HT Series Wall Mount with Relay Setpoints, LCD, and Humidistat and Thermostat Control

Similar documents
HT Series Wall Mount with Analog Setpoints, LCD, and Humidistat and Thermostat Control

HWS Series Wall Mount with Relay Setpoints, LCD, and Humidistat Control

Schneider Electric s SCD series of duct mount sensors measure the levels of CO 2. , RH (if equipped) and temperature of air inside a duct.

CDD4 Series Room CO2 Transmitter Installation Instructions

CDD4 Duct Carbon Dioxide Transmitter

BA/BS4S Temperature Sensor Installation & Operating Instructions

AIR QUALITY/ GAS DETECTION

NEUROLOGIC RESEARCH CORPORATION MODEL 2500

CDD Carbon Dioxide Transmitter

ON/OFF HUMIDIFIER CONTROL (ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET OVERVIEW WALL CONTROLLER INSTALLATION (TCY-BH-T-U)

CDR-RH Room CO 2, Temperature and Humidity Sensors (Controllers)

EPWR Series. RoHS. Product Description. Available Products. Installation Instructions 01

PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION!

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

LAUREL ELECTRONICS, INC.

LLR-MOD Modbus Light Level and Occupancy Sensor

TOXALERT MODEL AIR 2000

MOD-RI Room Interface Modules with Modbus

NSGV Series "90DM3" Carbon Dioxide Detector

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

Precision humidity/temperature control/sensing

TC-9102 Series Surface Mount Temperature Controllers

Instruction Manual CTC-1

Measure & Control Temperature & CO2 levels with analog & digital I/O

Temperature Measurement

Microprocessor based Temperature / CO2 Controller c/w 365 Day Time Switch & Modbus Communication.

SERIES 59. Microprocessor Temperature Controller with Digital Display and RTD, Thermistor or Thermocouple Sensing

SmartX Living Space Sensors

NT50 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat

THERMOSTATS & CONTROLLERS

Millennium Simplicity Elite Parameter Points and Quirks

+GF+ SIGNET Conductivity/Resistivity Transmitter Instructions

H7625A, H7635A Humidity/Temperature Sensors

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

! Ranges from -45º to 650ºC. ! Rapid heating, cooling and settling. ! Switch test, ramp, step and preset functions

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

Model 305e OEM CO 2 concentration sensor

HygroFlex HF3 Transmitters and Thermohygrostats: User Guide

CONTROL MICROSYSTEMS Analog Output Module. Hardware Manual

Zone Pressure Touch (ZPT) Sensor with Attached Tube (-AT) - Low Pressure Range Unit Installation and Operation Instructions

Installation Guide. Room Temperature Sensors. Mounting. Location and Cover Removal (All) STE-6011 Only. STE-6010/6013/6015 Only

Analyzer/Controller. ph/orp HART. Model 54e ph/orp ESSENTIAL INSTRUCTIONS WARNINGS RISK OF ELECTRICAL SHOCK

MODEL: R2K-1 SEN TRONIC AG. R2K Series

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

TEMPERATURE CONTROLLER 2 HEAT/ 2 COOL with Digital Room Temperature Display. Made in Australia 100% Australian Owned Company

Millenium II +: general characteristics

Model CD-AW. Infrared Environmental CO2 Sensor. Operator's manual

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

Trident and Trident X2 Digital Process and Temperature Panel Meter

MOD-IO9 Modbus Input / Output Modules, Wall Mounted

3690 N.W. 53rd Street Fort Lauderdale, FL SC-2124 SC-2124M. 24 Channel Universal Scanner. Installation and Operation Manual P/N 145F-11902

UCU Room Display. Operation Modes. Features. Applications DATASHEET

C7110C1001A / C7110D1009A WALL MODULES

2001VT Temp & CO 2. - air quality sensor/controller NOTE!!! Manual for Installation. General. SenseAir AB

Model HU-224/225. Technical Information TI.224/ Humidity Transduce r FOR ADDITIONAL INFORMATION SEE HU-224/225 DATA SHEET

Installation Guide. Carbon Dioxide (CO 2. ) Detectors. General Information. Mounting WARNING CAUTION. SAE-1011/1012 Space Mount SAE-1011/1012/1062

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

Atmos Engineering, Inc. External Specification PN PC104 Air Data Atmodule PN Revision 6.0

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02

Zone Pressure Touch (ZPT) Sensor - Standard Range

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS

SP6R Level Controller Operation Manual

TER-MOD Active Room Temperature Sensors (Controllers) with Modbus

+GF+ SIGNET ph/orp Transmitter Instructions

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

H7625B; H7635B,C; H7655B Duct-Mount and Outdoor-Mount Humidity/Temperature Sensors

Fast Route to Reliable Energy Savings ZIP Economizer

Operation and Maintenance Manual

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.

