024 MP Confocal & Multi-Photon Microscope

User Manual. pe-100 fiber. DOC-014 Iss 3 1

Mercury Manual No. IM-M1000 Rev G

The Anfatec Level AFM a short description. Atomic Force Microscopy - approved devices for affordable prices

TEL-218DRV TEL-X-Driver

Manual Infrared viewers ABRIS M series M1300 M1700 M2000

FastGene FAS-Nano. Catalogue Number GP06-LED

Title: Heidelberg DWL66+ Semiconductor & Microsystems Fabrication Laboratory Revision: B Rev Date: 05/03/2017

Raman Spectrometer Installation Manual

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Luminex Prima

1500V - Vacuum Rated

Microscopic Imaging Research Station (MIRS) Assembly Guide. Version 1.0.0

LSM 5 MP, LSM 510 and LSM 510 META Laser Scanning Microscopes

PH 481/581 Physical Optics Winter 2018

Technical Specifications for High speed PIV and High speed PIV-PLIF system

BPL SERIES INSTALLATION INSTRUCTIONS THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.

RING LIGHT. ON = Light Rest (LED inactive) OFF = LED/Light Ready Green Indicator LED

UHP-T-LED User Manual

Matlab OTKB GUI Manual:

DV2. Alignment Procedure. Install DV2 on Microscope NOTE: PLEASE READ THE ENTIRE PROCEDURE BEFORE YOU BEGIN ALIGNMENT OF THE DV2. Alignment Procedure

Prism Starter Guide 1.0 Hoskins Lab Last Modified 03/14/2017 Chris DeCiantis

ABM's High Resolution Mask Aligner Features:

Optical Trapping in the Teaching Lab

Olympus DeltaVision Microscope Start-Up and Shut-Down Instructions.

` EVG 620 MASK ALIGNMENT SYSTEM Bay 1 STANDARD OPERATING PROCEDURE

1. Learn about LabView software and its different components

Techno SERVO GCODE INTERFACE

Blue Weapon Laser. User manual UK. Version 1.0

BD Influx Standard Operation Protocol - Basic Operation

AUTOMATIC MICRO-HARDNESS TESTER ISOSCAN HV1 OD

Confocal Microscope Imaging of Single-Emitter Fluorescence and Hanbury Brown & Twiss Setup for Photon Antibunching. Edward Pei

Operating Procedure for Horiba Raman Microscope

WARNING HAZARDOUS VOLTAGES

Led Illuminator and Light Stimulator. Model # LSD-1. Ver

Manual. Infrared cameras. Contour M

Removal and Installation8

User Manual. Confocal System

The Nureva Span ideation system. Installation guide. Single panoramic system

Widefield High Content Screening System User Guide

Contents. - i - Ver.:2

RAMM Microscope Configuration Guide

User Manual. Trinocular Stereo Microscope

POE. The majority of PSE equipment requires a detection resistance of 24.9KΩ to establish a PoE link. Some models of PSE equipment require12.5kω.

Nonlinear optics and two photon microscopy. Table of contents. Sam Whiteley and Seth Parker PHYS 173/BGGN 266 July 13, 2014

English. Quick Guide

Mk II 3DR MULTI-LINE LASER INSTRUCTION MANUAL

Be sure to always check the camera is properly functioning, is properly positioned and securely mounted.

Independent Resolution Test of

Olympus IX-70 Imaging Protocol

CVI SPECTRAL PRODUCTS. 111 Highland Drive Putnam CT, (860) SM32Pro

User Manual. Trinocular Stereo Microscope

STEP-BY-STEP INSTRUCTIONS FOR BUILDING A FLUORESCENCE MICROSCOPE. TECHSPEC Optical Cage System

Confocal Microscopy Imaging of Single Emitter Fluorescence and Hanbury Brown, and Twiss Setup for Photon Antibunching. Abstract

Leica TCS SP8 X Confocal Microscope and Leica Application Suite X software DRAFT VERSION Room B123b

Manual Infrared cameras Contour IR Digital

Zeiss AxioImager.Z2 Fluorescence Protocol

NDD FLIM Systems for Leica SP2 MP and SP5 MP Multiphoton Microscopes

Olympus IX-70 Imaging Protocol

Series 3700 Screw Terminal Assemblies Installation Instructions

9500 and 9600 I/O Card Installation Instructions

Optical Ptychography Imaging

Multi-Photon Training

AUTOMATIC HARDNESS TESTER ISOSCAN HV50 AC

phoenix Upgrade Packages for SLM Model 4800/48000/8000/8100 Spectrofluorometers

LEXT 3D Measuring LASER Microscope

HD Video Recorder Manual

Video Microscope Table MEA-VMT Manual

UNIVERSITY OF CENTRAL FLORIDA DEPARTMENT OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCE HEC 406 NANO/MEMS LABORATORY

RING LIGHT. LED Strobe Indicator ON = Light Active Green Indicator LED

High speed laser. altimeter for. accurate mapping. and obstacle. detection. Features: SF30 Accelerated laser rangefinder Product manual

CATALOGUE INFRARED VIEWERS AND CAMERAS 2017

Intel NUC Kit NUC5i3MYHE & NUC5i5MYHE User Guide. Intel NUC Kit NUC5i3MYHE Intel NUC Kit NUC5i5MYHE User Guide

Lumascope Startup Guide -- Lumascope 720

SF30 SF30. The SF30 is a high speed, light weight laser rangefinder for mapping and obstacle detection by robotic vehicles such as UAVs.

