NEW product No, NPPDF 6-01E Large digital sensor 31series SEU-31 Easily viewable LCD dual displays. igh level visibility with 3-color display 2-Color indications depending on output. Main display : Pressure value (Red or green) Sub-display : Set point (Orange) Compact body Compact body size of width 30 mm and height 30 mm. Opening dimension when multiple sensors are mounted. Dimension after mounted 31mm A 34.4mm n * Calculation Formula : (A)=(34.4 n)-3.4 n : Number of sensors 34.4mm Locking function is built in. Locking function prevents accidental output when pushing the key mistakenly. Key mark is when the function is active. Excellent cost performance Over 40% of cost cut was realized compared to Large digital sensor 30 series. Very reasonable large digital display sensor. Built in power saving mode reduces power consumption by 30% Unless any button is pushed during power saving mode, the main display automatically enters power saving mode in 30 seconds. Normal mode Unless any button is pushed at power saving mode, the main display enters power saving mode in 30 seconds. Power saving mode When main display is off, SLP, meaning sleep mode, blinks at sub-display. Pushing any button enables to return to normal mode.
13 NEW PRODUCTS Specif ication Model R-N -N SEU-31-N (Compound ) ( ) ( ) Rated range -100.0 ~ 100.0kPa -101.3 ~ 0.0kPa 0.000 ~ 1.000MPa Proof 300kPa 1.MPa Fluid type Air, Non-corrosive/non-inflammable gases kpa 0.1 - MPa - 0.001 (kgf/cm 2 ) 0.001 0.01 Pressure (bar) 0.001 0.01 resolution (psi) 0.01 0.1 (ing) 0.1 - (mmg) 1 - Power supply 12V~24VDC (Ripple voltage±10% or less) Consumption current 40mA or less (With no load) Switch output NPN open collector output Max. load current : 12mA Max. supply voltage : 30VDC Residual voltage : 1.V or less Repeatability ±0.2% F.S. ±1 digit or less One point set mode ysteresis ysteresis mode Window comparator mode Adjustable (*) Response time 2.ms or less (Update rate : 2ms, 100ms, 20ms, 00ms, 1000ms, and 100ms selections) Output short circuit protection Possible Digital indication 3-color indication (Red, green and orange) (Sampling rate : times/sec) Indication accuracy ±2%F.S. ±1digit or less (Ambient temp. at 2±3ºC) Indication for operation Orange, 1& 2 indicators Analogue output (Voltage output) Output voltage : 1 to V±2.%F.S. or less ( within rated range) Linearity :±1%F.S. or less, Output impedance 1kΩ Protective structure IP40 Ambient temperature limits At operation : 0 to 0ºC, At storage:-10 to 60ºC (No dew condensation and no freezing) Environment resistance Ambient humidity limits Withstand voltage Insulation resistance At operation and storage:3 to 8%R (No dew condensation) AC1000V for 1minute (Between a lead and case) 0MΩ or more(00vdc) (Between a lead and case) Vibration proof Total amplitude is 1.mm or 100m/s 2, 10z~10z~10z for 1min., 2 hours each direction of X, Y, and Z. Shock resistance 100m/s 2 3 times each in X, Y, and Z direction Temperature characteristics ±2%F.S. (at 2, Range 0~+0ºC) Cable spec. Oil proof cable (0.1mm 2 ) Note : ysteresis value is adjustable within 1 to 8 digits for one point set mode and window comparator mode. (Example) (1) (1).Model Code R SEU-31 Rated range -100.0 ~ 100.0kPa (Compound ) -101.3 ~ 0.0kPa ( ) 0.000 ~ 1.000MPa ( ) (2).Switch output Code Method N V 01 (2) (3) (4) (3).Switch specification N NPN Open collector Code V 2 Specification 1point SW output & Analogue output 2 points SW output (4).Connecting type & size Code 01 Type & size Outer diameter : Taper male thread R1/8 Inner diameter : Metric female thread Mx0.8 ().Cable length/connector spec. C () Code No code C Specification 2m cable With M8, 4 pins, Male connector Large digital sensor 31 series 2