Zone Pressure Touch Sensor - Standard Range

Isolated Linearized RTD Input 5B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

X47.CE Product Guide

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

LED55WPG Programmable LED Driver

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

Basic Temperature and Limit Controllers

DIGITAL PANEL THERMOMETER

CAEL-DP Series Dew Point Transmitter for Industrial Control

RXTP ROOM TEMPERATURE

HE-6800 Series Humidity Transmitters with Temperature Sensor

DIGITAL PANEL THERMOMETER

4-step Chiller and Heat Pump Controller

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Custom Controller Installation Instructions

Basic Temperature and Limit Controllers. Provide Economical Solution for a Wide Range of Applications SPECIFICATION SHEET

Installation and Operation Guide

ECON-ZIP-BASE. ZIP Economizer Base Unit. Wiring Diagram USA CANADA LATIN AMERICA / CARIBBEAN

Operating Instructions Differential Pressure Transducer PS27

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

RТTH DUAL ROOM SWITCH

Installation and Operation Instructions I/CO 2, I/CO 2 -VDC, I/CO 2 -T

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

S025W-056C W Programmable LED Drivers

TS InteliSwitch Digital Time Switch 24VDC/VAC

CDR Room CO 2 and Temperature Sensor with Modbus

Tempco Instruction Manual

Free Energy Band RCC30U Room Temperature Controller for Four-pipe Fan Coil Unit

DataNab it8: Intelligent Communicating Thermostat

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Transcription:

Wall Mount with Relay Setpoints, LCD, and Humidistat and Thermostat Control NOTICE This product is not intended for life or safety applications. Do not install this product in hazardous or classified locations. Read and understand the instructions before installing this product. Turn off all power supplying equipment before working on it. The installer is responsible for conformance to all applicable codes. No responsibility is assumed by Veris Industries for any consequences arising out of the use of this material. Product Overview The HT relay series has dual outputs to measure temperature and humidity of the air inside a room. They are designed for use in hospital rooms, laboratories, and other spaces that require precise environmental control. Two separate relays control the setpoints for heating and cooling when in thermostat mode or humidifying and de-humidifying when in humidistat mode. The slide switch position determines the output type (amp or volt). To maintain accuracy, keep vents clear of dust, debris, etc. The HT is warranted for period of five years. Product Identification HT Accuracy 1 = 1% 2 = 2% 3 = 3% 5 = 5% NIST N = NIST (1 & 2% only) X = No (2, 3, 5% only) Setpoint R = Relay S = CE Temp Cal Certificate 0 = None 1 = 1 point Cal Validation 2 = 2 point Cal Validation Option B = 100R Platinum, RTD C = 1k Platinum, RTD D = 10k T2, Thermistor E = 2.2k, Thermistor F = 3k, Thermistor G = 10k CPC, Thermistor H = 10k T3, Thermistor I = 1k Balco (nickel-iron) RTD J = 10k Dale, Thermistor K = 10k w/11k shunt,thermistor M = 20k NTC, Thermistor N = 1800 ohm TAC, Thermistor Q = 1uA/C, Linitemp R = 10k US, Thermistor S = 10k 3A 221, Thermistor T = 100k, Thermistor U = 20k D, Thermistor W = 10k T2 high accuracy, Thermistor Y = 10k T3 high accuracy, Thermistor Z = 10k E1, Thermistor CC= 15k, Thermistor Z202979-0U Page 1 of 7 2014 Veris Industries USA 800.354.8556 or +1.503.598.4564 / support@veris.com 02141

