2D spatially selective excitation pulse design and the artifact evaluation

Similar documents
Spatially selective RF excitation using k-space analysis

Evaluations of k-space Trajectories for Fast MR Imaging for project of the course EE591, Fall 2004

MRI Physics II: Gradients, Imaging

K-Space Trajectories and Spiral Scan

Field Maps. 1 Field Map Acquisition. John Pauly. October 5, 2005

(a Scrhon5 R2iwd b. P)jc%z 5. ivcr3. 1. I. ZOms Xn,s. 1E IDrAS boms. EE225E/BIOE265 Spring 2013 Principles of MRI. Assignment 8 Solutions

Partial k-space Recconstruction

Partial k-space Reconstruction

ADVANCED RECONSTRUCTION TECHNIQUES IN MRI - 2

Sampling, Ordering, Interleaving

k y 2k y,max k x 2k x,max

Advanced Imaging Trajectories

Clinical Importance. Aortic Stenosis. Aortic Regurgitation. Ultrasound vs. MRI. Carotid Artery Stenosis

Exam 8N080 - Introduction MRI

Midterm Review

Imaging Notes, Part IV

Role of Parallel Imaging in High Field Functional MRI

EE225E/BIOE265 Spring 2011 Principles of MRI. Assignment 5. Solutions

Improved Spatial Localization in 3D MRSI with a Sequence Combining PSF-Choice, EPSI and a Resolution Enhancement Algorithm

Development of fast imaging techniques in MRI From the principle to the recent development

Fast Imaging Trajectories: Non-Cartesian Sampling (1)

Compressed Sensing for Rapid MR Imaging

Sources of Distortion in Functional MRI Data

HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008

Removal of EPI Nyquist Ghost Artifacts With Two- Dimensional Phase Correction

Slide 1. Technical Aspects of Quality Control in Magnetic Resonance Imaging. Slide 2. Annual Compliance Testing. of MRI Systems.

k y 2k y,max k x 2k x,max

Open file format for MR sequences

TOPICS 2/5/2006 8:17 PM. 2D Acquisition 3D Acquisition

3-D Gradient Shimming

Diffusion MRI Acquisition. Karla Miller FMRIB Centre, University of Oxford

surface Image reconstruction: 2D Fourier Transform

Automatic Correction of Echo-Planar Imaging (EPI) Ghosting Artifacts in Real-Time Interactive Cardiac MRI Using Sensitivity Encoding

Module 4. K-Space Symmetry. Review. K-Space Review. K-Space Symmetry. Partial or Fractional Echo. Half or Partial Fourier HASTE

Motion Artifacts and Suppression in MRI At a Glance

MR-Encephalography (MREG)

MRI Imaging Options. Frank R. Korosec, Ph.D. Departments of Radiology and Medical Physics University of Wisconsin Madison

Magnetic Resonance Imaging (MRI)

Correction for EPI Distortions Using Multi-Echo Gradient-Echo Imaging

White Pixel Artifact. Caused by a noise spike during acquisition Spike in K-space <--> sinusoid in image space

M R I Physics Course

Steen Moeller Center for Magnetic Resonance research University of Minnesota

VD-AUTO-SMASH Imaging

EE290T: Advanced Reconstruction Methods for Magnetic Resonance Imaging. Martin Uecker

Dynamic Image and Fieldmap Joint Estimation Methods for MRI Using Single-Shot Trajectories

Dynamic Autocalibrated Parallel Imaging Using Temporal GRAPPA (TGRAPPA)

Referenceless Interleaved Echo-Planar Imaging

Spiral Imaging: A Critical Appraisal

An Intuitive Explanation of Fourier Theory

High Spatial Resolution EPI Using an Odd Number of Interleaves

Classification of Subject Motion for Improved Reconstruction of Dynamic Magnetic Resonance Imaging

Computational Aspects of MRI

XI Signal-to-Noise (SNR)

Digital Image Processing. Lecture # 3 Image Enhancement

Sampling, Ordering, Interleaving

Following on from the two previous chapters, which considered the model of the

CHAPTER 9: Magnetic Susceptibility Effects in High Field MRI

Applications Guide for Interleaved

IMAGE reconstruction in conventional magnetic resonance

Fast Imaging UCLA. Class Business. Class Business. Daniel B. Ennis, Ph.D. Magnetic Resonance Research Labs. Tuesday (3/7) from 6-9pm HW #1 HW #2

FOCUS. Image Based Automatic Shimming Using B 0 Gradients. Installation and Users Guide Version 0.9

Module 5: Dynamic Imaging and Phase Sharing. (true-fisp, TRICKS, CAPR, DISTAL, DISCO, HYPR) Review. Improving Temporal Resolution.