Large digital sensor 31 series (Example) ACPG-31 (1) C42 (2) (1).Model ACPG-31:Large digital sensor 31 series accessory (2).Accessory type Code C42 B1 B2 P1 P2 Female connector Type (M8, 4pins) Female connector Bracket (Wall bracket, M3x male thread 2 pcs.) Bracket Wall bracket Large digital sensor 31 series accessory Bracket (Upright bracket, M3x male thread 2 pcs.) Upright bracket Panel adapter set without front protective cover (Front panel adapter, Back panel adapter) Panel adapter set Panel adapter set with front protective cover (Front protective cover, Front panel adapter, Back panel adapter) a. Front panel adapter b. Back panel adapter Type : ACPG-31-C42 Type : ACPG-31-B1 Type : ACPG-31-B2 c. Front protective cover Type (a + b) : ACPG-31-P1 Type (a + b + c) : ACPG-31-P2 Outer dimension R Compound type type SEU-31 type 1 21 30 23.9 39.4 R-NV-01 73 R-N2-01 73 -NV-01 73 -N2-01 73 SEU-31-NV-01 73 SEU-31-N2-01 73 30 R1/8 ex.12 M 0.8 Depth : 7 M8, 4 pins Male connector type R-C Compound type -C type SEU-31-C type R-NV-01-C 36 R-N2-01-C 36 -NV-01-C 36 -N2-01-C 36 SEU-31-NV-01-C 36 SEU-31-N2-01-C 36 1 21 30 39.4 23.9 10 M8, 4 pins Male connector type Pin layout 2 4 1 3 1: Brown (+) 2: White (OUT2 / Analogue output) 3: Blue (-) 4: Black (OUT1) 30 R1/8 ex.12 M 0.8 Depth : 7 3
13 NEW PRODUCTS Large digital sensor 31 series accessory ACPG-31-C42 M8, 4 pins Female connector type 32 7 M8 1 00 ACPG-31-C42 4 ACPG-31-B1 Wall bracket ACPG-31-B2 Upright bracket 12 4.2 4-ø4 4.2 29. 6 31 1.6 13 12.4 4 4-ø4 29. Front panel adapter Panel cutout dimension +0 34.4 4 31-0.4 Front protective cover 34.4 8. Panel cutout dimension +0 31-0.4 34.4 Back panel adapter 33 30.2 Panel thickness : 0.~4.mm Front panel adapter 34.4 4 33 30.2 34.4 34.4 1.6 4 ACPG-31-P1 Panel adapter set ACPG-31-B1 10 ACPG-31-B2 12 ACPG-31-P2 Panel adapter set with front protective cover Panel thickness : 0.~4.mm ACPG-31-P1 4 Back panel adapter 33 30.2 33 30.2 ACPG-31-P2 4
Large digital sensor 31 series Operation procedures & Function description [ ow to attach accessories ] [ Initial setting mode ] ow to attach bracket Wall bracket ACPB-31-B1 Upright bracket ACPB-31-B2 M3 0. Male thread (Attachment) M3 0. Male thread (Attachment) Push SET button for more than 3 seconds. OUT 1 operation mode Select a operation mode of out 1 by pushing Body Bracket Body or Bracket One point set mode ow to attach panel adapter set ACPB-31-P2 ACPB-31-P1 ysteresis mode Window comparator mode OUT 1 output type setting Set Out 1 output mode by pushing or Front protective cover N.C. (Normally closed) mode N.O. (Normally open) mode OUT 2 operation mode Front panel adapter Body Back panel adapter Off mode [ Electric diagram ] 1 point SW output + Analogue output Main circuit One point set mode ysteresis mode Set OUT2 output mode by pushing or *1 *3 Analog output Load (White) DC12-24V OUT (Black) Window comparator mode OUT 2 output type setting DC (+) (Brown) 1kΩ Select a operation mode of out 2 by pushing or *1 N.C. (Normally closed) mode N.O. (Normally open) mode Response time setting DC (-) (Blue) Set response time by pushing or 2 points SW output DC (+) (Brown) 2ms Main circuit Load OUT1 (Black) Load OUT2 (White) 100ms 20ms 00ms 100ms 1000ms 2.ms DC12-24V Indication color setting Set an indication color on the display by pushing or DC (-) (Blue) : Green : Red : Red : Green / : Green / : Red [ Display description ] Pressure unit display Pressure resolution setting Set resolution by pushing or 2-color main display (Red or green) Lock indicator Set value indicator Out 1 indicator Out 2 indicator UP button SET button DOWN button (kpa/mpa) (kgf/cm2) (bar) (psi) (ing) (*2) (mmg) (*2) *1.This mode is applied only for VUS(SEU)-31-N2- -. *2.This resolution is applied only for R and. *3.This setting mode is not when OUT 2 setting is.
