EtherN.8 RDM & EtherN.2 RDM

Similar documents
Split2.8 RDM. 2 input DMX/RDM Splitter. User guide

Artistic Licence. Cata-Lynx I/P. User Guide. Cata-Lynx I/P User Guide. Version 1-4

Artistic Licence. Ether-Lynx II. User Guide. Ether-Lynx II User Guide. Version 1-5

Artistic Licence. Net-Lynx O/P. User Guide. Net-Lynx O/P User Guide. Version 1-5

Artistic Licence. Net-Lynx I/P. User Guide. Net-Lynx I/P User Guide. Version 1-5

Artistic Licence. artlynx duo. User Guide. artlynx duo User Guide. Version 1-0

Ether-Lynx User s Guide

Artistic Licence. versasplit. User Guide. versasplit User Guide. Version 1-5

SCD96 DMX Output Interface. Installation guide

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

Artistic Licence. Rail-Switch II. User Guide. Rail-Switch II User Guide. Version 5-5

Artistic Licence. Rail-Split RDM. User Guide. Serial nos and upwards. Rail-Split RDM User Guide. Version 5-0

Artistic Licence. Rail-Demux. User Guide. Rail-Demux User Guide. Version 2-7

Artistic Licence. daligate quad. User Guide. daligate quad User Guide. Version 1-0

Artistic Licence. Mica. User Guide. Mica User Guide. Version 1-1

Artistic Licence. Rail-Split extreme. User Guide. Serial numbers 151 upwards. Rail-Split extreme User Guide. Version 5-0

Artistic Licence. Rail-DALI-DMX. User Guide. Rail-DALI-DMX User Guide. Version 1-5

SAVE THESE INSTRUCTIONS

RE-82 RACK MOUNT DIMMER OWNERS MANUAL. 8 X 2400Watts. Revision /29/2007

Artistic Licence. matisse d4 dmx. User Guide. matisse d4 dmx User Guide. Version 1-1

Chroma-Q Color Web PSU 10-DMX. User Manual

CS2 DMX Distribution Splitter

E600 VX01 Installation guide

GigaSwitch 8. User Guide

CA-A480-A Elevator Controller. Reference & Installation Manual

A double yoke enables it to be operated in several positions. receiving device and then to others in a continuous "daisy chain" fashion.

Chroma-Cue. installation guide

Crossfire. User Manual. Order code: EQLED061

DMX-Merge. User s Guide. Artistic Licence Engineering Ltd Manual Revision V1.4

Contents. One Introduction 2. Two Installation 3 Front Panel 10base-T Ports 10/100base-TX Ports LEDs

User Guide. DMXSM-H18 Splitter. DMXSM-H81 Merger. Document Release Aug Revision B

ColourChaser Touch. Installation Guide

CHAPTER Wi r i n g NOTICE:

Active UTP Transceiver Hub with Integral Isolated Camera Power

UV Power Flood. User Manual. Order code: EQLED029

SP x4 DVI over Single CAT5 Distribution Amplifier. User Manual. Made in Taiwan

USB 2.0 Ranger Port USB m CAT 5e/6/7 Extender System. User Guide

Active UTP Transceiver Hub with Integral Camera Power Installation Guide

User Guide. Control Box. RoscoLED TM.

Digital Lighting Systems, Inc.

DATAGATE MK2. Box Contents. Additional Features (licenses) Features. Safety

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

icp installation guide

SD1306. Speed Dome IP Camera. Quick User Guide

Active UTP Transceiver Hub with Integral Isolated Camera Power Installation Guide

DMX512-A 2.10 HUB. User Guide

ACTpro Single Door IP Controller. Operating & Installation Instructions

LBC-H/V-T-WP LINK BRIDGE TM HDMI/VGA WALL PLATE TRANSMITTER SYSTEM

Wall Plate HDMI over Cat 5e/6 Extender - 165ft (50m)

VMI. Technical Documentation. 600 Industrial Drive, New Bern, N.C (tel / fax /

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasSound.com

8 Button IP Controller Installation and Operation Manual AV-IP-C8-WH

AB0602D ARCHITECTURAL BALLAST DRIVER. Version Date 06/25/2012

Contents. One Introduction 2. Two Installation 3 Front Panel Connecting Ports LEDs

Installation and Operation Manual. Model ER8500U / ER16500U. Patent Pending. Head-end Installation ER8500U and ER16500U. Rack Mounting Options

