Contact information: Aanderaa Data Instruments AS PO BOX 34, Slåtthaug 5851 Bergen, NORWAY. Visiting address: Nesttunbrekken Nesttun, Norway

Similar documents
Contact information: Aanderaa Data Instruments AS PO BOX 34, Slåtthaug 5851 Bergen, NORWAY TEL: FAX:

AANDERAA. DATALOGGERS 3634 and 3660

TD 303 OPERATING MANUAL SEAGUARD II Platform May 2016 SEAGUARDII PLATFORM

ETOR-4. Ethernet/Serial Gateway USER MANUAL

ETOR-4 Ethernet/Serial Gateway ETOR-4. Ethernet/Serial Gateway USER MANUAL

TD 314 OPERATING MANUAL In-line Doppler Current Sensor 5800/5810 September /5800R/5800RR/5810/5810E

1 st Edition June st Edition October rd Edition February th Edition January th Edition January 2011

KERN YKI-02 Version /2014 GB

KERN YKI-02 Version /2016 GB

Contact information: Aanderaa Data Instruments AS PO BOX 34, Slåtthaug 5851 Bergen, NORWAY TEL: FAX:

APPENDIX B SERIAL I/O MODULE INSTALLATION / OPERATION WHEN USING T&D VER. 5.2 OR 5.3

Instruction manual CIU Prime type 880 (CIU858 emulation)

Ethernet-232 User s Manual

Frontline Test System

Solar-Log WEB "Classic 2nd Edition" Manual Installation

Flex Series User Guide

UPort 2000 Series User s Manual

GPRS/SerialGateway. GPRS/Serial Gateway. User Manual

B-EV4 Series Printer Setting Tool Operating Specification

SOFTWARE MANUAL PHOENIX AC DRIVE DX & EX DRIVEMASTER

SmartLink Configuration Manual

F1760 Firmware Installation Instructions on Devices with Firmware prior to V

Xpert / XLite GPRS232 Serial Interface Block USERS MANUAL. Part No Rev. 3.3 July 27, 2009

International Headquarters. European Headquarters

User Manual for VE GSM Modem

International Headquarters. European Headquarters

MxDS1 CNC Data Shuttle

1. Supplied Items. 2. Connecting the DTS SKT. Input side. Input Side

STEP X - Name of Step QUICK START GUIDE SP385A-R3, SP390A-R3 USB TO RS CONVERTER 24/7 TECHNICAL SUPPORT AT OR VISIT BLACKBOX.

Technical User Manual Avisaro 4.0 Product Series

CPT-COM-U Card. TTL Serial USB Isolated Interface Board. Technical Brief

ICC. Metasys N2 Master Driver Manual INDUSTRIAL CONTROL COMMUNICATIONS, INC Industrial Control Communications, Inc.

Temperature-Humidity Sensor Configuration Tool Rev. A 1/25/

3.1 I-7560 Pin Assignment and Specifications: Introduction

Remote Display User Manual

RS 232 Interface. RS 232 is the Serial interface on the PC. Three major wires for the Serial interface: Transmit Pin 2 Receive Pin 3

SMG-1100/6100 User s Manual

S u p p l e m e n t TQS3 MODBUS. Description of product modification with MODBUS RTU. 31. March 2008 w w w. p a p o u c h.

Multi-Port Controller

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter

GEM-10 GPRS/Modbus Gateway User Manual. Rev /2012

Mobile Printer CMP-40 Utility Manual (V1.76)

GSM manual and Software User Guide

VISY-X. Technical Documentation. Cinterion MC 55 i. Edition: Version: 1 Article no.:

MAGUIRE PRODUCTS, INC. 11 Crozerville Road Aston, PA tel: fax:

CPM Series. Control Port Manager. User's Guide. Models CPM-1600 and CPM-800

SCI Testers and Remote Communication: Using HyperTerminal

POS / ATM / Access Control

Message Display Operator Panel. UCT-33/36 Industrial Terminal. Manual 32.00

User's Manual PLC09 Modbus Converter for PAL-AT Leak Detection System

PowerVision Plus 1.3

Pass-Through Function

Metadata Plugins Access Control, License Plate Recognition and Point of Sale Solutions

Parallel to Serial and Serial to Parallel Converter CE Model 232SPS2 Documentation Number 232SPS2-3903m

Wireless M-Bus Suite for Panasonic Evaluation Boards. Quick Start Guide

Simplify The Complexity. Orion Analyzer User Manual Ver. 0.4

Unique Micro Design. Advanced Thinking Products. Model 164 Quad Coupler User Manual

TOSVERT VF-AS3. Trace Tool PCT003Z-E. Instruction Manual

Serial console tool. To open the Serial console tool, select Serial console from the Tools drop-down menu in the toolbar.

