Smart Wireless THUM Adapter

Similar documents
Smart Wireless THUM Adapter

Rosemount 248 Wireless Temperature Transmitter

Smart Wireless Products

Emerson Wireless THUM Adapter

FloBoss 107 IEC Interface

Smart Wireless Gateway

Smart Wireless Gateway

Smart Wireless Gateway

Rosemount 708 Wireless Acoustic Transmitter

ROC800-Series IEC Interface

ControlWave Micro IEC Interface

3420 Fieldbus Interface Module (FIM) Contents

Rosemount 0085 Pipe Clamp Sensor

Rosemount 928 Wireless Gas Monitor

Rosemount 2051 Pressure Transmitter and Rosemount 2051CF DP Flowmeters

1420 Wireless Gateway

Model R-1420 Wireless Gateway

WIRELESS GATEWAY. Features. Model R-1420

Smart Wireless THUM Adapter

DeltaV Wireless I/O Card

Introduction. Seamless integration with DeltaV and AMS software. Industry-proven security. The Power of WirelessHART. Easy-to-deploy Wi-Fi solutions

Rosemount 928 Wireless Gas Monitor

Emerson Wireless 1410D Gateway with 781 Field Link

Quick Start Guide , Rev DA June Rosemount 708 Wireless Acoustic Transmitter

General Specifications

General Specifications

WirelessHART Adapter SWA70

Supplementary Components WirelessHART products

General Specifications

Micro Motion Model 2200S 2-Wire Transmitter with MVD Technology

TopWorx 4310 Wireless Position Monitor

General Specifications

Micro Motion Gas Density Meters

Rosemount 2110 Compact Vibrating Fork Liquid Level Switch

Type i2p-100 Electro-Pneumatic Transducer

HART Communicator. Emerson Process Management Catalog

Fisher i2p-100 Electro-Pneumatic Transducer

Supplementary Components WirelessHART products

The Rosemount 356 Nuclear Connector

DVC2000 Series FIELDVUE Digital Valve Controllers

Rosemount VeriCase User Guide

FTP Factory Trade-In Program

SMART WIRELESS SOLUTIONS FROM EMERSON

BLISS ANAND. BA-Series Magnetostrictive Level Transmitter

Quick Start Guide MHM CC-PBF-EN, Rev 1 April Emerson A0701PBU. Emerson 701P SmartPower Module - Blue

Wireless Field Data Backhaul

Quick Start Guide , Rev DA June Rosemount 248 Wireless Temperature Transmitter

Rosemount 1595 Conditioning Orifice Plate

Programming unit VIATOR HART modems Model PU-H

Technical Information WirelessHART Fieldgate SWG70

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Siemens AG Continuous level measurement - Radar transmitters. Configuration. Mounting on a nozzle. Installation min.

Introduction. Delivers four ports to provide increased input/ output per card. Takes advantage of all smart device capabilities

S-series Foundation Fieldbus I/O

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Mobrey Squitch 2. Ultrasonic Liquid Level Switch. Product Data Sheet December 2014 IP207, Rev DA

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Rosemount 2160 Wireless Level Switch

Rosemount 2230 Graphical Field Display Remote data access for tank gauging systems

Rosemount 1595 Conditioning Orifice Plate

FloBoss 103 Flow Manager

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

UFD 5. Display for ALTOSONIC 5. Technical Datasheet. Configurable display for ALTOSONIC 5 Easy installation Durable design

Instruction Sheet PN 51A-6081C/rev.A June Model 6081-C Wireless Contacting Conductivity Transmitter

375 Field Communicator

Rosemount 3051S MultiVariable Transmitter Rosemount 3051SF Series Flowmeter MultiVariable Transmitter. Start

Mobrey Squitch 2. Ultrasonic Liquid Level Switch. Product Data Sheet February 2015 IP207, Rev DB

Series 3730 Type Electropneumatic Positioner

FLEX Ex Spring Clamp Terminal Base

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

Rosemount 1595 Conditioning Orifice Plate

Flow simulation system PROline FieldCheck

Guided Wave Radar Level and Interface Transmitter

Trendmaster* Galvanic Isolator

Continuous level measurement Radar transmitters

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

RAD-WHG/WLAN-XD. WirelessHART gateway with integrated WLAN (802.11b/g) INTERFACE Data Sheet 2720_en_C. 2 Features. 1 Description