Transceiver Hub with Integral Camera Power

CMSA-100 Manual. Cinema Media Server Automation

PF LED Profile. User Manual

Microbar COB System. User Manual. Order code: EQLED137

Low Profile Hub. User Manual

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE

Chameleon Labs Model CPS-501 Powered Chassis

MC 11 EB-2 Power supply cabinet with external bus, AC version

Safety. Features 1 ID: Make all the connections before you plug in the main power. DMX512 Controllable and RDM Configurable

Passive UTP Transceiver Hub with Integral Isolated Camera Power Installation Guide

N4 Art-Net Node. Order code: CONT25. User Guide Please read these instructions carefully before use

Blitzer Strobe. User Manual. Order code: EQLED366

USER MANUAL Table of Contents

User Manual TL-TP70-HDC 70m HDBaseT Extender Set for HDMI, RS232 & IR All Rights Reserved Version: TL-TP70-HDC _160926

Flex Gateway Card. Installation and Operation Manual. For CPS 50kW/60kW 3-Phase String Inverters

w w w. p r o l i g h t. c o. u k Quad Par 64 (Order code: LEDJ46 - Black) (Order code: LEDJ47 - Polished) USER MANUAL

MICRON DJ Booth Tri-colour Starcloth

DVI RS-232 Extender USER MANUAL.

RGBW Mini Moving Head Stage Spot Light Model: SSL1. User Manual.

LitePad Vector User s Guide

w w w. p r o l i g h t. c o. u k TRI PAR 64 Order code: LEDJ48 - Black Order code: LEDJ49 - Polished USER MANUAL

Active UTP Transceiver Hub with Integral Camera Power Installation Guide

RGB Power Batten. User Manual. Order code: EQLED032

STANDARDS COMPLIANCE WEIGHTS AND DIMENSIONS INCLUDED FURNISHINGS

Slimline CW & WW Series

Gobo Projector XP 80W

TB-1230 QW. User Manual Please read the instruc on carefully before use

LBC-H/V-T-WP LINK BRIDGE TM HDMI/VGA WALL PLATE TRANSMITTER SYSTEM

Vector Beam White. User Manual. Order code: LEDJ265

Hyperion INTELLIGENT GIGABIT SWITCH

E-ACLM-V E-ACLM-P12/8/18 AC LINE MONITORS Installation and Operation Manual

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X

WR-5e Remote Control

FieldServer X-25 Start-Up Guide

USER MANUAL Table of Contents

MiT. MOVING image TECHNOLOGIES INSTRUCTIONS FOR INSTALLATION, OPERATION, AND MAINTENANCE

USB 400 USER MANUAL.

DMX LED Starcloth Systems

Ashly WR-5 Remote Control

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

w w w. p r o l i g h t. c o. u k STAGE PAR 64

ZF LED Zoom Fresnel. User Manual

Quick Reference Guide

Ethernet to Tok. oken Ring. Monitor RINGDALE. Quick Installation Guide. Connecting people and information

Transcription:

EtherN.8 RDM & EtherN.2 RDM Ethernet DMX output devices User guide

Please read these instructions before using the product. This product has been designed & manufactured for professional use only. It should only be installed by a suitably qualified technician and in accordance with electrical regulations in the country of use. Unless directed in the instructions, there are no user serviceable parts inside the outer case of this Product. Always disconnect from the power supply when not in use. Any specific IP rating, where appropriate, is given in the instructions. Unless otherwise stated this product is designed for Indoor use only. If used outdoors it MUST be installed in an appropriate IP rated cabinet. Do not allow this product to be exposed to rain or moisture. Do not allow liquid to penetrate the product. Please recycle all packaging. EtherN.8 RDM EtherN.2 RDM Overview EtherN.8 RDM is a 1U Rack Mounted Art-Net to DMX/RDM converter capable of outputting upto 8 universes of DMX/RDM data. EtherN.8 RDM houses four internal modules; each module comprising two DMX ports which are independently discoverable and configurable - each with four indicators. There are two Network connections to allow multiple units to be connected together. EtherN.2 RDM is a wall-mounted panel Ethernet to DMX512 converter. It converts Art-Net Ethernet data into two universes of DMX/RDM data. P2

