AL168 Series Multi-Output Power Supplies

Similar documents
Rack Mount Power Supplies

DC Outdoor Power Supply/Chargers

Active UTP Transceiver Hub with Integral Isolated Camera Power

Active UTP Transceiver Hub with Integral Camera Power Installation Guide

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide

Transceiver Hub with Integral Camera Power

Active UTP Transceiver Hub with Integral Camera Power Installation Guide

Passive UTP Transceiver Hub with Integral Isolated Camera Power Installation Guide

Active UTP Transceiver Hub with Integral Isolated Camera Power Installation Guide

Passive UTP Transceiver Hub Installation Guide

Expandable Power Systems

PoE Managed Midspan Solution for Standard Network Infrastructure

8-Port Ethernet over Fiber PoE Hardened Switches Installation Manual

Outdoor Housing PIH-5063/5064/5067 INSTRUCTION MANUAL

5 B&W Rear View System Camera

3-Port Ethernet over Fiber PoE+ Hardened Switches Installation Guide

INFRARED ILLUMINATOR HOUSING 60M

1 Overview. 2 Specifications. Product Installation Document

4-Port Ethernet over Fiber PoE+ Hardened Switches Installation Guide

FC-29W 9 UN-UNIVERSAL Dome Housing. Installation Instructions

MPF-1, Mains Power Filter User Manual

Monochrome Camera. Features. User manual

Access & Power Integration Solutions

Installation Manual. 12 Volt Power Supplies. 18-Port. 9-Port RET18PT RET9PT

Installation Guide. Versatile Access Power and Integration Enclosures. Trove2M2 - Trove2 enclosure with Altronix/Mercury backplane

Configurable Output Distribution. 120V / 208V / 240V 60Hz. User Manual English

SP-1800 OWNERS MANUAL

INSTRUCTION MANUAL DISTRIBUTION UNIT. Please read this manual thoroughly before use, and keep it handy for future reference.

HDMI 1x2 Splitter B-230-HDSPLTR-1x2 INSTALLATION MANUAL HDMI OUT 2 HDMI OUT 1 B-230-HDSPLTR-1X2 POWER HDMI IN

TS-VGA OWNERS MANUAL. TS-VGA_manual_en_v1

WIRELESS BLUETOOTH BOOMBOX

TVA2.1 2-Channel Digital Amplifier Installation Manual

Installation Guide Versatile Access Power and Integration Enclosures

Network Power Distribution Module

User Manual Color Door Camera

SMART Hi-Fi AUDIO *MFL * SJ8 SIMPLE MANUAL. Wireless Multi-room Sound Bar

Industrial Camera GP-MF602. Before attempting to connect or operate this product, please read these instructions completely.

Neets Switching Relay - 2. Installation manual

BIOREP TEMPERATURE MONITOR MODEL No: BTM-01 USER MANUAL. Page 1 of 8

11.2 Universal Ceiling Mount Monitor M MENU POWER E EXIT OWNER S MANUAL

TECHCONNECT TC2-HDMI14 OWNERS MANUAL

HDMI MATRIX SWITCHER B-120-HDMATRIX-4x4/8x8 CONFIGURATION UTILITY MANUAL

OFFICE UPS MULTI-DEVICE PROTECTION UPS 500S/600S/750S

YST-SW20 SUBWOOFER SYSTEM OWNER S MANUAL. Active Servo Technology

Cluster FX-Bar. Portable performance lighting and laser rig

Z-Wave Certified Wireless Lighting Control. Auxiliary Switch ZW2001 ZW2002 rev. 09/01/11

D/N VARI-FOCAL IR CAMERA

OWNER S MANUAL SINGLE CAT5E/6 3D EXTENDER B-320-1CAT-HDIR

INSTALLATION MANUAL. HDMI 1x4 Splitter B-230-HDSPLTR-1x4. B-230-HDSPLTR-1x4 HDMI OUT 4 HDMI OUT 3 HDMI OUT 2 HDMI OUT 1 HDMI OUT 4 HDMI IN

