Serial to Ethernet Converter

Similar documents
Infosystem. User Manual. Version 1.0. Serial to Ethernet Converter with 3 sockets. Infosystem Technology Corporation, Ltd.

WM-120. Serial to Ethernet Module. Serial to Ethernet Module. User Manual. Version 1.0. Infosystem Technology Corporation, Ltd.

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL

NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL

User s Guide. Ethernet Module for Barcode Printer

ACE PLUS CORP. APCON100 series Operation Manual RS-232 to Ethernet Converter

SERIAL TO ETHERNET CONVERTER E-P User Manual

Document Name: User Manual for SC10EK4 Serial to Ethernet Converter with 4 TCP Sockets. Index

TRP-C37. Ethernet to RS232/422/485 Converter. User s Manual. Printed Apr.2014 Rev 1.3

Lantech LSC-1102B SERIAL TO TCPIP CONVERTER. User Manual

TRP-C37 User s Manual

Serial to Ethernet Converter HL-SE02P-V1. User s Manual V3.606

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

RS-232/422/485 Over IP Adapter

ON 1 2 NT-V A 321S DIMENSIONS FRONT VIEW 4xΦ (UNIT: mm) INPUT RANGE & MODE SELECTION SW1 SW2 +Ch5 -Ch5 +Ch6 -Ch6 +Ch7 -Ch

Operation Manual of EX-9132C-2. Serial to TCP/IP Converter

WIZ220IO / WIZ220IO-EVB User s Manual (Ver. 1.0)

Operation Manual EX-9133C-2-MTCP

TRP-C37. Ethernet to RS232/422/485 Converter. User s Manual. Printed September Rev 1.6

TCP/IP Converter. EX-9132 Operation Manual for 8051 Series

Operation Manual of EX9132CST-Series

MSD-SRF2XM Multi-port RS-232 to Ethernet Data Gateway User Manual

2-Port RS-232/422/485 Serial over IP Ethernet Device Server Installation Guide

e-net TCP/IP Converters

TRP-C37M User s Manual

1 port RS-232 Device Server

USER S MANUAL. PH485Ex1. #1 RS-485 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH485Ex1-UM-001 IPEX. (IP Electronix)

Industrial Serial Device Server

ZLAN5443A. User Manual

INDEX. Document Name : User Manual for SC10EJ Serial to Ethernet Converter

Serial Device Server- Dual Port Quick Installation Guide

Universal ipulse Ethernet Adapter. User Manual

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter

User Manual A08. User Manual

ECOV-110 User s Manual

Tel: Fax:

MGate TM EIP3000 DF1 to EtherNet/IP Gateway User s Manual

NordField Electronics

RS-232/422/485 to Copper or Fiber. Ethernet Converter. User s Manual

Serial to TCP/IP Converter

tsh-700 Series User Manual

ECAN-240. (Modbus TCP to 2-port CAN Bus Gateway User manual) ECAN-240 Modbus TCP to 2-port CAN Bus Gateway User Manual, Version 1.0.

Embedded Modbus TCP Module GS11-MT. User Manual REV 1.1. SST Automation.

MGate MB3000 Modbus Gateway User Manual

TRP-C37M User s Manual

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X

Ethernet Serial Server

User Manual Edition: v a

SSE232-LE Serial Server- User s Manual

EX-6014WI RS232 to WiFi Wireless Adapter, w/ Mounting Kit

RS232/RS485/RS422 to TCP/IP Converter ITEM NO.: RS007

BF-430 User Manual Document Version 1.0 Web Version realcom Firmware Version ,Apr

USB to RS-232/RS422/485. US-101-I USB To Serial Operation Manual

HOME AUTOMATION, INC. Model 93A00-1. Serial Server. User s Manual

CHIYU. Product Specification BF-450(M)/BF-430. RS232/RS485/RS422 To TCP/IP Converter Module. Release 1.0

Model XS1000 TCP/IP to RS232/422/485 Device Server User s Manual

Communication adapter RS485/422 over the Ethernet ELO E222. User manual

TRP-C08. USB to RS232/422/485 Isolated Converter. User s Manual. Printed Sep.2014 Rev 1.4

Internet Camera Quick Installation Guide

MGate MB3000 Modbus Gateway User s Manual

ecov-110 User s Manual (V0.9f_Eng)

