SUN2000 (8KTL-28KTL) Quick Installation Guide. Issue: 14 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.

Similar documents
SUN2000 (8KTL-28KTL) Quick Installation Guide. Issue: 13 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.

SUN2000-(33KTL, 40KTL) Quick Installation Guide. Issue: 05 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.

SUN2000-(33KTL-A, 36KTL, 42KTL) Quick Guide. Issue: 03 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.

SUN KTL-M0 Quick Guide (Europe Edition) Issue: 01 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.

SUN2000-(2KTL-5KTL)-L0. Quick Guide. Issue: 01 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.

SUN2000-(55KTL, 60KTL) Series Quick Guide. Issue: 03 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.

SUN KTL-USH0 Quick Guide. Issue: 01 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.

SUN2000-(33KTL, 36KTL, 40KTL)-US Quick Guide (Mounting Bracket Supplied with the SUN2000, Amphenol Helios H4)

SmartLogger1000 Quick Guide. Issue: 10 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.

SUN KTL-US-HV-D0 Quick Guide. Issue: 01 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.

String Inverter (SUN2000-8/12KTL)

SmartLogger2000 Quick Guide. Issue: 01 Part number: Date: HUAWEI TECHNOLOGIES CO., LTD.

Huawei Solar Product Training HUAWEI TECHNOLOGIES CO., LTD.

SUN2000 (8KTL-28KTL) User Manual. Issue 09. Date HUAWEI TECHNOLOGIES CO., LTD.

SUN2000-(25KTL, 30KTL)-US. User Manual. Date HUAWEI TECHNOLOGIES CO., LTD.

SmartACU2000B Smart Array Controller Quick Guide (with PID Modules, 800 V AC)

SUN2000-(55KTL, 60KTL) Series. User Manual. Issue 05. Date HUAWEI TECHNOLOGIES CO., LTD.

SmartACU2000B Smart Array Controller Quick Guide (with no PID Module, 800 V AC) Issue: 05 Part Number: Date:

SUN2000-(33KTL, 36KTL, 40KTL)-US. User Manual. Issue 01. Date HUAWEI TECHNOLOGIES CO., LTD.

SUN2000-(33KTL, 36KTL, 40KTL)-US. User Manual. Issue 04. Date HUAWEI TECHNOLOGIES CO., LTD.

SmartPSB2000L Smart PV Safety Box Quick Guide. Issue: 03 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.

SUN2000-(33KTL-A, 36KTL, 42KTL) User Manual. Issue 03. Date HUAWEI TECHNOLOGIES CO., LTD.

SUN KTL-US-HV-D0. User Manual. Issue 01. Date HUAWEI TECHNOLOGIES CO., LTD.

FP-PS-4. Features. Installation

FusionSolar Smart PV Solution

Three Phase Residential Solution for Australia, System Design and Installation Guidelines

TCNM-ACBB1 Installation Manual

Huawei USA Inc. was founded in 2001 and has 10 branch offices, 7 R&D Centers and TAC center with 700 employees.

ISMG Solar Inverter. General Description. Type Selection. Ordering Key ISMG 1 50 EN. Approvals RD 1663/2000 RD 661/2007 DK5940 VDE

SUN2000-(2KTL-5KTL)-L0. User Manual. Issue 01. Date HUAWEI TECHNOLOGIES CO., LTD.

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

Huawei FusionHome Smart Energy Solution

Cat. No. S012-EN-01. Ilumen PIDbox INSTALLATION MANUAL

INSTALLATION GUIDE. AXIS 291 1U Video Server Rack ENGLISH FRANÇAIS DEUTSCH ITALIANO ESPAÑOL

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

FusionSolar Smart PV Solution

BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide

modlink msdd Front panel interfaces

Electrical Integration of PV Systems. Ridha Hamidi, Ph.D.

Han R 23. Circular Connector. Certified acc. to DIN EN ISO 9001 in design/ development, production, installation and servicing.

About Huawei. A Global Leader of ICT Solutions

Installing the Camera

SmartLogger1000. User Manual. Issue 09. Date HUAWEI TECHNOLOGIES CO., LTD.

