SIRIUS CAPACITOR MODULE User Manual. Model number: A-1.7C-M-SD-G Version 1.0; Release Date: April 2018

Similar documents
DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

SATA II HDD Canister KISS DA 435 Quick Reference Guide

Model 2600B-PM V Protection Module with 1 A Clamp. Description / April 2015 *PPA * 1

SUN2000P-375 W Smart PV Optimizer. User Manual. Issue 01. Date HUAWEI TECHNOLOGIES CO., LTD.

Installing and Configuring Rialto Analytic Appliances

True Sinewave Power Inverter 1000W & 2000W 230V , Owner s Manual

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

ELV12 Series. Instruction Manual

PV Rapid Shutdown device

B-Box H Installation Guidance

User Guide. Control Box. RoscoLED TM.

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Model 2380 Rack-Mount Kit

DTC P0AA6 - High Voltage Isolation Fault

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

HV-CS kv Edge Mount Triaxial Jack

Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Smart Grid Tie Microinverter User Manual

Analog Monitor Installation Manual

Model 2657A-LIM-3 LO Interconnect Module

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24

POCKET MULTIMETER Model No: MM18

User's Guide. Extech AM A AC Analog Clamp Meter

User Guide True RMS Multimeter Extech EX205T

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

Power Quality Recorder

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

700 Series 200 Amp Clamp Meters

Model 7705 Control Module

PanelView Plus/VersaView CE Terminals and Display Modules

V E2B Snap-in I/O Module

Energy Management System. Operation and Installation Manual

Autoranging True RMS Multimeter User Manual

Model 2380 Rack-Mount Kit

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

P216 Series Condenser Fan Speed Controller

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens).

User's Guide. MiniTec TM Series Model MN25 MultiMeter

Mini Digital Multimeter

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

Innovative Circuit Technology Ltd.

Disclaimers. Important Notice

Series 370 S SoftwSystem are Qui Switch/Mult ck Start G imeter uide Quick Start Guide

V E1B Snap-in I/O Module

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

OPERATING INSTRUCTION

High Power Electronic Gear Installation and operation Guide

Installation Guide for America Solar Wholesale Photovoltaic Modules

22-60VDC Grid Tie Microinverter User Manual

Mini Digital Multimeter

actilib Library 2U Quick Start Guide

NJ-Series Power Supply Unit NJ-PA/PD

EOS-6000 Series Optical A/B Switch User Manual DC Version

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

General Warranty. For more details, please refer to the user manual on the supplied CD, it can also be downloaded at

HX1 Bluetooth Stereo Headset

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

Model (DRS-54V) Ver. 2.0 August. Dongah Rectifier System Operating Manual

PRO-1250D CT MID DIN rail three phase four wire energy meter.

Installation Instructions

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

9040/9040UK. Users Manual. Phase Rotation Indicator

I/O SIGNAL CONDITIONER

EX-RC1 Remote I/O Adapter

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Power Quality Recorder

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

Nature Power Inverters. Modified Sinewave 1000w/1500w True Sinewave 1000w/2000w. Owner s Manual

Installation, Operation and Maintenance Manual

Redundancy unit CP-A RU

Digital ac/dc (24V) Input Module

User Guide. Single-Link DVI Fiber Optic Extender DVI-7315

P216. Condenser fan speed controller. Product bulletin. Features

Conext CL-60 Inverter Firmware Upgrade Process

Agilent Technologies E5346A 38-Pin Probe and E5351A 38-Pin Adapter Cable

Product Manual. USB Charging Hub 10 Port Hi-Power 2.4A USB Charger Hub. Coolgear, Inc. Version 1.1 September 2017 Model Number: U2CHGRHUB10

Installation Instructions

User s Guide. 600A AC Clamp Meter. Model 38387

Solar Combiner Enclosure

ABB Drives. User s Manual. Digital I/O Extension Module RDIO-01

LCI User Manual mantracourt.com

2 Mesa Ethernet Dock User s Manual

Vision OPLC V TR6/V350-J-TR6

User Guide. Digital Picture Key Chain NS-DKEYBK10/ NS-DKEYRD10

Transcription:

SIRIUS CAPACITOR MODULE User Manual Model number: 3550-48-A-1.7C-M-SD-G Version 1.0; Release Date: April 2018