NUREVA SPAN SYSTEM INSTALLATION GUIDE

Diagnostic Troubleshooting Software

CONTENTS PRODUCT FEATURES... EG-2 SAFETY PRECAUTIONS... EG-2 PARTS DESCRIPTION... EG-3 INSTALLATION AND ADJUSTMENT... EG-4 SPECIFICATIONS...

Intel NUC Kit DC53427HYE User Guide. Intel NUC Kit DC53427HYE

Spectrum Laser. User manual UK. Version 1.0

LENS ATTACHMENT KIT INSTALLATION GUIDE

Building Your Own 2-Photon Microscope: Challenges, Advantages and Limitations

Intel NUC Kit NUC6CAYS User Guide

panasonic.net/id/pidsx/global CCD The sensor can be used for various applications with its binary data output with four different sensing modes.

Lyte-MV Digital Userguide Red & IR Versions

FIRST, A WORD ON SAFETY

INSTALLATION MANUAL. ST-BTWD650IR2812 B or W Weatherproof Day/Night Infrared Color Camera

User Guide. Intel NUC 8 Business, a Mini PC with Windows 10 NUC8i7HNKQC. Intel NUC 8 Enthusiast, a Mini PC with Windows 10 NUC8i7HVKVA

Back Illuminated Scientific CMOS

Series 1780 dynamometer and thrust stand datasheet

DBR Laser Module. Vescent Photonics, Inc E. 41 st Ave Denver, CO Phone: (303) Fax: (303)

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

Swift SM100 Series Stereo Microscope

Lightsheet Z.1. Light Sheet Fluorescence Microscopy by Carl Zeiss. Fabrice Schmitt, Sales Manager Carl ZEISS France

TN425: A study of fluorescence standards confirms that OptiGrid confocal images are suitable for quantitative microscopy

TissueFAXS SL Confocal high throughput configuration (actual appearance of the product may differ)

Transcription:

User Operation Manual Manual Version: 1.3 For Single Cell Bioanalyzer (SCB-402) Doc# 102-SCB-402-1.3

Table of Contents 1. General Information... 1 1.1 How to Use This Manual... 1 1.2 Operation Safety... 1 1.3 Product Overview... 2 1.4 Product Functions... 2 1.5 Implementation Constraints... 2 2. Basics of SCB-402... 3 2.1 Hardware Interfaces... 3 2.2 Module Description... 4 2.3 Optical Features... 5 2.4 Software Overview... 6 3. Experiment Tutorials... 8 3.1 Automated Test Run... 9 3.2 Microscope Scale-bar Test... 10 3.3 Fluorescent Bead Test... 10 4. Instrumental Maintenance... 11 4.1 Changing Chips... 11 4.2 PMT Calibration... 12 4.3 General Troubleshooting... 14

1 1. General Information 1.1 How to Use This Manual This manual aims to provide users with overall understanding of SCB-402 regarding its functions, operations and maintenance. Section 1 contains general descriptions of the system, defining the operation requirements and capabilities for SCB-402. Section 2 describes the overall system and various modules of SCB-402. Hardware, optics and software operations are discussed in detail. Section 3 provides step-by-step tutorials on the basic tests that users should encounter when operating SCB-402. Section 4 lists some common troubleshooting procedures. 1.2 Operation Safety The points below are intended to enhance your safety awareness and to draw your attention to risks which you, the operator, can prevent. While the instrument is designed and tested to be safe, proper handling is also critical. The operators should be first trained in basic laboratory protocols and they should be familiar with the possible hazards before operating this instrument. All instrument modifications should be performed only by qualified personnel of ZellChip. Equipment damage, personal injury or even death may result if this equipment is operated, altered or maintained by untrained personnel or in an irresponsible or improper manner.