CURRENT TO PROFIBUS PA CONVERTER

Micro Motion Series 1000 and 2000 Transmitters with MVD Technology

Fisher FIELDVUE DVC2000 Digital Valve

Ranger* Pro Wireless Condition Monitoring

Siemens AG Network transitions. 8/2 Transition from Industrial Ethernet to WirelessHART 8/2 IE/WSN-PA LINK

YT-870 / 875 Series. Rotork YTC Limited VERSION 1.06

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

DeltaV Bulk Power Supplies

S-series DeviceNet Interface Card

Quick Start Guide , Rev EB June Rosemount 248 Wireless Temperature Transmitter

Micro Motion Model 2400S Transmitters with MVD Technology

M-series Intrinsically Safe I/O

Flow Measurement SITRANS F M

Series 3730 Electropneumatic Positioner Type

ERNG-X. Description. Applications. ERNG-X Specifications DERNG2108X012

SIY. Features. PC-Programmable Signal Isolator/Converter

Analyze IT Analytical Instruments Two-Wire ph, ORP, plon Transmitters

AS-interface Network Card

DeltaV Bulk Power Supplies

Dräger Polytron 8200 Stationary gas detector (CatEx)

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Analyzer/Controller. ph/orp HART. Model 54e ph/orp ESSENTIAL INSTRUCTIONS WARNINGS RISK OF ELECTRICAL SHOCK

Rosemount 3051S MultiVariable Transmitter. Rosemount 3051SF Series Flowmeter MultiVariable Transmitter

Transcription:

Product Data Sheet Smart Wireless THUM Adapter An installation-ready solution that provides rich WirelessHART data 2- or 4-wire HART devices Flexibility to meet your most demanding applications Wireless output with >99% data reliability delivers rich HART data, protected by industry leading security Gain access to additional HART information, such as diagnostics or multivariable data Add wireless to almost any measurement point WirelessHART capabilities extend the full benefits of PlantWeb to previously inaccessible locations Contents Wireless Overview......................................................... page 2 WirelessHART... The Industry........................................ page 3............................................... page 4 Ordering Information....................................................... page 5 Specifications............................................................ page 6 Product Certifications...................................................... page 7 Dimensional Drawings...................................................... page 9

Product Data Sheet Wireless Overview SELF-ORGANIZING NETWORKS The self-forming, intelligent devices provide exceptional data reliability and network stability. The works with existing wired devices, allowing you to use existing practices, training and maintenance procedures, without the added wiring costs. LAYERED SECURITY KEEPS YOUR NETWORK SAFE Emerson Process Management s layered approach to wireless network security ensures that your network stays protected. The network devices implement Encryption, Authentication, Verification, Anti-Jamming and Key Management methods to ensure that data transmissions are received only by the Smart Wireless Gateway. SMARTPOWER Emerson devices incorporate SmartPower. SmartPower refers to the benefits that users enjoy due to the engineering efforts made to reduce power consumption. Emerson has power-optimized our instrumentation, both hardware and software, to extend life while still delivering highly reliable measurements with rich HART data and diagnostic information. The THUM Adapter is a power scavenging device that requires no external battery. RELIABLE TRANSMITTER PERFORMANCE The THUM Adapter ensures top transmitter performance in harsh and/or noisy EMI/RFI environments. DIGITAL FIELD DEVICES THAT POWER PLANTWEB The THUM Adapter powers PlantWeb by communicating important HART data and diagnostic information that ensures process health and enables economical HART architecture. MOUNTING FLEXIBILITY Any measurement point can be reached by connecting the THUM Adapter directly to any 2- or 4-wire HART device conduit entry, or through the use of a conduit adapter. WIRELESS HART The utilizes self-organizing network technology to deliver information rich data with >99 percent data reliability This innovation extends the full benefits of PlantWeb to previously inaccessible locations. SMART WIRELESS SOLUTIONS Smart Wireless Gateway The Emerson Smart Wireless Gateway integrates the self-organizing network into the host system, providing industry leading security and data reliability. Smart Wireless Field Devices Emerson Process Management has a family of Smart Wireless products to integrate different measurement types into a self-organizing network that optimizes plant performance and reduces risk to personnel. The different measurement types offered include pressure, level, flow, temperature, discrete position monitoring, ph, conductivity, and vibration. AMS Wireless SNAP-ON The AMS Wireless SNAP-ON application helps to plan and validate your wireless network using best practices. It allows for viewing of communication details graphically in real time, and maintains the health of your entire self-organizing network. 2