Introduction The Sirius Capacitor Module ( Sirius ) is supercapacitor-based storage that uses supercapacitors as storage cells instead of chemical cells. Kilowatt Labs proprietary balancing, control and charge retention algorithms control the operation of the supercapacitor-based modules, making Sirius a safe, efficient and effective alternative to chemical batteries wherever chemical batteries are deployed. Legal Provisions No part of this User Manual ( Manual ) may be reproduced, or transmitted, in any form or by any means, without the prior written permission of Kilowatt Labs, Inc. ( Kilowatt or the Company ). Specifications in this Manual are subject to change without notice. While every attempt has been made to make the Manual accurate and up-to-date, users are cautioned that product improvements may cause the Company to make changes to specifications without advance notice. Users are encouraged to consult the Company or its Resellers before using the Manual. Neither the Company nor its Resellers shall be liable for any indirect, incidental, or consequential damages under any circumstances caused by reliance on the material presented, including, but not limited to, omissions, typographical errors, arithmetical errors or listing errors in the content material. The content of this manual shall not be modified without the written authorization of the Company. Trademarks All trademarks are recognized, even if not explicitly identified as such. Kilowatt Labs is a registered trademark of the Company. Safety This Manual contains instructions for unpacking, mounting, installation and operation of a Sirius module. Please read this manual carefully before operating the system and follow all warnings and safety instructions. Please follow the instructions in this Manual carefully to prevent accidents. The Sirius module must be installed by trained personnel. Warning Selling and installation of this product is only through the Company s Resellers who are trained on installation, operation and maintenance of the Sirius modules. Sirius Capacitor Module User Manual 2 Model Number 3550-48-A-1.7C-M-SD-G

Table of Contents Unpacking and Handling 4 Installation 4 Parallel Connection 5 Product Overview 5 Panel Description 6 LCD Description 7 COMM LED 8 COMM Connector 9 Power Switch 9 Safety Features 9 Operating Procedures 10 Trouble Shooting: Faults and Solutions 10 Maintenance 10 Safety 11 Storage 11 Disposal 11 Technical Specifications 12 Sirius Capacitor Module User Manual 3 Model Number 3550-48-A-1.7C-M-SD-G

Unpacking and Handling Unpacking Inspect the shipping carton for damage prior to unpacking the module. Document (photograph) any damage and report this to the Company or the Company s authorized representative and to the shipping agent immediately. Remove the module from the shipping carton and retain the shipping materials until the unit has been inspected and is determined to be operational. The module must be removed from the carton by lifting the module body. Do not remove the module by the terminal posts. The following items are included in the package: Sirius Capacitor Module: 3.55kWh48VDC Compact Disc with the monitoring software Manual and application software. NOTE: The original shipping materials are approved for both air and ground shipment. Handling The Sirius Capacitor modules are designed to provide years of trouble-free operation. Proper handling is required to avoid damage to the module. In particular, the following handling precautions should be observed: Do not lift the module by the terminal posts. Do not stack modules once they have been removed from the shipping containers. Do not drop the module. Internal damage may occur that will not be visible from the exterior. Do not step on the module. Protect the module from impact. Installation Installation must strictly follow the national safety regulations in compliance with the enclosure, installation, creep age, clearance, casualty, markings, and segregation requirements of the end-use application. Installation must be performed by professional installers only. Switch off the system and check for hazardous voltages before altering any connection! Sirius modules must be handled only by qualified and trained personnel. Installation should not exert bending or twisting torque to the module enclosure. Parallel Connection of Sirius Modules The parallel combination of the Sirius modules is as shown below. Any number of modules can be connected in parallel. Sirius Capacitor Module User Manual 4 Model Number 3550-48-A-1.7C-M-SD-G

Product Overview The appearance of the Sirius Capacitor Module is shown in the figure below: Sirius Capacitor Module User Manual 5 Model Number 3550-48-A-1.7C-M-SD-G

Panel Description The figure below describes the front panel components of the module: 1 COMM Connector 2 COMM LEDs 3 LCD 4 Power Switch LCD Messages Once the power is switched ON from the Power Switch, the module gets power and the LCD shows the following message: Sirius Capacitor Module User Manual 6 Model Number 3550-48-A-1.7C-M-SD-G

Overcurrent (OCD) When the module has an overcurrent fault (OCD), the LCD shows the followig warning message: This means the current has increased beyond the cut-off current of 125A (in the illustration, the LCD shows that the module current has increased above 125A). Overvoltage (OV) When the module has an overvoltage fault (OV), the LCD shows the following warning message: This means the module voltage has increased beyond the cut off limit of 54.5V. The LCD shows the voltage at that time as well (in the illustration, the LCD shows that the module voltage has increased to 56.1V). Undervoltage (UV) When the module has an undervoltage fault (UV), the LCD shows the followig warning message: Sirius Capacitor Module User Manual 7 Model Number 3550-48-A-1.7C-M-SD-G