2 1.3 Product Overview SCB-402 is essentially an inverted fluorescence microscope. Excitation wavelength of the incident light is selected by an excitation filter to irradiate the fluorescent molecules to be measured. When a laser is used as an excitation source, the excitation filter is not necessary. Emission wavelength of the fluorescent light is selected by an emission filter to measure the molecules. 1.4 Product Functions SCB-402 provides optical bright-field vision or imaging and fluorescent measurement to be conducted simultaneously on a cell or particle. A particle such as a fluorescent polymeric bead in a microfluidic biochip (e.g SCC-001) may be optically viewed and observed while fluorescent measurement of the embedded fluorescent dye in the particle can be monitored. In the case of a biological particle such as a cancer cell, the drug concentration in the cell can be monitored. 1.5 Implementation Constraints The fluorescent molecules are measured by a photomultiplier tube (PMT) module as signal peaks. The peak intensity depends on how long the laser illuminates the fluorescently labeled molecules. The PMT voltage decreases over time when the fluorescent molecules are in long-time laser illumination due to photo-bleaching effect. The blue laser provides an excitation source for cells placed in the microfluidic biochip. The PMT will always pick up background noises when displaying data since light scattering by the chip material and reflection by the component surfaces is inevitable. The interior surfaces have been blackanodized to minimize the reflective effect. Background noise will generally be reduced by lowering the PMT sensitivity knob, e.g. from 9 to 8.5.

3 Accessories like the Chip Holder are fabricated from plastic which is less robust in mechanical strength, as compared to those made from metals. The Azarel software is developed specifically for SCB-402 which allows users to automate the measurement, viewing and perform data management for experiments. Please refer to the Azarel Software User Manual to fully explore its capabilities. 2. Basics of SCB-402 2.1 Hardware Interfaces SCB-402 consists of various custom-made components that support its system operation. The pictures shown below will provide the information to user to describe components within SCB-402 when communicating to ZellChip in conditions of services or upgrades. Figure 1: SCB-401 Front View

4 Figure 2: SCB-401 Top View 2.2 Module Description Data Collection Module: The intensity of light emitted by laser-excited targets will be converted to voltage signal by the PMT. Signals from PMT are detected using a National Instruments NI6211 Data Acquisition Card (DAQ). The data are displayed on user interface as Voltage vs. Time graphs. Robot & Robot Control Board: Driven by stepper motor, the robot travels along the left-right (X) direction. A total travel range is set to be 1 (25.4 mm) away from HOME position. Robot will automatically stop upon reaching either HOME/AWAY locations. Robot comes with a stepper controller to ensure accurate control of robot position of up to 2 μm accuracy.

5 2.3 Optical Features A systematic diagram indicating all optical features and light path is shown below: Figure 3: SCB-401 Optical Layout The Blue Laser shines a laser beam at the excitation dichroic filter (DMex) through a neutral density filter (OD1.5). This beam will be reflected to the microfluidic biochip and excite the fluorescent molecules inside it. These molecules will emit fluorescence which will pass through DMex, but reflected by the emission dichroic filter, DMem to reach the photomultiplier tube (PMT). The PMT converts the laser signal into an electrical voltage. The camera based on the charge-coupled device (CCD camera) will capture the image of the microfluidic biochip reflected on the camera mirror.

6 2.4 Software Overview 2.4.1 Azarel for Robot Control and Data Acquisition Azarel software is a GUI designed specifically to operate SCB- 402. It has the function of robot control and data acquisition. Users are able to define parameters in the GUI to run various experiments. Readings are automatically plotted and results can be saved after each experiment is completed. For more details on running the Azarel software, please refer to Azarel Software Manual. Figure 4 Azarel User Interface Azarel has 3 features when it comes to saving data: a) Temporary backup file Whenever user attempts to start a new experiment, Azarel will prompt users for a saved location (default in the Azarel folder) for backup file. Data is written into the file in.csv format once it is created by users and any data acquired during the run is saved. b) File -> Save As After an experiment is completed, users can save the file by File -> Save in Azarel. This will contain all the information contained in backup file. This is a proper way of saving information after an experiment so it can be re-opened in Azarel in future. Aside from

7 experiment data, the backup file will be saved in.json format will contain every parameter the user defined in user interface such as time, date, notes, names etc. c) File -> Export Data If users wish to export data with numbers only from an experiment, then Export Data should be selected to only include the numeric information in Azarel. File saves without a format but could easily be accessed from data analytical software like excel once saved as.csv format. The information will be in 4 columns going in the order of: Time (s), Raw PMT Voltage (Volts), Averaged PMT Voltage (Volts), Averaged PMT Voltage with Background Correction (Volts). 2.4.2 ThorCam for Optical Imaging The ThorCam software allows users to visually locate test objects under the microscope in real time through the CCD camera. It also supplies features to allow user to draw on screen so it would become handy to locate laser focus on screen. The software can be found and launched from the desktop. CAUTION: The CCD Camera is directly powered by the USB cable; powering the Camera for a long time will overheat Camera. Figure 5 ThorCam Camera Scan The software will scan for authorized Thorlab cameras located on PC. Once the camera is connected, the scan window will show the specifications of the camera selected. Select Camera Name. Then, the software will proceed to the image capturing screen

8 Figure 6 ThorCam User Interface with Focus Shown Make sure to go to select Start Capture on top left corner; this will enable the camera to feed real time images into screen. Users should then be able to see the details on the microfluidic biochip by turning on LED switch once light path has been properly aligned. Caution: Avoid direct exposure to eyesight with laser in operation! 3. Experiment Tutorials The following content will include some basic hardware validation tests that allow users to take the step-by-step guide to operate SCB-402. The automated test run tutorial is recommended for calibrating purposes. Actual tests with cell samples are not covered in this manual. Please refer to ZellChip Instruction for Use Single Cell Kit documentations for procedures.

