UNIGATE UNIGATE CM CM GATEWAY SERIES. CAN/CANopen TO ALL FIELDBUSES AND INDUSTRIAL ETHERNET. Easy installation. Norm compliant.

Similar documents
The intelligent solution

UNIGATE CL CL. Protocol Converter. A solution for all devices with a serial interface. Easy installation. Norm compliant. Ready-to-use.

UNIGATE CL. Protocol Converter. A solution for all devices with a serial interface. Easy installation. Norm compliant. Ready-to-use.

UNIGATE UNIGATE ALL-IN-ONE BUS NODE 32 DIL. Norm compliant. Certified. Programmable. Designed & manufactured in Germany. READY-TO-INSTALL for MPI

FLEXIBLE GATEWAYS FOR INDUSTRIAL COMMUNICATION

UNIGATE CL THE RESULT MUST AGREE BUS-TECHNOLOGY MADE BY DEUTSCHMANN! A solution for all devices with serial interface

Deutschmann Automation,

Integrate the Fieldbus into your device without much development effort involved! All-in-one single bus node for:

CompactCom. Compact communication modules designed to connect automation devices to industrial networks. Connecting Devices

Fieldbus slave modules w/o I/Os

INpact. PCIe interfaces for industrial Ethernet and fieldbus communication

Structure and Function

Firmware-Download-Tool (FDT) Firmware Update for UNIGATE devices

CANopen IO X2 Fact sheet

CANopen IO X1 Fact sheet

NEW with M.2. Format. INpact. PCIe interfaces for industrial Ethernet and fieldbus communication

Profibus-DPV1 Set in IP67 TI-BL67-DPV1-6

CANopen IO X4 Fact sheet

Controllers CECC Key features

. PC cards for all common fieldbus. systems Industrial Ethernet switches. . EtherCAT junctions and media converters in IP 20 and IP 67 ratings

Expansion Module for I/O Communication BL Ident RFID Module for Connecting 2 Read/Write Heads (HF/UHF) BL20-2RFID-S

PC network connectivity

IP67 IP20. Controllers Open Flexible Compact SPEEDWAY. Programmable. Fieldbus Couplers. Programmable. Fieldbus Controllers

DATA TRANSMISSION PHOTOELECTRIC SENSORS. For contact-free, optical free-space data transmission.

Quick Start Guide PN/CAN-Gateway. Version. 1 en. from FW

CAN 300 PRO, Communication Module

User Manual Gateway component for EtherNet/IP

Industrial 2-port RS422/485 Modbus Gateway

Profibus Gateway 3E V Technical Bulletin

Data sheet CPU 315SB/DPM (315-2AG12)

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

Data sheet CPU 315SN/NET (315-4NE12)

Data sheet CPU 315SN/NET (315-4NE12)

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

Data sheet SLIO CPU 015PN (015-CEFPR01)

Instruction manual EPL-Router

NETL ink gateways. Ethernet gateways WLAN gateways High-speed USB gateways

Programmable Set for Simple I/O Communication via PROFIBUS-DP in IP67 TI-BL67-PG-DP-S-8

ETHERNET/MFC 010 Technical Datasheet

hipecs-cio55 CANopen I/O module with 4 analog inputs

Description Developerkit UNIGATE IC AB

PAS 300, PROFIBUS Slave Interface Module

Programmable Set for Simple I/O Communication via Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-S-6

Data sheet CPU 315SN/PN ECO (315-4PN33)

Kit for Simple I/O Communication via Ethernet Modbus/TCP/ EtherNet/IP / PROFINET in IP67 TI-BL67-EN-S-8

BL67 electronic module 8 configurable digital channels, PNP, channel diagnostics, 0.5 A BL67-8XSG-PD

Ver. 01. FnIO S-Series. Integrated Systems for the Speed and Quality

Set for EtherCAT in IP20 TI-BL20-E-EC-S-8

Data sheet CPU 015PN (015-CEFPR00)

Programmable Set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Trajexia motion controller

Industrial Ethernet Comparison for Motion Control Applications

Data sheet CPU 315SB/DPM (315-2AG12)

Data sheet VIPA CPU M13C (M13-CCF0000)

Remote I/O Product Specification

Control block CPX-CM-HPP

hipecs-cio100 CANopen I/O module with 16/16 digital I/O

Profinet Set in IP20 TI-BL20-E-PN-4

hipecs-cio52 CANopen I/O module with 4 analog outputs

Data sheet CPU 015PN (015-CEFPR01)

