BLACK BOX. G.703 NTU w/10baset MARCH 2006 MT330A NETWORK SERVICES

Similar documents
4K 2-PORT KVM SWITCH, USB C, DISPLAYPORT

USB Director/USB RS-232 Hub

USER MANUAL ME890A-R2 CATX DB9 LINE DRIVER 24/7 TECHNICAL SUPPORT AT OR VISIT BLACKBOX.COM RJ45 RJ45 5 VDC DB9-RS232

USB TO RS-232 OR RS-422/485 ISOLATED CONVERTER

Copyright Black Box Corporation. All rights reserved.

ServSwitch DT DVI Pro

MicroNTU G.703 X.21 SEPTEMBER 1997 MT241A. MicroNTU G.703-X.21 CUSTOMER SUPPORT INFORMATION

Copyright Black Box Corporation. All rights reserved.

DISPLAYPORT KVM DESKTOP SWITCHES

Relay Output Card PCI 32 Outputs 32 Outputs/Kit

Express Ethernet Switches

Remote Port USB 2.0 -CAT5

DISPLAYPORT KVM DESKTOP SWITCHES

MARCH 2011 LB400A-R2 High Speed Ethernet Extender

Network Video Codec. Network VideoCodec CAMERA FEBRUARY 2001 AC700A CUSTOMER SUPPORT INFORMATION

Model AC2000A DVI, Audio, RS-232 Extender with EDID Management

Autosensing ISDN Matrix Switch

Remote Port Wireless USB 2.0 User Guide

Copyright Black Box Corporation. All rights reserved.

Extend DVI-D video and stereo audio up to 1.5 kilometers over a strand of single-mode fiber or distribute DVI-D and stereo audio to 32 displays.

Transmit USB 2.0 device signals up to 328 feet (100 m) over CAT5 cable, and power the extender locally or remotely.

HDMI 2.0 SPLITTER 1X4

Relay/Digital I/O Card-16

Copyright Black Box Corporation. All rights reserved.

Extend video and USB up to 328 feet (100 m) over CAT5e or better cable.

Connect up to four DB9 serial devices to a USB port.

4-PORT USB 2.0 FIBER EXTENDER

Connect one or two DB9 serial devices to a USB port.

Line Share 120B FEBRUARY 1997 FX121A. Phone Line Manager 120B CUSTOMER SUPPORT INFORMATION

4-Port Single-Mode Fiber Optic USB 2.0 Extender

User Manual. Industrial Ethernet Extender for Extreme Temperatures - 10/100, 1-Port LB323A. Customer Support Information

2-Wire Short-Range DSL Line Driver (HDSL with 10BASE-T)

4-Port Multimode Fiber Optic USB 2.0 Extender

Easily extend SuperSpeed USB 3.0 signals up to 330 feet (100 meters) over fiber.

4-Port RS-232 PCI Serial Adapter 4-Port RS-232 HS PCI Serial Adapter

Linc Up Plus NT Linc Up Plus ATT Linc Up Plus RLM

Provides one channel for Ethernet over existing voice-grade twisted-pair copper

Extend Ethernet with full-duplex transmission up to 10.8 Mbps over two pairs of copper.

Send up to four bidirectional data streams simultaneously over a single pair

ServSwitch DT Series USB/DVI/Audio KVM Switches

Copyright Black Box Corporation. All rights reserved.

BLACK BOX. Easily extend both HDMI video and USB 2.0. up to 330 feet (100 m). ServSwitch KVM Extender, HDMI and USB 2.0 over CATx ACU2500A

Break the 16-foot (5-m) USB distance barrier. This. up to 328 feet (100 meters) from a computer over CAT5 cabling.

Pure Home Networking Boxes

Featuring enhanced biometric security with twofactor authentication, providing the perfect blend of security and simplicity.

twister 10MBPS MEDIA CONVERTERS

2-Port CAT5 USB 2.0 Extender with Local Power

PCI Plus Adapter RS-232 HS Serial PCI

Copyright Black Box Corporation. All rights reserved.

Portable USB Modem Quick Start Guide

User Manual. Industrial Ethernet Extender, 10/100, 1-Port LB320A. Customer Support Information

USB Director/4-Port Hub

Expand existing, leased line, polled networks without adding computer ports or communications links. Four- and eight-port models available.