SERIAL TO TCPIP CONVERTER E-P232-X. User Manual

EQ-DCM User Manual Revision 1.02 Sep 10, 2013

Ethernet to Serial Port Module RS-232/422/485 to Internet Gateway

rbox610 Series Robust Din-rail Fanless Embedded System Web Configuration and App Software User s Manual

GW-7238D J1939 to Modbus TCP Server / RTU Slave Gateway

Winsonic MODBUS Remote IO user manual Rev. 1.0

NET101. RS232 / RS422 / RS485 to Ethernet Converter. User s Manual. Version 1.2

tgw-700 Series User Manual

ZLSN2002 Embedded Device Networking Module. User Manual

Support 1 RS-232 or RS-485/422 serial port to 1 10/100Base-T(X) self-adaptive Ethernet interface

Quick Start Hardware Testing Environment Connection Default Parameter Data Transmission Testing

ABLELink. Modbus Gateway MB5000 Series User s Manual

WIZ125SR User Manual

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision

USR-TCP Hard version: V2.0 File version: V

T1K MODBUS Base Controller Specifications

TRP-C34H. Ethernet to 4 RS232/422/485 Converter. User s Manual. Printed Sep Rev 1.1

User Manual. cmt-svr Startup Guide

User Manual. cmt-svr Startup Guide

Features and Benefits. Certifications

User s Manual Printed Sep Rev 1.2

Overview. Table of contents

Ethernet to RS-232/485 Gateway

LM300 Bluetooth Ethernet Access Point/Server 3 Simultaneous Bluetooth SPP Connections

Chapter 1 Introduction

Lantech IRC-0101 RS-232/422/485 TO TCP/IP CONVERTER. User Manual

TRP-C08M. USB To 4 RS232/422/485 Isolated Converter. User s Manual. Printed Jun Rev 1.0

ZigBee Converter User s Manual

1 Access to the configuration page

NetBiter Serial Server User Manual

IDS-141A/181A. Industrial 4-port/8-port slim type serial to Ethernet device server. Features. Introduction. DS-Tool

Application. Contents of Package. Inspect the CyberSwitch upon receipt. The package should contain the following items:

EZL-400S User s Manual

LM300 Bluetooth Ethernet Access Point/ Server 3 simultaneous Bluetooth SPP connections

ETHM-2. Ethernet Module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

LM300 Manager User Manual. Document Version: 1.1 LM300 Firmware Version: Bluetooth Firmware Version:

MD-N32 Serial to Ethernet Gateway Installation and Operating Guide

DGH A3000 Configuration Guide For use with DGH Modules

GEM80 & ewon Setup Quick Guide

Transcription:

Serial to Ethernet Converter User s Manual Version 1.1 2004 Infosystem Technology Corporation

Disclaimers The information in this manual has been carefully checked and is believed to be accurate. Infosystem Automation Corporation assumes no responsibility for any infringements of patents or other rights of third parties which may result from its use. Infosystem assumes no responsibility for any inaccuracies that may be contained in this document. Infosystem makes no commitment to update or to keep current the information contained in this manual. Infosystem reserves the right to make improvements to this document and/or product at any time without notice. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form of or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of Infosystem Automation Corporation. Copyright 2004, by Infosystem Technology Corporation. Version 1.1 All rights reserved. Printed in Taiwan Warranty All products manufactured by Infosystem are warranted against defective materials for a period of one year from the date of delivery to the original purchaser. Trademark The names used for identification only maybe registered trademark of their respective companies. i

Table of Contents 1. INTRODUCTION...1 1.1 FEATURES AND SPECIFICATIONS... 2 1.2 LED INDICATOR AND SWITCH DESCRIPTION... 4 2. RS232/422 SPECIFICATIONS AND WIRING...5 3. I/O SPECIFICATIONS AND WIRING*...7 3.1 2 POINTS, 24V DC INPUT... 8 3.2 2 POINTS, DC 0.5A DIGITAL OUTPUT... 9 4.MODBUS ADDRESS MAPPING*...10 4.1 MODBUS HOLDING REGISTER 40001... 10 4.2 MODBUS HOLDING REGISTER 40002... 10 5. SOFTWARE INSTALLATION...11 6. CONFIGURING THE ETHERNET CONVERTER...14 6.1 CONFIGURING WITH ETHERNET CONVERTER SETUP PROGRAM... 14 6.2 CONFIGURING WITH WEB BROWSER... 21 APPENDIX 1: COMMAND MODE SUPPORT...25 ii