Remote I/O Product Specification

COMTRAXX COM465DP. Condition Monitor with integrated gateway for the connection of Bender devices to PROFIBUS DP and Ethernet TCP/IP networks

Industrial 1-port RS422/485 Modbus Gateway IMG-110T

MC800 Universal Motion Controller

LMC058LF42 compact base - 42 I/O - 24 V DC supply

TB20. DISTRIBUTED FIELDBUS I/O SYSTEM

Instruction manual Universal Fieldbus-Gateway UNIGATE CL - Profinet

BMKC Controller for Parabolic Trough application without encoder, 8 In 8 Out 4 AI

Fieldbus Gateway Type ME43

PG AC Modbus TCP to LonWorks Protocol Converter

Motor controllers CMMO-ST

Versions. Q.station Q.station T. Q.station D. Q.station DT x x

User manual Gateway component Sercos

hipecs-cio56 CANopen I/O module with PT100/1000 inputs

Programmable Set for Ethenet/IP in IP67 TI-BL67-PG-EIP-2

Compact PLC for STEP7 from Siemens PLC-CPU for STEP7 from Siemens Order no. Type VIPA 214-1BA02 CPU 214 VIPA 214-1BC02 CPU 214C VIPA 215-1BA02

GMA200-MT/-MW. Annex of Instruction Manual. Configuration instruction for Fieldbus-Gateways GMA200-MW GMA200-MT. Profibus- Gateway.

DIS-2 series Decentralised servo drive

CODESYS 3 Programmable Gateway for the BL67 I/O System Multiprotocol Ethernet gateway for PROFINET, EtherNet/IP and Modbus TCP BL67-PG-EN-V3

Instruction Manual Power Distribution System SVS16-PN-XX

AC 800M for Compact Product Suite Outline of all modules

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision

Control blocks CPX-CEC- -V3

Accessories Modular bus covers CANopen

Release Notes. Flexi Soft. Gateways Release Notes. The modular safety controller that cleverly incorporates advantages

SBPC-21-PB FifeNet to Profibus Gateway

Q.brixx station 101. Base Unit with Test Controller. Most important features:

WTX120. Legal-for-trade industrial weighing terminal. Special features. Data sheet

PLIN-LWL Optical Coupler for LIN Data Transmission. User Manual. Document version ( )

CODESYS 3 Programmable Gateway for the BL20 I/O System Multiprotocol Ethernet Gateway for PROFINET, EtherNet/IP and Modbus TCP BL20-PG-EN-V3

Q Series - Q.station 101 Test Controller

Fieldbus BC (CANopen), BP (PROFIBUS DP), EH (EtherCAT), EW (POWERLINK), EI (EtherNet/IP), EP (PROFINET IRT)

Industrial 1-port RS422/485 Modbus Gateway

Data sheet VIPA CPU 115DP (115-6BL22)

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors)

Modular controllers CECX

On-Machine Modular I/O

DIS-2 series Decentralised servo drive

PCAN-PC/104-Plus Quad Four-Channel CAN Interface for PC/104-Plus. User Manual. Document version ( )

Welcome to the Future of Industrial Communication. Introducing the netx Family of Controllers by Hilscher

Transcription:

UNIGATE GATEWAY SERIES UNIGATE CM CM Easy installation Norm compliant Ready-to-use Configurable Designed & manufactured in Germany THE INTELLIGENT SOLUTION FOR: ETHERNET TCP/IP CAN/CANopen TO ALL FIELDBUSES AND INDUSTRIAL ETHERNET Protocol Converter Embedded Solutions Gateways

