IB IL 24 DI 16 IB IL 24 DI 16-PAC

Similar documents
IBS IL 24 BK RB-T-2MBD

IB IL 120 DI 1. Function. INTERBUS Inline Terminal With One Digital Input in the 120 V AC Voltage Area. Data Sheet 5764B

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

IBS IL 24 RB-LK-2MBD:

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

IB IL IB IL PAC

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

IB IL 24/48 DOR 2/W-XC-PAC

This data sheet is only valid in association with the IL SYS INST UM E user manual.

VersaPoint I/O Module

ILB DN 24 DI16 DO16. Inline Block IO Module for DeviceNet With 16 Digital Inputs and 16 Digital Outputs. AUTOMATIONWORX Data Sheet 6885_en_05

IB IL RS 232 IB IL RS 232-PAC

IB IL AO 2/SF... Inline terminal with two analog outputs. AUTOMATION Data sheet 6655_en_06. 1 Description

PB IL 24 BK DIO 16/16

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description

PHOENIX CONTACT - 10/2006

IBS ST (ZF) 24 BK LB-T

ILC 200 IB ILC 200 IB-PAC

VersaMax IP I/O Module

IBS PCI SC/I-T. Controller Board for PC Systems With PCI Bus. Data Sheet 6039B

IL CAN BK-TC-PAC. Extract from the online catalog. Order No.:

VersaMax IP Input Module

AXL E IOL AO1 U M12 R

Rexroth Inline terminal with one analog output

GFK-2415A March Type of sensor connection

PHOENIX CONTACT - 11/2008

IBS ST 24 BK-T INTERBUS-S. Data Sheet. Bus Terminal Module. Product Description

ILB BT ADIO 2/2/16/16

IL CAN BK-TC-PAC. Extract from the online catalog. Order No.:

PSI-MODEM-SHDSL/SERIAL

VERSAMAX IP PROFINET SCANNER. 1 Description. GFK-2760 June 2012

8 24 V DC, 8 24 V DC,

MINI-PS AC/10-15DC/8

PHOENIX CONTACT - 10/2009

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

MINI MCR-SL-UI-2I(-SP)(-NC)

PHOENIX CONTACT - 07/2006

Redundancy Module QUINT-DIODE/40

ASI QUINT /2.4 EFD

FL SWITCH SFN 5TX. Extract from the online catalog. Order No.:

Rexroth RECO Fieldline INTERBUS Devices

MINI MCR-SL-PT100-UI(-SP)(-NC)

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

PHOENIX CONTACT - 05/2007

PI-EX-ME-2NAM/COC-24VDC

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

PHOENIX CONTACT Features

PHOENIX CONTACT - 12/2007

DEK-OV- 5DC/ 24DC/ 3. Extract from the online catalog. Order No.:

PHOENIX CONTACT - 07/2005

PI-EX-ME-2NAM/COC-120VAC

FL MC 2000E (SM40) LC

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

IB IL EX-IS TEMP 4 RTD/TC-PAC

IB IL EX-IS AIO 4/EF-PAC

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

QUINT-PS/ 1AC/24DC/ 5

AXL E EC DI16 M12 6P. Axioline E EtherCAT device, plastic housing, 16 inputs, 24 V DC, M12 fast connection technology. Data sheet.

Extract from the online catalog

IL CAN BK-TC-XC-PAC. Inline CANopen bus coupler Extreme conditions version. Data sheet _en_01. 1 Description

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

TRIO-DIODE/12-24DC/2X10/1X20

AXL E PN DI8 DO8 M12 6P

PSR UC/ESAM4/3X1/1X2/B

DPO A4. Description. Module with 4 digital outputs. Datasheet

FL SWITCH Factoryline 5- and 8-port managed switches with optional fiber optic ports and wide temperature ratings. Data sheet.

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:

QUINT-PS-3x AC/24DC/10

AXL E PB DIO16 M12 6P

PSI-MODEM-SHDSL/PB. Broadband PROFIBUS extender, SHDSL PROFIBUS leased line modem. Data sheet _en_03. 1 Description. 1.