Product Data Sheet WirelessHART... The Industry Self-Organizing, Adaptive Mesh Routing No wireless expertise required, devices automatically find the best communication paths Network continuously monitors paths for degradation and repairs itself Adaptive behavior provides reliable, hands-off operation and simplifies network deployments, expansion and reconfiguration Supports both star and mesh topologies Industry Radio with Channel Hopping IEEE 802.15.4 radios 2.4 GHz ISM band sliced into 16 radio-channels Continually hop across channels to avoid interference and increase reliability Direct Sequence Spread Spectrum (DSSS) technology delivers high reliability in challenging radio environment Self-Healing Network If an obstruction is introduced into the mesh network, devices will automatically find the best alternate communication path. This alternate path will be created and the information will continue to flow Seamless Integration to Existing Hosts Transparent and seamless integration Same control system applications Gateways connect using industry protocols 3

Product Data Sheet Device Specifications Approvals: FM, CSA, ATEX, IECEx Input: Either 2- or 4-wire HART 5.0 device SmartPower : Power scavenging technology (no battery required) Enable Enhanced Valve Capabilities Online, in-service valve testing through AMS ValveLink SNAP-ON Application Monitor alerts such as travel deviation with AMS Device Manager, supply pressure, and electronics health Trend actual valve position Gain Access to Advanced Instrument Diagnostics Rosemount 3051S with Advanced Process Diagnostics Micro Motion Coriolis Meter Verification with optional AMS Meter Verification SNAP-ON Rosemount Radar Echo Curve Rosemount Magnetic Flow Meter Verification with AMS Device Manager Efficiently Gather Data from Multivariable Devices Rosemount 3051S MultiVariable Transmitter and 3095 Mass Flow Transmitters Rosemount 3300 and 5300 Radar Level Transmitters Micro Motion Coriolis Meters Rosemount TankRadar Rex and TankRadar Pro Rosemount Magnetic Flowmeter Rosemount MultiVariable Vortex Flowmeter Make any HART Device Wireless to Enable New Measurement Points Level Flow Valves Liquid and Gas Analytical Pressure Temperature Remotely Manage Devices and Monitor Health with AMS Device Manager Reduce troubleshooting time As found, as left data Calibration tracking 4

Product Data Sheet Ordering Information TABLE 1. Ordering Information The offering represents the most common options. The starred options ( ) should be selected for best delivery. The Expanded offering is subject to additional delivery lead time. Model Product Description 775 Output X Wireless Housing D Aluminum Mounting Connection 1 1 /2-14 NPT 2 M20-Conduit Adapter PlantWeb Functionality 1 HART Data Certification I5 FM Intrinsically Safe, Non-incendive I6 CSA Intrinsically Safe I1 ATEX Intrinsic Safety I7 IECEx Intrinsic Safety N1 ATEX Type n N7 IECEx Type n NA No Approval Wireless Update Rate WA User Configurable Update Rate Operating Frequency and Protocol 3 2.4 GHz DSSS, WirelessHART Omnidirectional Wireless Antenna WK Long range, Integral Antenna SmartPower Options 9 Power Scavenging Typical Model Number: 775XD11I5WA3WK9 ACCESSORIES AND SPARE PARTS TABLE 2. Accessories Item Description Part Number Remote Mount Kit - AI 00775-9000-0001 Remote Mount Kit - SST 00775-9000-0011 M20-Conduit Adapter 00775-9001-0001 5