The intelligent solution UNIGATE CM UNIGATE CM - Easily configurable, ready-to-use CAN Gateways The UNIGATE CM Gateways connect CAN/CANopen-Participants to all Fieldbus- and Industrial Ethernet systems that are supported by Deutschmann. With the Deutschmann developed software WINGATE, the reliable components can be quickly and easily configured and immediately be put into operation. The compact IP20 module with dimensions of 23 mm x 115 mm x 100 mm can be easily mounted on the DIN rail. Besides RS232, RS485 and RS422 standard interfaces, the UNIGATE CM CANopen Gateway has an additional CAN/CANopen interface with Mini-Master functionality. Hence, the gateways can connect both CANopen networks and individual CANopen devices into higher-level networks. Adaptation of the device-firmware is not necessary. After configuration of the parameters, the gateway is immediately ready for communication. The adjustable values are context-sensitive displayed, dependent on the selected function parameters. Furthermore, the module can be very flexibly programmed with the Deutschmann developed script language. UNIGATE CM Detail view of the application side CAN/CANopen interface RS232, RS422, RS485 UNIGATE CM Overview Same mechanical design of all bus versions Space-saving housing Wide voltage range Brand labeling own logo own article description Pre-configuration, import your own script Neutral packaging Own front panel designed for your CI Own housing color On request as for all gateways and protocol converters from Deutschmann the Option I/O 8 is available, with which eight digital I/Os (24 V) can be configured both via the configuration software and by script. Application CAN Layer 2 CANopen Deutschmann optionally supplies the product pre-configured to customer specification, in different housing colors and with or without the customer logo. WINGATE (Configuration) Script update 485/422 232 CAN for example: Fieldbus Advantage Deutschmann This speaks for UNIGATE CM Configuration Available for the most fieldbus and Industrial Ethernet versions CANopen, RS232, RS485- and RS422 interfaces are on Board Same design on the application-side in all bus versions The fieldbus or Ethernet side meets the standards, respectively the standard market models. Built-in isolation on the bus side Configuration of the module via configuration tool WINGATE Free programming with Protocol Developer (Deutschmann Script language) No adjustment of the device firmware needed Modern, slim, DIN rail Same Dimensions in all bus variants Brand labeling, pre-configured according to the customer Wide voltage range from 10 to 33 VDC Option I/O 8 available Function UNIGATE CM Power The UNIGATE CM contains an additional CAN/CANopen interface. The data for CAN is exchanged via configurable protocols. The data exchange for CANopen is handled via CANopen mapping. Furthermore the CANopen interface contains a Master functionality, with which connected slaves can be set e.g. to Operational mode.

UNIGATE CM - Fieldbus Configuration tool WINGATE Overview of possible applications Layer 2 (11/29Bit Identifier) Configuration tool WINGATE WINGATE is a configuration software for the Deutschmann UNIGATE series. The implementation of the CAN/CANopen onto the industrial network is configured with WINGATE. Advantage WINGATE Comfortable configuration Consistency for each bus Additional fieldbus mechanism Upon delivery the UNIGATE CM is pre-configured and set to Layer 2 11Bit. Easy configuration The UNIGATE CM has transport protocols for CAN and a Mapping for CANopen. These can be configured quickly and conveniently using the WINGATE configuration software. Master/Slave ETHERNET TCP/IP The UNIGATE CM connects your CAN/CANopen participants to a fieldbus or Industrial Ethernet. Example for UNIGATE CM-PBDPV1

Configuration tool WINGATE The UNIGATE CM also has a Master functionality. With the CANopen mapping available for CANopen, the UNIGATE CM can be configured as Master or Slave. In addition to mapping COB-IDs, other parameter such as SDO Object Mapping, Node Guarde Mapping, Emergency Data Mapping, Node Guarding and Node control are also available. Easy configuration Example for UNIGATE CM-PBDPV1 The following transport protocols are available for CAN Layer 2 (11/29Bit Identifier): Layer 2 11Bit Universal (L2 11Bit) Universal (L2 11Bit) with COB-ID used Universal (L2 11/29Bit) Universal (L2 11/29Bit) with COB-ID used L2 11Bit (Tgl+FBlen) These transport protocols support CAN 2.0A (11Bit Identifier) or CAN 2.0B (11/29Bit Identifier). Depending on the selected transport protocol, COB-IDs which are to be processed, can be configured. Not needed COB-IDs are filtered. Example for UNIGATE CM-PBDPV1

Protocol Developer Protocol Developer Protocol Developer - Flexibility via Deutschmann Script language More complex applications, which cannot be presented via a pure configuration can be programmed via the Deutschmann Script language. The Protocol Developer is a free tool for generation of the script. It is easy to use and specifically optimized to the bus communication. The user only needs to process the data of the bus and barely has to look after the special characteristics of the fieldbus. The Protocol Developer supports a variety of functions to fit the received or to send data into the right form. Mathematics- or memory processing commands are known from other Script languages and are easy to understand implemented, even for laymen. Also the neatly arranged selection of examples enables a quick introduction to laymen. Another highlight is the included debug functionality. The common functionalities such as Single-step, running and stopping on breakpoint are available. Great emphasis is put on data security. You can activate special error detection routines on request. The script programming gives you a flexible possibility to solve your communication task. On both sides, i.e., on the application-side and on the bus side, data can be edited, converted and arranged. Comfortable script commands Wide range of functions Marketable protocols are included as a script command Quick induction What exactly is a script? A script is a sequence of commands executed in a given order. A command is always a small, firmly outlined task. The script language also knows commands that control the program flow in the script, which is why you can assemble even complex processes with these simple commands. Command groups overview Script example in the Protocol Developer Declarations Flow Control Math Communication Device Control Bus Specific variable declaration Subfunction calls, jumps, branches Mathematical functions, data conversions Send and receive data Set and read parameters. For example the baud rate for the serial interface. bus-specific values

