1530R & 1540 All-in-One Pro Data/Phone Tools

Similar documents
CONEC Industrial Ethernet Circular Sealed RJ45 Connector System consists of a RJ45 Plug Kit, a Receptacle Kit and a Protective Cover Assembly.

CNE301 Network I Lab 04 Building a cross-over cable and configuring back2back network.

DXE Technical Note: Importance of Correct Termination of Shielded Cat5 Networking Cables. By Scott MacDonald, KD8BDX. Parts list:

Student Lab Manual. Networks and Communications (COMP277L) SYSTEM PROPERTIES. Dr. Mohamed Ben Laroussi Aissa Room 11 A- 2.

8.0.1 Chapter 8 Introduction

SYSTIMAX GS3 and 1100GS6 Evolve Modular Panel Instructions

Tools and Testers. Section Contents TOOLS AND TESTERS

SYSTIMAX 360 PATCHMAX Modular Panel Instructions

MODULAR PLUGS, ACCESSORIES AND TOOLING

Making Ethernet Cables

10 How to Setup a Home or Small Network

Crimplok ST* and SC Non-Adhesive Fiber Optic Single & Multi-mode Connectors

Distribution Module Cat 5E Panels

Modular plugs, accessories and tooling

Transparent Covers for Rail-Mounted Terminal Blocks, Usable with Lead Seals Description and Handling

with its cables, connectors, Switches, Hubs and topologies

2 PIECE BOARD-TO-BOARD

Wireless Area Controller (WAC60)

Termination for 568A and 568B pin configurations.

VDV TOOLS & TEST EQUIPMENT

Patch Cords. Handset Cord...Page 46. Category 6 Patch Cords...Page 42. Category 5e Patch Cords...Page 42. Modular Extension Cord...

Complete Train Control. Run Your Trains, Not Your Track!

Modular plugs, accessories and tooling

Cables and Connectors

TELEPHONE FLUSH WALL PLATE

INSTALLATION GUIDE. LANmark EVO Series Snap-in Connector UTP

Distribution Module Panel (DM)

TOOLS TOOLS. Chapter Summary All the tooling required to install optical fiber and twisted pair connectors

Factory Line Accessories FL PLUG RJ FL CRIMPTOOL

Wireless Area Controller (WAC50) i. Installation Instructions

Replacing the Power Supply

Installer Connectors Overview Suitable for lighting, power, HVAC & other applications

Installing a Power over Ethernet injector

April 2017 Rev 1

Telephony Multi-Taps. 9000T-TP Series

Telephone Accessories

Cabling Infrastructure

Lab - Building an Ethernet Crossover Cable

TOPJOB S Sensor/Actuator Terminal Blocks Pluggable Signal Level with Push-in CAGE CLAMP Reliability

Installing the Cisco 2524 and Cisco 2525 Routers

CONNECTORS Coax & Twisted Pair

Installing and Removing SDRAM and DRAM

Application Specification Connectors and Quadrax Contacts 09 MAR 12 Rev G. Quadrax Rectangular 1. INTRODUCTION

car phone Talking on the telephone from a phone service stand at the Hotel Constance in Pasadena, California. Circa 1925.

Han-Brid. Contents Han-Brid Features Han-Brid Data interfaces Han-Brid Overview Han-Brid Cu

LED. Sign Module. Assembly Manual

Replacement Keyswitch Assembly

Power Supply and Fan Module Installation

Cat. No. Handle Color Cutting Knives Cuts Handle Overall Length Weight VDV yellow Custom notch for CCS coaxial cable

Installing PRO/DGX or Pro Soloist MIDI interface. R Grieb 9/08/2017

TOPJOB S Sensor/Actuator Terminal Blocks with Push-in CAGE CLAMP Reliability

Connect the drop cable to the ODU (PSU port) and LPU

MTA-156 IDC Quad Connectors

LANmark Snap-In Toolless connector. screened, with rear cover CAT7 GG45 INSTALLATION GUIDE

