Bright Advance Corporation USER INSTRUCTIONS

Similar documents
Table Of Contents I. Precautions Before Using The Scale

CONTENTS. PRECAUTIONS Introduction Installation... 7

MWP SERIES. High Precision

WUNDER SA.BI.SRL EN USER MANUAL. MULTIFUNCTIONS ELECTRONIC SCALE MOD. W100 LED. User Manual

DWP-98 Series. Counting scale. User s Guide PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE ATTEMPT TO OPERATE THE INSTRUMENT

SCS3MT080, SCS3MT100, SCS3MT120, SHDHS1500 & SPLS1000 User Manual

OCEAN WATERPROOF WEIGHING SCALE USER MANUAL

DWP-PC SERIES PRICE COMPUTING SCALE User s Guide

Trade Approved Version NMI: S520

KW serial. User s guide. Bench Scales UGKW-E0302

IDS-801 Series Compact Bench Counting Scale. User Manual

uline.com OVERVIEW OF CONTROLS CONTROL PANEL CONTROL PANEL PARTS

User Manual. Waterproof Weighing Scale. ELW Plus / ESW Plus ELW Plus Wipower

Multi-Function Smart Indicator User Manual

Table of Contents. 3-1 Specifications & Features Front Panel Display Keyboard. 3-3 Rear Panel. 3-4 Power Supply. 4.

Service Manual for EC-II counting scale

EB300 Weighing Scale Operation Manual

UWE-1707 SERIES CONTENTS OPERATION MANUAL ELECTRONIC WEIGHING INDICATOR 1. SPECIFICATIONS 2. INSTALLATION

NOTE. This is warning & caution mark. This is hazard alert mark. This is useful information mark

MI101 / MI102 / MI102S INDICATOR

Kilotech. KRS SWP Series. Counter-top weighing scale. NTEP (USA) and Measurement Canada approved.

Cautions for Your Safety

D-500s Indicator D LED. User Instructions. English Issue September SangR. Page 2. User s manual of Sang D-500s LED

1. Introduction Page 2. Specifications Page Installation Page Key Functions Page Operations Page 6. Check Weighing Page 6

EHC-WF. User/Technical Manual. Contents subject to change without notice

9. FUNCTION MENU SETTINGS -TION FUNCTION DESCRIPTION DEFAULT. VALUE F0 H-L SEt Lo Set a value for the Low

INTRODUCTION INSTALLATION

PS-IN202 Weighing Indicator User Manual

CONTENTS INTRODUCTION 1 INSTALLATION 1 KEYS 3 MAXIMUM DISPLAY & DISPLAY RESOLUTION 4 BATTERY STATUS INDICATION 5 POWER ON SETUP 5

EXCELL PRECISION CO., LTD.


Analytical balance KERN ABS-N ABJ-NM

Table of Contents. Laboratory Balances. Instruction Manual - TORBAL AGC Series

TWP-W. Weighing Indicator Service Manual

BENCH SCALES FAST COMPETENT RELIABLE DIVERSE. GB KERN Professional measuring.

BW/BWS Weighing Indicator

ES210. Animal & Vet Scale User s Manual (V1611) Anyload Transducer Co. Ltd

TWP series. Weighing Indicator Service Manual

PS-C60K-D. Counting Scale Service Manual

Oxford E Series. Instruction Manual

QUICK START GUIDE PACKAGING. 1 x 220 V/12 VDC 1A mains adapter. Accompanying documentation. 1 x K3 weight indicator

USER S GUIDE. Weighing Indicator. globalindustrial.com. Use of RS232 Port Using Windows for the Printer Driver, Adjust Computer Settings as Follows:

MC Piece Counting Scale

EC100. Counting Scale. Operations Manual (V1611)

GMC-206/215/230 Digital Desktop Weighing Scale Operation Manual

1. On / Off. 2. Initial reset to zero

TRWS series. Waterproof indicator User s guide UGTRWS-E1.1

220,- KERN PFB 11. Precision balances. High resolution precision balance. Concept of easy use. Stable housing. Available with separate second display

