Quick reference guide 3D sensor O3D3xx

Similar documents
Brief instructions Illumination unit O3M950 O3M /00 03/2016

Brief instructions Mobile 3D sensor O3M150 O3M151 O3M160 O3M /00 03/2016

Brief instructions Illumination unit O3M /00 09/2014

Installation instructions Ethernet switch EC / / 2011

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions RFID evaluation unit DTE / / 2016

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Speed monitor D / / 2014

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Operating instructions ClassicLine module AC5203 / AC5205 AC5208 / AC5211 AC5213 / AC5214 AC5215 / AC5233 AC /00 02/2015

Installation instructions RF-identification system with integrated AS-i slave DTSLF / / 2010

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

Original operating instructions Safety relay with relay outputs G1501S / / 2016

Operating instructions Diagnostic electronics for vibration sensors VSE002 / VXE002 / VXE003 VYE001 / VYE002 / VYE003 / VYE /01 05/2015

Original operating instructions Fail-safe inductive sensor GG711S

Original operating instructions Fail-safe inductive sensor GI712S

Original operating instructions. Fail-safe SmartPLC with Profinet slave interface AC402S /00 06/2016

JUMO mtron T Measuring, Control, and Automation System

Operating instructions. Standstill monitor A / / 2011

Installation instructions Inclination sensor EC2019 EC / / 2013

Operating instructions Encoder PerformanceLine. RxP5xx /00 04/2018

Original operating instructions Photoelectric safety sensors (safety light grid) with active / passive system OY90xS

Operating instructions Optical distance sensor. OID25x / / 2015

Operating instructions Optical distance sensor. OID20x / / 2014

Operating instructions Optical distance sensor. OID20x / / 2015

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

Operating instructions Optical distance sensor. OID25x / / 2014

MC 11 EB-2 Power supply cabinet with external bus, AC version

Output Signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power Supply DC V, ±10%, 0.3 W

Operating instructions Evaluation system for flow sensors VS / / 2013

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

QUINT-BUFFER/24DC/24DC/40

TU531, TU532 Terminal Unit

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

SUBCON-PLUS-PROFIB...

RUC industrial relays of small dimensions

Compact universal controllers

Resistance measuring module

Operating instructions. ProcessLine analogue module AC / / 2012

Operating instructions RFID evaluation unit DTE / / 2011

Operating instructions Pressure sensor. PN50xx / / 2010

RUC-M industrial relays for DC loads

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

TF501, TF521 Terminal Bases

TXM1.8RB. TX-I/O Blinds module

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

Installation Guide. O2Vxxx / / 2015

Device manual Inclination sensor 2 axes JN /00 04/2015

Operating instructions. Monitor FD / / 2013

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Operating instructions IO-Link master CabinetLine AL19xx

AO523 Analog Input Module

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

About this Document 2 Symbols and Typographic Conventions... 2 Figures... 2 Downloading Manuals... 2

RUC industrial relays of small dimensions

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

AO561 Analog Output Module

Light Control SLS ADRIA

Actuators for air and gas dampers

Operating instructions. Monitor FS-2 / FS-2N / / 2013

SolConeX extra-low voltage flange socket

CPCI-PS24 24V-Power Supply

Operating instructions Electronic temperature sensor TN /00 04/2011

LXM32SD18M2 motion servo drive - Lexium 32-single phase supply voltage 115/230V - 0.5/1.kW

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

PHOENIX CONTACT - 07/2006

Inductive sensor BI5-EM18-Y1X-H1141

Installation Job Aid for Ethernet Routing Switch 3600 Series

Output signal active note. Output signal. temperature DC V, DC V DC V, DC V DC V

BW-108. Building Wash BW-108. User Guide. Advanced LED Technology

Operating instructions. Monitor FR-1 / FR-1N / / 2013

Redundancy unit CP-A RU

Output Signal. Temperature 22DTH-56M BACnet DC V, DC V. Electrical Data Power Supply DC V, ±10%, 0.7 W

Operating instructions Programming and display unit PP / / 2010

AI561 Analog Input Module

MINI-PS AC/10-15DC/8

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X-H1341

Operating instructions Vortex flow meter. SVxxx / / 2015

PanelView Plus/VersaView CE Terminals and Display Modules

DC541 Digital Input/Output Module

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

Device manual Profibus encoder. RM30xx RN30xx /00 06/2013

Electromotoric actuators Torques up to 60 Nm Running times ¹) s. ¹) Predefined by the basic unit (LMV5...)

