OCEAN WATERPROOF WEIGHING SCALE USER MANUAL

Similar documents
User Manual. Waterproof Weighing Scale. ELW Plus / ESW Plus ELW Plus Wipower

GMC-206/215/230 Digital Desktop Weighing Scale Operation Manual

American Weigh Scales H-110. User Manual. H-110 (110lb x 0.05lb) Copyright 2010 American Weigh Scales, Inc. All rights reserved. Rev. 4.

MPB SERIES Electronic Balances. r1 v1.09. Operation Manual

EB300 Weighing Scale Operation Manual

OP-W Series User Manual

TL-Series. User Manual. American Weigh Scales. TL-330 (330lb x 0.2lb) TL-440 (440lb x 0.5lb)


DWP-PC SERIES PRICE COMPUTING SCALE User s Guide

IDS-801 Series Compact Bench Counting Scale. User Manual

DWP-98 Series. Counting scale. User s Guide PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE ATTEMPT TO OPERATE THE INSTRUMENT

WM-25 USER S MANUAL. Manufacturer s Declaration of Conformity

Kilotech. KRS SWP Series. Counter-top weighing scale. NTEP (USA) and Measurement Canada approved.

NB/NHB Precision Balance

CONTENTS. PRECAUTIONS Introduction Installation... 7

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

Bright Advance Corporation USER INSTRUCTIONS

acaia Coffee Scale Operation Manual

EHC-WF. User/Technical Manual. Contents subject to change without notice

MWP SERIES. High Precision

MODEL TI-700. Digital Weight Indicator (with wireless weighing capability) User Manual

uline.com OVERVIEW OF CONTROLS. k g. Tare Menu. Exit. Print. Units PRINT

Pennsylvania Scale Company Model 400B Battery Powered Digital Indicator Operation & Calibration Manual

SAC / SHC / SHC-CH SERIES

AELP PALLET BEAMS SCALES

MODEL SPS-10. User Manual DIGITAL POSTAL SCALE

PS-IN202 Weighing Indicator User Manual

Operation and Service Manual. METTLER TOLEDO XRM Price Computing Scale.

UWE-1707 SERIES CONTENTS OPERATION MANUAL ELECTRONIC WEIGHING INDICATOR 1. SPECIFICATIONS 2. INSTALLATION

QB Series. Operation Manual. Precision Balance. To be the best by every measure

EDGE. Digital Kitchen Scale. 11lb x 0.1oz 5000g x 1g

BBA-Series Precision Balances

VWR BALANCES. A-Series Balances for High Precision with Advanced Features. B2-Series Balances are Rugged, Affordable, and Reliable

Precision Balance W3200 Series Operating Manual

acaia lunar Operation Manual

Acaia Pearl Operation Manual

VWR BALANCES. A-Series Balances for High Precision with Advanced Features. B2-Series Balances are Rugged, Affordable, and Reliable

SCS3MT080, SCS3MT100, SCS3MT120, SHDHS1500 & SPLS1000 User Manual

Installation / Operator / Service Manual. Bench Scales Revision 6 07/ by Fairbanks Scales Inc. All rights reserved

Digital Kitchen Scale

EC100. Counting Scale. Operations Manual (V1611)

Table of Contents. Laboratory Balances. Instruction Manual - TORBAL AGC Series

1.0 Description. 2.0 Unpacking. 3.0 Installation

Compact Balances. EK-610j EK-6100j. in an Authorized A&D Dealer

OHAUS SCOUT BALANCE SCALE

WUNDER SA.BI.SRL EN USER MANUAL. MULTIFUNCTIONS ELECTRONIC SCALE MOD. W100 LED. User Manual

D-500s Indicator D LED. User Instructions. English Issue September SangR. Page 2. User s manual of Sang D-500s LED

FCS-30/60/150 kg (3 DIFFRENT SCALES) Shipping scale

American Weigh Scales, Inc. AMW-BENCH. D i g i t a l T a b l e t o p S c a l e. User Manual

KITCHEN SCALE OWNER S MANUAL

AGT/SUPER SS ELECTRONIC SINGLE/DUAL DISPLAY WEIGHING/COUNTING SCALE USER MANUAL

Oxford E Series. Instruction Manual

CONTENTS. PRECAUTIONS... 4 PREFACE... 6 OVERALL VIEW... 6 DISPLAY & KEYBOARD... 7 OPERATIONS I. Programming Mode II. Sales Mode...