Express Ethernet Switch

Single Channel RS-232/530/422/485/20mA Current Loop Interface

Easily extend USB 2.0 signals over an IP network or directly over a CATx link.

Control your 4-post rack- or cabinet-mounted USB or PS/2 server with the compact, ServTray.

Compact Codirectional G.703 Converters

Extend HDMI signals over CATx cable.

JUNE 2000 SW613A SW613A-K

RS-232/422/485 Single-Port PCI Card, Opto-Isolated

2-Wire Short-Range DSL Line Driver (HDSL with V.35) (HDSL with X.21)

USB Directors RS-232

User Manual. Chapter VS-2000-DEC. H.264 Decoder. Contact Information

Featuring enhanced biometric security with two-factor authentication, providing the perfect blend of security and simplicity.

DSLAM Chassis and Software

Clever Code-Operated Switch

ServSwitch Universal Extender

User s Manual. Gigabit Media Converter. Link 10/100/1000BASE-T to 100-/1000-Mbps SFP fiber connections. LGC220AE. Customer Support Information

Cable Inspector Cable Tester User Manual CICT. Customer Support Information

Pwr. Pwr. Pwr. 4/16 Pwr 2. Rem.F. Rem.F. Rem.F. Token Tx. Link. Link. Link. Rx Al. Rx Al. Link. RX Al RemF. Link. Link. Rx Al. Rx Al.

Set up and manage a large, multichannel digital signage network that spans many locations.

HDMI Audio Extractor with EDID Mgmt

External ADSL USB Modem Users Manual

Copyright Black Box Corporation. All rights reserved.

Voice Conferencing System

Copyright Black Box Corporation. All rights reserved.

ServSwitch Wizard USB Extender

2.4 GHz Wireless Remote Unit with Hookswitch

SCSI Fiber Optic Extenders

4- and 8-Line Caller ID

Store, transport, charge, and sync ipads.

THE SERVSWITCH FAMILY

Manage and control up to 16 DVI and USB servers from your desktop.

Dual Port RS-232/422/485 Serial Interface

Voice Pro JANUARY 2001 FX700A FX701A FX702A CUSTOMER SUPPORT INFORMATION

Chapter. HD View. AC3000A-R2 AC3016A-R2 Series

NOVEMBER 2000 SW625A-R2 SW626A-R2. Doc. No Rev. B

Compact modules which allow you to place your high resolution video display and peripherals up to 492 feet from your system.

User Manual v icompel Deployment Manager (IDM) v Customer Support Information

Secure Site Remote Console Port & Power Manager User s Guide

Simplify and save. Use a wired or wireless network to extend HD-quality digital signage

Code Operated Switch II 4-Port Expansion Board

DKM TC KM SWITCH W/ HID PORTS

Display standard single- or dual-link DVI input across four output monitors.

Provides access to the data streams passing through a high-speed network device and a switch.

Black Box Tech Support: FREE! Live. 24/7. Great tech support is just 60 seconds away at or blackbox.com.

Outlet Managed PDU JULY 2010 MPSH8-S20-120V MPSH8-S V MPSH8-D20-120V MPSH8-D V MPSH16-D20-120V MPSH16-D V

This Web Smart switch provides sixteen 10-/100-/1000-Mbps ports.

Broadband Router MARCH 2003 LR9601A CUSTOMER SUPPORT INFORMATION

Transcription:

BLACK BOX NETWORK SERVICES MARCH 2006 MT330A G.703 NTU w/10baset G.703 NTU w/10baset Link E1 10BT Status TM CUSTOMER Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX SUPPORT FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 INFORMATION Mail order: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018 Web site: www.blackbox.com E-mail: info@blackbox.com

CE NOTICE The CE symbol on your Black Box equipment indicates that it is in compliance with the Electromagnetic Compatibility (EMC) directive and the Low Voltage Directive (LVD) of the European Union (EU). A Certificate of Compliance is available by contacting Technical Support. RADIO AND TV INTERFERENCE The Multi-Rate Ethernet Extender generates and uses radio frequency energy, and if not installed and used properly-that is, in strict accordance with the manufacturer s instructions-may cause interference to radio and television reception. The Multi-Rate Ethernet Extender has been tested and found to comply with the limits for a Class A computing device in accordance with specifications in Subpart B of Part 15 of FCC rules, which are designed to provide reasonable protection from such interference in a commercial installation. However, there is no guarantee that interference will not occur in a particular installation. If the Ethernet Extender does cause interference to radio or television reception, which can be determined by disconnecting the unit, the user is encouraged to try to correct the interference by one or more of the following measures: moving the computing equipment away from the receiver, re-orienting the receiving antenna and/or plugging the receiving equipment into a different AC outlet (such that the computing equipment and receiver are on different branches). 2