JUMO Quantum PID100/PID200/PID300

AX522 Analog Input/Output Module

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

Datasheet - RSS 36-D-R-ST

AX521 Analog Input/Output Module

Inductive sensor NI3-EG08K-Y1-H1341

Operating instructions Optical distance sensor. O5D15x / / 2014

Inductive sensor BI1.5-EG08-Y1-H1341

CM597 Ethernet Communication Module

AI531 Analog Input Module

TEMPERATURE AND HUMIDITY TRANSDUCER P18 TYPE USER S MANUAL

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Transcription:

Quick reference guide 3D sensor O3D3xx 80271080 / 00 11 / 2017

Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...4 2.1 Safety note...4 3 Functions and features...4 4 Items supplied...5 5 Accessories...5 6 Installation...6 6.1 Mounting accessories...6 7 Electrical connection...7 7.1 Wiring...9 8 Approvals/standards...9 2

1 Preliminary note This document is intended for specialists. These specialists are people who are qualified by their appropriate training and their experience to see risks and to avoid possible hazards that may be caused during operation or maintenance of the device. The document contains information about the correct handling of the device. Read this document before use to familiarise yourself with operating conditions and installation. Keep this document during the entire duration of use of the device. For a detailed description of the device please read the operating instructions and the programming manual. 1.1 Symbols used Instructions > Reaction, result [ ] Designation of keys, buttons or indications Cross-reference Important note Non-compliance may result in malfunction or interference. Information Supplementary note 1.2 Warnings used NOTICE Warning of damage to property. 3

2 Safety instructions These instructions are part of the device. They contain texts and figures concerning the correct handling of the device and must be read before installation or use. Note the safety instructions. Use the device in accordance with its designated use. The installation and connection must comply with the applicable national and international standards. Responsibility lies with the person installing the device. Only the signals indicated in the technical data or on the device label may be supplied to the connections or wires. The unit may only be opened by the manufacturer or by a person authorised by the manufacturer. 2.1 Safety note NOTICE IR light emitted from this product. Classification acc. CEI/IEC 62471:2006 Exempt group 3 Functions and features The O3D3xx 3D sensor is a photoelectric sensor measuring the distance between the sensor and the nearest surface point by point using the time-of-flight principle. The sensor illuminates the scene with an infrared light source and calculates the distance by means of the light reflected from the surface. From the image data, process values are generated via internal image processing and compared to threshold values. The comparative and process values are linked to the digital outputs. This allows to solve the following applications: Completeness monitoring Level monitoring Distance monitoring Dimensioning of rectangular objects 4

Sorting of rectangular objects The measured data and process values can be provided via Ethernet and evaluated by the user. Parameter setting of the sensor is also done via Ethernet. The sensor may only be used under the operating conditions specified in the data sheet. The sensor safety is rated for use under the following operating conditions: Indoor use Altitudes up to 2000 m Relative air humidity up to max. 90 %, non condensing Pollution degree 3 Because of the requirements for electromagnetic interference emissions the sensor is intended for use in industrial environments. The sensor is not designed for use in domestic areas. The sensor may only be used under the environmental conditions specified in the data sheet. 4 Items supplied O3D3xx 3D sensor Brief instructions The device is supplied without installation and connection accessories. 5 Accessories The following accessories are needed for the operation of the device: Description Power supply cable for camera/sensor M12 industrial Ethernet connection cable Article no.: E11950 E11898 The ifm Vision Assistant software is available free of charge on our website www.ifm.com. 5

6 Installation During installation note the following: Use cables with strain relief. A B A Keep area "A" clear of objects. Position the object to be detected ("C") closer to the device than any other objects within area "B". C Mount the camera so that the focus adjustment screw is freely accessible with a screw driver. If the device is permanently used in wet areas, the nut of the M12 Industrial Ethernet cable (e.g. E11898) may corrode. Use a cable with a high-grade stainless steel nut for permanent use in wet areas. 6.1 Mounting accessories Depending on the place and type of installation, you can use the following mounting accessories: Description Smart Camera mounting set Smart Camera cooling element Smart Camera heat conductor 2x Smart Camera cooling element Article no.: E3D301 E3D302 E3D303 E3D304 You can find more information about the accessories at www.ifm.com. 6

7 Electrical connection NOTICE Depending on the operating mode, the unit may heat up. The difference between the unit's surface temperature and the ambient temperature may not exceed 25 degrees. Take one or several of the following measures: Adjust the operating mode. Make sure the unit is sufficiently cooled (e.g. with cooling element and heat conductor). Use a contact protection. NOTICE The unit must be connected by a qualified electrician. Camera of protection class III (PC III) The electric supply must only be made via PELV circuits. Electric supply must comply with UL61010-1, chap. 9.4 - Limited Energy. The separation of external circuits must comply with UL61010-2-201, fig. 102. Disconnect power before connecting the unit. ATTENTION The IP rating given in the data sheet is only guaranteed if the M12 connectors are firmly screwed. The unit can be damaged by insufficiently tightened M12 connectors. Firmly screw the M12 connectors to the unit. For the scope of validity culus: Minimum temperature rating of the cable to be connected to the field wiring terminals: 70 C. Cover the unused sockets with protective caps (E73004). Tightening torque 0.6...0.8 Nm. 7

1 2 4 3 2 1 8 3 7 4 6 5 3 1 2 4 5 6 7 8 1 + DC 24 V - IN IN IN OUT OUT 2 PLC 3 8

7.1 Wiring (1) Ethernet M12 socket, D-coded, 4 poles 1 2 4 3 S (2) Power supply 1 TD + 2 RD + 3 TD - 4 RD - S Shield M12 connector, A-coded, 8 poles 2 1 3 7 4 5 6 8 1 U+ 2 trigger input 3 GND 4 switching output 1 (digital or analog) 5 switching output 3 ready 6 switching output 2 (digital) 7 switching input 1 8 switching input 2 You can find more information about the accessories at www.ifm.com. 8 Approvals/standards The EU Declaration of Conformity can be downloaded at www.ifm.com. 9