Technical overview for the Fieldbus side CANopen Complete CANopen-Slave-interface Max. 32 TPDO and max. 32 RPDO process data objetcs Baud rate 10kbit/s to 1 Mbit/s Isolated CANopen interface with 9-pin. D-Sub connector CANopen peer-to-peer messaging Generic EDS file EtherNet/IP 2Port EtherNet/IP adapter function Max. 512 byte input- and 512 byte output data Baud rate 10 or 100 Mbit/s Isolated EtherNet interface with 2x RJ45 connector IT functions: Web server, FTP Server PROFIBUS DPV1 Complete PROFIBUS-DP slave interface Max. 244 Byte input- and 244 output data, max. 488 Byte total PROFIBUS address adjustable via rotary switch Automatical Baud rate recognition (9600 bit/s 12 Mbit/s) Isolated PROFIBUS interface with 9-pin. D-sub connector General specifications Application-side CM: CAN and CANopen; RS232, RS485, RS422 Baud rate: 110 Baud to 520 kbaud resp. 625KBaud (depending on device version) with serial, 10/100 MBit/s with Ethernet 16K Script memory Operating voltage: 10,5 bis 31,6 Volt DeviceNet Complete DeviceNet interface Max. 255 Byte input- and 255 Byte output data Baud rate 125-500 kbit/s Isolated DeviceNet interface with 5pin. terminal connection DeviceNet functions: I/O Slave messaging, polling Fast Ethernet (TCP/IP) Complete Fast Ethernet Slave interface Max. 1024 Byte input- and 1024 Byte output data Baud rate 10 or 100 Mbit/s Isolated Fast Ethernet interface with 1x RJ45 connector IT-functions: Web server, FTP Server PROFINET 2Port Complete PROFINET-IO-Device interface (slave) Max. 1440 Byte input and max. 1440 output data Isolated PROFINET interface with 2x RJ45 connector (integrated switch) 100 Mbit/s Full-Duplex transmission 32-Bit microprocessor for fast response time Dimensions: 23 x 115 x 100 mm (B x T x H), without connector Weight approx. 160 g DIN rail IP20 Storage temperature: -40 C to +85 C Operating temperature: -40 C to +85 C,variants with RJ45 socket -25 C to + 85 C Humidity 0 % to 95 % / non condensing EtherCAT Modbus-TCP Option I/O8 CE and bus-specific certifications RoHS 100 Mbit/s Full-Duplex transmission Isolated EtherCAT interface with 2x RJ45 connector Supports CANopen communication objects, PDO and SDO Max. 1024 byte input- and 1024 byte output data Complete Modbus-TCP slave interface Max. 252 Byte input- and 252 Byte output data Isolated Ethernet interface 8 I/O can be used as In-or Output 24V / 0,7 ma (short term 1A) at max. 3A for all 8 Outputs Short circuit protection Available for the UNIGATE CL, CM, EL series Reach Delivery Each unit is supplied in a single pack Each delivery has a DVD with current documents and tools Bulkpacks and special designs on request

