SNAP-IT-1U Installation Guide

Similar documents
SNAP-IT-PM Installation Guide

SNAP Ethernet Brains. SNAP Ethernet Brains. Features. Description

Part Numbers SNAP-ENET-D64 SNAP-ENET-RTC RTCBATT

Part Numbers SNAP-UP1-M64

SNAP Controllers SNAP-LCE

ADAPTER CARDS TRADITIONAL STANDALONE. DATA SHEET page 1/14. Description

RACKS SNAP N-SERIES DATA SHEET. Description

M2M OPTOGSM I/O DATA SHEET. Description

SNAP Serial Communication Modules. SNAP Serial Communication Modules. Features. Description

RACKS. CLASSIC STANDARD DATA SHEET page 1/4. Description

BRAIN BOARDS BRICK ANALOG. DATA SHEET page 1/7. Description

SNAP Serial Communication Modules. SNAP Serial Communication Modules. Features. Description. Part Numbers

BRAIN BOARDS SNAP DIGITAL. DATA SHEET page 1/7. Description

BRAIN BOARDS BRICK ANALOG INSTALLATION NOTES

CLASSIC STANDARD DIGITAL DATA SHEET page 1/4

BRAINS CLASSIC/MISTIC 16-CHANNEL ANALOG. DATA SHEET page 1/10. Description

INTERFACES TRADITIONAL PC ADAPTER CARD. DATA SHEET page 1/6. Description

BRAINS SNAP ANALOG AND DIGITAL. DATA SHEET page 1/11. Description

BRAIN BOARDS DEVICENET 16-CHANNEL DIGITAL. DATA SHEET page 1/7. Description

INTERFACES TRADITIONAL PC ADAPTER CARDS. DATA SHEET page 1/6. Description

INTERFACES. CLASSIC CONTROLLER DATA SHEET page 1/4. Unpacking. Diagram. Figure 1: G4LC32SER Physical Layout

SNAP Digital Output Modules. SNAP Digital Output Modules. Features. Description

Classic G4 16-Channel Rack. Classic G4 16-Channel Rack. Features. Description. Specifications. Part Number

Classic Brain Boards. Classic Brain Boards. Features. Description. Networking. Part Numbers

SNAP Digital Output Modules. SNAP Digital Output Modules. Features. Description

M4SARC Network Interface Card

Snap Server 4400 Power Supply

SNAP PAC R-Series Controllers. SNAP PAC R-Series Controllers. Features. Description

CLASSIC DATA SHEET page 1/5

EMC1600 Series Media Converter and Ethernet Extender Chassis

Part Numbers SNAP-PAC-EB1 SNAP-PAC-EB1-FM

Mutual approved. Mutual approved. SNAP 6-module retention rail, 25-pack (OEM) SNAP 6-module retention rail (OEM)

SNAP SERIAL COMMUNICATION MODULE USER S GUIDE

ClearCube F6151 Media Converter Chassis System with 10/100BaseTX to 100BaseFX Converter

ALLEN-BRADLEY DF1 INTEGRATION KIT FOR iocontrol USER S GUIDE

Part Numbers SNAP-IDC5DFM SNAP-IAC5FM SNAP-IDC5AF. Mutual approved SNAP-IDC5-SW SNAP-IDC5GF SNAP-IDC5-FAST-A. Mutual approved

Section. Service & Maintenance. - Core & Hard Disk Drive (HDD) - Amplifier - Monitor - UPS - Dollar Bill Acceptor - Fan Filter G - 1

iomanager USER S GUIDE

Interface Adapter Card. Part Number

SNAP TEX Mounting/Wiring Tools and Spare Parts

Part Numbers SNAP-PAC-S1 SNAP-PAC-S1-FM SNAP-PAC-S2

I/O MODULES QUAD DC INPUT. DATA SHEET page 1/5. Description

SNAP HIGH-DENSITY DIGITAL MODULE USER S GUIDE

TRC-190 User s Manual

TRC-190 User s Manual

Product names mentioned in this manual may be trademarks or registered trademarks of those products.