Your product specialist s recommendation: High resolution precision balance. Display device can be detached

SAC / SHC / SHC-CH SERIES

Weighing Indicator Service Manual V1.24X

Precision Balance W3200 Series Operating Manual

Counting Scale. HC-3Ki. HC-15Ki HC-6Ki WM+PD

AELP PALLET BEAMS SCALES

Weighing Indicator USER S GUIDE. globalindustrial.com. globalindustrial.com. 11 Harbor Park Drive Port Washington, NY 11050

KERN PFB 11. Precision balances. High resolution precision balance. Concept of easy use. see page 23. Stable housing

805HP. Handheld Digital Weight Indicator Operations Manual (V1612) Anyload Transducer Co. Ltd Website:

BW/BWS/CW/VW series. Bench Scales User s guide UGBW/BWS/C W/VW-E1.17

This document hosted by: Extension Load Cell Cable (OP-02)

COMPLETE MANUAL. WEIGHING INDICATOR TI-1200 and TI-1200-S TI-1200 with rechargeable battery.

EHC-C. User / Technical Manual. Contents subject to change without notice

CONTENTS 1.0 CAUTIONS AND PREPARATION 2.0 DISPLAY AND KEY: 7.0 DEALER S SETTING CAUTIONS PREPARATION DISPLAY

Weighing Indicator M701. Handrail scales. REV: M1, April,05,2014 (v )

805HP. Handheld Digital Weight Indicator Operations Manual (V1612) Anyload Transducer Co. Ltd Website:

Userʼs Guide. 1200g High Precision Scale. 1200g High Precision Scale. Legal for Trade. Includes RS-232 interface port. UG Version 1.

Totalcomp TLI Indicator. Operation and Maintenance Manual Manual

BW/BWS/VW/CW/NTW/NSW. Weighing Indicator

American Weigh Scales H-110. User Manual. H-110 (110lb x 0.05lb) Copyright 2010 American Weigh Scales, Inc. All rights reserved. Rev. 4.

! User Manual Rev. 1

AL-Series INSTRUCTION MANUAL AL-311 AL-201S. American Weigh Scales, Inc. Analytical Balances American Weigh Scales, Inc. pcs% kgct.

21e. Multi-Function Indicator. Operation Manual (Full Version) PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE OPERATING THIS INSTRUMENT

BBA-Series Precision Balances

OMEGA SERIES COUNTING SCALE

CAUTIONS... 4 INTRODUCTION...

American Weigh Scales, Inc. AMW-BENCH. D i g i t a l T a b l e t o p S c a l e. User Manual

User Operation Manual

Warning. Warning. Warning. Pay Attention to Static Electricity. Ask professional personnel to debug, detect. and repair controller.

CONTENTS. 7. User Programming Functions... 26

Adam Equipment. CFC SERIES (P.N. 6164, Revision A3, July 2005) Software revision: V1.04

DC-10. Dual Counting Indicator. Operation Manual (Full Version) PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE OPERATING THIS INSTRUMENT

Instant Moisture Meter for Grains, Seeds, Coffee and other small products PM-650. Operating Manual

MPB SERIES Electronic Balances. r1 v1.09. Operation Manual

805HP. Handheld Digital Weight Indicator User s Manual (v1703) Anyload Transducer Co. Ltd Website:

1. INTRODUCTION This manual contains installation, operation and maintenance instructions. Please read the manual completely before using the balance.