1. Introduction Infosystem WS-100 and WS-1000 Serial to Ethernet converters are ideal products for any RS-232/422/485 device to connect to an existing Ethernet network. With WS-100 and WS-1000 and related products, the controlling and monitoring of serial devices can be easily accomplished. 1

RS232/485/422 1.1 Features and Specifications RJ-45 Ethernet Port Size: 100*68*25(mm LED Indicator RS232/485/422 DC 24V Power Input Features: Allows RS-232/422/485 serial devices to be connected to Ethernet network via transparent data conversion and operates as an Ethernet node. Serial communication speed is up to 115.2 kbps. Supports ARP, ICMP, TCP, UDP, IP, DHCP, HTTP, Modbus/TCP, and 10Base-T Ethernet standard. Supports Web Based interface for fast configuration without special software, also in Command mode for parameters setting by application software. Supports Client/Server applications. Supports Winsock networking programming and optional Virtual serial ports driver for windows application program. 2

Specifications: Model Items Network Interface Protocol Reset Watch Dog Timer Discrete I/O Serial Port Serial Communication Led Indication Power Requirement Temperature Humidity Dimension Configuration WS-1100 WS-1200 WS-1300 WS-1400 10/100BaseT, RJ-45 ARP, ICMP, TCP, UDP, IP, DHCP Client, HTTP Built-in reset key to restore the defaults Built-in hardware auto reset function 2 points, DC 24V 2 points, DC 24V 2 points, DC 24V Input/ 2 points, DC Input/ 2 points, DC Input/ 2 points, DC none 0.5A Output 0.5A Output 0.5A Output RS-232/RS-422/R RS-232/RS-422/R RS-232/RS-422/R RS-232/RS-422/R S-485x2, S-485x2, S-485x1, S-485x2, Configurable Configurable, Configurable, Configurable RS-232x1 RS-232x2 Data speed: Data speed: Data speed: Data speed: 300-115200 bps 300-115200 bps 300-115200 bps 300-115200 bps Data bits: 7, 8 Data bits: 7, 8 Data bits: 7, 8 Data bits: 7, 8 Parity: None, Parity: None, Parity: None, Parity: None, Even, Odd Even, Odd Even, Odd Even, Odd Stop bits: 1, 2 Stop bits: 1, 2 Stop bits: 1, 2 Stop bits: 1, 2 Flow control: Flow control: Flow control: Flow control: RTS/CTS, RTS/CTS, RTS/CTS, RTS/CTS, SYS x1(red), LINKx1(Green) RXx1(Green), TXx1(Red) 24VDC, power consumption<1w Operation: 0ºC~+55º C (32ºF~+131ºF) Storage: -20ºC~+70ºC (-4ºF~+158ºF) 15% to 95% (non-condensing) 100mmx68mmx25mm Web Browser, Windows utility via Ethernet 3

1.2 LED Indicator and Switch Description SYS LINK TX RX OFF LED Indicator: LED SYS LINK TX RX Description The SYS LED blinks at a rate around 1 Hz, when CPU is working normally with the module. If ON, the Ethernet connection is activated. If ON, the converter is transmitting data to the Ethernet. If ON, the converter is receiving data from Ethernet. Switch Description: Switch SW1 SW2 OFF: Update Firmware ON: Normal Mode Reserved Description 4

2. RS232/422 Specifications and Wiring a. With UART + 2 Digital Output + 2 Digital Input Converter There are two terminal blocks at each side of the Gateway, one is 9 Pin terminal block and another is 13 Pin terminal block. The 1 st pin of the 9 Pin terminal block is neighbor the RJ-45 Ethernet connector and the 1 st of the 13 Pin terminal block is neighbor the 2PIN DIP Switch. Please see below is the Pin layout of the Gateway.. Connector and Pin Descriptions: RJ-45 It is an 8 Pin RJ-45 Ethernet connector; it is connected to the Ethernet Hub or another Host via Ethernet CAT-5 cable. The data rate can be 10/100MHz. 9 Pin Terminal Block This connector offer two UART port connection, the pin description is in the following table. 9 Pin TB 1 RXD-1 RS-232 Data Input In COM1 2 TXD-1 RS-232 Data Output Out 3 RTS-1 RS-232 Request to Send Out 4 CTS-1 RS-232 Clear to Send In 5 GND RS-232 Ground Power 6 RXD-2/DX+ RS-232 Data Input /RS-422/RS-485/DX+ In/- COM2 7 TXD-2/DX- RS-232 Data Output /RS-422/RS-485/DX- Out/- 8 RTS-2/TX+ RS-232 Request to Send /RS-422/TX+ Out/- 9 CTS-2/Tx- RS-232 Clear to Send, /RS-422/Tx- In/- 13 Pin Terminal Block 13 Pin TB 1 RXD-23DX+ RS-232 Data Input /RS-422/RS-485/DX+ In/- COM3 2 TXD-23DX- RS-232 Data Output /RS-422/RS-485/DX- Out/- 3 RTS-23TX+ RS-232 Request to Send /RS-422/TX+ Out/- 4 CTS-3/Tx- RS-232 Clear to Send, /RS-422/Tx- In/- 5 GND RS-232 Ground Power I/O 6 DO-1 Digital Output, Driven 100mA/24V Load Out 7 DO-2 Digital Output, Driven 100mA/24V Load Out 5