FCC PART 68 The MT330A is not intended to be connected to the public telephone network. Caution TRADEMARKS USED IN THIS MANUAL All applied-for and registered trademarks are the property of their respective owners. NORMAS OFICIALES MEXICANAS (NOM) ELECTRICAL SAFETY STATEMENT Instrucciones De Seguridad 1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado. 2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura. 3. Todas las advertencias en el aparato eléctrico y en sus instrucciones de operación deben ser respetadas. 4. Todas las instrucciones de operación y uso deben ser seguidas. 5. El aparato eléctrico no deberá ser usado cerca del agua por ejemplo, cerca de la tina de baño, lavabo, sótano mojado o cerca de una alberca, etc. 6. El aparato eléctrico debe ser usado únicamente con carritos o pedestales que sean recomendados por el fabricante. 7. El aparato eléctrico debe ser montado a la pared o al techo sólo como sea recomendado por el fabricante. 8. Servicio El usuario no debe intentar dar servicio al equipo eléctrico más allá a lo descrito en las instrucciones de operación. Todo otro servicio deberá ser referido a personal de servicio calificado. 9. El aparato eléctrico debe ser situado de tal manera que su posición no interfiera su uso. La colocación del aparato eléctrico sobre una cama, sofá, alfombra o superficie similar puede bloquea la ventilación, no se debe colocar en libreros o gabinetes que impidan el flujo de aire por los orificios de ventilación. 10. El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor como radiadores, registros de calor, estufas u otros aparatos (incluyendo amplificadores) que producen calor. 3

11. El aparato eléctrico deberá ser connectado a una fuente de poder sólo del tipo descrito en el instructivo de operación, o como se indique en el aparato. 12. Precaución debe ser tomada de tal manera que la tierra fisica y la polarización del equipo no sea eliminada. 13. Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos colocados sobre o contra ellos, poniendo particular atención a los contactos y receptáculos donde salen del aparato. 14. El equipo eléctrico debe ser limpiado únicamente de acuerdo a las recomendaciones del fabricante. 15. En caso de existir, una antena externa deberá ser localizada lejos de las lineas de energia. 16. El cable de corriente deberá ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo. 17. Cuidado debe ser tomado de tal manera que objectos liquidos no sean derramados sobre la cubierta u orificios de ventilación. 18. Servicio por personal calificado deberá ser provisto cuando: A. El cable de poder o el contacto ha sido dañado; u B. Objectos han caído o líquido ha sido derramado dentro del aparato; o C. El aparato ha sido expuesto a la lluvia; o D. El aparato parece no operar normalmente o muestra un cambio en su desempeño; o E. El aparato ha sido tirado o su cubierta ha sido dañada. 4

CONTENTS CE Notice... 2 Radio and TV Interference... 2 FCC Part 68... 3 Trademarks Used In This Manual... 3 Normas Oficiales Mexicanas (NOM) Electrical Safety Statement... 3 1. General Information...7 1.1 Features...7 1.2 Description... 7 2. PPP Operational Background... 8 2.3 Applications... 8 3. Configuration... 10 3.4 DIP Switch Configurations... 10 3.4.1 Switch S1 settings... 11 3.4.2 SW1-1 Line Coding: HDB3 (default)... 11 4. Installation... 13 4.5 Connecting to the G.703 Network and Ethernet LAN... 13 4.5.3 Connecting Dual Coaxial Cable (75 ohm) to the G.703 Network... 14 4.5.4 Connecting the Twisted Pair (120 ohm) to the G.703 Network... 15 4.5.5 Connecting the 10Base-T Ethernet port to a PC (DTE)... 15 4.5.6 Connecting the 10Base-T Ethernet Port to a Hub... 16 4.5.7 Power Connection... 16 5. Operation... 17 5.6 Power-up... 17 5.7 LED Status Monitors... 17 5.8 Operating Line Loopback (LL)... 19 A. G.703 Specifications... 20 A.1 Network Data Rate...20 A.2 Network Connector...20 A.3 Nominal Impedance...20 A.4 Line Coding...20 5