Sparse sampling in MRI: From basic theory to clinical application. R. Marc Lebel, PhD Department of Electrical Engineering Department of Radiology

Use of Multicoil Arrays for Separation of Signal from Multiple Slices Simultaneously Excited

The SIMRI project A versatile and interactive MRI simulator *

Edge and local feature detection - 2. Importance of edge detection in computer vision

HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2006

Dynamic Contrast enhanced MRA

FOV. ] are the gradient waveforms. The reconstruction of this signal proceeds by an inverse Fourier Transform as:. [2] ( ) ( )

Introduction to Digital Image Processing

Non-Cartesian Parallel Magnetic Resonance Imaging

Computational Medical Imaging Analysis

ARTICLE IN PRESS YNIMG-03684; No. of pages: 14; 4C:

Automatic Gradient Preemphasis Adjustment: A 15-Minute Journey to Improved Diffusion-Weighted Echo-Planar Imaging

CoE4TN4 Image Processing. Chapter 5 Image Restoration and Reconstruction

HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008

Zigzag Sampling for Improved Parallel Imaging

3. Image formation, Fourier analysis and CTF theory. Paula da Fonseca

Motion artifact reduction technique for dual-contrast FSE imaging

Unaliasing by Fourier-Encoding the Overlaps Using the Temporal Dimension (UNFOLD), Applied to Cardiac Imaging and fmri

CANAL FOLLOWING USING AR DRONE IN SIMULATION

Supplementary methods

Lecture 4. Digital Image Enhancement. 1. Principle of image enhancement 2. Spatial domain transformation. Histogram processing

MRI image formation 8/3/2016. Disclosure. Outlines. Chen Lin, PhD DABR 3. Indiana University School of Medicine and Indiana University Health

Accelerated MRI Techniques: Basics of Parallel Imaging and Compressed Sensing

COBRE Scan Information

General and Efficient Super-Resolution Method for Multi-slice MRI

Spread Spectrum Using Chirp Modulated RF Pulses for Incoherent Sampling Compressive Sensing MRI

Experimental Competition. Sample Solution

SIMULATION D'IRM ANGIOGRAPHIQUE PAR EXTENSION DU LOGICIEL JEMRIS

Magnetic Resonance Angiography

Single-Shot Spiral Imaging Enabled by an Expanded Encoding Model: Demonstration in Diffusion MRI

SUPPLEMENTARY FILE S1: 3D AIRWAY TUBE RECONSTRUCTION AND CELL-BASED MECHANICAL MODEL. RELATED TO FIGURE 1, FIGURE 7, AND STAR METHODS.

11.2 RECTANGULAR COORDINATES IN THREE DIMENSIONS

Single-sided Magnet Diffusion Measurements

Fast Isotropic Volumetric Coronary MR Angiography Using Free-Breathing 3D Radial Balanced FFE Acquisition

Lab Location: MRI, B2, Cardinal Carter Wing, St. Michael s Hospital, 30 Bond Street

MRI Reconstruction using Real-Time Motion Tracking: A Simulation Study

Motion Robust Magnetic Susceptibility and Field Inhomogeneity Estimation Using Regularized Image Restoration Techniques for fmri

2D Fan Beam Reconstruction 3D Cone Beam Reconstruction

Transcription:

EE 591 Project 2D spatially selective excitation pulse design and the artifact evaluation 12/08/2004 Zungho Zun

Two-dimensional spatially selective excitation is used to excite a volume such as pencil beam or cylinder-like shape (1). It can also be used to obtain reduced FOV in slice selective excitation, which corresponds to a rectangular stick in the object domain (2). This study is to explore how to design RF and gradient pulses in order to excite a desired volume given gradient limitations, and to see how off-resonance and gradient delay affect the excitation profile. In the present work, echo-planar RF pulse with forward-backward design scheme is adopted (3). MATERIALS AND METHODS PULSE DESIGN As Pauly et al. developed (4), the relationship between the spatial weighting deposited by RF pulse and the 2D excitation volume is Fourier transform formula. M xy (x,y) = i γ M o integral kx ky P(k x, k y ) e ixkx e iyky dk x dk y [1] where P(k x, k y ) = W(k x, k y ) S(k x, k y ). S(k x, k y ) is a sampling structure that is determined by the k-space trajectory, and W(k x, k y ) is a spatial weighting function defined by W(k x, k y ) = B1(t)/ γg(t). Also, k x (t) = -γ t T G x (s)ds [2] k y (t) = -γ t T G y (s)ds [3] More exactly, P(k x, k y )=1/(2πγ) FT{ M xy (x,y) } [4] The desired excitation shape in the object domain is set to rect(ax)cos 2 (by) as shown in Fig.1 so that the spatial weighting function in the excitation k-space is 1/a sinc(1/a k/(2π)) π 2 (δ (k y +2b) + 2δ( k y ) + δ( k y -2b), i.e.,!(ax)cos 2 (by) 1/a sinc(1/a k/(2π)) π 2 (δ (k y +2b) + 2δ( k y ) + δ( k y -2b) [5] which leads to 1-2-1 binomial weighting (5) with sub-pulses, as shown in Fig.1. The subpulses used here are only the main-lobe of sinc pulse which covers the k-space from 2π