8 DI-1 Digital Input, 24V Signal Input In 9 DI-2 Digital Input, 24V Signal Input In 10 EGND Digital I/O Power Ground Power 11 E24V Digital I/O 24V Power Power POWER 12 +24GND Gateway Power Ground In Power 13 +24 Gateway Power +24V In Power 2 Pin DIP Switch DIP Switch SW 1 ON OFF Normal Operation, This PIN define the Normal Operation Mode or Enter the Firmware update mode, when ON enter the Normal Operation Mode, when OFF enter the Firmware update mode. Firmware Update, Please see above description, SW 2 ON OFF. Reserved, Keep this pin on ON Position b. 4 UART Converter There are two terminal blocks at each side of the Gateway, one is 9 Pin terminal block and another is 13 Pin terminal block. The 1 st pin of the 9 Pin terminal block is neighbor the RJ-45 Ethernet connector and the 1 st of the 13 Pin terminal block is neighbor the 2PIN DIP Switch. Please see below is the Pin layout of the Gateway. Connector and Pin Descriptions: RJ-45 It is an 8 Pin RJ-45 Ethernet connector; it is connected to the Ethernet Hub or another Host via Ethernet CAT-5 cable. The data rate can be 10/100MHz. 9 Pin Terminal Block This connector offer two UART port connection, the pin description is in the following table. 9 Pin TB 1 RXD-1 RS-232 Data Input In COM1 2 TXD-1 RS-232 Data Output Out 3 RTS-1 RS-232 Request to Send Out 4 CTS-1 RS-232 Clear to Send In 5 GND RS-232 Ground Power 6

6 RXD-2/DX+ RS-232 Data Input /RS-422/RS-485/DX+ In/- COM2 7 TXD-2/DX- RS-232 Data Output /RS-422/RS-485/DX- Out/- 8 RTS-2/TX+ RS-232 Request to Send /RS-422/TX+ Out/- 9 CTS-2/Tx- RS-232 Clear to Send, /RS-422/Tx- In/- 13 Pin Terminal Block 13 Pin TB 1 RXD-23DX+ RS-232 Data Input /RS-422/RS-485/DX+ In/- COM3 2 TXD-23DX- RS-232 Data Output /RS-422/RS-485/DX- Out/- 3 RTS-23TX+ RS-232 Request to Send /RS-422/TX+ Out/- 4 CTS-3/Tx- RS-232 Clear to Send, /RS-422/Tx- In/- 5 GND RS-232 Ground Power 6 RXD-4 RS-232 Data Input In Com4 7 TXD-4 RS-232 Data Output Out 8 RTS-4 RS-232 Request to Send Out 9 CTS-4 RS-232 Clear to Send In 10 NC NOT USED NC 11 NC NOT USED NC POWER 12 +24GND Gateway Power Ground In Power 13 +24 Gateway Power +24V In Power 2 Pin DIP Switch DIP Switch SW 1 SW 2 ON OFF ON OFF Normal Operation, This PIN define the Normal Operation Mode or Enter the Firmware update mode, when ON enter the Normal Operation Mode, when OFF enter the Firmware update mode. Firmware Update, Please see above description, Reserved, Keep this pin on ON Position 3. I/O Specifications and Wiring* *(Only the Model WS-1122, WS-1222, WS-1322 offer the I/O Pin) 7