Integrating the MDT SMART Link-485 Sensor Application Note #32

MB40 & MB45 MODBUS TCP/IP Gateway Handbook

Product Manual. 8-Port RS-232 USB to Serial Adapter Data Control Box. Coolgear, Inc. Version 1.1 September 2017 Model Number: USB-8COM

MGate MB3000 Modbus Gateway User Manual

IDEA. User s Guide. Part No IDE02 Issue 1-0, April 1995 Printed in U.S.A. (183)

This document contains excepts from the MS-DMT User Guide for MARS

1. System Topology Required Equipment and Components Hardware Equipment Software Equipment... 6

HARDENED ROOM SENSOR USER MANUAL SAD120 CPO55 E 1

Installation and Programming Manual. Niobrara Research & Development Corporation P.O. Box 3418 Joplin, MO USA

MGate MB3000 Modbus Gateway User s Manual

DatraxRF Spread Spectrum Wireless Modem

TECHNICAL BULLETIN [ 1 / 8 ]

EEG ComCC 1250m Modem Data Multiplexer

Firmware Release ( 32-Bit-WINDOWS version )

Remote Display User Manual

D0 DCM Module Setup Direct

XN120 PC Pro Guide Getting Started Rev 1.2 (January 2007)

Doug Fleenor Design, Inc. RS-232 to DMX512 Interface, 2 Generation. March 8, 2010 (Software V1.2)

TOSVERT VF-AS1/PS1. Trace Tool PCT001Z-E Instruction Manual

Sartorius Comparator. Interface Description for the CC Model Series

installation manual SALES AND ADMINISTRATION (toll free)

This is the procedure to use the Clone module as a serial converter: To enable communication you must set the following parameters in the drive.

DAQ Electronics, Inc 262B Old New Brunswick Road, Piscataway, NJ

AdaptaScan Reader to a PLC-5 Using RS-232/ASCII Protocol with the 2760 RB Module and the 2760-SFC1 and -SFC2 Protocol Cartridge

FERGUSON BEAUREGARD. RTU-5000 Configurator User Manual

USB TO RS-232/RS-422/RS-485 ADAPTER

POS / ATM / Access Control

Fluke Metrology Software

TRAINING GUIDE LEVEL 3 MODBUS WRITE IMPORT COMMAND

Embedded Serial-IP SOC CXT32SI1X NeChip Family

BLE232: Manual Copyright 2014 taskit GmbH

MULTICOM. Clarity Hardware. Code/Rev.: M110/80A Date: 8/15/2018. Fax: Petrzilkova 2583/ Prague 5

Documentation No. Product Version Page

Metasys Integrator United Power Application

SERIAL COMMUNICATION for Delta VFD drives

Modbus Protocol For TGP03 / THP03

Operating Instructions Sartorius

GE-SNP Protocol Serial Driver

ICP PANEL-TEC PEX3000 II

NetBiter Serial Server User Manual

Flasher ATE. Production Programmer. Getting Started. Document: AN08007 Manual Version: 1.0 Revision: 2 Date: January 9, 2018

Transcription:

Page 2 January 2009 TD271 AADI Real-Time Communication 1 st Edition 21 February 2008 2 nd Edition 13 May 2008 3 rd Edition 6 June 2008 4 th Edition 15 January 2009 Copyright: Aanderaa Data Instruments AS Contact information: Aanderaa Data Instruments AS PO BOX 34, Slåtthaug 5851 Bergen, NORWAY Visiting address: Nesttunbrekken 97 5221 Nesttun, Norway TEL: +47 55 604800 FAX: +47 55 604801 E-MAIL: info@aadi.no WEB: http://www.aadi.no AANDERAA DATA INSTRUMENTS

January 2009 TD271 AADI Real-Time Communication Page 3 Table of Contents INTRODUCTION... 4 Purpose and scope...4 Document Overview...4 Applicable Documents...4 CHAPTER 1 The AADI Real-Time Communication System... 5 CHAPTER 2 Connection between the AADI Real-Time device and a PC... 7 2.1 Connection between the SEAGUARD Platform and a PC...7 2.2 Connection between an AADI Smart Sensor and a PC...8 CHAPTER 3 AADI Real-Time Collector... 9 CHAPTER 4 Real-Time Output Protocol... 11 4.1 Message Types...11 4.1.1 Non-polled data... 11 4.1.2 Response to Control Messages... 11 4.1.3 Notification Messages... 11 CHAPTER 5 Real-Time Control Protocol... 13 5.1 Control Message Types...13 5.1.1 Operating... 13 5.1.2 Reconfiguring... 13 Reliable solutions