Product Data Sheet Specifications Functional Specifications Input Any 2- or 4-wire HART powered device Output WirelessHART Humidity Limits 0 100% relative humidity Update Rate User selectable, 8 sec. to 60 min. Physical Specifications Electrical Connections The THUM Adapter is connected into a powered 4 20 ma loop, powering itself by scavenging power. The THUM Adapter causes a voltage drop across the loop. The drop is linear from 2.25 volts at 3.5 ma to 1.2 volts at 25 ma, but does not effect the 4 20 ma signal on the loop. Under fault conditions, the maximum voltage drop is 2.5 volts. Power Supply Minimum load on loop 250 Ohms To maintain normal operating functions of the sub-device, the power in the loop must have at least a 2.5 V margin at a 250 Ohm load. Limit power supply to 0.5 Amps maximum. Limit power supply to 55 Volts DC maximum. Mounting The THUM Adapter may be attached directly to the conduit of any 2- or 4-wire HART 5.0 device or mounted remotely by using remote mount kit. Performance Specifications ElectroMagnetic Compatibility (EMC) All Models: Meets all relevant requirements of EN 61326-1 (2006) when installed with shielded wiring. The sub-device must also use shielded wiring for installation. Vibration Effect Output unaffected when tested per the requirements of IEC60770-1 field with general application or pipeline with low vibration level (10-60 Hz 0.15 mm displacement peak amplitude / 60-500 Hz 2g). When the THUM Adapter is used on wired devices that are subject to vibration levels greater than 2g, it is recommended that the THUM Adapter be remotely mounted using the remote mount kit. Temperature Limits Operating Limit 40 to 185 F 40 to 85 C Output Specifications Storage Limit 40 to 185 F 40 to 85 C The THUM Adapter allows WirelessHART communication between the HART device it is connected to and the Smart Wireless Gateway. HART Communicator Connections Utilize wired device HART connections. Materials of Construction Enclosure Housing - Low-copper aluminum Paint - Polyurethane M20-Conduit Adapter - SST M20-Conduit Adapter O-ring - Buna-n Antenna Poly butadine terephthalate (PBT) / Polycarbonate (PC) integrated omnidirectional antenna Weight THUM Adapter only - 0.65 lbs. (0.29 kg) With aluminum remote kit - 3.2 lbs. (1.45 kg) With stainless steel remote kit - 5.4 lbs. (2.45 kg) With M20-Conduit Adapter - 0.85 lbs. (0.38 kg) Enclosure Ratings Housing option code D and remote mount kits are NEMA 4X and IP66. 6

Product Data Sheet Product Certifications Approved Manufacturing Locations Rosemount Inc. Chanhassen, Minnesota, USA European Directive Information The EC declaration of conformity for all applicable European directives for this product can be found at www.rosemount.com. A hard copy may be obtained by contacting an Emerson Process Management representative. ATEX Directive (94/9/EC) Emerson Process Management complies with the ATEX Directive. Electro Magnetic Compatibility (EMC) (2004/108/EC) Emerson Process Management complies with the EMC Directive. Radio and Telecommunications Terminal Equipment Directive (R&TTE) (1999/5/EC) Emerson Process Management complies with the R&TTE Directive. Telecommunication Compliance All wireless devices require certification to ensure that they adhere to regulations regarding the use of the RF spectrum. Nearly every country requires this type of product certification. Emerson is working with governmental agencies around the world to supply fully compliant products and remove the risk of violating country directives or laws governing wireless device usage. FCC and IC This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions: This device may not cause harmful interference. This device must accept any interference received, including interference that may cause undesired operation.this device must be installed to ensure a minimum antenna separation distance of 20 cm from all persons. Ordinary Location Certification for FM As standard, the transmitter has been examined and tested to determine that the design meets basic electrical, mechanical, and fire protection requirements by FM, a nationally recognized testing laboratory (NRTL) as accredited by the Federal Occupational Safety and Health Administration (OSHA). Hazardous Locations Certificates North American Certifications Factory Mutual (FM) Approvals I5 FM Intrinsically Safe and Non-incendive Intrinsically Safe for Class I/II/III, Division 1, Groups A, B, C, D, E, F, and G. Zone Marking: Class I, Zone 0, AEx ia llc Temperature Codes T4 (-50 C T amb 70 C) Non-incendive for Class I, Division 2, Groups A, B, C, and D. Intrinsically safe and non-incendive when installed according to Rosemount Drawing 00775-0010. Enclosure Type 4X/IP66 CSA - Canadian s Association I6 CSA Intrinsically Safe Intrinsically Safe for Class I, Division 1, Groups A, B, C, and D. T3C (-50 C T amb 70 C) Intrinsically safe when installed according to Rosemount Drawing 00775-0012. Suitable for Class I, Division 2, Groups A, B, C, and D. Enclosure Type 4X/IP66 European Certifications I1 ATEX Intrinsic Safety Certificate No.: Baseefa09ATEX0125X Ex ia IIC T4 (-50 C T amb 70 C) IP66 1180 TABLE 3. Input Parameters Loop Power Ui = 30V Ii = 200 ma Pi = 1.0 W Ci = 0 Li = 0 II 1G Special conditions for safe use (X) The surface resistivity of the antenna is greater than one gigaohm. To avoid electrostatic charge build-up, it must not be rubbed or cleaned with solvents or a dry cloth. The enclosure is made of aluminium alloy and given a protective polyurethane paint finish; however, care should be taken to protect it from impact or abrasion if located in a zone 0. N1 ATEX Type n Certificate No.: Baseefa09ATEX0131 Ex na IIC T4 (-50 C T amb 70 C) Ui = 45 Vdc MAX IP66 1180 II 3 G 7