to 2π in k x -axis, and 2b from to 2b in k y -axis as visualized in Fig.2. The truncation in the coverage of k x -axis will cause blurring in x-axis in the object domain. Fig.3 shows the forward-backward design trajectory also known as non-flyback. Since Fourier relationship holds true mostly for a small tip-angle, the RF pulse amplitude should not be chosen too large. In this experiment, the parameter a and b are both set to 0.05, and RF pulse duration is 5.5ms. The designed RF and gradient pulses are shown in Fig.4, and the resultant excitation in Fig.5. In real MR scanner, the slew rate and maximum value in gradient pulse should be considered. Therefore, the gradient pulse should be trapezoid shape as opposed to rectangular due to the slew rate limitation, and the slope of transition should be designed making the most of the maximum slew rate in order to reduce the time duration. Also, the use of maximum limit value in the gradient strength will save the time duration, enabling the k-space scanning velocity fast. Pulse duration time is a critical issue because offresonance and flow artifact show more impact in longer time duration. And longer TE degrades imaging quality as well. Fig.1. Desired excitation shape in the object domain.

Fig.2. RF pulse deposited in the excitation k-space. Weighting function is truncated along k x axis. Fig.3. Echo-planar forward-backward trajectory in the k-space.

B1(t) 0.06 0.04 0.02 0 0 200 400 600 800 1000 1200 1400 Gx(t) 0.04 0.02 0-0.02-0.04 0 200 400 600 800 1000 1200 1400 Gy(t) 5 x 10-3 0-5 -10 0 200 400 600 800 1000 1200 1400 Fig.4. Designed pulse sequences. Sampling period is set to 4µs and total pulse duration is 5.5ms. Slew rate and maximum limitation of gradient is not considered in the simulation. y x

Fig.5. Numerically calculated excitation profile in the object domain. Since cos 2 (y) is a period of π, two peaks can be seen within a FOV. OFF-RESONANCE AND GRADIENT DELAY ARTIFACT While the forward-backward scheme in echo-planar pulse helps to save the time duration, it also causes serious artifact in the presence of off-resonance and gradient delay compared to flyback design. A generic non-flyback echo-planar trajectory can be viewed as a sum of two flyback trajectory scans as shown in Fig.6 in which case, the off-resonance is a negative value. With halved amplitudes, the final object is shifted along x-axis as well as y-axis because there is a linear phase not only in x-direction but also in y-direction. The even line scan and odd line scan cause the opposite shift along x-axis due to the reversed scan direction while the shift along y-direction is the same. And also, odd line scan in the k- space causes alternating sign of replicas in object domain because of the shifted sampling. The final result is a sum of two excitation shapes. Matlab simulation shows the expected results in Fig.7. Off-resonance of 50Hz, -100Hz, and 440Hz are used here. For 50Hz and 100Hz, artifact in x-axis is not noticeable because the scan time along x-axis is short compared to y-axis scanning. Artifact in x-axis is more visible with off-resonance of 440Hz. The object is separated in x-direction and also, incomplete destructive interference shows up halfway between Nyquist replicas. Phase inconsistency caused by eddy current, gradient imperfection or anisotropic gradient delay in echo-planar excitation also generates so-called N/2 ghosts as in echo-planar imaging. In a similar way to the above analysis, echo-planar trajectory can be thought of as a sum of even and odd line trajectories. Since gradient delay causes alternating shift in even and odd lines in the k-space, the corresponding object domain excitation has the opposite phase shift to each other as shown in Fig.8. As time delay gets greater, N/2 ghosts get bigger. Matlab simulation shows the consistent result as visualized in Fig.9.

Fig.6. Off-resonance artifact analysis in non-flyback echo-planar design. White circle denotes the opposite sign of the back circle.

y x (a) For f = -50Hz y x (b) For f = -100Hz

y x (c) For f = -440Hz Fig.7. Excitation shape change in the presence of off-resonance of 50Hz, -100Hz, and 440Hz.