Power Supply The EtherN.2 RDM supports both Power over Ethernet and local DC power supply (not supplied) via the supplied Jaguar DC connector. The EtherN.2 RDM can receive DC power from 9 to 48V, and consumes 2 Watts. When connected to a Power over Ethernet feed, the EtherN.2 RDM only requires the RJ45 network connection. The EtherN.8 RDM is fitted with an internal power supply which requires an 85 264V AC input with an earth connection. The mains fuse should only be replaced with a 3.15A Slow Blow. Earthing The following table details the internal Earth interconnection and isolation on the EtherN.8 RDM Circuit Chassis Description Bonded to Earth-Ground DMX512 Ports Type: Grounded Pin 1: Shell: Connects to internal Logic Ground. Ethernet Type: Transformer Isolated Internal Logic Ground Screen: Connects to Earth-Ground via 10ohm resistance The connector shell is connected to chassis Connects to Earth-Ground via 75 ohm resistance & 100pF capacitance, as specified in the IEEE standard Please note that we use the term Earth-Ground to avoid international confusion. In Europe Earth-Ground is called Earth, in the USA Earth-Ground is called Ground. Art-Net Interface Art-Net is a TCP/IP based Ethernet protocol developed by Artistic Licence. It uses standard Ethernet distribution hardware to transport many DMX universes across the network, reducing cabling. EtherN.8 RDM has two network connections, one on the front panel and one on the rear. Both can be used to connect the EtherN.8 RDM into a network. If looping to another EtherN.8 RDM it is recommended that this is only done to a maximum of three times. EtherN.2 RDM has s single network connection, on the rear, which also provides power to the unit. Connect to 10/100BaseT Ethernet Hub/Switch using Cat5 cable or better. P3

Wiring Detail The following guide should be used if custom Cat5 cables are being used. As EtherN.8 RDM has an internal Ethernet Switch, the following guidelines must be used when connecting to a network: Connecting EtherN.8 RDM to: Ethernet Switch Computer or Node Cable to be used: Cross-Over Cable Patch/Straight Cable When connecting an EtherN.2 RDM to a network, the following guidelines must be used: Connecting EtherN.2 RDM to: Computer or Node Ethernet Switch Cable to be used: Cross-Over Cable Patch/Straight Cable Patch/Straight Cable Cross-Over Cable White/Orange White/Orange White/Green White/Orange Orange Orange Green Orange White/Green Blue White/Blue Green White/Brown Brown White/Green Blue White/Blue Green White/Brown Brown White/Orange Blue White/Blue Orange White/Brown Brown White/Green Blue White/Blue Green White/Brown Brown PIN 5 PIN 1 PIN 4 PIN 3 PIN 2 RJ45 Connector XLR5 Female P4

DMX Connections The DMX512 is connected to the 5 pin XLR on the front panel. Cable connection is as follows: XLR Pin RJ45 Pin Convention Function RJ45 Colour 1 7 Black Ground White / Brown 1 8 Black Ground Brown 2 2 Blue Data - Orange 3 1 Red Data + White / Orange 4 6 n/c Aux Data - Green 5 3 n/c Aux Data + White / Green The DMX512-A standard specifies that Cat5 cable can be used to carry DMX data. The table above shows which cores should be used. It is recommended that a good quality Cat5E cable is used. For the outputs, RDM data uses the same connections as the DMX data. RDM RDM (Remote Device Management) is a PLASA Standards protocol from the Technical Standard Program that allows Bi-Directional communication over standard DMX cable. This enables a controller to have access to a DMX / RDM fixtures configuration and to alter this configuration remotely. The most obvious use is to be able to remotely set the start address of the fixture. However there are many other benefits to RDM such as sensor feedback, firmware uploads and automatic patching. EtherN.8 RDM and EtherN.2 RDM fully support the RDM protocol (E1.20-2006) via Art-Net transport, but can also be used within networks where there is no RDM present. Power Requirements EtherN.2 RDM 15VDC to 48VDC @ 200mW (RJ45, Power over Ethernet) 9VDC to 48VDC @ 200mW (Jaguar) Connection Options Powered Hub: Connect to IEEE802.3 PoE compliant 10BaseT Hub/Switch. This will provide device power via the Ethernet connector Independent Power: Connect DC power as specified above to the 2 pin Jaguar Connector located near the RJ45. EtherN.8 RDM 85VAC - 264VAC, 25W Power is supplied via IEC C13 connector. The unit must be grounded. The mains fuse should only be replaced with a 3.15A Slow Blow Fuse. P5