The specifications and wiring diagrams of DI and DO modules are listed here. 4 Port Converter do not support the I/O feature. 3.1 2 points, 24V DC input a. Specification: Model Specification Number of input points Insulation method Rated input voltage Rated input current Operating voltage range Turn ON state Turn OFF state Input impedance Response time OFF ON ON OFF Common terminal arrangement Internal current consumption DIGITAL INPUT 2 points Photo Coupler 24V DC 7 ma 21.6V DC~26.4V DC 12VDC/2mA or higher 4VDC/1mA or lower Approx. 3.9 KΩ 8 msec or less (24VDC) 8 msec or less (24VDC) 12 points/common Max.100 ma (type, all points ON) b. Equivalent input circuit: 8

3.2 2 points, DC 0.5A Digital Output a. Specification: Model Specification Number of input points Insulation method Rated load voltage Operating voltage range Type Max. load current Leakage current at OFF circuit Max. voltage drop at ON circuit Response time OFF ON ON OFF Common terminal arrangement External power supply Voltage Current International current consumption DIGITAL OUTPUT 2 points Photo coupler 24VDC 21.6VDC~26.4VDC NPN/Sink 0.5A/pt 0.1 ma or less 1.5V or less 8 msec or less 8 msec or less 6 points/common 24VDC (21.6VDC~26.4VDC) 100mA 100 ma (type, all points on) b. Equivalent input circuit: 9

4.Modbus Address Mapping* *(Only the Model WS-1122, WS-1222, WS-1322 offer Modbus Read/Write) The discrete I/O points of the Ethernet Converter can be easily control and monitor through Modbus/TCP protocol. The Modbus address mapping with discrete I/O is described below. 4.1 Modbus Holding Register 40001 The 2-point digital output of the Ethernet Converter is mapped with the Modbus holding register 40001. The following table describes the exact bit-mapping for Modbus holding register 40001. Modbus Holding Register 40001 Digital Output DO-1 Bit 0 (40001:0) DO-2 Bit 1 (40001:1) 4.2 Modbus Holding Register 40002 The 12-point digital input of the Ethernet Converter is mapped with the Modbus holding register 40002. The following table describes the exact bit-mapping for Modbus holding register 40002. Modbus Holding Register 40002 Digital Input DI-1 Bit 0 (40002:0) DI-2 Bit 1 (40002:1) 10

5. Software Installation 5.1 Insert the software CD that came with Ethernet Converter into the CD-ROM drive, refer to the path D: \Tool\Install\ (D:\ stands for the CD-ROM drive) and double click on setup.exe to install the Ethernet I/O Utility Program. The following screen is displayed. Click the OK button to proceed with the next step. 5.2 When the following screen is displayed, click on the button to continue. If you want to use a destination directory different than the default one displayed on the screen, just click on Change Directory to locate the desired folder, and then click on button to continue. 11

5.3 You can change or use the default folder name displayed on the screen and then click on Continue to start copying files. 5.4 The following screen shows the copying progress. 12

5.5 When the installation is completed successfully, the following screen came, and presses the OK button will terminate the installation program. 13

6. Configuring The Ethernet Converter 6.1 Configuring With Ethernet Converter Setup Program 6.11 To start Ethernet Converter Setup program, click on Start Programs Ethernet Converter Utility Ethernet_Converter_Setup 6.12 The Ethernet I/O Setup window is shown as below. 6.13 Click on the button to search all the Ethernet Converter connected in the same subnet using the UDP broadcast protocol. When the search is finished, the information about all Ethernet Converters found will be listed in the text box as shown below. 14

6.14 Double click on the desired Ethernet Converters whose configuration is to be modified, as shown below. Double click on the desired Ethernet Converter 15

6.15 The following window is displayed after double click on the desired Ethernet Converter which allow user to modify the configuration of the selected Ethernet Converter. Please refer to the following description for setting up the parameters of the Ethernet Converter. Local IP: The IP address of the Ethernet Converter on the TCP/IP network. The default Local IP address is 192.168.192.250. This address should be unique. Ask your network administrator for assistance, if in doubt. Subnet mask: Identifying the network class which the Ethernet Converter belongs to. The default Subnet mask is: 255.255.255.0. Ask your network administrator for assistance, if in doubt. 16