INSTRUCTION MANUAL. Balances. Stable OHAUS. Mode. Units. Setup >O/T< Enter. Print OHAUS >O/T<

EDGE. Digital Kitchen Scale. 11lb x 0.1oz 5000g x 1g

CONTENTS PRECAUTIONS... 3 INSTALLATION... 4 ZERO... 9 TARE PRE-TARE AUTO TARE SELECTION OF WEIGHING UNIT... 16

Explorer Balances Instruction Manual

1.0 Description. 2.0 Unpacking. 3.0 Installation

STANDARD OPERATING PROCEDURE ACB SERIES ACB-600H PRECISION BALANCE

Digital Bench Scale. Revision 1.2 September 14, 2000 Contents subject to change without notice.

OHAUS SCOUT BALANCE SCALE

Multi-Function Indicator. Operation Manual (Full Version) PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE OPERATING THIS INSTRUMENT

TCM2 Series Counting Scale Operation Manual V1.0 Contents Subject to Change without Notice

1. Introduction Specifications Operation Guide Trouble-shooting Note... 13

Adam Equipment. CBC-M SERIES with EC type Approval (P.N. 8226, Revision C7, July 2011) Software rev.: 3.06A & above

PRW series. Bench Scale. User s guide UGPRW-E1.01

Digital Weight Indicator Setup / Operation Manual

STANDARD OPERATING PROCEDURE AA SERIES AA-160 PRECISION BALANCE

BALANCES.COM. Contents

Transcription:

Briht Advance Corporation USER INSTRUCTIONS Weihin Scale

Briht Advance Corporation TABLE OF CONTENTS BEFORE USING THE SCALE2 PREPARING TO USE THE SCALE2 LCD DISPLAY3 KEYBOARD FUNCTION4 OPERATION5 1 DISPLAY BACKLIGHT5 2 ZERO5 3 WEIGHING MODE5 (1) Units Selection5 (2) Totalisin5 I Weiht Totalisin II Clear Totalised Weiht Values III Recall Totalised Weiht Value (3) Deduction of the Container Weiht7 I The weiht of the container is unknown ( Tare )7 II Clear the semi-auto tare7 III Recall the semi-auto tare value7 IV The weiht of the container is known (Pre-set tare)8 V Clear the pre-set tare value8 VI Recall the pre-set tare value8 (4) Check Weihin9 I Pre-set the Low limit value, Hih limit value, and the buzzer operation9 II Pre-set the Low limit value only10 III Hih/OK/Low indication10 IV Recall the check weihin settin10 V Clear the check weihin settins10 4 COUNTING FUNCTION11 (1) Samplin11 (2) Totalisin11 (3) Check Weihin11 CONFIGURATION SETTINGS12 1 CHECK-WEIGHING CONFIGURATION 13 2 RS-232 SETTING 14 3 EXIT CONFIGURATION SETTINGS 15 4 HOLD SETTING 1 RS-232 SERIAL OUTPUT17 RS-232 SERIAL PRINTER OUTPUT (OPTIONAL INTERFACE)17 (1) RS-232 (25 Pin D type) Pin Description17 (2) RS-232 Interface Format17 (3) Data Format18 Weihin Scale 1

Briht Advance Corporation BEFORE USING THE SCALE To enable you to use this scale correctly, we suest that you read this manual carefully 1 Do not use scale in areas with excessive water and don t spray the scale with water when cleanin Remove all water from the scale with a clean dry cloth 2 The load placed on the platform must not exceed the maximum weihin capacity of the scale 3 Keep the scale away from hih temperatures and damp conditions 4 If the scale is not oin to be used for some time, please clean it and store it in a plastic ba in dry conditions A desiccant sachet may be included to prevent moisture build up 5 If the scale is not oin to be used for some time, the internal rechareable battery should be rechared every three months Before usin the scale after a lon period of storae, please ensure that the internal battery is fully chared NOTE: Care should be taken not to leave the internal battery on chare for too lon, as this may decrease the life of battery PREPARING TO USE THE SCALE 1 Locate the scale on a firm level surface free from vibrations for accurate weiht readins 2 Adjust the four levellin feet to set the scale platform level usin the spirit level bubble located on the scale platform frame 3 Avoid operatin the scale in direct sunliht or drafts of any kind 4 Remove any weiht that miht be on the scale platform before the scale is switched on 5 Once the scale has been switched on, it will o throuh a LCD display test and then re-zero to be ready for use The scale requires 15~20 minutes warm up before operation to ensure best accuracy 7 Please note when the symbol is shown on the display, the internal battery needs to be rechared 8 All oods weihed should be placed in the centre of the platform for accurate weihin The footprint of the oods bein weihed should not overhan the edes of the platform Weihin Scale 2