Page 4 January 2009 TD271 AADI Real-Time Communication INTRODUCTION Purpose and scope The purpose of this document is to provide an overview of the AADI Real-Time Communication System, and to give a brief introduction to its different components. Document Overview CHAPTER 1 CHAPTER 2 CHAPTER 3 CHAPTER 4 CHAPTER 5 Gives a short introduction to the system. Describes how to connect an AADI SEAGUARD instrument to a PC. Describes the AADI Real-Time Collector application. Describes the AADI Real-Time Output Protocol. Describes the AADI Real-Time Control Protocol. Applicable Documents TD262a TD267a TD267b TD268 TD272 TD278 SEAGUARD Platform Operating Manual AADI Real-Time Output Protocol AADI Real-Time Output Protocol Diagram View AADI Real-Time Collector Users Manual AADI Real-Time Control Protocol Diagram View AADI Real-Time Programming Reference AANDERAA DATA INSTRUMENTS

January 2009 TD271 AADI Real-Time Communication Page 5 CHAPTER 1 The AADI Real-Time Communication System The AADI Real-Time Communication System is designed to provide our customers and system integrators (and our own Engineering department) with powerful and efficient tools for data collection and control of our latest generation of oceanographic instruments. The AADI Real-Time enabled devices like the SEAGUARD Platform, and the AADI Smart sensors form the basis of this system. These devices may be configured to transmit data autonomously (non-polled mode). They may also respond to control commands for remote operation and configuration. AADI Real-Time Collector is an application that must be installed on a PC that is to connect to the AADI Real-Time enabled devices. The AADI Real-Time Collector provides the necessary tools to connect to one or more devices, receive their transmitted data and by powerful interfaces and methods provide easy and efficient access to these data from higher level applications like display programs, databases etc. Refer to Figure 1-1 for an overview of the AADI Real-Time Communication System. Figure 1-1 The AADI Real-Time Communication System. Reliable solutions

Page 6 January 2009 TD271 AADI Real-Time Communication The protocols that are used for communication and data transfer to and from the AADI Real- Time enabled devices are: The AADI Real-Time Output Protocol, which covers all messages sent from the device. This includes data messages, respones to control messages and notifications. The AADI Real-Time Control Protocol, which covers all messages sent to the device for remote control and configuration. The AADI Real-Time System also includes some utilities and examples to provide users with Quick Start applications. These utilities may even in certain cases be sufficient in a simple system. However, they are provided as examples only and may not be maintained at the same level as the other modules. The AADI Real-Time Communication System is further described in the following chapters of this document and in the referred applicable documents, refer page 4. CHAPTER 2 describes how to connect the AADI SEAGUARD instrument to an RS422 port on a PC. CHAPTER 3 describes the AADI Real-Time Collector. This application provides the user with tools to set up any number of device connections, monitor the quality of the connections, receive incoming data, and operate and configure the device. AADI Real- Time Collector also provides a programming interface which enables other applications to retrieve data from any of the connected devices. CHAPTER 4 describes the AADI Real-Time Output Protocol used to transmit data from AADI devices in real-time. Messages are formatted using XML. CHAPTER 5 describes the AADI Real-Time Control Protocol used to send control messages to a connected device. As in the output protocol, all messages are XMLformatted. AANDERAA DATA INSTRUMENTS

January 2009 TD271 AADI Real-Time Communication Page 7 CHAPTER 2 Connection between the AADI Real-Time device and a PC The AADI Real-Time enabled device is connected to the PC using a serial port. Often, it will be a direct cable connection but it may also be a radio modem connection, a GPRS connection or other communication channels providing a point-to-point serial connection with a physical or virtual COM-port at the PC end and a physical serial port at the device end. 2.1 Connection between the SEAGUARD Platform and a PC The SEAGUARD Platform output port is an RS422 serial port. The communication settings are given in Table 2-1. Table 2-1 Communication settings. Parameter SEAGUARD Platform Configuration Values AADI Real-Time Collector Requirements: Baud Rate 2400-115200 No requirements Data Bits 7,8 8 Stop Bits 1, 1.5, 2 1 Parity None, Even, Odd None Flow Control None, Xon/Xoff Xon/Xoff 10-pin plug for connection to the SEAGUARD Electrical Terminal Serial connection plug USB plug Connection plug to AC/DC adapter 3786 Figure 2-1 Cable 4573. Reliable solutions

Page 8 January 2009 TD271 AADI Real-Time Communication For a direct cable connection between the SEAGUARD Platform and your PC, use AADI cable 4573 (Figure 2-1). If your PC does not come with a RS422 Port, you must install a RS422 to RS232 Converter between the standard cable and the PC. Note! Some converters may require the RTS signal to be set from the computer to accept incoming data. IMPORTANT! The maximum RS422 cable length depends on the cable properties and baudrate. 1000 m is the general recommended maximum length. 2.2 Connection between an AADI Smart Sensor and a PC Future versions of AADI Smart Sensors will become AADI Real-Time enabled devices. Connection details will be described when the sensor are available. AANDERAA DATA INSTRUMENTS