USER S MANUAL INSTALL SERIES I4, I5, I6 & I8. Passive Full-Range speakers

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series

Wide Dynamic Range Dome Camera WDR-D3

INSTALLATION MANUAL. HDMI 1x8 Splitter B-230-HDSPLTR-1x8 B-230-HDSPLTR-1X8

+Cam Quick Start Guide

DMX Tool Splitter 1 to 5 User Manual

Daily use. indicating that the loud speakers

T-1100CM OWNER S MANUAL Universal Ceiling Mount Monitor M MENU POWER E EXIT

Measure Ø-N, Ø-Ø, Ø-Gnd with voltmeter to confirm application voltage prior to installation.

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT

HydroGuard 4 to 20 ma Output Module. For use with HydroGuard Water Quality Monitor and Controller

Roth BAR 2LX High-Power Soundbar with Wireless Subwoofer. Turn it up. Roth BAR2 LX Manual UK VJ.indd 1 19/06/ :07

SX2200 Series INSTALLATION INSTRUCTIONS. Electronic Systems Protection, Inc 8001 Knightdale Blvd. Suite 121 Knightdale NC 27545

OWNER S MANUAL GEQ 131/ 131LF GEQ 215/ 215LF GEQ 231. Single Channel 31 Band Graphic Equalizer. 2 Channel 15 Band Graphic Equalizer

KS-SB200 BOOM BOX INSTRUCTIONS LVT B [J]

OWNER S MANUAL SINGLE CAT5E/6 3D EXTENDER B-200-1CAT-HDIR. Receiver

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

CG800H SERIES USER MANUAL ZIGBEE WIRELESS SCENE CONTROL PANEL VERSION JANUARY, Disclaimers and Copyright

SOUNDSTICKS WIRELESS. Setup Guide. Downloaded from

Manual Control Unit GFC 32

Beacon Power Supply Operating and Installation Instruction Manual

U-300 Unity Amplifier User s guide

3D Blu-ray / DVD Home Theater System

Models 120LS, 200LS, 300LS, 400LS, 560LS Installation Instructions

SP-1200P POWERED SPEAKERS OWNERS MANUAL

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

INSTRUCTION MANUAL. Security Camera. Indoor/Outdoor Color Camera w/ Night Vision. Version 1.0. now you can see. Model# VU5

7 LCD CCTV Test monitor. Quick guide

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL

MODEL GE4138 DIGITAL CD/MP3/USB/SD ENCODING WITH PLL AM/FM ALARM CLOCK STEREO RADIO - USER MANUAL -

OWNER S MANUAL CD-2 V 1.3

KITCHEN ALARM CLOCK WITH PLL FM RDS RADIO - OWNER S MANUAL - MODEL NO. : CLR2610USB

Kogan Bluetooth Karaoke System with Dual Microphones KAKAR2MICA

Roth BAR 2LX High-Power Soundbar with Wireless Subwoofer. Turn it up.

SP-1400P POWERED SPEAKERS OWNERS MANUAL

Manual Simatek Control Unit GFC 32

Installation Instructions

DAB A d a pt e r 3+ Dear Customer,

USB CASSETTE PLAYER MODEL NO. : GE USER MANUAL -

Digital Photo Frame With Alarm Clock Model DPF-363

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

VIDEO DOORPHONE SYSTEM

U-150 Integrated Amplifier User s guide

Installation Notes TII Model 341 Protector

TECHCONNECT TC2-HDMI41 OWNERS MANUAL

User Manual WT-171LM / S

Manual Control Unit GFC 16

DVAA Series Disk Array for DVR1 Series Digital Video Recorder

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

SUBWOOFER SYSTEM YST-MSW10

Transcription:

AL168 Series Multi- Power Supplies Installation Guide Models Include: AL168CB - 16VAC @ 6A (100VA) or 18VAC @ 5.5A (100VA). AL168175CB - 16VAC @ 10A (175VA). AL168300CB - 16VAC @ 18A (350VA) or 18VAC @ 16A (350VA). AL168300CBM - 16VAC @ 18A (350VA) or 18VAC @ 16A (350VA). AL168600CB - 16VAC @ 40A (700VA) or 18VAC @ 36A (700VA). Rev. 070109