1. Introduction Page 2. Specifications Page Installation Page Key Functions Page Operations Page 6. Check Weighing Page 6

Visit for discount prices on Acculab Scales SVI SERIES PROFESSIONAL PRECISION INDUSTRIAL SCALE SVI-10A SVI-20B SVI-50C SVI-100E SVI-200F

IGB Series. Operation Manual. Platform Scale. Kg/Lb Specification IMPORTANT

Manual Compact Scale / Balance PCE-BS 300 / 3000

OHAUS Asia-Pacific Dealer Meeting March 23-25, 2010 Hua Hin, Thailand Compact & Counting Scales

STANDARD OPERATING PROCEDURE ACB SERIES ACB-600H PRECISION BALANCE

QC-3265 Checkweigher User s Manual

PLATINUM PRO6000 PROFESSIONAL SERIES DIGITAL COUNTERTOP / PORTABLE BALANCE

User Manual MODEL DIGI SERI DS

Userʼs Guide. 1200g High Precision Scale. 1200g High Precision Scale. Legal for Trade. Includes RS-232 interface port. UG Version 1.

6165 MONEY COUNTING SCALE

Digital Counting Scale C Series Operation Manual

CONTENTS INTRODUCTION 1 INSTALLATION 1 KEYS 3 MAXIMUM DISPLAY & DISPLAY RESOLUTION 4 BATTERY STATUS INDICATION 5 POWER ON SETUP 5

Acaia Lunar Operation Manual

MODEL PS-11 DIGITAL PORTION SCALE

1. INTRODUCTION This manual contains installation, operation and maintenance instructions. Please read the manual completely before using the balance.

WASHDOWN PPC-200: SPLASH-PROOF

Adam Equipment LBK SERIES. (P.N. 9596, Revision D, July 2014)

CONTENTS. 1. Preface Features Technical Specifications Application of Dummy Plate Usage of Connector & Roller...

AL-Series INSTRUCTION MANUAL AL-311 AL-201S. American Weigh Scales, Inc. Analytical Balances American Weigh Scales, Inc. pcs% kgct.

Instruction Manual for. Torbal AGCN Series Balances

PC-150. DIGITAL BENCH SCALE Setup / Operation Manual

INTRODUCTION INSTALLATION

Adam Equipment. Euro January 2003

KW serial. User s guide. Bench Scales UGKW-E0302

Eclipse Analytical Balances

OMEGA SERIES COUNTING SCALE

The ultimate multi-purpose digital scale Ideal for letters, parcels and large boxes

AJ Series. Intelligent-Lab NTEP Centigram Balance. Made in Japan

DMC-688. When Accuracy Counts

AD SERIES SCALEIBALANCE INSTRUCTION MANUAL

Adventurer TM Pro Analytical and Precision Balances

Please read this user manual thoroughly before using the scales to ensure correct usage. Keep a copy of the manual handy for future reference.

Smart Nutrition Scale

BW/BWS Weighing Indicator

Adventurer TM Pro Analytical and Precision Balances

Model Bulk Sampling Scale. User s Manual

PW-II Service Manual PW-II SERVICE MANUAL

DL Series NEWDOLBO OWNER S MANUAL. Simple Weighing Scale 9002-DL

Digital Weight Indicator Setup / Operation Manual

Laboratory Balances. Standard. Option (addit. price) KERN Your DKD Calibration Partner. Your specialist dealer

Totalcomp TLI Indicator. Operation and Maintenance Manual Manual

CONTENTS 1.0 CAUTIONS AND PREPARATION 2.0 DISPLAY AND KEY: 7.0 DEALER S SETTING CAUTIONS PREPARATION DISPLAY

PRECAUTIONS... 4 PREFACE... 6 NAMES AND FUNCTIONS... 6 OPERATIONS... 8

Table of Contents. 3-1 Specifications & Features Front Panel Display Keyboard. 3-3 Rear Panel. 3-4 Power Supply. 4.

Electronic Bench Scales Instruction manual

Calibration. RS 232 and other out puts. Q: Will a standard RS232 cable work with an Ohaus balance?

Transcription:

OCEAN WATERPROOF WEIGHING SCALE USER MANUAL Excell Precision Limited 2006. All rights reserved Worldwide. The information contained herein is the property of Excell Precision Limited and is supplied without liability for errors or omissions. No part may be reproduced or used except as authorised by contract or other written permission. The copyright and the foregoing restriction on reproduction and use extend to all media in which the information may be embodied.