This means the module voltage has decreased below the cut off value of 44V. The LCD shows the voltage at that time as well (in the illustration, the LCD shows that the module voltage has decreased to 43.9V). Overtemperature (OT) When the module has an overtemperature fault (OT), the LCD shows the followig warning message: This means that the temperature of the module has increased beyond the cut-off value of 75 C. The LCD shows the temperature at that time as well (in the illustration, the LCD shows that the module temperature has increased to 75.1 C). COMM LEDs COMM LEDs are the LEDs which show the status of communication of the control module with the application software. There are 4 LEDs for the four control modules in the Sirius Capacitor Module. Each LED has the following status: OFF: The control module is not powered and hence not communicating with the application software. ON (Green): The control module is powered ON but no communication with the application software. Blinking Red: The control module is communicating with the application software. COMM Connector This is a RJ45 connector to monitor the module using the application software. Power Switch When the power is switched ON using the ON/OFF switch on the front panel, the module electronics are powered up. The module is now functional and can be operated. Sirius Capacitor Module User Manual 8 Model Number 3550-48-A-1.7C-M-SD-G

Safety Features This Sirius Capacitor Module has the following safety features: Shut-down due to Safety Events: Over-voltage cut off: This feature will be activated when the module voltage goes beyond the high voltage threshold of 54.5V. Under-voltage cut off: This feature will be activated when the module voltage goes below the low voltage threshold of 44V. Over-current cut off: This feature will be activated when the module current exceeds the maximum load capacity of 125A. Over temperature cut off: This feature will be activated when the module temperature exceeds the maximum temperature limit of 75 C. These features work as follows: Disconnect Event Disconnect Value Reconnect Feature Over voltage 54.5V Module senses system voltage and reconnects automatically when system voltage is 53.0V Under voltage 44.0V Module senses system voltage and reconnects automatically when system voltage is 46.0V Over Current 125A Module senses system voltage and reconnects if V- system <> +-1V from Vbat@ rest Operation Procedures The module should only be operated within the specified voltage and temperature ratings. Observe polarity indicated on module. Do not reverse polarity. Follow the steps below (in sequence) to operate the module: Configure the PC IP in the network and internet settings of the monitoring device. Connect the RJ45 cables to the COMM connector slot to start communication and monitoring. Turn on the power switch the LCD will start to display data. Install the monitoring software application in the monitoring device from the CD provided with the module. The module will continue to function even when the RJ45 connector is removed (monitoring OFF). The module can be shutdown either by the ON/OFF switch or by removing the output cables from the module terminals. NOTE: Switch OFF the module when not in use as the module is self-powered or else, it can result in faster self-discharge of the module. Sirius Capacitor Module User Manual 9 Model Number 3550-48-A-1.7C-M-SD-G

Trouble shooting: Faults and Solutions Over-voltage (OV) The OV cut-off is at 54.5V. Set the charger s limit below 54.5V to prevent an OV event. If the voltage exceeds 54.5V, the module shuts down and locks. The module unlocks when the module s surface charge is cleared, and the voltage drops below 53V. The event can be repeated if the charger is still ON and operating in the same condition. Troubleshooting: Check the charger s upper cut off limit and ensure it is set below 54.5V. Under-voltage (UV) The UV cut-off is 44V. If the voltage goes below 44V, the module shuts down and locks. The module unlocks when the voltage goes above 44V. The event can be repeated if the load is still ON and operating in the same condition. Troubleshooting: Check for the operating load lower cut off limit and ensure it is above the lower threshold limit of 44V. Over-Current (OC) OC occurs when the current goes above 125A or when the module is short-circuited. In this event the module shuts down and locks. Troubleshooting: Switch off the module and check the voltage across the module terminals to find whether there is a short circuit. In case of a short circuit, check the operating circuitry and clear the short circuit. The module can be unlocked in 30 seconds after the current goes below 125A. Over-Temperature (OT) OT occurs when the module temperature goes above 75 C. In this event, the module shuts down and locks. Troubleshooting: Shut down the module and check the room temperature and ensure the cooling units are operating properly. Leave the module to cool till the module temperature comes below 75 C. Now, turn ON the module. Multiple Errors The above-mentioned errors can occur simultaneously and will be shown on the LCD. To clear these, follow the steps explained in the above sections. Maintenance The Sirius Capacitor Module does not require periodic maintenance. Sirius Capacitor Module User Manual 10 Model Number 3550-48-A-1.7C-M-SD-G