Photoelectric Sensor

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

User Manual. Solar Inverter for Water Pump

IST ULTRASTAB Power Supply for IT/ITN ULTRASTAB transducers

Smart Energy Center. Simple & Easy. Higher Revenue. Battery Ready. Safe & Reliable

DRH Hardware Maintenance Guide

IST ULTRASTAB Power Supply for high precision transducers


F1000 User's Manual. (Version: V1.01)

User Manual. 2.2KW/7.5KW/11KW Solar Inverter for Water Pump. Version: 1.8

Instructions. (For 6180 Industrial Computers) Applications. Overview & Safety

Solis Single Phase Inverter

User Manual. 2.2KW LS (Low PV Input Range) Solar Inverter for Water Pump. Version: 1.1

DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E

PV Inverter SUNNY BOY 2000HF / 2500HF / 3000HF

Datasheet. Inv erter Model. Input. Max. DC Power [W] Max. DC Voltage [V] Max. Input Current [A] MPP Voltage Range (Full Load) [V] Numbers of MPPT

Warning Before Installation. Package Contents EN - 1. Refer to your user's manual for the operating temperature.

Sunny Boy 2100TL Transformerless solar inverter Installation Guide

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Installing the DX LCD Display

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

PV Grid-Connected Inverter

Short manual for the installation of the PIKO solar inverter

GRID-TIED SOLAR INVERTER 1.5KW ~ 6.0KW V.1.2

PV Inverters SUNNY TRIPOWER 15000TL Economic Excellence SUNNY TRIPOWER 20000TL Economic Excellence

GSV-1A4 M12/2 M12/2. Highlights

Package Contents. GP Options (Made by Digital)

ILUMEN PID SOLUTION INDOOR OUTDOOR ILUMEN PIDBOX MINI INSTALLATION MANUAL. Ilumen PIDbox mini Version 1.5

NI CB-37F-LP. Introduction INSTALLATION GUIDE. Connector Block for 37-Pin D-Sub Devices

IF-80x Outdoor Terminal

Applications

Adapter Kit - QSI Electronics to G-Series Meter Installation Instructions

Bring The Sun Home. Comfort and savings with our residential and commercial inverters.

GCI-5K INSTALLATION AND OPERATOR S MANUAL

1. Carefully unpack the um260 s shipping carton and check the contents for damage.

EGIL Circuit breaker analyzer

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

EGIL Circuit breaker analyzer

AC/DC (120V) Input Module Cat. No IAD Series C

XW3B. Connector Terminal Boxes. Ratings and Specifications. Compatible Connectors. Materials and Finish

FusionSolar. Residential Smart PV Solution. FusionSolar

B&W RearView Camera Installation & Operation

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Warning Before Installation. Package Contents EN - 1. Refer to your user s manual for the operating temperature.

PV Grid Connected. PRIce LIST valid from 1st Januar 2014 by Steca

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Product Manual ASL Document Ref.: U doc Issue: 04 complete, approved - Date: 16/08/10 Part Number: M0618_23

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

GTI 300W GTI 500W GTI 600W GTI 800W GTI 1000W


Installation Guide. Retrofit Kit for USB Ready Intraoral Systems

Instructions. (For 6180 Industrial Computers) Installing a Processor Upgrade

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

VLT Line Filter MCC 107 EMC Filter Series VLT Midi Drive FC 280 (K1 K3)

Warning Before Installation

Grid PV Inverter M30A & M50A. The power behind competitiveness Delta M30A & M50A. Product Features

Solis Three Phase Inverter

Transcription:

SUN2000 (8KTL-28KTL) Quick Installation Guide 0 Issue: 14 Part Number: 31044 Date: 2017-03-20 HUAWEI TECHNOLOGIES CO., LTD.

NOTICE 1. Before you install the devices, closely read the SUN2000 (8KTL-28KTL) User Manual to get familiar with product information and precautions. To locate the user manual, log in to http://support.huawei.com/carrier/ and browse or search for SUN2000 on the Product Support page. 2. Use insulated tools. Inverter Model SUN2000-8KTL/10KTL/12KTL SUN2000-1KTL/17KTL/20KTL/23KTL/28KTL 1 System Installation Determine the installation position. Weight 40 kg 48 kg Unit: mm Install the SUN2000 in a position where the liquid crystal display (LCD) is easy to view and operate. Vertical Backward Forward Horizontal Upside down 1 Copyright Huawei Technologies Co., Ltd. 2017. All rights reserved.