Briht Advance Corporation LCD DISPLAY HIGH 1 2 : Hih Preset Weiht Limit 3 4 5 OK : The rane between Low & Hih Limit Weiht Limit LOW : Low Preset Weiht Limit k lb Pcs : k unit : lb unit : COUNTING mode indicatin the number of pieces 0 : ZERO indication and platform stable confirmation Net : Net Weiht indication : Low Battery indication 1 : () Stable indication 2 : ( PT) Pre-set Tare mode 3 : (M+) Accumulation mode 4 : ( ) Sample Too Small indication 5 : ( ) Piece Weiht Too Small indication Pcs Weihin Scale 3

Briht Advance Corporation KEYBOARD FUNCTION 1 UNITS : Units Key to choose the unit weiht k or lb 2 : Preset Hih & Low Limit 3 ^ / : Data Entry Key, Backliht Key 4 / : Print Key to print the total data ; Confirmation Key 5 : Sample Key to set the unit weiht of sample Pcs M+ : Accumulation Key to add the displayed value into memory 7 R : Re-call accumulated value or preset hih & low limit value or preset tare value 8 CE : Clear Key to delete the existin accumulated values, preset hih & low limit value or preset tare value 9 : this key to enter countin mode 10 : Preset Tare Key PT 11 0 : Zero Key to re-zero the weiht 12 : Tare Key to deduct the container weiht T KEYBOARD SYMBOLS: COUNT SMPL UNITS Pcs UNITS PRE-TATR M+ PST PT M+ ZERO RE-CALL BL PRINT TARE CE 0 T R CE Weihin Scale 4

OPERATION Briht Advance Corporation 1 DISPLAY BACKLIGHT ^ / to choose the display backliht mode : Auto Backliht mode When the weiht is over 10 divisions or any key is pressed, the display backliht will be switched on When the weiht returns to zero (the weiht on platform is less than 10 divisions), the display backliht will switch off after 5 seconds Display backliht is on all the time Display backliht is off 2 ZERO When the weih pan is empty (free of load) and the display is not showin zero, press the key to zero the scale At zero, the 0 indication is on 0 3 WEIGHING MODE (1) Units Selection I UNITS to choose the weihin units and the display will show the k or lb symbol on the top riht of the LCD display II The unit status will be memorized when you turn the machine off (2) Totalisin The totalisin function can be used up to a maximum of 9999 times before it must be reset The totalisin display is limited to diits maximum The scale allows the next totalisin operation, even when the weiht value does not return back to zero The M+ key is functional, when the weiht value chanes by more than 10 d The scale will store the totalised weiht value after the weiht is stable Weihin Scale 5

I Weiht Totalisin Briht Advance Corporation ACTION DISPLAY Place the object onto the scale The display shows the weiht value M+ key The display shows the total number of additions The M+ symbol will flash on the display M+ v The scale can totalise positive or neative weiht but not both at the same time The totalised weiht must be cleared before it is possible to chane positive or neative totalisin mode II Clear Totalised Weiht Values R key followed by pressin CE to clear the totalised weiht values All totals will be lost when the mode is chaned from weihin to countin or vice versa and when the scale is switched off III Recall Totalised Weiht Value R key to display the totalised weiht value and the total number of additions The M+ symbol will flash on the display The scale will return to the weihin mode after 3 seconds v The scale will not display the neative sin - for neative totalised weiht values, but the neative sin - will be printed out (transmitted serially) for each neative weiht and neative totalised weiht Weihin Scale