Classic G4 Rack. Classic G4 Rack. Features. Description. Part Numbers

4: Installing and Wiring System Components

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Part Numbers. SNAP-AIARMS-i SNAP-AIARMS-i-FM* SNAP-AIVRMS-i SNAP-AIVRMS-i-FM* SNAP-AIMA-i. SNAP-AIMA-iSRC SNAP-AIMA-iSRC-FM* SNAP-AIMA2-i.

CONTROLLERS. ISA DATA SHEET page 1/4. Description

High Power over Ethernet Midspans PD Port Model PD Port Model

M4-SERIES CONTROLLER ETHERNET CARD INSTALLATION GUIDE

Standard Analog Current Output Modules

This Datasheet for the IC660BBD110. Block 115Vac Input 16 Circuits.

G4 Digital DC Input Modules. G4 Digital DC Input Modules. Features. Description. Part Numbers

PACSystems* RX3i Central Processing Unit IC695CPE302 Quick Start Guide GFK-3038 February 2018

VAC 50/60Hz Power Adapter

EZ Switch EZ Connect N SMCFS1601/SMCFS2401

Installing the Cisco Unified Videoconferencing 3545 MCU

OPC Servers. OptoServer, OptoOPCServer, OptoENETServer

EP/2 Installation Instructions

PCI-AC5, PCIe-AC5, AC5, and G4AC5 Adapter

User Guide TL-SG1024D 24-Port Gigabit Desktop/Rackmount Switch

Disclaimer. Note that the Midspan is designed for indoor use only.

SNAP Power Supplies. SNAP Power Supplies. Features. Description. Part Numbers

SNAP PAC Brains. SNAP PAC Brains. Features. Description. Part Numbers. EB Series Brains

Fiber Optic Ethernet Media Converter Kit

Part Numbers SNAP-IT-EMU1

AC40-FIBER OPTIC REPEATER/ADAPTER USER S GUIDE

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL

AX3000 Platine Terminal Ethernet TCP/IP

SNAP PAC Redundancy Option Kit

Xpander Rack Mount 16 5U Gen 3 with Redundant Power [Part # XPRMG3-1625URP] User Guide

iomanager USER S GUIDE

CSR-G6300 6U Rack Chassis. CSR-G3300 3U Rack Chassis. Operation Manual

Features. Description. groov Build. groov View. groov Box. Part Number

GSW-1657 GSW User's Guide. 16/24-port Gigabit Ethernet Switch. Ver

Codian IP VCR IP VCR 2200 Series

Rubber Foot Pads. Rackmount Kit VAC 50/60Hz Power Adapter

Installation & Operation Guide

Adding or Replacing a PCI Card

SNAP PAC BRAINS USER S GUIDE

Installation & Operation Guide

Part Numbers SNAP-PAC-S1 SNAP-PAC-S2

Chapter 1 Product Introduction

I/O MODULES G4 ANALOG INPUT. DATA SHEET page 1/4. Description

Installation & Operation Guide

OPERATING MANUAL AC POWER DISTRIBUTION UNITS VIGILANT SERIES

USER S MANUAL. DAS-G01 The Power of Tomorrow

Leased-Line Extenders over IP

MIC-3001/8. 3U/4U CompactPCI. Enclosure for Rackmounting

Fiber Optic Ethernet Media Converter Kit VG4-SFPSCKT

PACSystems* RX3i Central Processing Unit IC695CPE305 Quick Start Guide

PACSystems* RX3i IC695ACC650

PAC Project 8.5 Release Notes. PAC Project 8.5 Release Notes. Welcome to PAC Project 8.5. PAC Project Basic. PAC Project Professional

Service & Maintenance

Table of Contents Quick Install Guide page Introduction Safety Rack System Precautions ESD Precautions...