Gateway IP: The IP address of the router. The default Gateway IP address is: 192.168.192.254. Ask your network administrator for assistance, if in doubt. DHCP client: If this option is enabled, that means the IP address, Subnet mask and Gateway IP address of the Ethernet Converter are set dynamically by the DHCP Server. If the setting cannot be got from the DHCP server successfully, the Ethernet Converter will use the last setup parameters for its configuration. The possible reason of this case is that the DHCP server is shutdown or not available. Ask your network administrator for assistance, if in doubt. SIO Port, Type: The local port number of the Ethernet Converter to be contacted by other devices. The default port number is 502, which is reserved for Modbus/TCP protocol that Ethernet Converter supports only. And default communication mode for Ethernet Converter is TCP Server, which made Ethernet Converter operate at the Passive or the TCP listen mode to receive TCP connection requests from the remote client device. Command Port: The Ethernet Converter supports the command mode, which user can use to setup the parameters or get the information of the Ethernet Converter with UDP protocol from the remote host. The default Command Port number is 65535. The command port of the Ethernet Converter should be set correctly while using the command mode. Please refer to appendix 1 for further information. Setup password: This password protects the Setup window of the Ethernet Converter from unauthorized entry. To erase an existing password, just leave the Setup password text box blank. Access password: If this password is configured, the remote host needs to send this access password one second periodically to the Check Status Port of the Ethernet 17

Converter, otherwise the data transfer request will not be accepted by the Ethernet Converter. To erase an existing password, just leave the Access password text box blank. 6.16 User must ensure the command port number that the Ethernet I/O Setup program used is the same as the Command Port parameter which has been configured in the Ethernet I/O setup window. To verify this, click on Option Command Port as shown below. Next, when the Command Port window opens, input the command port number that is the same as the one which has been set in the setup window, and then click on OK. 18

6.17 User needs to use the right password to enter the Ethernet I/O Setup window if password protection is enabled. Click on Option Password as shown below. When the Password window opens, input the correct password that is the same as the one which has been set in the setup window, and then click on OK. 19

6.18 To exit the Ethernet I/O Setup program, click on Option Exit as shown below. 6.19 To show the information about Ethernet I/O Setup program, click on Help About Ethernet I/O Setup as shown below. 20

And the About Ethernet I/O Setup window opens, view the description shown on the screen, and then click on OK. 6.2 Configuring With Web Browser 6.21 Start web browser and search the web site using the address: 21

http://192.168.192.250, which is the default IP address of the Ethernet Converter. The web page is shown as below. Click button to go into the configuration web page. Remember to key-in the password if authorized entry is required before you click button. 6.22 The configuration web page is shown below. Please refer to 5.1 for how to setup the related parameters of the Ethernet Converter. After setting the parameters, press the button to store the modified configuration. 22

23

6.23 Now the Ethernet Converter has been updated and the browser refresh to the login web page again. 24

Appendix 1: Command Mode Support Use the command mode to set up the Ethernet Converter, it needs an application software to handle these actions. Command X for Broadcast X or x Command Syntax : X <magic code> Magic code = 99.130.83.99 Return : AX <MAC Address> / <IP Address> / <Device ID> Example : Send out: X 99.130.83.99 Return : AX0.128.200.255.251.242/192.168.1.100/ABC Command G for getting Status G or g Command Purpose: Get the all parameters of the Web Server Syntax: G <MAC address> / <IP> / <Setup Password> Return : All parameters of the Web Server Example: Send out: G 0.128.200.255.251.242/192.168.1.100/12345678 Return: CG for Cancel or AG <All Messages> Command S for Web Server Parameters Setting S or s Command Purpose: Set the Parameters of the Web Server Syntax: S <MAC Address> / <IP> / <Setup Password> / <Parameter> / <Value> Return: A for Accept or C for cancel Example: Send Out: S Command R for restart R or r Command Purpose: Restart the Web Server Syntax: R <MAC address> / <IP> / <Setup Password> Return: AR for accept or CR for cancel Example: Send out : R 0.128.200.255.251.242/192.168.1.100/12345678 Return : AR or CR 25

Command M for MAC address Setting M Command, not for the User Purpose: Set the MAC address of the Web Server Format: M <Old MAC Address>/<New MAC Address>/ <Factory Password> Return: AM for accept or CM for cancel Command I for IP setting I Command, not for User. User should use the S Command for setting IP address. Purpose : Set the IP address by LAN broadcast Syntax: I <MAC Address>/<New IP>/ <Factory Password> Return: AI for accept or CI for cancel 26