Briht Advance Corporation (3) Deduction of the Container Weiht I The weiht of the container is unknown ( Tare ) ACTION DISPLAY Place the container onto the scale T key when the weiht is stable The weiht value becomes zero and the (Net) symbol is displayed Net Place the object into the container and the display shows the net weiht value of the object Net II Clear the semi-auto tare When the container is removed from the scale, the display shows the container weiht value with a neative sin off T key to reset the scale to zero, and the (Net) symbol will switch v Multiple tare operation Users can continuously increase or decrease the tare value by pressin the key T v The total tare value (tare value + pre-set tare value) can equal the full capacity of the scale III Recall the semi-auto tare value key followed by pressin The display shows the tare weiht value R T Weihin Scale 7

Briht Advance Corporation IV The weiht of the container is known (Pre-set tare) ACTION DISPLAY DESCRIPTION PT key Use key to enter the weiht value of the container followed by pressin key Net PT The display shows the weiht value of the container with the neative sin and the (Net) symbol flashes on the display The PT symbol indicates the tare function is active Place the object with the container onto the weih pan The display shows the net value of object Net PT V Clear the pre-set tare value key followed by pressin PT, then press CE to clear the R pre-set tare value The scale resets back to zero, and the (Net) symbol and the PT symbol will switch off VI Recall the pre-set tare value key followed by pressin PT The display shows the pre-set tare value R v NOTE: In Tare mode, the Pre-set tare function is not available Weihin Scale 8

(4) Check Weihin Briht Advance Corporation to enter the check weihin function UNITS to abandon the settin and return back to the weihin mode I Pre-set the Low limit value, Hih limit value, and the buzzer operation ^ / key to enter the value required and step to the next diit by pressin the / key ACTION DISPLAY DESCRIPTION key to select the check weihin function key to enter the Low limit value to confirm the settin Set the Hih limit value key to enter the Hih limit value to confirm the settin Χ Χ A Β A 0 = When the weiht is stable the buzzer sounds and the Hih, OK or Low icon is displayed 1 = The Hih, OK or Low icon is displayed irrespective of the stability of the weiht The buzzer sounds only when the weiht is stable Set the buzzer operation key to enter the buzzer operation to confirm the settin The scale returns to the weihin mode 2 = The buzzer sounds and the Hih, OK or Low icon is displayed irrespective of the stability of the weiht B 0 = The buzzer does not sound 1 = The buzzer sounds at the OK status 2 = The buzzer sounds when the weiht of the object is lower or equal to the Low limit value, or hiher than the Hih limit value Weihin Scale 9

Briht Advance Corporation II Pre-set the Low limit value only After completin the Low limit value settin, the display shows key to complete the settin, and the display shows v When users only pre-set the Low limit value, the buzzer settin is fixed at: III Hih/OK/Low indication LOW OK HIGH 10d Low limit value Hih limit value IV Recall the check weihin settin followed by pressin R to recall the Low limit value Then press Then press Then press R R R aain to recall the Hih limit value aain to recall the buzzer settin aain to return the weihin mode V Clear the check weihin settins followed by pressin R, then press CE to clear the Low limit value CE aain to clear the Hih limit value and the buzzer settin Weihin Scale 10

Briht Advance Corporation 4 COUNTING FUNCTION key to enter the countin function UNITS to return back to the weihin mode (1) Samplin ACTION DISPLAY to enter the countin function Pcs Pcs to choose the number of desired sample quantity (10, 20, 50 or 100) Place the sample on the scale and press After the weiht is stable The display shows the sample quantity Pcs Pcs Pcs NOTE: The larer the sample size, the more accurate the unit weiht (The minimum sample weiht = 20d) A sample size of 10 pieces ives a typical count accuracy of 95% A sample size of 50 pieces ives a typical count accuracy of 98% SAMPLE TOO SMALL ( ) Sample is less than 20 divisions UNIT WEIGHT TOO SMALL ( ) Unit weiht is less than 1/5 of a division Pcs Under such conditions, the scale can still work, but may result in lower count accuracy (2) Totalisin Refer to the operation of totalisin in the weihin function on pae 7 (3) Check Weihin Refer to the operation of check weihin function on pae 11 Weihin Scale 11