A.5 Line Framing...20 A.6 Clocking...20 A.7 Distance...20 B. Ethernet 10Base-T Specifications... 21 B.8 DTE Interface...21 B.9 DTE Data Rates...21 B.10 LAN Connection...21 B.11 Protocol...21 B.12 MAC Address Table Size...21 B.13 MAC Address Aging...21 B.14 Frame Buffer...21 B.15 Frame Latency...21 B.16 Diagnostics...21 B.17 Indicators...21 B.18 Configuration...21 B.19 Power Supply...22 B.20 Humidity...22 B.21 Temperature...22 B.22 Dimensions...22 6

1. General Information G.703 NTU W/10BASET Thank you for your purchase of this Black Box product. If any questions arise during installation or use of the unit, contact Black Box Tech Support at (724) 746-5500. 1.1 Features Terminates G.703 E1 service Available in low-cost standalone or rack-mountable versions 2.048 Mbps data rate 10Base-T Ethernet bridge PPP (Point to Point Protocol, RFC 1661) with Bridge Control Protocol (RFC 1638) 75-ohm dual coax and 120-ohm twisted-pair G.703 connections Line loopback diagnostics Internal and G.703 network timing CE marked 100 240 VAC Conforms to ONP requirement CTR 12 for connection to international Telecom networks 1.2 Description The MT330A receives clear channel E1/G.703 (2.048-Mbps) data from the telco's digital data network. The MT330A terminates the G.703 telco interface and converts the data for transmission to a user-oriented 10Base-T (802.3) Ethernet interface. The Ethernet (MT330A) supports an integrated 10Base-T (802.3) Ethernet port with transparent bridging capability for IP, IPX, DECnet, NetBIOS and other layer-3 protocols. The MT330A attaches to the LAN and intelligently bridges data traffic to the large central site router through the telco's leased line network. The MT330A supports PPP (RFC 1661) and BCP (RFC 1638). The MT330A is a 10Base-T bridge that operates over G.703 lines. It uses MAC learning and forwarding to provide seamless LAN-to-LAN connectivity. As a result, corporate enterprises can connect their servers to a pair of NTUs and automatically forward data packets that are meant for the remote network. Local packets are filtered and passed only to the local LAN. 7

2. PPP Operational Background PPP is a protocol used for multi-plexed transport over a point-to-point link. PPP operates on all full duplex media, and is a symmetric peer-to-peer protocol, which can be divided into the following main components: A standard method to encapsulate datagrams over serial links A Link Control Protocol (LCP) to establish, configure, and test the data-link connection A family of Network Control Protocols (NCPs) to establish and configure different network layer protocols In order to establish communications over a point-to-point link, each end of the PPP link must first announce its capabilities and agree on the parameters of the link s operation. This exchange is facilitated through LCP Configure-Request packets. Once the link has been established and optional facilities have been negotiated, PPP will attempt to establish a network protocol. PPP will use Network Control Protocol (NCP) to choose and configure one or more network layer protocols. Once each of the network layer protocols have been configured, datagrams from the established network layer protocol can be sent over the link. The link will remain configured for these communications until explicit LCP or NCP packets close the link down, or until some external event occurs. The PPP Bridging Control Protocol (BCP), defined in RFC 1638, configures and enables/disables the bridge protocol on both ends of the point-to-point link. BCP uses the same packet exchange mechanism as the Link Control Protocol (LCP). BCP is a Network Control Protocol of PPP, bridge packets may not be exchanged until PPP has reached the network layer protocol phase. 2.3 Applications In situations where a routed network requires connectivity to a remote Ethernet network, the interface on a router can be configured as a PPP IP Half Bridge. The WAN line to the remote bridge functions as a Virtual Ethernet interface, effectively extending the routers WAN port connection to the remote network. The bridge device sends bridge packets (BPDU s) to the router s WAN interface. The router will receive the layer three address information and will forward these packets based on its IP address. 8