9 3.1 Automated Test Run The following procedures are highly recommended for operating SCB-402 to maximize performance during automated experiments. Prior to any operation, check laser power switch is switched to OFF position so laser wouldn t turn on once Power Supply is powered. SCB Chip should be loaded on Chip Holder gently by opening up clamps and fitting chip into place a) Connect the three USB cables to PC, which includes Camera, Robot Control & DAQ Card b) Launch Thorcam, select camera and start capture c) Turn on Power Supply switch, wait for steady green light on robot to appear d) Turn Control Knob on robot to move robot to HOME position, robot will stop once HOME is reached e) Launch Azarel and check if robot is successfully homed by reading both background & target values. Robot is homed correctly if both brackets returns 0* f) Turn on Blue Laser by laser power switch, blue light should appear from microscopic lens shining on SCB Chip g) Turn on LED and located cell/target on Chip on screen by turning robot knob, y-position knob & adjusting LED light h) Once desired target is located, select units from drop-down menu in Target bracket and current location should be saved in designated unit. Enter Time manually to indicated how long robot should stay at Target i) Move robot to background position by tuning control knob, perform steps same as (h) to set parameters for Background j) Check for steps mentioned above and close box cover k) Start Experiment in Azarel (Start -> Save As -> Open) l) Wait for graph to be generated on the user interface m) Software will automatically stop after experiment ended or when user select Stop from interface, robot will return to HOME position for both situations n) Save/Discard experiment results** * For procedure to launch software refer to section 2.4 ** Check Installation Checklist for exact location of focus location on PC screen

10 3.2 Microscope Scale-bar Test By mounting a scale-bar slide, we can measure the size of the field of view. The steps to this test are as simple as locating the scale bar patterns on the PC screen. Perform steps (a) to (j) from section 3.1. Test results should look similar to this: Figure 8: Microscope Scale-bar Test 3.3 Fluorescent Bead Test Fluorescent bead test can be considered as a mocked cell test other than the test subject is done on beads. They were injected into the microfluidic biochip to glow in excitation of laser just like cells. The following steps demonstrate how this experiment is done. During preparation, users should strictly follow operation guidelines and handling requirements working inside a lab environment. Personal protective equipment like goggles with laser protection should be prepared prior to starting experiment. Perform steps (a) to (n) from section 3.1. Test results should look similar to this:

11 Figure 9: Bead Test 4. Instrumental Maintenance 4.1 Changing Chips The biochip is generally mounted facing up on the Chip Holder. The slot on Chip Holder is designed to fit regular 25mm by 75 mm slides up to 2mm thickness for microscopic use. Users can load and unload SCB Chip by releasing clamp on holder. Chips should be handled in laboratory practice in order not to contaminate the surface of the chip when it is placed into Chip Holder slot. Be careful not to lose any washers underneath the 8 M3 screws holding Chip Holder on Robot, these washers were installed for tolerance considerations of Chip Holder.

12 Figure 10: Unscrew Chip Holder by loosening four M3 screws 4.2 PMT Calibration The dial located on the upper left corner of the power supply can be used to adjust the PMT driver voltage. By turning the knob in the clockwise/counterclockwise direction, users can adjust the sensitivity of PMT before data collection. Reading ranged from 1 to 10, the PMT sensitivity increases as the number goes up. The optimal sensitivity value for SCB-402 by experiment is from 7.5 to 9. With a higher sensitivity, more background noise is captured by the PMT and peak saturation is easily obtained if the signal level is high. See below for sample experiments at different PMT settings.

13 Figure 11 : Bead Data when PMT is set to 5.2 During Qualification Testing

14 4.3 General Troubleshooting Common Problems Power Supply wouldn t power on when the switch is ON All other modules are powered other than module A(LED, Laser, PMT & Robot) Robot not going back to target/background location upon starting experiment Action Check if the power cable is connected to the correct voltage source Check cable connection on Power Supply for loose wires, reconnect wires according to wiring diagram; Contact ZellChip for advice Power off device and reboot. Ensure robot is moved back to HOME position by control knob. Re-launch software. Contact ZellChip if problem escalates