Briht Advance Corporation CONFIGURATION SETTINGS Switch on the scale While the scale is countin backward to zero, press and hold the display shows the software proram version number: 0 key until Release 0 key, the scale enters the confiuration settin mode is displayed TARE TARE TARE TARE INTERNAL CALIBRATION (LOCKED) INTERNAL CALIBRATION (LOCKED) TARE INTERNAL CALIBRATION (LOCKED) INTERNAL CALIBRATION (LOCKED) TARE CHECK-WEIGHING SETTING RS232 OR SERIAL PRINTER SETTING TARE EXIT FROM CONFIGURATION MODE SHOWS THE INTERNAL VALUE TARE HOLD SETTING TARE INTERNAL CALIBRATION (LOCKED) TARE Weihin Scale 12

Briht Advance Corporation 1 CHECK-WEIGHING CONFIGURATION F8 (Hold) affects access to F4 If F8 is set, access to F4 is denied ^ / or T key to select F4 function the display shows ACTION DISPLAY DESCRIPTION key to select the check weihin function key to enter the Low limit value to confirm the settin Set the Hih limit value key to enter the Hih limit value to confirm the settin Set the buzzer operation key to enter the buzzer operation to confirm the settin Χ Χ A Β A 0 = When the weiht is stable the buzzer sounds and the Hih, OK or Low icon is displayed 1 = The Hih, OK or Low icon is displayed irrespective of the stability of the weiht The buzzer sounds only when the weiht is stable 2 = The buzzer sounds and the Hih, OK or Low icon is displayed irrespective of the stability of the weiht The scale returns to the weihin mode B 0 = The buzzer does not sound 1 = The buzzer sounds at the OK status 2 = The buzzer sounds when the weiht of the object is lower or equal to the lower limit value, or hiher than the upper limit value Weihin Scale 13

Briht Advance Corporation 2 RS-232 SETTING J1 and J3 on the RS-232 interface are connected toether (short), when the RS-232 interface is connected to a computer J2 and J4 on the RS-232 interface are connected toether (short), when the RS-232 interface is connected to a printer ^ / or T keys to select the F5 function the display shows ACTION DISPLAY DESCRIPTION key 0 No transmission 1 Stable transmission Transmission default mode key to set the transmission mode Then press key to confirm the settin Baud rate default settin key to set the baud rate (1200, 2400, 4800 or 900) Then press key to confirm the settin Confiuration complete 2 Continuous transmission 3 to transmit (simple mode) 4 to transmit (complete mode) 5 Stable transmission (totalisin mode) The format is as same as 3 EZ-2 printer mode The format is as same as 4 7 to transmit (EZ-2 printer mode) 8 to transmit The format is the same as 1 & 2 v When choosin EZ-2 printer mode, the Baud rate should be set to 900 bps v Refer to Pae 19~22 for RS-232 data format Weihin Scale 14

Briht Advance Corporation 3 EXIT CONFIGURATION SETTINGS ^ / T or key to select the F function the display shows ACTION DISPLAY key Scale reverts back to normal weihin mode Weihin Scale 15

Briht Advance Corporation 4 HOLD SETTING When the hold function is active, the display will show the maximum weiht on the weih pan the / key to print out the weiht value ^ / or T key to select F8 function the display shows ACTION DISPLAY DESCRIPTION Select one of the hold mode and press to exit = No hold function = With a chanin weiht value, the scale automatically hold the maximum value displayed in any key except the / key to cancel the hold function = When the weiht is stable, the scale hold the displayed value in any key except the key to cancel the hold function / = When the weiht is stable, the scale will hold the displayed value When the scale returns to zero (the weiht is less than 10 divisions), the hold function will be released Weihin Scale 1