FreeNAS Mini and Mini XL Network Upgrade Kit

STANDARD FOR ELECTRICAL CONTACTS, RETENTION CRITERIA

Sure Coat Modular Gun Control System Part C: UCS ProfiBus Interface Card. Customer Product Manual Part B

WINSTA. Full Line Catalog 2008/2009

Portal TI+ Installation Manual

CABLE CONNECTOR 6100/6200/6200S/6230 SERIES. 2.54mm Pitch Flat Ribbon Cable Connector K-7

3 Chapter Introduction. 3.2 Copper Cable

Product Data Sheet. SC Thead-Lock Connector Assembly Instructions. Page 1 of 5 QUALITY FIBER COMPONENTS, EQUIPMENT, & SUPPLIES

ILC LightLEEDer MicroLite 1000P Retrofit Installation

Removing and Replacing Parts

USER MANUAL. MODEL 1225 ParaLink TM Parallel Short Range Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)

IDC Field Wireable eurofast & picofast Connectors

D-3100S Standard 1-Row Type

M204SMB Surface Mount Box Instructions

Data sheet. HDC insert HDC HQ 7 FC

ODU AMC HIGH-DENSITY RECEPTACLE STYLE 6 ASSEMBLY INSTRUCTION

Twisted Pair Cable Testers Int l Phone

Rigid/Bus Bars. Standard Copper Rigid / Bus. PC Board Stiffeners and Current Carrying Busses. Table of Contents. Benefits

A+ Guide to Managing & Maintaining Your PC, 8th Edition. Chapter 16 Networking Types, Devices, and Cabling

Assembly Instructions

Connecting and Routing the Cables and Wires

TECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2

BLACKBOX NETWORK SERVICES. one source for worldwide infrastructure services

Data sheet. HDC insert HDC HQ 5 FC

Communication Wiring Color Codes

ICM-400 Series Intercom Stations

Heathkit HR-1680 PC Card Extender. Heathkit HR-1680 PC Assembly Extender Assembly

INFORMATION AND COMMUNICATION TECHNOLOGY

TDM To MiniMech conversion ProceDure

Processing Instruction

ODU-MINI-SNAP. Series S - IP50 and IP68 FP-Locking Concept Keying with Insulation Body. Series S

HANDYLINK APPLICATION SPECIFICATION

* C29* 68P81084C29-0 RETROFIT INSTRUCTIONS FOR MCS 2000 MOBILE RADIOS. Conversion From Dash/Local Mounting To Remote Mounting

7011-C, 7012-C, 7013-C, 7015-C, 7018-C, 7021, MTC-2 Mass Terminated Assembly Twisted pair (45) 96-pin female 96-pin female 2 6.

Passive network equipment. Catalog

Model 2704 Parts List * = Standard Equipment 〇 = Circuit Diagram

imac Intel 21.5" Retina 4K Display Power Supply Replacement

Figure 36. Connecting the 24V/DC power supply

BUSBAR CONNECTIVITY QUICK REFERENCE GUIDE

HGR-2488 Prism Installation Instructions

Product Specifications (for connectors), and (for headers), provides product performance requirements and test result information.

(Cat. No A1B, -A2B, -A3B, -A3B1, -A4B Series B) Installation Data. Make sure you have these items:

Power Supply Installation

BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide

Connecting the EN-4000 to DC Power

AT&T CIB 3032 Z7308 H01B) ATTENDANT CONSOLE (3162)

Transcription:

1530R & 1540 All-in-One Pro Data/Phone Tools Safety release To cut & strip telephone cable: 1. To cut & strip 4- & 6-conductor flat cable, insert the cable into the slot labeled 6 mm. Squeeze the handles to close the blades & cut the cable. 2. Rest the cut cable end on the inside ridge for 6 mm. Squeeze the handles to close the stripping blades & pull the cable out to strip the outer insulation. 3. For 8-conductor cables, perform step 1 using the 12 mm slot position. To crimp cable: 1. Assemble cable according to the connector manufacturer s instructions & according to the required pin-out. See pages 35-38 for reference. 2. Install the connector/cable assembly with the key tab facing upward into the required 4-pin, 6-pin or 8-pin crimp. Squeeze the handles through a complete ratchet cycle. Handles will reopen when crimp is complete. Note: The 1530R is for WE/SS modular plugs; the 1540 is for AMP (Tyco) plugs. Connector Crimp Cavity RJ22 handset 4P RJ11/12 6P RJ45 8P Tool Operation and Use Guide 22