MT330A MT331A Ethernet LAN Power Ethernet TX Line Made in the USA RX E1 Power Interface Made in the USA Line Router Internet Customer s Site Service Provider s Network Figure 1. Router with serial interface, configured as PPP Half Bridge. Figure 1 shows a typical router with a serial interface configured as a PPP Half Bridge. The router serial interface connects to the WAN via a MT311A (V.35) E1 NTU and to the remote MT330A with support for PPP bridging. The MT330A functions as a node on the remote Ethernet network. The serial interface on the router will have an IP address on the same Ethernet subnet as the bridge. For example, the customer site is assigned the addresses 192.168.1.0/24 through 192.168.1.1/24. The address 192.168.1.1/24 is also the default gateway for the remote network. The above settings remove any routing/forwarding intelligence from the MT330A. The associated router configuration will set serial interface (s0) to accommodate half bridging for the above example.! interface s0 ppp bridge ip ip address 192.168.1.1 255.255.255.0! Authentication is optional under PPP. In a point-to-point leased-line link, incoming customer facilities are usually fixed in nature, therefore authentication is generally not required. Some networking systems do not define network numbers in packets sent out over a network. If a packet does not have a specific destination network number, a router will assume that the packet is set up for the local segment and will not forward it to any other sub-network. However, in cases where two devices need to communicate over the wide-area, bridging can be used to transport nonroutable protocols. 9

3. Configuration The MT330A features configuration capability via hardware DIP switches. This section describes all possible DIP switch configurations of the MT330A. 3.4 DIP Switch Configurations The MT330A has an internal DIP switch that enables configuration for a wide range of applications. The DIP switch is accessed from the underside. Figure 2 shows the location of the DIP switches on the bottom of the printed circuit board. Rear ON S1 OFF Front Figure 2. Underside of MT330A, showing location of DIP switches The DIP switches can be configured as either ON or OFF. Figure 3 shows the orientation of the DIP switches with respect to ON/OFF positions. Figure 3. Close-up view of configuration switches 10

3.4.8 SWITCH S1 SETTINGS Table 1 shows the settings for DIP switch S1-1 thru S1-8. Table 1: Switch S1 settings Switch Description Setting S1-1 Line Coding Off = HDB3 On = AMI S1-2 Line Loopback (toward E1 line) Note The MT330A, when in line loopback mode, will loop the network line and return any trafic received on the E1 line to the sending device at the remote end. Off = LLB disabled On = LLB enabled S1-3 Reserved Off = Default S1-4 Reserved Off = Default S1-5 Reserved Off = Default S1-6/S1-7 Clocking Switch 1-6 On On Off Off Switch 1-7 On Off On Off S1-8 Reserved Off = Default Network Internal (default) Reserved Network 3.4.9 SW1-1 LINE CODING: HDB3 (DEFAULT) Use Switch SW1-1 to control the Network Line Coding options. Set these options to be the same as the Line Coding given to you by your Service Provider. If you are using two MT330As together as short range modems, set both units to HDB3. SW1-1 Off On Line Encoding HDB3 AMI 11

Options: HDB3, AMI HDB3. In this line coding, the transmitter substitutes a deliberate bipolar violation when excessive zeros in the data stream are detected. The receiver recognizes these special violations and decodes them as zeros. This method enables the network to meet minimum pulse density requirements. Unless AMI is required in your application, HDB3 should be used whenever possible. AMI. Alternate Mark Inversion defines a pulse as a "mark, a binary one, as opposed to a zero. In an E1 network connection, signals are transmitted as a sequence of ones and zeros. Ones are sent as pulses, and zeros are sent as spaces, i.e., no pulse. Every other pulse is inverted from the previous pulse in polarity, so that the signal can be effectively transmitted. This means, however, that a long sequence of zeros in the data stream will cause problems, since the NTU receiving the signal relies on the signal to recover the 2.048 Mbps clock. Note If you must use AMI, you should ensure that the data terminal equipment connected to the unit provides a minimally acceptable pulse density. For this reason, there are advantages to using HDB3 instead. AMI coding does not inherently account for ones density. To meet this requirement, the user should ensure that the data inherently meets pulse density requirements. 12