Briht Advance Corporation RS-232 SERIAL OUTPUT RS-232 SERIAL PRINTER OUTPUT (OPTIONAL INTERFACE) (1) RS-232 (25 Pin D type) Pin Description J1 - J3 SHORT ; J2 - J4 OPEN (default settin) Pin 2 RXD Pin 3 TXD Pin 7 GND J2 - J4 SHORT ; J1 - J2 OPEN Pin 2 TXD Pin 3 RXD Pin 7 GND (2) RS-232 Interface Format I Mode : EIA-RS232 C s UART sinal II Format : 1 Baud rate: 1200, 2400, 4800 or 900 bps 2 Data bits: 8 BITS 3 Parity bit: none 4 Stop bits: 1 BIT 5 Code: ASCII Start bit Data bits Stop bit Weihin Scale 17

(3) Data Format Briht Advance Corporation Stable transmission / Continuous transmission / to transmit 1 2 3 4 5 7 8 9 10 11 12 13 14 15 1 17 18 k/lb HEAD 1, HEAD 2, DATA UNIT C LF HEAD 1 ( 2 BYTES ) HEAD 2 ( 2 BYTES ) OL - Overload, Under load TR - TARE Mode ST - Display is Stable NT - NET Mode US - Display is Unstable GS - GROSS Mode DATA (8 or 9 BYTES) 2D ( HEX ) = ( MINUS ) 2E ( HEX ) = ( DECIMAL POINT ) UNIT ( 2, 3 or 4 BYTES ) k = B ( HEX ) ; 7 ( HEX ) lb = C ( HEX ) ; 2 ( HEX ) Transmission example: 1 With the weiht stable, a tare set and a ross weiht value of + 087 k the data strin is shown below: S T, G S, + 0 8 7 k 0D 0A HEAD 1, HEAD 2, DATA UNIT C LF 2 With the weiht unstable, net weiht the weiht value -158lb the data strin is shown below: U S, N T, - 1 5 8 l b 0D 0A HEAD 1, HEAD 2, DATA UNIT C LF Weihin Scale 18

Briht Advance Corporation key to transmit (simple mode) S/N WT/UNIT ( k / lb ) - - - - - - - - - - - - - - 0001 10000 E key or M+ key 0002 10000 E key or M+ key 0003 10000 E key or M+ key 0004 10000 E key or M+ key 0005 10000 E key or M+ key - - - - - - - - - - - - - - 0005 50000 E key 2 times to print out the total Stable transmission (totalisin mode) S/N WT/UNIT ( k / lb ) - - - - - - - - - - - - - - 0001 10000 E scale stable, transmittin 0002 10000 E scale stable, transmittin 0003 10000 E scale stable, transmittin 0004 10000 E scale stable, transmittin 0005 10000 E scale stable, transmittin - - - - - - - - - - - - - - 0005 50000 E key 2 times to print out the total EZ-2 printer mode, press to transmit (Baud rate must be set at 900 bps) Only prints out the weiht value The proportion of the printed font Heiht : Width = 3:2 +1000 k Weihin Scale 19

Briht Advance Corporation EZ-2 printin mode (Baud rate must be set at 900bps) key to transmit (complete mode) TICKET NO 0001 G 1000k T 0000k PT 0000k N 1000k E key or M+ key (Blank line x 3) TICKET NO 0002 G 1000k T 0000k PT 0000k N 1000k E key or M+ key (Blank line x 3) TICKET NO 0003 G 1000k T 0000k PT 0000k N 1000k E key or M+ key (Blank line x 3) TOTAL NUMBER OF TICKETS 0003 TOTAL NET 3000 k E key twice to prin tout the total (Blank line x 3) <Remarks> : G = GROSS T = TARE PT = PRE-TARE N = NET Weihin Scale 20