January 2009 TD271 AADI Real-Time Communication Page 9 CHAPTER 3 AADI Real-Time Collector Note! Refer the AADI Real-Time Collector Users Manual, TD268, for a complete description of the application. The AADI Real-Time Collector is a background application running on a PC. Its main task is to: Receive data from devices that uses the AADI Real-Time Output Protocol. Receive and convert data from devices that uses certain custom data formats. Provide an interface for client applications that utilize the data, e.g. a display program. The application has dialogs for: Setting up a connection between the transmitting device and the receiver PC. Displaying status information for all of the defined connections. Controlling the device recorder. Changing the device configuration. The AADI Real-Time Collector can: Receive data from multiple devices. Serve multiple client applications through the provided.net programming interface. Store data to files. The purpose of the AADI Real-Time Collector is not to display data. Display programs and other client applications must be arranged by the user. A couple of getting started applications with source code are provided to show the application designer how to connect and obtain data from the AADI Real-Time Collector. Reliable solutions

Page 10 January 2009 TD271 AADI Real-Time Communication AADI Real-Time Collector basics Connection setup and status dialogs User application interfaces AADI.Realtime.Collector.ClientInterface.dll Methods to Subscribe to a device Interface for Data Device Control Status info Methods for high level readout of data and other info from the device Device communication AADI Real-Time Control Panel The AADI Real-Time Control Panel allows a client to control the device Recorder and to change the device configuration remotely. AANDERAA DATA INSTRUMENTS

January 2009 TD271 AADI Real-Time Communication Page 11 CHAPTER 4 Real-Time Output Protocol The AADI Real-Time Output Protocol is used to transmit data from AADI devices in Real- Time. The data messages from the device are framed to secure precise synchronisation. The frame includes a CRC16 value which provides integrity control. Refer to Appendix 1 in TD 267a AADI Real-Time Output Protocol for a detailed description of the frame format. The data is delivered as an XML formatted message. XML is a markup language designed to describe data and to focus on what data is (http://w3schools.com/xml/default.asp). XML is an ASCII based format and as such human readable, although XML messages are generally read and interpreted by computer applications. The precise definition of the message format is given by the XML schema file RTOutSchema.xsd, which is available for download on our web site www.aanderaa.no. Customers can register to get a user name and password necessary to gain access to e.g. user manuals, technical notes and software. Please contact info@aadi.no for guidance. Modern development tools such as Microsoft Visual Studio or Altova XML Spy provide several ways for quick and easy access to data in XML format using the defining schema file. 4.1 Message Types There are three main scenarios in which data can be received from a connected device, as explained below. The output from the device is always formatted using the AADI Real-Time Output Protocol, regardless of the content. 4.1.1 Non-polled data A device can be set up to automatically transmit data recordings at regular intervals, i.e. nonpolled mode. Each message contains all necessary information to identify the measured parameters and to be fully traceable down to every physical unit involved in the measurement. The message content automatically adapts to the current configuration of the device. 4.1.2 Response to Control Messages If the connected device supports it, the AADI Real-Time Control Protocol can be used to control a deployed device (refer TD272). This includes starting and stopping the recorder, and changing the device configuration. Any response from the device will be formatted using the AADI Real- Time Output Protocol, but will usually just contain relevant return values rather than recording data. 4.1.3 Notification Messages A notification message is an asynchronous message sent by the device to notify about an event on the device. This notification message contains notification data, specifying the event that Reliable solutions

Page 12 January 2009 TD271 AADI Real-Time Communication triggered the message, but also associated data records, configuration and sensor information may be included. AANDERAA DATA INSTRUMENTS

January 2009 TD271 AADI Real-Time Communication Page 13 CHAPTER 5 Real-Time Control Protocol The AADI Real-Time Control Protocol is used to issue basic control messages to AADI devices in Real-Time. The control messages to the device are framed in the same way as for the AADI Real-Time Output Protocol; refer Appendix 1 in TD267a. The messages are XML formatted like the Output Protocol. The precise definition of the control format is given by the XML schema file RTControlSchema.xsd, which is available for download on our web site www.aanderaa.no. Customers can register to get a user name and password necessary to gain access to e.g. user manuals, technical notes and software. Please contact info@aadi.no for guidance. 5.1 Control Message Types There are two main scenarios in which a connected device is operated through the Control Protocol, refer chapter 5.1.1 and chapter 5.1.2. 5.1.1 Operating A device can be controlled through a set of control commands. These include start and stop of the data recording. The command for stating the data recording may include arguments for the start time and the interval at which data are recorded and transmitted to the receiving system. 5.1.2 Reconfiguring A device can be reconfigured through a set of control commands where the device setup is downloaded from the device for modification and subsequent uploaded to activate the new settings. Reliable solutions