Optional Accessories 6 2

Allworx 24x Service and Troubleshooting Guide

Transcription:

Chapter 1 SNAP-IT-1U Installation Guide Introduction The SNAP-IT rack-mount unit is a packaged solution for attaching electrical, electronic, and mechanical devices to an Ethernet network. Once attached to a network through the SNAP-IT unit, these devices can be monitored and controlled locally or remotely. Packaged in a 1U box, the unit is designed for mounting in a standard 19-inch rack. It can also be placed on a desktop or table. Typical applications include monitoring and controlling facility, computer, and telecommunications equipment, as well as remote equipment and machines. For example, using SNAP-IT units, you can: Monitor alarms and control doors Monitor equipment line voltage and current draw Turn on or off fans, lights, and motors Manage temperature, humidity, and security in facilities Report production counts Track machine throughput to plan preventive maintenance Detect and respond to machine jams and shutdowns Remotely reboot servers. SNAP-IT-1U units come in two models. SNAP-IT-1U8E includes a SNAP Ethernet brain, power supply, mounting rack for up to eight digital, analog, or special-purpose input/output (I/O) modules, and a wiring harness. SNAP-IT-1U8U also includes a power supply, 8-module mounting rack, and wiring harness, but adds the programming power of a SNAP Ultimate brain. For both models, purchase I/O modules separately as needed for your application. 1411-040414 SNAP-IT-1U Installation Guide 1

INTRODUCTION With either model, you can easily configure modules and manage devices using any authorized computer and included software. The SNAP-IT-1U8U with the SNAP Ultimate brain gives you the additional power to easily create powerful, flowchart-based control programs that run locally. Easy-to-use Windows-based software for developing these programs is included. What s in This Guide? This brief guide shows you how to set up the unit and insert input/output (I/O) modules. To configure modules and communicate with the unit, you also need the iomanager User s Guide, Opto 22 form #1440. Wiring information and specifications for modules can be found in the Opto 22 documents listed below. All documents are available in Adobe Acrobat PDF form on the Opto 22 Web site at www.opto22.com. Digital input modules Form #773 Digital output modules Form #1144 Analog input modules Form #1065 Isolated analog input modules Form #1182 Analog output modules Form #1066 Serial communication modules Form #1191 PID modules Form #1263 For Help If you have problems installing or using your SNAP-IT unit and cannot find the help you need in this guide, you can contact Opto 22 Product Support. Phone: 800-TEK-OPTO (835-6786) 951-695-3080 (Hours are Monday through Friday, 7 a.m. to 5 p.m. Pacific Time) Fax: 951-695-3017 Email: support@opto22.com NOTE: Email messages and phone calls to Opto 22 Product Support are grouped together and answered in the order received. Opto 22 Web site: support.opto22.com 2 1411-040414 SNAP-IT-1U Installation Guide

QUICK START Quick Start The following figure shows the parts inside the SNAP-IT-1U unit, looking down from the top with the front of the unit on the right. Modules (purchased separately) are shown as they would appear if eight of them were installed; they lie on their sides in pairs on the mounting rack. Power supply Loop supply fuse holder Wiring connectors (Back of unit) Wiring harnesses (Front of unit) Ethernet cable to brain Mounting rack Rack fuse Modules installed Rack holding tool SNAP Ethernet or Ultimate brain Mount the SNAP-IT Unit Mount the unit on a standard 19-inch rack, or place it on a desktop or table. Since wiring to the devices being managed is attached to connectors at the back of the unit, choose a position that allows rear access. Input/Output Modules When you purchase the SNAP-IT-1U unit, you also purchase Opto 22 SNAP input/output (I/O) modules as needed for your application. Modules come in three basic types: Digital modules monitor and control electrical, mechanical, and electronic devices that can be in one of only two states: either on or off. Dry contacts and door sensors are examples of digital devices. Digital modules contain four points. These points are used either as inputs to report a device s on/off status, or as outputs to turn a device on and off remotely. Analog modules monitor devices that have a range of possible values, such as temperature or pressure sensors. Analog modules contain either two or four input or output points. 1411-040414 SNAP-IT-1U Installation Guide 3