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

PHOENIX CONTACT - 11/2008

Extract from the online catalog

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

MINI MCR-SL-PT100-UI-200

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:

PSR DC/ESP4/2X1/1X2

Extract from the online catalog

RSTI-EP Slice I/O Digital Input Modules EP-1214, EP-1218, EP-1318, EP-125F, EP-1804 Digital Input Module with Time Stamp EP-12F4

Power Supply HARTING pcon

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

PSI-MOS-RS422/FO 850 T

Power Supply HARTING pcon

QUINT-PS/24DC/48DC/ 5

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

QUINT-BUFFER/24DC/24DC/40

ABL8RPS24100 regulated SMPS - 1 or 2-phase V - 24 V - 10 A

Automation terminals of the Inline product range. User manual

This data sheet is only valid in association with the GFK-2736 user manual.

RSTI-EP Slice I/O. Digital Output Module

PHOENIX CONTACT - 01/2007

ABL8REM24050 regulated SMPS - 1 or 2-phase V AC - 24 V - 5 A

ABL8WPS24400 regulated SMPS - 3-phase V - 24 V - 40 A

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Valueline Industrial PC

Transcription:

IB IL 24 DI 16 IB IL 24 DI 16-PAC Inline Terminal With 16 Digital Inputs Data Sheet 555302 06/2003 + Features This data sheet is only valid in association with the IB IL SYS PRO UM E User Manual or the Inline System Manual for your bus system. Items IB IL 24 DI 16 and IB IL 24 DI 16-PAC only differ in the scope of supply (see Ordering Data on page 11). They have the same functions and technical data. For reasons of simplification the designation IB IL 24 DI 16 will be used in the following. Connections for 16 digital sensors Connection of sensors in 2 and 3-wire technology Maximum permissible load current per sensor: 250 ma Maximum permissible load current from the terminal: 4.0 A Diagnostics and status indicators Function The terminal is designed for use within an Inline station. It is used to acquire digital input signals. N + Figure 1 IB IL 24 DI 16-PAC terminal 555302 1

Local Diagnostic and Status Indicators Des. Color Meaning,, 1 D Green Diagnostics Each connector 1, 2, Yellow Status indicators of the inputs 3, 4 Terminal Assignment for Each Connector Terminal Point Assignment 1.1, 2.1 Signal input (IN) Figure 2 IB IL 24 DI 16 terminal with an appropriate connector Function Identification Light blue ) * N + 1.2, 2.2 Segment voltage U S for 2 and 3-wire termination 1.3, 2.3 Ground contact (GND) for 3-wire termination 1.4, 2.4 Signal input (IN) 1.5, 2.5 Segment voltage U S for 2 and 3-wire termination 1.6, 2.6 Ground contact (GND) for 3-wire termination % & & % & & % & & % & & % & & % & & ' ) % Figure 3 Terminal point numbering when using individual connectors (A) and when using a connector set (B) 2 555302

Internal Circuit Diagram? = > K I 2 + 7 & & & & 8 7 5 - / 8 7 1 1 * Figure 4 Internal wiring of the terminal points Key: OPC Protocol chip (bus logic including voltage conditioning) LED (status indicator) Optocoupler Digital input Electrically isolated area Other symbols used are explained in the IB IL SYS PRO UM E User Manual or in the Inline System Manual for your bus system. 555302 3

Connection Notes and Example Please note that the terminal must be provided with supply voltage U S, as this is used internally as the auxiliary supply. When connecting the sensors observe the assignment of the terminal points to the process data, see page 5.,, 1 1 1 1 1 1 ' 1 1 1 ) 1 8 1 1 1 % 1 & 1 1 1 1 8 1 * ) 1 8 8 1 ) ' Figure 5 Sensor connection example A 3-wire termination B 2-wire termination The numbers shown above the module indicate the connector slots. 4 555302