Indicators EtherN.2 RDM features one module, whilst EtherN.8 RDM comprises four modules. Each module has a set of indicator LEDs. The front panel Ethernet Connector on EtherN.8 RDM also has status indicators. Module Indicators STAT NET DMX A/B BOOT UP BOOT LOADER ALL FLASHING (3 times) Ethernet Indicators PWR LINK ACT SPD On when the unit is powered. Flashing if a hardware fault is found. On when the network data is active. On when DMX data is being transmitted. During boot up, the LEDs will sequentially step. When in bootloader mode, the NET LED will flash continuously. The Sub-Net switch has been changed but the value has been set remotely. Power LED. On if there is a valid link between this connection and another Ethernet device. Flashes when data is being either received or transmitted. On if this connection is running at 100BaseT, Off if running at 10BaseT. Universe & Sub-Net Selection In Art-Net each universe being transmitted is set to a particular Sub-Net and Universe number to allow it to be distinguishable from other universes on the same network. This allows up to 256 independent universes to be on the same network. Using standard Ethernet distribution the maximum number of universes is 40. With correct network design this number can be increased. Port Universe Port Universe 1 0 9 8 2 1 10 9 3 2 11 A 4 3 12 B 5 4 13 C 6 5 14 D 7 6 15 E 8 7 16 F P6

Universe By default, each port of the EtherN.8 RDM has a sequential universe number, starting from 0. To change the universe, use either the internal web-server or configure it from your ZerOS console. The table overleaf shows the default settings. Sub-Net The Sub-Net for all the modules can be set by using the front panel Sub-Net switch. Alternatively, any of the below configuration methods can be used to set a module s Sub-Net. NB: If all the indicators flash when a switch setting has been changed, the product will have been remotely configured, i.e. by DMX-Workshop or the internal web-server. Configuration There are three ways of remotely configuring a EtherN.8 RDM and an EtherN.2 RDM; Web-Server ZerOS console DMX-Workshop Web-Server To configure the EtherN.8 RDM or EtherN.2 RDM via the internal web-server, either type the IP address of one of the modules or, if your web-browser supports NetBios, then use the name; en8rdm or en2rdm in your address bar (eg: http://en8rdm/). The internal web page will show the current status of each module, such as it s DMX status and IP address. There are two options for each module; DMX Settings Sets universe & sub-net values DMX Output Profile IP Settings Set a custom IP address, Sub-Net and Gateway IP P7

ZerOS Configuration It is also possible to configure the EtherN.8 RDM and EtherN.2 RDM from within your ZerOS console (running ZerOS version 8.0 or above). In the Network/Devices tab, each module appears as a seperate device that you can configure using the on-screen controls. DMX-Workshop DMX-Workshop is free Art-Net configuration software available from Artistic Licence. Within the Network view you will see four nodes for a single EtherN.8 RDM, and one node for an EtherN.2 RDM. To configure a module, right click over the entry and the configuration menu appears. The variables that can be configured are; Universe and Sub-Net Values Label IP Address DMX Output Merge mode (LTP / HTP) Transmit Style Delta DMX Output packets are synced with incoming Art-Net packets. Continuous DMX output packets are continuously transmitted independently of the Art-Net inputs. Output Profiles When configuring the EtherN.2 RDM and EtherN.8 RDM via the web interface, three output profiles are offered to suit different DMX equipment connected. Profile Name RDM Transmit Style Max Refresh Rate Best ON Delta 43.57 FPS Compatibility OFF Delta 43.06 FPS Fix OFF Continuous 39.95 FPS In addition to these profiles, a Custom mode is offered to allow custom configuration as required. P8

Jumper Settings In normal operation EtherN.8 RDM and EtherN.2 RDM do not require any configuration. However there are several advanced settings that can be required to overcome various issues in more complex installations. To fit a jumper to EtherN.8 RDM, follow the instructions below: 1) Disconnect the Power from the unit 2) Ensure you have adequate Anti-Static protection 3) Remove the top row of screws from the front panel 4) Remove the bottom row of screws from the rear panel 5) Carefully pull the two halves apart, about 10cm The table below describes the function of each jumper. By default none of the jumpers are connected. Jumper JP0 - JP3 JP4 JP5 JP6 JP7 Option Not Assigned Connect to switch to the alternate 10.x.x.x network. Connect to disable RDM. Connect to invert the low byte of the IP address. Connect to restore default settings on EtherN.2 RDM. Not assigned on EtherN.8 RDM. ROM Boot Jumper EtherN.8 RDM and EtherN.2 RDM have a built in fail safe mode that will put the unit into a basic running state allowing new firmware to be uploaded. This is only to be used if the currently installed firmware becomes corrupted. To get an EtherN.8 RDM or EtherN.2 RDM to boot in Boot Loader mode, simply power the unit up with the ROM boot jumper linked. The Net Indicator will flash when in Boot Loader mode. If the jumper is removed and the unit is powered up it will return to the current installed firmware. Firmware Upload As new revisions of the firmware are released (due to upgrades) it is possible to upgrade your EtherN.8 RDM and EtherN.2 RDM to the latest version. Please refer to the firmware upgrade instructions (published with the firmware) for more details. P9