Safety Strictly observe the safety instructions listed below to ensure safe handling, injury prevention and trouble-free operation of the module. Never touch the positive (+) or negative ( ) terminals as the module can be charged and cause fatal electrical shocks. Always verify that the module is fully discharged before handling the module. Ensure precautions to prevent short-circuit under all circumstances. Do not operate the module above the specified voltage. Do not operate the module above the specified temperature rating. Do not touch the terminals with conductors while the module is charged. Serious burns, shock, or material fusing may occur. Wear protective equipment when handling the modules including gloves, eyewear and hardhat. Protect surrounding electrical components from incidental contact. Do not use the module in an open environment, in rain or in a place exposed to water and other liquids. In case the module is physically damaged due to any event, do not install and energize the module under any circumstances and contact your Reseller. When connecting to external devices ensure that galvanic isolation does not exceed 1500V. Under no circumstances must the charge / discharge current exceed 125A. Under no circumstances must the charging voltage exceed 54VDC for more than 60 seconds. During charge cycle ensure never to exceed constant voltage of 54VDC and constant current of 125A. All modules must be at 100% SOC before connecting in series or parallel. The maximum number of modules that can be connected in series is 8 with a Module Combiner. Under no circumstances should you connect more than 3 modules in series. If you want to connect more than 8 modules in series, please contact your Reseller. Modules cannot be connected in a series parallel combination under any circumstances. Storage The Sirius modules can be stored at any SOC (State of Charge) without affecting the projected supercap cell cycle life of 1,000,000 cycles. Projected supercap cell calendar life (the projected life of the supercap cells (in years) from the date the module is first operated) is 45 years. Shelf life (the life of the module (in years) from the date it is manufactured to the time it is first operated) is 10 years. Disposal Do not dispose of the module in trash. Dispose of according to local regulations. Sirius Capacitor Module User Manual 11 Model Number 3550-48-A-1.7C-M-SD-G

Technical Specifications Nominal Voltage Voltage Range Capacity Maximum Charge Rate (0% -100% SOC) Maximum Discharge Rate (100% - 0% SOC) Maximum Charging Voltage Internal Resistance Supercap cell DC to DC Roundtrip efficiency (@125A) Supercap cell Operating Temperature Galvanic Isolation 48VDC 44VDC 54VDC 3550Wh Sirius Capacitor Module User Manual 12 Model Number 3550-48-A-1.7C-M-SD-G 125A 125A 54VDC 6mΩ 99.1% -30⁰C to 85⁰C 1500V Projected Cycle Life 1,2 1,000,000 Projected Calendar Life 2,3 Shelf Life 4 Warehousing Communication Port Monitoring Data Remote Control Input Safety Terminal Type Module Casing Material Dimensions (w x d x h) Weight Self-discharge 5 CE Certification 6 Physical Damage Short Circuit Galvanic isolation Charge / Discharge Current Charging Voltage Charge Cycle Series Connection Maximum number of modules that can be connected in series 7 Maximum number of modules that can be connected in parallel Series Parallel Connection 45 years 10 years Can be stored at any SOC without affecting cycle life TCP/IP RJ45 Ethernet Temperature, Voltage, Current, Energy, Supercap Balancing Battery Self-Check Shutdown on - Over-Charge, Over-Discharge, Over-Current, Over- Temperature, Reverse Polarity, Cell Imbalance F12 Aluminium 600mm x 534mm x 200mm Approx.75kg 5% after 25 days EN55022:2010/AC:2011,EN61000-3-2:2006+A2:2009, EN61000-3- 3:2008, EN55024:2010 Precautions In case the module is physically damaged due to any event, do not install and energize the module under any circumstances and contact an authorized technician Ensure precautions to prevent short-circuit under all circumstances When connecting to external devices ensure that galvanic isolation does not exceed 1500V Under no circumstances must the charge / discharge current exceed 125A Under no circumstances must the charging voltage exceed 54VDC for more than 60 seconds During charge cycle ensure never to exceed constant voltage of 54VDC and constant current of 125A All modules must be at 100% SOC before connecting in series 8 with Module Combiner Please consult with Kilowatt Labs or its Reseller when connecting the modules in series. Under no circumstances should more than 3 modules be connected in series without the Module Combiner No limit Modules cannot be connected in a series parallel combination under any circumstances

SiriusVIEW Monitoring Software Individual Cell Monitoring of voltage Monitoring of current, max. & min. voltage, temperature, DOD, Module SOC, rate of charge, rate of discharge, time to discharge, balance energy, total energy delivered over lifetime, graphs System Monitoring of all modules connected together 1 Projected Cycle Life of Supercap cells. 2 Additional terms and conditions, including a limited warranty, will apply at the time of purchase. 3 Projected Calendar Life of Supercap cells from the date of first operation. 4 Shelf Life is the life of the module (in years) from the date it is manufactured to the time it is first operated. 5 Self-discharge: (1) 30% after 30 days; (2) 80% after 60 days; Self-discharge only when not charging or discharging; No memory effect; Module can be recharged to 100% at any time. 6 CE certification is completed for Supercap cells. 7 Consult Kilowatt Labs or its Reseller for information on connecting modules in series. Product dimensions are for reference only unless otherwise identified and may change without notice. For critical applications, please contact Kilowatt Labs, Inc., or its Reseller. Sirius Capacitor Module User Manual 13 Model Number 3550-48-A-1.7C-M-SD-G