Programming Data/Configuration Data INTERBUS ID code BE hex (190 dec ) Length code 01 hex Process data channel 16 bits Input address area 1 word Output address area 0 bytes Parameter channel 0 bytes (PCP) Register length (bus) 1 word Other Bus Systems )RUSURJUDPPLQJGDWDFRQILJXUDWLRQ GDWDIRURWKHUEXVV\VWHPVSOHDVH UHIHUWRWKHFRUUHVSRQGLQJHOHFWURQLF GHYLFHGDWDVKHHW*6'('6) Process Data For the assignment of the illustrated (byte.bit) view to your INTERBUS control or computer system, please refer to the DB GB IBS SYS ADDRESS data sheet, Order No. 90 00 99 0. For the assignment of the illustrated (byte.bit) view to control systems of other bus systems, please refer to the AH IB IL 24 DI/DO ADDRESS document, Order No. 90 14 12 4. 555302 5

Assignment of the Terminal Points to the IN Process Data Word The following table applies to the IB IL 24 DI 16-PAC terminal with the original connector set and when using the connector sets IB IL DI/DO 16-PLSET or IB IL DI 16-PLSET/ICP (see also Figure 3 on page 2, part B). (Byte.bit) Byte Byte 0 Byte 1 view Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Module Slot 4 3 2 1 Terminal point 8.47.48.17.16.45.46.15.14.43.44.13.12.41.42.11.1 (signal) Terminal point 8.57.58.27.26.55.56.25.24.53.54.23.22.51.52.21.2 (+24 V) Terminal point 8.67.68.37.36.65.66.35.34.63.64.33.32.61.62.31.3 (GND) Status Slot 4 3 2 1 indicator LED 4 3 2 1 4 3 2 1 4 3 2 1 4 3 2 1 (Word.bit) view The following table applies when using the connectors IB IL SCN-12 or IB IL SCN-12-ICP (see also Figure 3 on page 2, part A). Word Word 0 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 (Byte.bit) Byte Byte 0 Byte 1 view Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Module Slot 4 3 2 1 Terminal point 2.41.42.11.12.41.42.11.12.41.42.11.12.41.42.11.1 (signal) Terminal point 2.51.52.21.22.51.52.21.22.51.52.21.22.51.52.21.2 (+24 V) Terminal point 2.61.62.31.32.61.62.31.32.61.62.31.32.61.62.31.3 (GND) Status Slot 4 3 2 1 indicator LED 4 3 2 1 4 3 2 1 4 3 2 1 4 3 2 1 6 555302

Technical Data General Data Order designation (Order No.) IB IL 24 DI 16 (27 26 23 0) IB IL 24 DI 16-PAC (28 61 25 0) Housing dimensions (width x height x depth) Weight Operating mode Transmission speed Type of sensor connection Permissible temperature (operation) Permissible temperature (storage/transport) Permissible humidity (operation) 48.8 mm x 120 mm x 71.5 mm (1.921 in. x 4.724 in. x 2.815 in.) 122 g (without connectors) Process data operation with 1 word 500 kbaud 2 and 3-wire technology -25 C to +55 C (-13 F to +131 F) -25 C to +85 C (-13 F to +185 F) 75% on average, 85% occasionally In the range from -25 C to+55 C (-13 F to +131 F) appropriate measures against increased humidity (> 85%) must be taken. Permissible humidity (storage/transport) 75% on average, 85% occasionally For a short period, slight condensation may appear on the outside of the housing if, for example, the terminal is brought into a closed room from a vehicle. Permissible air pressure (operation) Permissible air pressure (storage/transport) 80 kpa to 106 kpa (up to 2000 m [6562 ft.] above sea level) 70 kpa to 106 kpa (up to 3000 m [9843 ft.] above sea level) Degree of protection IP 20 according to IEC 60529 Class of protection Class 3 according to VDE 0106, IEC 60536 Interface Local bus Through data routing 555302 7