Overview: AL168CB Series Multi- Power Supplies provide 16VAC/18VAC distributed via eight (8) auto-resettable PTC protected outputs for powering multiple security system or access control panels. Eight (8) AL168 Reference Chart: Altronix Model Number Voltage Total Current (A) Number of PTC Protected s Current (max per output) Main Fuse Ratings on Board 115VAC 50/60Hz Input Current AL168CB 16VAC 6A 18VAC 5.5A 10A/250V 0.9A AL168175CB 16VAC 10A 15A/250V 1.45A AL168300CB 16VAC 18A 2.5A 18VAC 16A 8 AL168300CBM 16VAC 18A 18VAC 16A 15A/32V 2.7A AL168600CB 16VAC 40A Two (2) 6A 18VAC 36A 15A/32V 5.4A Specifications: Surge suppression. AC power LED indicator. Illuminated power disconnect circuit breaker with manual reset (except AL168CB). Unit maintains camera synchronization. Ease of installation saves time and eliminates costly labor. Spare fuses included. Enclosure Dimensions (H x W x D): AL168CB: 8.5 x 7.5 x 3.5 (215.9mm x 190.5mm x 88.9mm) AL168175CB and AL168300CBM: 8.5 x 7.5 x 3.75 (215.9mm x 190.5mm x 95.25mm) AL168300CB and AL168600CB: 13.5 x 13 x 3.25 (342.9mm x 330.2mm x 82.55mm) Installation Instructions: 1. Mount unit in the desired location. Mark and predrill holes in the wall to line up with the top two keyholes in the enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure s upper keyholes over the two upper screws, level and secure. Mark the position of the lower two holes. Remove the enclosure. Drill the lower holes and install the three fasteners. Place the enclosure s upper keyholes over the two upper screws. Install the two lower screws and make sure to tighten all screws (Enclosure Dimensions, pg. 7). Secure enclosure to earth ground. 2. Turn OFF main switch (except AL168CB) (Figs. 2-5, pgs. 4-6). 3. All units are factory set for 16VAC operation. For 18VAC operation adjust unit prior to mounting and applying power as follows: Change the wire position so that the black wire [18V] is connected to the terminal marked [P] and the yellow wire [16V] is connected to the terminal marked [S]. 4. Connect AC power to the black and white flying leads of the transformer(s) (Figs. 1-5, pgs. 4-6). Use 18 AWG or larger for all power connections. 5. Measure output voltage before connecting devices. This helps avoiding potential damage. Terminals marked [1P] - [8P] are positive of the same polarity. CAUTION: Determine the maximum operating voltage of the equipment being powered before adjusting the output voltage. 6. Connect devices to terminals marked [1P] - [1N] through [4P] - [4N] on PD4/PD4CB board (Figs. 3 and 5, pgs. 5-6) or terminals marked [1P] - [1N] through [8P] - [8N] on PD8/PD8CB board (Figs. 1, 2, and 4, pgs. 4-5), carefully observing polarity. 7. Turn main switch to the RESET (ON) position (except AL168CB) (Figs. 3-5, pgs. 5-6). 8. Green LED will illuminate when unit is powered. 9. Upon completion of the wiring secure enclosure door with screws (supplied). Caution: Equipment to be installed/serviced by authorized/trained personnel only. Shut branch circuit power before installing/servicing equipment. - 2 - AL168 Series

WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture. This installation should be made by qualified service personnel and should conform to the National Electrical Code and all local codes. Terminal Identification: PD4/PD4CB/PD8/PD8CB - Power Distribution Module Terminal Legend Function/Description 1P - 4P, 1P - 8P AC output. 1N - 4N, 1N - 8N AC output. LED Diagnostics: PD4/PD4CB/PD8/PD8CB - Power Distribution Module Green (AC) Power Distribution Module Status ON Normal operating condition. OFF No Power. The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the product s enclosure that may be of sufficient magnitude to constitute an electric shock. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. CAUTION: To reduce the risk of electric shock do not open enclosure. There are no user serviceable parts inside. Refer servicing to qualified service personnel. AL168 Series - 3 -