Error Messages On power up, the EtherN.8 RDM and EtherN.2 RDM run a number of self checks to ensure that it is functioning correctly. If an internal fault occurs the LED s are used to display an error code. LED State Stat & All Alternatively Flashing Net & All Alternatively Flashing Port A & All Alternatively Flashing Net Flashing All three times Port LED Flashing * = Contact Cooper Controls for advice Mounting Description SRAM Fault* E2Prom Fault* System ROM Fault* Module is in Boot Loader Mode Sub-Net switch is locked out Output is merging data P10

Troubleshooting Q) My fixtures are flashing randomly when connected to a EtherN.8 RDM or EtherN.2 RDM? A) The common cause of this is that they are responding to RDM data being transmitted by the EtherN.8 RDM or EtherN.2 RDM. If they are DMX512 compliant they should ignore this data. To overcome this refer to the Jumper Settings section and link the jumper to disable RDM. Alternatively this can be done via the web-server. Q) My fixture seems to lose DMX when set to high start addresses? A) Some older equipment can not handle full rate DMX refresh rates. This results in it working on lower start addresses but seems steppy on higher start addresses. To overcome this use the web-server advanced DMX page and slow the refresh rate down. Refer to the web-server section Q) EtherN.8 RDM or EtherN.2 RDM boots up but the Net LED is always flashing? A) This means that the unit has gone into boot loader mode. Uploading the latest firmware will allow the unit to function normally Q) I changed my IP address and have lost all communication with the EtherN.8 RDM or EtherN.2 RDM? A) When you change the IP address of a device out of the range the PC is on you must then change the PC IP address to match. If you still can not discover the device you will need to reset all custom settings to put it back into the default IP range (2.x.x.x). To do this refer to the Jumper Settings section Q) All the Module Indicators flash three times when I change the Sub-Net switch? A) If the Sub-Net values have been set remotely the front panel switch is ignored. The LED s flash to show that the switch is being ignored. Q) I have connected three or more EtherN.8 RDM s in series and the data seems to be delayed from the first to the last? A) If several EtherN.8 RDM s are connected in series then the data from the control source has to be re-transmitted to each one. The more in series the longer the delay. To overcome the delay use an Ethernet Switch and connect all EtherN.8 RDM s and control sources to it. Q) An output port LED is flashing continuously and the DMX LED is flashing? A) When the port LED is flashing it means that the output has two universes it is merging. P11

Warranty All products manufactured by Cooper Controls are warranted to be free from defects in material and workmanship and shall conform to and perform in accordance with Seller s written specifications. For detailed warranty information, visit our website at www.coopercontrol.com This warranty will be limited to the repair or replacement, at Seller s discretion, of any such goods found to be defective, upon their authorized return to Seller. This limited warranty does not apply if the goods have been damaged by accident, abuse, misuse, modification or misapplication, by damage during shipment or by improper service. There are no warranties, which extend beyond the hereinabove-limited warranty, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTY OF MERCHANTABILITY AND THE IMPLIED WARRANTY OF FITNESS. No employee, agent, dealer, or other person is authorized to give any warranties on behalf of the Seller or to assume for the Seller any other liability in connection with any of its goods except in writing and signed by the Seller. The Seller makes no representation that the goods comply with any present or future federal, state or local regulation or ordinance. Compliance is the Buyer s responsibility. The use of the Seller s goods should be in accordance with the provision of the National Electrical Code, UL and/or other industry or military standards that are pertinent to the particular end use. Installation or use not in accordance with these codes and standards could be hazardous. Cooper Controls Ltd International Usk House, Lakeside, Cwmbran Gwent, NP44 3HD, UK Tel: +44 (0)1633 838088 Fax: +44 (0)1633 867880 Email: enquiries@coopercontrols.co.uk North America 203 Cooper Circle Peachtree City GA, 30269, USA Tel: +1-800-553-3879 Fax: +1-800-954-7016 Email: controls@cooperindustries.com www.coopercontrol.com IM9236 - EtherN.8 RDM & EtherN.2 RDM User Guide Issue 1.0