QUICK START Special-purpose modules provide specific functionality. Serial modules, for example, communicate with serial devices such as chart recorders and barcode readers, by sending and receiving ASCII characters via two serial ports. Wiegand serial modules receive input from security devices such as card readers that use the Wiegand protocol. PID modules monitor input signals and adjust output signals to control one proportional-integral-derivative (PID) loop per module, performing all necessary PID calculations in the module itself. Inserting Modules Up to eight modules can be inserted in the mounting rack inside the SNAP-IT unit. Any type of module can be placed in any position. 1. Make sure the unit is turned off and the power cord is unplugged from the unit. 2. If the unit is in a rack, remove it so you can take off the top cover. WARNING: Make sure power is off before continuing, or you may severely damage the module. 3. Unscrew the four small screws holding on the SNAP-IT unit s top cover. Carefully slide the cover out of the slots on each side. 4. Tip up the rack. Remove the rack holding tool from its storage position (see the diagram on page 3) and use it to hold the rack level, as illustrated below. The diagram shows modules already in position, so you can see where they will go. Rack holding tool used to hold the tipped rack in position 4 1411-040414 SNAP-IT-1U Installation Guide

QUICK START 5. Notice that each module position has a number, beginning with P0 (zero). If you are looking at the rack with the brain on the left side, module positions are as shown below: Brain Position 0 Position 2 Position 4 Position 6 Position 1 Position 3 Position 5 Position 7 6. Place the module in the position you want. When positioning a module next to another, be sure to align the male and female module keys (shown in the detailed view in the illustration below) before placing it. 7. Use two trussed-head 4-40 x 5/8 screws to hold the module in position. (Modules must be held in position with screws.) CAUTION: Do NOT over-torque screws. 1411-040414 SNAP-IT-1U Installation Guide 5

QUICK START Connect the Devices The following diagram shows device wiring to the back of the SNAP-IT-1U unit. Power supply fan Position 0 +12 V loop supply Position 2 Position 4 Position 6 Open holes for serial module connections Loop supply AC in Power switch RJ-45 to SNAP Ultimate or Ethernet brain Position 1 Position 3 Position 5 Position 7 Module connector + + Pin 1 Wiring Modules Wiring harnesses are provided for wiring between the analog and digital I/O modules on the rack and the wiring connectors on the back of the SNAP-IT unit. Field wiring is one for one, and module position numbers correspond with the connectors, as shown in the diagram above. The correct wiring harness connector for each module will probably be apparent from their position and length. In addition, each connector is marked with its module position number. 1. After modules are in place, snap the correct connector into the top of each module, matching the module s position with the number on the connector. 2. To wire field devices to a connector on the unit s back panel, unscrew the holding screws for the connector and pull it out of its housing. Wire devices according to the module data sheet (data sheets are referenced on page 2). Then snap the connector back in and reattach its holding screws. 3. If you are using an analog module that requires a loop power supply, wire the supply to the loop supply wiring connector on the back panel. See the diagram above for connections. 4. For serial communication modules, run wiring to field devices through the holes provided at the right side of the back panel (see diagram, above). Other Wiring 1. When you have finished inserting and wiring modules, replace the top of the unit and put the unit back in its location. 2. Plug the RJ-45 Ethernet connector into the back of the SNAP-IT unit. 6 1411-040414 SNAP-IT-1U Installation Guide

SPECIFICATIONS Apply Power to the Unit Plug AC power into the unit and turn the unit on using the power switch in the back panel (see the previous figure). WARNING: Electrical hazard! Do not plug in the unit unless the top cover is securely in place. Use the SNAP-IT Unit on the Network Follow instructions in the iomanager User s Guide (Opto 22 form #1440 to do the following: 1. Assign an IP address to the SNAP-IT unit. 2. Test communication. 3. Configure I/O points, event/reactions, and security. The SNAP-IT unit is ready to use. Specifications The following table lists specifications for SNAP-IT units. Communications Protocols SNMP, SMTP, FTP, and Modbus/TCP over TCP/IP, UDP/IP, and PPP Serial Port RS-232. Default rate is 19,200 Kbd; baud rate is soft-selectable from 2400 to 115,200 Kbd. Ethernet Port 10/100 Mbps Fast Ethernet, using Category 5 or superior solid UTP cable with RJ-45 connector Other Specifications Dimensions 19-inch rack-mount enclosure, 1U. 19" (482.6 mm) W, 1.75 (44.4 mm) " H, 23.5" (596.9 mm) D Power Supply Power Cord Power Consumption Temperature Humidity UL rated 120 250 VAC Manufacturer rated 100 250 VAC (Other options available by special order.) (Ordered separately) 120 VAC United States, 240 VAC United Kingdom, or 240 VAC International 30 W 0 to 55 C operating, -30 to 85 C storage 0 95% humidity, non-condensing 1411-040414 SNAP-IT-1U Installation Guide 7