Installing an Inverter (support-mounting is used as an example) 1. Determine the hole positions on the support based on rear panel dimensions. Unit: mm 2. Drill holes. 3. Secure the rear panel. 4. Mount the inverter on the rear panel. M10 (3 PCS) 30 N m. Tighten hexagon bolts. 6. (Optional) Install an anti-theft lock. NOTE 1. The antitheft lock is prepared by customers. 2. For details about wall-mounting the device, see the SUN2000 (8KTL-28KTL) User Manual. 2

2 Electrical Connection 1. Install a ground cable. OT-6mm 2 -M6 PE terminal NOTE 1. It is recommended that the ground cable be connected to a nearby ground position. 2. To enhance the corrosion resistance performance of the PE terminals, apply silica gel on them after connecting the ground cable. 2. Install AC output power cables. Inverter Model SUN2000-8KTL/10KTL/12KTL SUN2000-1KTL/17KTL/20KTL/23KTL/28KTL Cross-sectional Area of the Cable (Recommended) 4.0 mm 2 (12 AWG) 6.0 mm 2 (10 AWG) / 10.0 mm 2 (8 AWG) NOTE The table lists only the recommended cable specifications. For more information about cable specifications, see the SUN2000 (8KTL-28KTL) User Manual. NOTICE 1. Do not use solid conductor hard cables. 2. 3-core outdoor cables (L1, L2, L3) are configured for the SUN2000-28KTL and 4-core outdoor cables (L1, L2, L3, and N) are for other models. 3

Socket Cable sealing cover NOTICE The N cable is inserted into hole 4. Do not insert L1/L2/L3 into. Auxiliary connector Large handle screwdriver (recommended) Notch Click NOTE To quickly connect the AC output connector to the AC output terminal of the inverter, keep the notch of the connector facing exactly to the operator. NOTICE Ensure that the AC output connector is securely connected. Otherwise, the connector may be damaged after the inverter has been running for a long time. 3. Install DC input power cables. Optional DC input terminals: Number of Inputs 1 8KTL-12KTL Connects to any one route 1KTL-28KTL Connects to any one route 2 Connects to routes 1 and 3 Connects to routes 1 and 3 3 Connects to routes 1, 2, and 3 Connects to routes 1, 3, and 4 Connects to routes 1, 2, 3, and 4 Connects to routes 1, 2, 3, and 6 N/A Connects to routes 1, 2, 3, 4, and N/A Connects to routes 1, 2, 3, 4,, and 6 4

Positive and negative metal terminals: Positive metal terminal (female) Negative metal terminal (male) Positive metal terminals Negative metal terminals Common PV cables with a crosssectional area of 4 mm²in the industry are recommended. Recommended: H4TC0001 (Amphenol) Ensure that cables cannot be removed after crimped. Positive connector The skid automatically starts after the ejector lever is fastened. Recommended: H4TW0001 (Amphenol) Negative connector Click NOTICE 1. Pull back the DC input power cables to check whether the cables would be disconnected. 2. If DC input power cables are reversely connected and the DC switch is ON, do not turn off the DC switch immediately. Otherwise, the equipment may be damaged. You can disconnect the DC input power cable on the PV string side or wait until the PV string voltage reduces to a value within the safety range. Then, turn off the DC switch, remove the positive and negative connectors, and rectify the connection.

4. Install an RS48 communications cable. The side without buckles RJ4 connector with Plastic shielding base functions Matching nut Sealing washer Cable sealing nut No. Color Pin Definition 1 2 White and orange Orange 3 White and green PGND 4 Blue RS48A, and RS48 differential signal+ RS48B, and RS48 differential signal- RS48A, and RS48 differential signal+ White and blue RS48B, and RS48 differential signal- 3 4 Installation Verification 1. Check that all screws, especially the screws used for electrical connections, Passed Failed are secured. 2. Check that all circuit breakers are switched to OFF. Passed Failed 3. Check that the ground cable is securely connected and no short circuit occurs. 4. Check that AC output power cables are connected correctly and securely (the N wire is connected to hole 4, and L1/L2/L3 can be connected to any hole of 1/2/3; for details, see 2.2 Install AC output power cables), with no short circuit.. Check that DC input power cables are connected correctly and securely, with no short circuit. System Power-on 1. Switch on the AC circuit breaker between the SUN2000 and the. 2. Ensure that the DC Switch at the bottom of the SUN2000 is ON. 3. (Optional) Measure the temperatures at the joints between the DC terminals and the connectors. Setting Monitoring Parameters 6 Green PGND 7 White and brown PGND 8 Brown PGND Passed Failed Passed Failed Passed Failed 6. Ensure that idle DC input terminals are sealed. Passed Failed 7. Check that the idle USB and RS48 ports are plugged with waterproof plugs. Passed Failed 1. If no data collector is used, set the following parameters before connecting the SUN2000 to the. For the other parameter settings, see the SUN2000 (8KTL-28KTL) User Manual. If a data collector is used, see the SmartLogger1000 User Manual for the parameter settings. 2. The preset password for Common User, Advanced User, and Special User is 000001. Use the preset password to log in to the SUN2000 for the first time and then change the password to a new one to ensure the account security. 6