13 NEW PRODUCTS [ Application setting mode ] [ Pressure setting mode ] Setting condition 1 : (One point setting mode) (Not used) Push SET button for more than seconds. ysteresis value setting Adjust hysteresis by pushing or.this function can be applied only for one point setting mode and window comparator mode. Setting condition 2 : (One point setting mode) (One point setting mode) Setting condition 3 : LCD display color setting Select a LCD indication color of OUT 1 or OUT 2 by pushing or *1 Power saving mode Select power saving mode by pushing or *2 (One point setting mode) (ysteresis mode) (Window comparator mode) Setting condition 4 : (ysteresis mode) (Window comparator mode) (Not used) Setting condition : Initializing setting Reset to factory default value by pushing or (ysteresis mode) (Window comparator mode) (One point setting mode) Setting condition 6 : OUT2 mode setting : (ysteresis mode) (Window comparator mode) (ysteresis mode) (Window comparator mode) Fine adjustment mode Select fine adjustment mode by pushing or. With indication at the sub-display, push SET button to set the mode. Refer to [ Fine adjustment mode ] (page.7) for setting. With indication at the sub-display, pushing SET button brings to measurement mode. * Note : When the sub-display is on and a set value blinks, do not turn off power. The system does not store the value. [ Power saving mode ] *1. This mode can be selected only for VUS(SEU)-31-N2- -. *2. When is on the sub-display, the power saving mode is on. 1.Unless any button is pushed during power saving mode, the main display automatically enters power saving mode in 30 seconds. 2.During power saving mode, slight difference may occur on indication. 3. Pushing any button brings back to measurement mode. No pushing a button brings to power saving mode in 30 sec. Pushing any button brings to measurement mode. Normal mode 6 Power saving mode When main display is off, SLP, meaning sleep mode, blinks at sub-display.
Large digital sensor 31 series [ Output type ] [ Setting zero value ] One point setting mode Normally open mode / Compound SEU-31 R P-1 P-2 P-1 P-2 [ Max/Min. value indication ] Normally closed mode / Compound SEU-31 R Push both SET and button together for more than 2 sec.. PE- : Max. value bo- : Min. value P-1 P-2 P-1 P-2 [ Button lock/unlock mode ] ysteresis mode Normally open mode / Compound SEU-31 R -1-2 1.Locking function mode prevents accidental output when pressing the key mistakenly. 2. Key mark is on the main display when the mode is active. -1-2 Push both SET and button together for more than 2 sec.. Normally closed mode / Compound SEU-31 R -1-2 Unlock mode -1-2 [ Fine adjustment mode ] -1-2 -1-2 Change a set value by pushing or. After the value is set, push SET button. Normally closed mode / Compound SEU-31 R -1-2 -1-2 *1. When hysteresis is set at 2 digits or less and if input is too close to set value, malfunction may be caused at sensor output. *2. If a difference between two setting points is below a fixed hysteresis at window comparator mode, switch output may not work. [ Analogue output ] Analogue output is proportional to range and becomes 1 to V. Compound Analogue output (V) Analogue output (V) Analogue output (V) 1 1 [ Error Indications ] Error name Over current error 0.0 100.0 (kpa) (igh) 0.0 (Low) -101.3 (kpa) (igh) 0.000 (Low) Error indication Description OUT1 Load current of OUT 1 is over 12 ma. OUT2 Load current of OUT21 is over 12 ma. Residual error Operation error Impressed exceeds max. of set value. Impressed is below min. of set value. System error 1.000 (MPa) (igh) Treatment Turn off the power and check causes of over current. After lower the load current to less than 12 ma, turn on the power again. Make the impressed at the level When setting zero clear, air should of air, and try zero clear setting be more than ±3%F. S. again. Inner system error 3 1 Pressure R. D (Real Detect value) * Fine adjustment ability ±0.1% RD ±2.% R.D. Default values indicate factory configured values. Setting range for values to indicate -100.0 (Low) This function removes slight error of output value and uniform values. Indicated value on sensor can be set within ±2.% R. D.. Fine adjustment mode is Lock mark Normally open mode / Compound SEU-31 R Lock mode Window comparator mode Indicated value At measurement mode, push and button together until 00 gets. When the buttons are released, setting zero value is finished. Inner data error Adjust the impressed within the operation range. Turn off the power once and turn it on again. If there is still a problem, contact to PISCO. 7
13 NEW PRODUCTS Detailed Safety Instructions Warning : 1. This product must not be used in gas or liquid where a corrosive substance is dissolved. 2. Make sure to use this product within rated range written in specification. If supply exceeds max. proof, damage of the product or malfunction may be caused. 3. Make sure to turn off power when connecting. 4. Wrong wiring may cause sensor damage, trouble and malfunction.. Do not use the product where water drop, oil drop or dust may fall. 6. This product is not designed to be explosion-proof. Do not use it in the environment where corrosive or explosive gas exists. Cautions: 1. When handling this product, do not drop it, hit it or give strong shock to it. 2. If the product is used in the same wiring route as the power lines or high voltage lines, it may cause a malfunction due to noise. Please use a separate wiring route. OVERSEAS MARKETING DEPARTMENT 3884-1 MINAMIMINOWA, KAMIINA, NAGANO-PREF., 399-488 JAPAN TEL : +81-(0)26-76-771 FAX : +81(0)26-76-330 URL : en.pisco.co.jp/ E-mail : intl@pisco.co.jp The specifications are subject to change without advance notice. 13.12.PDF