Fig. 1 - AL168CB 16VAC or 18VAC circuit breakered output 1 (Follow same procedure using terminals 2P & N through 8P & N circuit breakered outputs 2 through 8) 115VAC input 50/60 Hz, White Black XFMR Fig. 2 - AL168175CB Back Panel of Enclosure F1 F2 F3 F4 F5 F6 F7 F8 MAIN FUSE P FUSED POWER OUTPUTS D1 R1 LED N COMMON POWER OUTPUTS Power Switch 16VAC fused output 1 (Follow same procedure using terminals 2P & N through 8P & N fused outputs 2 through 8) 115VAC Input 50/60 Hz Black White XFMR - 4 - AL168 Series

Fig. 3 - AL168300CB 1P, 2P, 3P, 4P = FUSED OUTPUTS 1N, 2N, 3N, 4N = COMMON OUTPUTS 1P 1N 2P 2N 3P 3N 4P 4N LED Power Switch Voltage Selection Configuration 16VAC (Yellow) (Black) 115VAC input, 50/60 Hz. Black White XFMR* 18VAC (Black) (Yellow) Fig. 4 - AL168300CBM Power Switch MAIN FUSE Transformer underneath power supply board F1 F2 F3 F4 F5 F6 F7 F8 Black White AL168 Series - 5 -

Fig. 5 - AL168600CB Power Switch 115VAC input, 50/60 Hz. Black White XFMR* XFMR* Voltage Selection Configuration 16VAC (Yellow) (Black) 18VAC (Black) (Yellow) - 6 - AL168 Series

AL168CB 8.5 x 7.5 x 3.5 (215.9mm x 190.5mm x 88.9mm) Enclosure Dimensions (H x W x D approximate): 7.25 (184.15mm) 3.625 (184.15mm) 3.5 (88.9mm) 6.05 (153.67mm) 2 (50.8mm) 1.125 (28.575mm) 1.125 (28.575mm) 2 (50.8mm) 8.125 (206.375mm) 6.05 (153.67mm) 3.5 (88.9mm) 5.25 (133.35mm) AL168300CBM and AL168175CB 8.5 x 7.5 x 3.75 (215.9mm x 190.5mm x 95.25mm) 3.63 (92.2mm) 3.85 (97.79mm) 7.25 (184.15mm) 0.9 (22.86mm) 0.9 (22.86mm) 8.13 (206.5mm) 8.13 (206.5mm) 1.75 (44.45mm) 3.85 (97.79mm) 3.85 (97.79mm) 7.25 (184.15mm) AL168 Series - 7 -

AL168300CB and AL168600CB: 13.5 x 13 x 3.25 (342.9mm x 330.2mm x 82.55mm) 1.40 (36mm) 4.85 (123mm) 4.85 (123mm) 1.40 (36mm) 1.20 (31mm) 3.25 (83mm) 1.20 (31mm) 0.75 (19mm) 12.5 (318mm) 11.0 (279mm) 0.75 (19mm) 1.20 (31mm) 1.40 (36mm) 0.9375 (24mm) 1.40 (36mm) 5.10 (130mm) 5.10 (130mm) 13.0 (330mm) 5.10 (130mm) 6.5625 (167mm) 0.9375 (24mm) 3.25 (83mm) 3.25 (83mm) 3.25 (83mm) 1.0 (25mm) 1.0 (25mm) 1.0 (25mm) 10.5 (267mm) 1.0 (25mm) Altronix is not responsible for any typographical errors. 140 58th Street, Brooklyn, New York 11220 USA phone: 718-567-8181 fax: 718-567-9056 web site: www.altronix.com e-mail: info@altronix.com Lifetime Warranty Made in U.S.A. IIAL168Series E02Q MEMBER - 8 - AL168 Series