Main Menu Second- Level Menu Third-Level Menu Fourth-Level Menu Setting Wizard Language - - Set based on site requirements. Date&Time Date - Set based on site requirements. Time - Set based on site requirements. Grid Code - - China medium-voltage, choose CHINA-MV480. China low-voltage, choose NB/T 32004. Main Menu Settings Isolation(Ad Input Grounded, With vanced User) TF Input Ungrounded, Without TF Input Ungrounded, With TF For other cases, see the Appendix. When the PV- is grounded, an isolation transformer should be connected. Set Isolation to Input Grounded, With TF. When the PV- is not grounded, set Isolation to Input Ungrounded, Without TF or Input Ungrounded, With TF. 7

Appendix: Power Grid Standard Code Mapping Table No. Power Grid Standard Code Country and Condition No. Power Grid Standard Code Country and Condition 1 CHINA-MV480 China medium-voltage 24 IEC61727-MV480 IEC medium-voltage power 2 NB/T 32004 China low-voltage 2 VDE 0126-1-1-BU 3 UTE C 1-712- 1(A) France low-voltage power 26 VDE-AR-N-410 Bulgaria low-voltage power Germany low-voltage power 4 6 7 UTE C 1-712- 1(B) UTE C 1-712- 1(C) UTE C 1-712-1- MV480 G9-England- MV480 8 G9-England 9 G9-Scotland 10 G83-England 11 G83-Scotland Islands of France 230 V 0 Hz Islands of France 230 V 60 Hz France medium-voltage UK 480 V Medium-voltage (I > 16 A) England 230 V (I > 16 A) Scotland 240 V (I > 16 A) England 230 V (I < 16 A) Scotland 240 V (I < 16 A) 27 BDEW-MV480 28 BDEW-MV 29 TAI-PEA 30 TAI-MEA 31 TAI-PEA-MV480 32 TAI-MEA-MV480 33 EN 0438-DK Germany medium-voltage Germany medium-voltage (400 V AC) Thailand low-voltage power (PEA) Thailand low-voltage power (MEA) Thailand medium-voltage (PEA) Thailand medium-voltage (MEA) Denmark medium-voltage 34 Japan(0Hz) Japan (0 Hz) 12 CEI0-21 Italian low-voltage 3 Japan(60Hz) Japan (60 Hz) 13 CEI0-16 Italian medium-voltage 36 EN0438-TR- MV480 Turkey medium-voltage power 14 IEC61727 IEC low-voltage 37 EN0438-TR Turkey low-voltage 1 16 VDE 0126-1-1- GR(A) VDE 0126-1-1- GR(B) 17 EN0438-CZ 18 RD1699 19 RD661 20 AS4777 21 AS4777-MV480 22 NRS-097-2-1 23 NRS-097-2-1- MV480 Mainland of Greece lowvoltage Islands of Greece lowvoltage Czech Republic low-voltage Spanish low-voltage power (Pn < 100 kw) Spanish low-voltage power (Pn > 100 kw) Australia low-voltage power Australia medium-voltage South Africa low-voltage South Africa medium-voltage 38 C10/11 39 C11/C10-MV480 40 Philippines 41 Philippines- MV480 42 EN0438-NL 43 Custom(0Hz) Reserved 44 Custom(60Hz) Reserved 4 46 Custom-MV480 (0Hz) Custom-MV480 (60Hz) Belgium low-voltage power Belgium medium-voltage Philippines low-voltage power Philippines medium-voltage Netherlands low-voltage power Reserved Reserved NOTE Grid codes are subject to change. The listed codes are for your reference only. 8

HUAWEI TECHNOLOGIES CO., LTD. Huawei Industrial Base Bantian Longgang Shenzhen 18129 People's Republic of China www.huawei.com 9