4. Installation Once the MT330A is properly configured, it is ready to connect to the G.703 interface, to the Ethernet port, and to the power source. This section describes how to make these connections. 4.5 Connecting to the G.703 Network and Ethernet LAN This section describes installing the G.703 (75-ohm and 120-ohm), Ethernet LAN, and power connections. Refer to the following to detemine which installation procedures you will use: The 75-ohm dual-coax female BNCs (TXand RX) are used for connecting to a 75-ohm dual coax G.703 network interface. If your G.703 network terminates via dual coaxial cables, refer to section Connecting Dual Coaxial Cable (75 ohm) to the G.703 Network on page 14 The 120-ohm RJ-48C jack is used for connecting to a 120-ohm twisted-pair G.703 network interface. If your G.703 network terminates with a RJ-48C, refer to section Connecting the Twisted Pair (120 ohm) to the G.703 Network on page 15. The Ethernet 10Base-T port is configured as DTE (Data Terminal Equipment). If the MT330A is to connect to another DTE device such as a 10Base-T network interface card in a PC, refer to Connecting the 10Base-T Ethernet port to a PC (DTE) on page 15. Otherwise, refer to Connecting the 10Base-T Ethernet Port to a Hub on page 16. Refer to Power Connection on page 16 to connect the MT330A to a 100 240 VAC source or to a 36 60 VDC DC-to-DC adapter. 13

Made in the USA TX RX Power Ethernet Line Ethernet Power Figure 4. MT330A rear panel Line (120 ohm) RX (75 ohm) TX (75 ohm) 4.5.10 CONNECTING DUAL COAXIAL CABLE (75 OHM) TO THE G.703 NETWORK Refer to Figure 4 to make the proper connections. Note The outer conductor of the coax cables are isolated from system earth ground. When using the 75-ohm interface, jumper straps JP2, JP5, JP6, and JP7 must be installed over the jumpers. The jumpers are located next to the BNC connectors. Do the following to configure the jumpers: 1. Open the case by inserting a screwdriver into the slots and twist the screwdriver head slightly. The top half of the case will separate from the lower half of the case. Take caution not to damage any of the PC board mounted components 2. Open the case and install jumper straps for JP2, JP5, JP6, and JP7. 14

4.5.11 CONNECTING THE TWISTED PAIR (120 OHM) TO THE G.703 NETWORK Refer to the pinout and signals chart in Figure 5 to connect the 120-ohm G.703 network channel. RJ-45 Cable (8-Wire) G.703 NETWORK SIGNAL MT330A SIGNAL PIN# 5 4 RX+ RX- TX+ TX- TX+ TX- RX+ RX- 1 2 Shield Shield (No Connection) 8 (No Connection) 7 (No Connection) 6 (TX+) 5 (TX-) 4 (No Connection) 3 (RX-) 2 (RX+) 1 8 7 6 5 4 3 2 1 Shield Shield 3 6 Figure 5. G.703 120-ohm connection. 4.5.12 CONNECTING THE 10BASE-T ETHERNET PORT TO A PC (DTE) To connect the MT330A to another DTE device such as a 10Base-T network interface card, construct a 10Base-T crossover cable and connect the wires as shown in Figure 6 below and Figure 7 on page 16. 1 2 3 4 5 6 7 8 1 TD+ (data output from 2707/I) 2 TD- (data output from 2707/I) 3 RD+ (data input to 2707/I) 4 (no connection) 5 (no connection) 6 RD- (data input to 2707/I) 7 (no connection) 8 (no connection) Figure 6. Connecting the 10Base-T Ethernet Port to a PC 15

10Base-T Port RJ-45 Pin No. 1 (TD+) 2 (TD-) 3 (RD+) 6 (RD-) 10Base-T DTE RJ-45 Pin No. 1 (TD+) 2 (TD-) 3 (RD+) 6 (RD-) Figure 7. 10Base-T cross-over cable connection 4.5.13 CONNECTING THE 10BASE-T ETHERNET PORT TO A HUB The 10Base-T interface is configured as DTE (data terminal equipment), just like a 10Base-T network interface card in a PC. Therefore, it expects to connect to a 10Base-T Hub using a straight-through RJ-45 cable. Refer to Figure 8 below and Figure 6 on page 15 to construct a cable to connect the 10 Base-T interface to a 10Base-T hub. 10Base-T Port RJ-45 Pin No. 1 (TD+) 2 (TD-) 3 (RD+) 6 (RD-) 10Base-T Hub RJ-45 Pin No. 1 (RD+) 2 (RD-) 3 (TD+) 6 (TD-) Figure 8. Connecting the 10Base-T Ethernet port to a hub 4.5.14 POWER CONNECTION The MT330A uses a 5VDC, 2A universal input 100 240VAC, power supply (center pin is +5V). The universal input power supply has a male IEC-320 power entry connector. This power supply connects to the MT330A by means of a barrel jack on the rear panel. Many international power cords are available for the universal power supply. Note The MT330A powers up as soon as it is plugged into an AC outlet there is no power switch. 16