SPECIFICATIONS LED Indicators and Fuses LEDs and fuses are located inside the front of the SNAP-IT unit. To open the front cover of the unit, unscrew the thumbscrews on each side of the cover and swing the cover down from the top. Mounting rack LED The mounting rack LED is visible through the front grill. Inside the box, you can see the loop supply fuse holder, the mounting rack LED and fuse, and system LEDs. Mounting rack LED Mounting rack fuse System LEDs Loop supply fuse holder Loop Supply Fuse Holder The loop supply fuse holder is just inside the front cover of the SNAP-IT unit on the right side. Mounting Rack LED The red LED on the mounting rack should be lit. If the red LED is off, check the fuse on the mounting rack as shown in the following figure. (The rack has been tipped up for easier access, as shown on page 4.) LED Fuse 8 1411-040414 SNAP-IT-1U Installation Guide

SPECIFICATIONS System LEDs System LEDs are located on the SNAP Ultimate or SNAP Ethernet brain. When you have opened the front cover, look into the unit to see the LEDs inside: Top row of LEDs Bottom row of LEDs System LEDs are described in the following table. For more information on LEDs and for troubleshooting suggestions, see the iomanager User s Guide (Opto 22 form #1440). Top Row Bottom Row LED Color Description LED Color Description ACT green Network Activity RUN green Normal Operation FD green Full Duplex Mode 3VF red 3 Volt Fault ERD green Ethernet Receive Data 5VF red 5 Volt Fault ETD green Ethernet Transmit Data FLT red Microprocessor Fault 10MB green Ethernet Link Detection at 10 Mbps 100MB green Ethernet Link Detection at 100 Mbps SRD green Serial Receive Data STD green Serial Transmit Data Digital Module LEDs In addition to the system LEDs shown in the table above, numbered LEDs on each digital module indicate the status of the module s four points. A lighted LED indicates that the digital point is on. Module LEDs are not visible unless the top cover of the unit is open. 1411-040414 SNAP-IT-1U Installation Guide 9

NOTES ON BRAIN MAINTENANCE Notes on Brain Maintenance Removing Modules Maintenance instructions for the brain are in the iomanager User s Guide (Opto 22 form #1440). If you need to change the SNAP-IT unit s IP address, reset it to factory defaults, or download new firmware, you will need to use the instructions in this guide. CAUTION: Jumpers in the SNAP-IT-1U unit are different from jumpers on other SNAP-IT units. Be sure to follow the Standard SNAP Ethernet or SNAP Ultimate Brain diagram in the user s guide to determine which jumper is which. Removing Modules 1. Turn off power and unplug the power cord from the unit. WARNING: Make sure power is off before continuing, or you may severely damage the module. 2. If the unit is in a rack, remove it so you can take off the top cover. 3. Unscrew the small screws holding on the SNAP-IT unit s top cover. Carefully slide the cover off. Each module position is numbered (P0 through P7), but the numbers are not visible when modules are in place. Check the module s position in the diagram on page 5. 4. Tip up the rack. Use the rack holding tool to hold the rack level. 5. Remove the module s two hold-down screws. Lift up on the module to remove it. NOTE: If you are replacing the module with no change in wiring to it, you can unplug the field wiring connector on the old module s top and use it with the new module. 6. When you have finished removing and replacing modules, replace the top of the unit, put the unit back in its location, and plug the power cord back in. Copyright 2003 Opto 22. All rights reserved. Printed in the United States of America. The information in this manual has been checked carefully and is believed to be accurate; however, Opto 22 assumes no responsibility for possible inaccuracies or omissions. Specifications are subject to change without notice. All trademarks, trade names, logos, and service marks referenced herein belong to their respective companies. 10 1411-040414 SNAP-IT-1U Installation Guide