Deutschmann product overview PROTOCOL CONVERTER UNIGATE CL The solution for all devices with a serial interface RS232, RS485, RS422, SSI (encoder interface) on board Standard protocols can be configured (e.g. Modbus RTU, Modbus ASCII, 3964R...), more protocols can be included if needed Flexible protocol adaption via Deutschmann script language Module consists of standard components Option I/O 8 24V / 0,7 ma (short term 1A) at max. 3A for all 8 Outputs Short circuit protection Available for the UNIGATE CL, CM, EL series Protocol Converter Embedded Systems Gateways Option I/O 8 UNIGATE EL Fast Ethernet to all Fieldbuses Application-side: Fast Ethernet, RS232, RS485, RS422, SSI (encoder interface) on board Transport protocols can be configured (e.g. TCP server (port23) default, UDP, TCP server, TCP client, Modbus TCP server, Modbus TCP client) Flexible protocol adaption via Deutschmann script language Module consists of standard components ALL-IN-ONE-BUS NODE UNIGATE IC Ready-to-install Easy integration into your own electronics Module consists of standard components Connection to your host processor via UART or SPI Flexible protocol adaption via Deutschmann script language Standard protocols like Modbus, 3964R, etc. included UNIGATE FC - The connectable Multi-Protocol-Module Easy integration into your own electronics Module consists of standard components Connection to your host processor via UART or SPI Flexible protocol adaption via Deutschmann script language Standard protocols like Modbus, 3964R, etc. included UNIGATE CX - The flexible Gateway to make incompatible networks compatible Modular Gateway concept Currently approx. 120 versions available Easy configuration Wide voltage and temperature range

PriorityChannel Your notes UNIGATE CM now with What is PriorityChannel? PriorityChannel eliminates the effects of network traffic loading on the device ensuring accurate cycle-time response and safeguarding against unwanted disconnects. Industrial Ethernet has many network traffic components. In addition to the time critical cyclic messages, there are standard Ethernet messages being routed, Network Management protocols running, and Application Layer sending messages. All of these other components can interfere with the cyclic messages causing them to be delay and introducing jitter. PriorityChannel is a combination of software optimized on the unique, patented architecture of the fido1100 communication controller to separate non real-time Ethernet traffic from real-time Industrial Ethernet traffic. This is not just a special queue or sophisticated filtering. The silicon provides a separate data pathway and a separate on-chip execution environment for real-time messages to tunnel straight to the device application. Non real-time messages can never interrupt real-time messages making it possible to stay well within 160 µs of the desired EtherNet/IP cycle time, and within 10 µs of the desired Profinet cycle time. Why do you need PriorityChannel? Conventional Industrial Ethernet solutions have difficulty dealing with critical messages when network traffic increases, resulting in unpredictable packet delays, excessive latency, or even connection failure. You can t rely on the fact that factory networks will be properly segmented to keep traffic well behaved. Given the flexibility and myriad of capabilities Industrial Ethernet brings to the factory, you don t know how the network will morph over time. How do you know your device will survive? You need PriorityChannel to protect your device from the uncertainties on the factory floor. Regardless of the network condition or load, PriorityChannel to eliminate the effects of network traffic now and in the future. Critical messages are delivered on-time, every time without packet delays or excessive latency. The bottom line is, Priority Channel ensures your device will never disconnect from the network. PriorityChannel is a feature of the FIDO products from Innovasic. PriorityChannel is integrated in all Deutschmann PROFINET & EtherNet/IP products.

Global availability UNIGATE CL n Protocol Converter for all devices with a serial interface UNIGATE IC n Easy integration into your own electronics The company Deutschmann Automation, a German company based in Bad Camberg is working in the automation technology since 1976 and became known with cam controls in the 1980s. In 1989 Deutschmann Automation started operating in the fieldbus technology. The development of one s first own bus system DICNET was an essential step. Since 1996 different fieldbus and industrial Ethernet products are offered under the brand name UNIGATE. Thanks to a competent quality management and continuous enhancement Deutschmann became one of the leading suppliers in the automation industry. The entire development and manufacturing takes place in Germany. We offer workshops for our All-In-One Bus nodes of the UNIGATE IC series and the Software tool Protocol Developer. In these workshops you will learn everything you need to know about our products and how you can easily realize your projects with Deutschmann. For all products the necessary documents and tools can be found, free of cost, on www. deutschmann.com. Additionally the Deutschmann Technology Wiki, wiki.deutschmann. de, makes technological information easily accessible for our customers and users, cross-linking application know-how and ensuring that the information is up to date. Our experts in development, sales and support have the right solution for your demands. UNIGATE FC n Connectable Multi- Protocol-Module UNIGATE CX n Making incompatible networks compatible UNIGATE EL AS-i n AS-i Fast Master Ethernet M4 to all to Fieldbuses all Fieldbuses and Ethernet UNIGATE CM n CANopen to all Fieldbuses and Ethernet Deutschmann Automation GmbH & Co. KG Carl-Zeiss-Straße 8 65520 Bad Camberg Tel.: +49 6434 9433-0 Fax.: +49 6434 9433-40 info@deutschmann.de www.deutschmann.de TNR_UG_CM_E_01/17 Subject to technical changes. We do not accept liability for any misprints or errors.