5. Operation When the MT330A has been properly configured and installed, it should operate transparently. This section describes power-up, LED status monitors, and the built-in loopback test modes. 5.6 Power-up Before applying power to the MT330A, please review section Power Connection on page 16 to verify that the unit is properly connected to the appropriate power source. 5.7 LED Status Monitors The MT330A features six front panel LEDs that monitor connections on the G.703 and 10Base-T links, signaling, error and test modes. Figure 9 shows the front panel location of each LED. Table 2 on page 18 lists descriptions of each LED. G.703 NTU w/10baset E1 Link 10BT Status TM 10BT Link E1 Link Figure 9. MT330A front panel Status TM 17

Table 2: LED descriptions LED Description E1 Link (Active Green) Solid green (On) indicates that the end to end E1 Link is up, signifying that the link is active. The E1 Link LED is Off when the link is down. 10BT Link (Active Green) Solid green indicates that the 10Base-T Ethernet interface has detected a valid SQE heartbeat, signifying a valid 10Base-T connection. Status Blinks yellow from one to eleven times to indicate system status. Each pulse pattern is separated by a 2 second off period. Greater pulse patterns have higher priority (buffer saturation has greater priority than an empty MAC table). Valid system statuses are: 1 pulse system status is okay 2 pulses no MAC entries in the MAC Address Table 3 pulses Clear to Send (CTS) or Carrier Detect (DCD) from base unit are not asserted 4 pulses IM1/I buffer is saturated 5 pulses WAN receive frame(s) too large 6 pulses WAN receive frame(s) not octet aligned 7 pulses WAN receive frame(s) aborted 8 pulses Detected WAN receive frame(s) with CRC 9 pulses Detected LAN receive frame(s) too large 10 pulses Detected LAN receive frame(s) not octet aligned 11 pulses Detected LAN receive frame(s) with bad CRC TM (Active Yellow) Solid Yellow indicates an Active Test Mode. 18

5.8 Operating Line Loopback (LL) The Line Loopback (LL) test checks the operation of the local MT330A, and is performed separately on each unit. G.703 NTU MT330A 2 Mbps G.703 Network Clock/ Data Clock/ Data Cable Span Network Clocking Data MT310A Ethernet Device Figure 10. Line loopback for a network termination application To perform an LL test, set DIP switch S1-2 to On. The TM LED will be lit while the unit is in loopback test mode. 19

A. G.703 Specifications A.1 Network Data Rate 2.048 Mbps A.2 Network Connector RJ-48C/Dual Coax BNC A.3 Nominal Impedance 75/120 ohm A.4 Line Coding Selectable AMI or HDB3 A.5 Line Framing G.703 (Unframed) A.6 Clocking Internal or Network (Receive Recover) A.7 Distance Maximum 6,000 ft (1.6 km) On 24 AWG cable 20

B. Ethernet 10Base-T Specifications G.703 NTU W/10BASET B.8 DTE Interface 10Base-T on RJ-45F B.9 DTE Data Rates 10 Mbps B.10 LAN Connection RJ-45, 10Base-T, 802.3 Ethernet B.11 Protocol PPP (RFC 1661) with Bridging Control (RFC 1638) B.12 MAC Address Table Size 4096 entries B.13 MAC Address Aging MAC addresses deleted after 8 minutes of inactivity B.14 Frame Buffer 512 Frames B.15 Frame Latency 1 frame B.16 Diagnostics Line Loopback B.17 Indicators E-1 Link, 10Base-T Link, Ethernet Status, Test Mode B.18 Configuration 8-Position DIP Switch 21

B.19 Power Supply 5 VDC external power supply 100 240VAC, 50 60Hz, 0.4A B.20 Humidity Up to 90% non-condensing B.21 Temperature 0 50 C (32 122 F) B.22 Dimensions 3.5L x 2.1W x 0.78H in.(9.0l x 5.3W x 2.0H cm) 22

Notes 23

BLACK BOX NETWORK SERVICES Copyright 2006. Black Box Corporation. All rights reserved. 1000 Park Drive Lawrence, PA 15055-1018 724-746-5500 Fax 724-746-0746