Power Consumption Communications power Current consumption from the local bus Power consumption from the local bus Segment supply voltage U S Nominal current consumption at U S 7.5 V DC 60 ma, maximum 0.45 W, maximum 24 V DC (nominal value) 4 A, maximum Supply of the Module Electronics and I/O Through Bus Terminal/Power Terminal Connection method Through potential routing Digital Inputs Number 16 Input design According to EN 61131-2 Type 1 Definition of switching thresholds Maximum low level voltage U Lmax < 5 V Minimum high level voltage U Hmin > 15 V Common potentials Segment supply, ground Nominal input voltage U IN 24 V DC Permissible range -30 V < U IN < +30 V DC Nominal input current for U IN 3 ma, minimum Delay time None Permissible cable length to the sensor 30 m (98.43 ft.) (to ensure conformance with EMC Directive 89/336/EEC) Use of AC sensors AC sensors in the voltage range < U IN are limited in application (corresponding to the input design) 8 555302

Characteristic Curve: Current Depending on the Input Voltage and the Ambient Temperature T A Supply Input Current Input Current According to t >= 20 s Voltage With T A = 25 C (77 F) With T A = 55 C (131 F) 18 V 3.0 ma 2.9 ma 2.5 ma 24 V 3.9 ma 3.8 ma 3.5 ma 30 V 4.5 ma 4.2 ma 3.0 ma The current is reduced depending on the ambient temperature T A and the number of inputs that are switched on (module internal temperature). Power Dissipation Formula to Calculate the Power Dissipation of the Electronics 2 J J 9 Σ7 1 N ) Where P tot Total power dissipation in the terminal n Index of the number of set inputs n = 1 to 16 U INn Input voltage of the input n Power dissipation of the housing P HOU 2.8 W, maximum (within the permissible operating temperature) Concurrent Channel Derating Derating Safety Equipment Overload in segment circuit Surge voltage Polarity reversal None No Protective circuits of the power terminal Protective circuits of the power terminal 555302 9

Electrical Isolation/Isolation of the Voltage Areas To provide electrical isolation between the logic level and the I/O area, it is necessary to supply the station bus terminal and this digital input terminal from separate power supply units. Interconnection of the power supply units in the 24 V area is not permitted. (See also the User Manual.) Common Potentials 24 V main voltage, 24 V segment voltage, and GND have the same potential. FE is a separate potential area. Separate Potentials in the System Consisting of Bus Terminal/Power Terminal and I/O Terminal - Test Distance - Test Voltage 5 V supply incoming remote bus/7.5 V supply (bus logic) 500 V AC, 50 Hz, 1 min. 5 V supply outgoing remote bus/7.5 V supply (bus logic) 500 V AC, 50 Hz, 1 min. 7.5 V supply (bus logic)/24 V supply (I/O) 500 V AC, 50 Hz, 1 min. 24 V supply (I/O)/functional earth ground 500 V AC, 50 Hz, 1 min. Error Messages to the Higher-Level Control or Computer System None 10 555302

Ordering Data Description Order Designation Order No. Terminal with 16 digital inputs IB IL 24 DI 16-PAC 28 61 25 0 with connectors and labeling fields Terminal with 16 digital inputs IB IL 24 DI 16 27 26 23 0 Four of the connectors listed below or one connector set are needed for the complete fitting of the IB IL 24 DI 16. Connector with 12 spring-cage connections (green, without color print); pack of 10 Connector with 12 spring-cage connections (green, with color print); pack of 10 Connector set with 48 spring-cage connections (green, without color print) Connector set with 48 spring-cage connections (green, with color print) Configuring and Installing the INTERBUS Inline Product Range User Manual Phoenix Contact GmbH & Co. KG Flachsmarktstr. 8 32825 Blomberg Germany + 49 - (0) 52 35-3-00 + 49 - (0) 52 35-3-4 12 00 www.phoenixcontact.com Worldwide Locations: www.phoenixcontact.com/salesnetwork IB IL SCN-12 27 26 34 0 IB IL SCN-12-ICP 27 27 61 1 IB IL DI/DO 16-PLSET 28 60 97 6 IB IL DI 16-PLSET/ICP 28 60 98 9 IB IL SYS PRO UM E 27 43 04 8 0ake sure you are always working with the latest documentation published. It is available on the Internet at www.phoenixcontact.com. Phoenix Contact 06/2003 Technical modifications reserved TNR 94 23 18 3 11 555302