TABLE OF CONTENTS BEFORE USING THE SCALE...2 PREPARING TO USE THE SCALE...2 CHAPTER 1 FEATURES AND SPECIFICATIONS...3 CHAPTER 2 DISPLAY...4 CHAPTER 3 KEYBOARD FUNCTION...5 3-1 Explanation of Keyboard...5 3-2 Basic Function Operation...6 3-2-1 Switching the scale on / Re-zeroing...6 3-2-2 The desired units selection...6 3-2-3 The weight value of the container deduction...6 3-2-4 Net / gross weight value cross-display...6 3-2-5 Counting mode...7 CHAPTER 4 ADVANCED FUNCTION SETTINGS...8 4-1 Auto Power off and Backlight Setting...8 4-2 Hold Function Setting...9 APPENDIX 1 7 SEGMENT DISPLAY CHARACTERS...10 1

BEFORE USING THE SCALE Thank you for purchasing an EXCELL OCEAN Waterproof Weighing Scale. In order to use the scale properly, please read this User Manual carefully before use. If you have a problem concerning the scale, please contact your supplier. 1. Please keep scale in a cool and dry place. Do not store at high temperatures. 2. Do not allow any liquids to come into or contact with the scale. If it is happened, wipe the scale dry with a cloth. 3. Avoid objects impacting with the scale. Do not drop loads onto the scale or subject the weigh pan to any strong shock loads. 4. The load placed on the weigh pan must not exceed the maximum weighing capacity of the scale. 5. If the scale is not going to be used for some time, please clean it and store it in a plastic bag in dry conditions. A desiccant sachet may be included to prevent moisture build up. PREPARING TO USE THE SCALE 1. For accurate weight readings locate the scale on a firm level surface free from vibrations. 2. Avoid operating the scale in direct sunlight or drafts of any kind. 3. Remove any weight that might be on the weigh pan before the scale is switched on and avoid leaving weight on the pan for long periods of time. 4. Once the scale has been switched on, it will go through a LCD display test and then re-zero to be ready for use. 5. The scale requires 15~20 minutes warming up the machine before operation to ensure best accuracy. 6. Please note when symbol appears on the screen, the dry batteries need to be replaced or the recharge the battery. 7. All goods weighed should be placed in the centre of the weigh pan for accurate weighing. The overall dimensions of the goods being weighed should not exceed the dimension of the weigh pan. 2

CHAPTER 1 FEATURES AND SPECIFICATIONS Features: 1/3,000 display Resolution IPX6 waterproof design Auto calibration Large size LCD (25mm) with LED backlight Double over-load protection Includes kilogram (kg), ounce (oz) and pound (lb) weighing units Full range tare; Auto zero tracking; Gravity compensation; Environmental parameter setting Both quick weighing mode and simple counting (pcs) mode available Net/Gross indication; Hold function; Low battery warning; Auto power off With curve-form base and adjustable feet, easy to carry and settle for operation With smooth surface and easy-to-disassemble platter, convenient for maintenance Options: Second display (customer side) Rechargeable battery 6V/5Ah Specification: Model Capacity Division Resolution OCEAN-3 3kg 1g 1/3000 OCEAN-6 6kg 2g 1/3000 OCEAN-15 15kg 5g 1/3000 OCEAN-30 30kg 10g 1/3000 Operation Temperature 0 C ~ 40 C (32 F ~ 104 F) Display LCD, 5 1/2 Digits, 25mm (Height), LED Backlight Dimensions 250 x 300 x 140mm (W x D x H) Platter Size 225 x 195mm Power Supply AC 9V Adaptor or Rechargeable battery 6V/5Ah 3

CHAPTER 2 DISPLAY 1 2 3 4 1 : Tare indication 2 : Zero indication 1 : The 1 st unit indication 2 : The 2 nd unit indication 3 : The 3 rd unit indication 4 : The 4 th unit indication : Low Battery indication. 4

CHAPTER 3 KEYBOARD FUNCTION 3-1 Explanation of Keyboard 1. OFF : The key to switch the scale off. 2. ON ZERO : ON/ZERO key. When the scale is off, press the key to switch it on. When the scale is switched on, with the weigh pan empty, if the display is not showing zero, press this key to zero (balance) the scale. v Zero range: ± 2% of full scale (Standard, OIML & NTEP models), ± 4% of full scale (Sri Lanka model). 3. TARE : TARE key. Press the key to deduct the weight of the container. v The tare key is not functional when the weight value shown on the display is negative or over the full scale capacity. 4. UNITS : Units key. Press the key to select the desired weight units or count units (pcs). 5. NET : Gross weight / Net weight key. GROSS The gross weight = Tare weight + Net weight (The key is ONLY functional in the Tare mode) 5