Telephone Cable Assembly To assemble telephone cable: 1. For 4- & 6-pin connectors, strip approximately 1/4 of the outer cable. For 8- & 10-pin connectors, strip approximately 1/2 of the outer cable. 2. Do not strip the smaller internal wires. 3. For flat cables, slide the wires into the connector. Make sure the wire ends are butting against the very front edge of the connector & that all wires are located under the pins. 4. For round cable (twisted pair), arrange the wires in pairs based on the color. Verify the wiring pin-out required for the system. Typically pairing is either 1-to-1, or is paired for pins 1 & 2, 3 & 6, 4 & 5, & 7 & 8 (for EIA standard). The equipment connecting to the cable determines the wiring pin-out. 5. When the wires are arranged for the correct pin-out, slide the wires into the connector. Make sure the wire ends are butting against the front edge of the connector. 6. Install the cable/connector assembly into the crimp tool. Crimp the connector to force the pins into the wires & to engage the strain relief on the cable. 35 Paladin Tools

Data Network Cable Assembly Technical references: Use the configuration listed below for required network type. Cabling & Network Scheme Configuration Type Category 1, outdated, no criteria........eia/tia-568a or 568-B Category 2, to 1Mhz (CAT-2)...........EIA/TIA-568A or 568-B Category 3, to 16Mhz (CAT-3)..........EIA/TIA-568A or 568-B Category 4, to 20Mhz (CAT-4)..........EIA/TIA-568A or 568-B Category 5, to 100Mhz (CAT-5).........EIA/TIA-568A or 568-B Enhanced Category 5, to 150Mhz (CAT-5E).EIA/TIA-568A or 568-B Category 6, to 300Mhz (CAT-6).........EIA/TIA-568A or 568-B Ethernet 10 Base-T..................EIA/TIA-568B 100 Base-T.......................EIA/TIA-568B ISDN...........................EIA/TIA-568A USOC 10 Base-T....................USOC AT&T 258A.......................EIA/TIA-568B 100 Base-T4......................EIA/TIA-568B 100 Base-T8......................EIA/TIA-568B ATM 155Mbps.....................EIA/TIA-568B TP-PMD..........................EIA/TIA-568B 100VG-AnyLAN....................EIA/TIA-568B Token Ring.......................EIA/TIA-568B Systimax SCS (AT&T).................EIA/TIA-568B Recommended tools: Jacket stripper, scissors, crimping tool, & continuity tester. Assembly instructions: 1. Strip 1 inch of the outer jacket off the cable. DO NOT strip the inner wires. Be sure not to score the insulation on the inner wires when stripping the outer jacket. 2. Untwist the paired wires. 3. Configure the wire scheme by the color code for the network type you are installing. See the network wiring chart on the inside back cover. 4. Make sure all the wires are straight in line & not staggered. (cont d on page 37) Tool Operation and Use Guide 36

5. Use scissors to trim the wires to.5 inches. Make sure all wires are of the same length & in a straight line. 6. Grip the wires & jacket joint between thumb & forefinger to hold steadily together. Gently slide the wires into the RJ45 plug until they begin to track in the inner channels of the connector. 7. Push the wires all the way into the connector until the front of the wires butt against the front edge of the connector. Make sure you can see the copper tips when looking at the front end of the connector. 8. Install cable & connector assembly into the crimp tool & crimp until all pins are set. All pins should be fully compressed & of equal height after crimping. Wire Pairing Chart 37 Paladin Tools

Data Network Wiring Chart EIA/TIA-568A RJ45 Plug EIA/TIA-568B RJ45 Plug USOC RJ45 Plug Ref. 0.50 inches all types Tool Operation and Use Guide 38