Fig.8. Gradient delay artifact analysis in non-flyback echo-planar design. For a small time delay a, cos(a) is almost 1 and sin(a) is close to 0. As the delay gets greater, N/2 ghosting grows up.

y x (a) When the gradient is delayed by 8% of the subpulse duration. y x (b) When the gradient is delayed by 12% of the subpulse duration.

y x (c) When the gradient is delayed by 16% of the subpulse duration. Fig.9. The artifact caused by gradient delay. With longer time delay, N/2 ghosting grows up. DISCUSSION The major drawback of 2D selective excitation is the longer RF pulse duration, which causes many artifacts in the presence of flow, motion, or off-resonance. To reduce the time duration, slew rate and maximum gradient limit should be utilized at the most, and echoplanar trajectory can be adopted. Especially, forward-backward scheme saves pulse duration twice as the flyback design because it deposits RF energy in the k-space during both positive and negative gradient lobes. At the same time, however, it is very susceptible to system imperfections such as off-resonance and gradient delay. In this study, how these artifacts affect the 2D excitation pulse in non-flyback echo-planar design has been examined. They show almost the same effect as in echo-planar imaging. Off-resonance imposes linear phase in the excitation k-space, which corresponds to shift in the object domain. Conversely, gradient delay generates shift in the k-space domain resulting in linear phase in the object domain. Due to the alternating shift (or linear phase) in the non-flyback k-space lines, the desired interference destruction in N/2 position of FOV becomes

incomplete, and therefore produces unwanted excitation. These artifacts can be resolved by the similar solutions from echo-planar imaging, and could be improved in further study. ACKNOWLEDGMENT 1-2-1 binomial weighting has been adopted in this work at Kyunghyun Sung s suggestion. REFERENCES 1. Schroder C, Bornert P, Aldefeld B. Spatial excitation using variable-density spiral trajectories. J Magn Reson 2003;18:136-141 2. Rieseberg S, Frahm J, Finsterbusch J. Two-dimensional spatially-selective RF excitation pulses in echo-planar imaging. Magn Reson Med 2002;47:1186-1193 3. Oelhafen M, Pruessmann KP, Kozerke S, Boesiger P. Calibration of echo-planar 2Dselective RF excitation pulses. Magn Reson Med 2004;52:1136-1145 4. Pauly J, Nishimura D, Macovski A. A k-space analysis of small-tip angle excitation. J Magn Reson 1989;81:43-56 5. Hore PJ. Solvent suppression in Fourier transform nuclear magnetic resonance. J Magn Reson 1983;55:283-300 APPENDIX : MATLAB CODE close all; clear all; a=0.05; b=0.05; D=0; df=0;

Morig=[0;0;1]; gamma=26752; m=10^(-3); T=5.5*m; dt= 4*10^(-6); N=T/dt; %%%%% gx(t) generation for k=1:n t=dt*k; if (0<t& t<=m) (4*m<t& t<=5*m) gx(k)=4*pi*a/m/gamma; elseif (2*m<t& t<= 3*m) (5*m<t& t<=5.5*m) gx(k)=-4*pi*a/m/gamma; else gx(k)=0; %%%%% gy(t) generation for k=1:n t=dt*k; if (m<t& t<=2*m) (3*m<t & t<=4*m) gy(k)=2*b/m/gamma; elseif 5*m<t & t<=5.5*m gy(k)=-4*b/m/gamma; else gy(k)=0;

%%%%% b1(t) generation for k=1:n t=dt*k; if 0<t & t<=m b1(k)= sinc((t-0.5*m)/(m/2)) * sqrt( gx(k)^2+gy(k)^2 ); elseif 2*m<t & t<=3*m b1(k)= 2*sinc((t-2.5*m)/(m/2))* sqrt( gx(k)^2+gy(k)^2 ); elseif 4*m<t & t<=5*m b1(k)= sinc((t-4.5*m)/(m/2))* sqrt( gx(k)^2+gy(k)^2 ); else b1(k)= 0; %%%% gradient delay generation if D~=0 for k=1:d gxd(k)=0; gyd(k)=0; for k=d+1:n gxd(k)=gx(k-d); gyd(k)=gy(k-d);

for k=1:n gx(k)=gxd(k); gy(k)=gyd(k); %%%% excitation process x=-2/a: 4/a/20 :2/a; y=-pi/b: 2*pi/b/20 :pi/b; for i=1:length(x) for j=1:length(y) M=simpulse2(b1,gx,gy,dt,Morig,x(i),y(j),df); Mxy(j,i)=sqrt( M(1)^2 + M(2)^2 ); %%%% pulses and Mxy plotting figure(1); subplot(3,1,1); plot(b1); subplot(3,1,2); plot(gx); subplot(3,1,3); plot(gy); figure(2); dispimage(mxy); xlabel('x'); ylabel('y');