Product Data Sheet IECEx Certifications I7 IECEx Intrinsic Safety Certificate No.: IECEx BAS 09.0050X Ex ia IIC T4 (-50 C T amb 70 C) IP66 TABLE 4. Input Parameters Loop Power Ui = 30V Ii = 200 ma Pi = 1.0 W Ci = 0 Li = 0 Special conditions for safe use (X) The surface resistivity of the antenna is greater than one gigaohm. To avoid electrostatic charge build-up, it must not be rubbed or cleaned with solvents or a dry cloth. The enclosure is made of aluminium alloy and given a protective polyurethane paint finish; however, care should be taken to protect it from impact or abrasion if located in a zone 0. N7 IECEx Type n Certificate No.: IECEx BAS 09.0058 Ex na IIC T4 (-50 C T amb 70 C) Ui = 45 Vdc MAX IP66 8

Product Data Sheet Dimensional Drawings 1.42 (36.1) 2.0 (50.8) 1.91 (48.5) 5.15 (130.8) Dimensions are in inches (millimeters) 9

Product Data Sheet 10

Product Data Sheet 11

Product Data Sheet The Emerson logo is a trade mark and service mark of Emerson Electric Co. Rosemount and the Rosemount logotype are registered trademarks of Rosemount Inc. PlantWeb is a registered trademark of one of the Emerson Process Management group of companies. HART and WirelessHART are registered trademarks of the HART Communications Foundation. Micro Motion is a registered trade name of Micro Motion, Inc. Tyco and TraceTek are trademarks of Tyco Thermal Controls LLC or its affiliates. All other marks are the property of their respective owners. Terms and Conditions of Sale can be found at www.rosemount.com/terms_of_sale 2010 Rosemount, Inc. Emerson Process Management Rosemount Measurement 8200 Market Boulevard Chanhassen MN 55317 USA Tel (USA) 1 800 999 9307 Tel (International) +1 952 906 8888 Fax +1 952 949 7001 Emerson Process Management Blegistrasse 23 P.O. Box 1046 CH 6341 Baar Switzerland T +41 (0) 41 768 6111 F +41 (0) 41 768 6300 Emerson FZE P.O. Box 17033 Jebel Ali Free Zone Dubai UAE T +971 4 883 5235 F +971 4 883 5312 Emerson Process ManagementAsia Pacific Pte Ltd 1 Pandan Crescent Singapore 128461 T +65 6777 8211 F +65 6777 0947 Service Support Hotline: +65 6770 8711 Email: Enquiries@AP.EmersonProcess.com 00813-0100-4075 Rev BA, 2/10