3-2 Basic Function Operation 3-2-1 Switching the scale on / Re-zeroing ON 1. When the scale is off, press key to turn the scale on. ZERO ON 2. When the scale is on and without any object placed on the weigh pan, press ZERO key to obtain a zero reading. the 2 nd indication shows in the left hand side of the display. 3-2-2 The desired units selection Press the UNITS key to select gram (g), ounce (oz) or pcs, the indication will show in the right hand side of the display. After power off, the scale will memorise the active units. When the scale is powered on again, it displays the previous active units. 3-2-3 The weight value of the container deduction TARE 1. Place the container on the weigh pan. After stable, press key to deduct the weight value of the container. 2. Place the object in the container, the scale will show the net weight value of the object. 3. Remove the container and weighing object, and the display shows the negative weight value of the container. Press TARE key to clear the weight value of the container, and the first indication goes off. v Tare continuously (Press TARE key, when weight is added or deducted on the weigh pan). v Tare value = The full capacity (The scale can be tarred continuously to the full capacity). 3-2-4 Net / gross weight value cross-display 1. In the tare mode, the display shows the 1 st indication on the left hand side. Press key to show the gross weight value, and the indication goes off. NET GROSS NET 2. Press GROSS key again, the display shows the net weight value and the 1 st indication shows again. NET 3. The key is ONLY functional in the tare mode. GROSS 6

3-2-5 Counting mode UNITS 1. Press key to select piece unit (pcs), and enter the counting mode. NET GROSS 2. Press key to select the counting sample size 10, 20, 50, 100, or 200, and the display shows,,,, or 3. Place the samples on the weigh pan, then press UNITS. The display shows. After the weight is stable, the scale shows the quantity of the samples. After the sampling process is complete, put the goods on the weigh pan and the screen shows the quantity of the goods. v The scale memorizes the selected sample quantity, after turning off the scale. The scale will show the same selected sample quantity, when entering the counting mode next time. v If the quantity of the items weighed larger than 65536 (pcs), the display shows the error message. 7

CHAPTER 4 ADVANCED FUNCTION SETTINGS 4-1 Auto Power off and Backlight Setting ON ZERO Switch on the scale, press and GROSS keys together to enter the advance function setting mode. The display shows. NET Auto power-off setting Press the ON/ZERO key to enter a parameter The display shows the last setting Auto power off timer setting Press the ON/ZERO key to enter a parameter. 0 No auto power-off 1 When the scale is idle for 1 minute, the scale automatically switches off 2 When the scale is idle for 2 minutes, the scale automatically switches off Press the TARE key 19 When the scale is idle for 19 minutes, the scale automatically switches off Press the ON/ZERO to enter a parameter key The display shows the last backlight setting Auto backlight setting Press the ON/ZERO key to enter a parameter. ON/ZERO Increment digit (from 0 to 9) TARE Confirm / enter key NET/GROSS Move the cursor to the right on Auto Backlight on off Auto Back light off Automatic power-off function When the weight on weigh pan is less than 10d or remains steady for the set time, the scale will automatically switch off. v Automatic power-off is not functional, when using an ac adaptor as the power source. Therefore, auto power-off is ONLY active, when using dry batteries as the power source. Auto Backlight Function When the weight is over 10d, the backlight is on. After the weight is stable for 10 seconds or when the scale returns to zero, the backlight switches off. 8

4-2 Hold Function Setting Hold function setting LCD displays the last parameter setting Use the ON/ZERO enter a parameter key to Press the TARE key to complete the advance function setting Hold function setting Use the ON/ZERO key to input a parameter Default setting = 0 0 Hold function disabled 1 Peak hold mode 2 Stable hold 1 mode 3 Stable hold 2 mode Back to weighing mode ON/ZERO Increment digit (from 0 to 9) TARE Confirm / enter key NET/GROSS Move the cursor to the right = Hold function disabled. = Peak hold mode The scale shows the maximum weight value detected from the continuously changing weight values. Press any key to exit the hold function. = Stable hold 1 mode After the scale is stable, the display shows the current weight value. Press any key to exit the hold function. = Stable hold 2 mode After the scale is stable, the display shows the current weight value. Re-zero the scale to exit the hold function. v Restart the scale to activate the setting just done. 9

APPENDIX 1 7 SEGMENT DISPLAY CHARACTERS Digit 7 segments letter Alphabet 7 segments letter Alphabet 7 segments letter 0 A N 1 B O 2 C P 3 D Q 4 E R 5 F S 6 G T 7 H U 8 I V 9 J W K X L Y M Z 10