Specifications Input Power Outputs Setpoint Relays RH Sensor* RH Accuracy at 25 C from 10-80% RH** (Multi-point Calibration NIST traceable) Reset Rate Stability Hysteresis Deadband Linearity Operating Range Temperature Coefficient Operating Temperature Range Temperature Accuracy 15 to 30VDC/24VAC, 100mA max. Switch-selectable amp or volt (switch affects both temp and humidity outputs) If volt is selected, the configuration menu allows selection between 0-5V or 0-10V 2 Form C (SPDT), 1A 30VDC, resistive, 30W max Digitally profiled thin-film capacitive (32-bit mathematics) U.S. Patent 5,844,138 ±1% at 12-40% RH in ma output mode; ±1% at 30% RH in voltage output mode 24 hours ±1% @ 20 C (68 F) annually, for two years RH: 1.5% (typical) RH: 1 to 10% in 1% increments Temp: 1 to 10 F or 1 to 5 C in 1 increments Included in Accuracy spec. 0-100% RH (non-condensing) ± 0.1%RH/ C above or below 25 C (typical) 10 to 35 C (50 to 95 F) ± 1.0 C ( ± 1.8 F) Analog Output Scaling RH: 0-100% RH; Temp: 10 to 35 C (50 to 95 F) or 0 to 50 C (32 to 122 F) menu selectable Calibration Offset Setpoint Range RH: Adjustable ±9.9% in 0.1% increments; Temp: Adjustable ±9.9 (C or F) in 0.1 increments RH: 10-80% RH in 1% increments; Temp: Minimum to Full Scale in 1 increments * The HS sensing element has a 1-year warranty. The element is not a part of the 5-year product warranty. ** Accuracy is specified with 24 VDC supplied power with rising humidity. Reset Rate is the time required to recover to 50% RH after exposure to 90% RH for 24 hours. If the 0 to 50 C (32 to 122 F) scaling range is selected, the device s operating temperature range still applies. One side of the transformer secondary is connected to the signal common, so an isolation transformer or dedicated power supply may be required. RTD/Thermistors in wall packages are not compensated for internal heating of the product. EMC Special Note: Connect this product to a DC distribution network or an AC/DC power adaptor with proper surge protection (EN 61000-6-1:2007 specification requirements). Dimensions 4.75" (121 mm) - + 3.5" (89 mm) 1.2" (29 mm) Z202979-0U Page 2 of 7 2014 Veris Industries USA 800.354.8556 or +1.503.598.4564 / support@veris.com 02141

Installation Observe precautions for handling static sensitive devices to avoid damage to the circuitry that is not covered under the factory warranty. 1. Locate the tab at the top of the sensor housing. Using only the minimum required force, press this tab down and pull the cover outward from the top. Set the cover aside. Tab Housing, Top View 2. Remove the backplate by unfastening the sensor from the bottom of the backplate and pivoting the sensor outward. 3. Punch out wire opening in the backplate. 4. Position the backplate vertically on the wall, 4 ½ feet (1.4 m) above the floor. Locate away from windows, vents, and other sources of draft. If possible, do not mount on an external wall, as this might cause inaccurate temperature readings. 5. Mount the backplate onto the wall using the screws provided. Five screwholes available; use a minimum of two for secure mounting. Z202979-0U Page 3 of 7 2014 Veris Industries USA 800.354.8556 or +1.503.598.4564 / support@veris.com 02141

Installation (cont.) 6. Wire the backplate. RH Output Temp output Thermistor/RTD Thermistor/RTD POWER SOURCE 15 to 30VDC or 24VAC + - GND Heat/Hum. Alarm Comm Alarm Cool/De-Hum. Alarm DIGITAL CONTROL RH Input Temp Input Thermistor/RTD Input Thermistor/RTD Input Heat/Humidify Alarm Comm alarm Cool/De-Humidify Alarm - 7. Install and configure the sensor. RH TEMP RH YES/NO Jumper: YES - allows user to change RH setpoint NO - user can NOT change RH setpoint YES NO AMP VOLT YES Minus Select + Plus NO RUN CAL TEMP YES/NO Jumper: YES - allows user to change temp setpoint NO - user can NOT change temp setpoint RH SENSOR NOTICE TEMP SENSOR RISK OF EQUIPMENT DAMAGE. Ensure that the output selection is correct before applying power. Failure to follow these instructions may result in permanent equipment damage. 8. When the installation is complete, replace the cover and snap it into position. RUN/CAL Jumper: CAL Mode - allows full access to all features. RUN Mode - allows access to relay setpoints ONLY. Z202979-0U Page 4 of 7 2014 Veris Industries USA 800.354.8556 or +1.503.598.4564 / support@veris.com 02141

Calibration Instructions 1. Temperature calibration allows for a calibration offset of ±9.9 (C or F), at the user s discretion. 2. Relative humidity allows for a calibration offset of ±9.9% RH, at the user s discretion. RH and temperature can be field calibrated by moving the RUN/CAL jumper to the CAL position. Operation Instructions - + Display screen Scroll down Select Scroll up Normal Operation NORMAL MODE 4 5. 5 % R H 6 8. 5 º F Temperature Selection Use the (+) and (-) buttons to scroll to the Thermostat mode: 7 0 F Press +/- to change the setpoint value. When the desired setpoint appears, press the Select button to select. The setpoint is in C if Celsius units are selected. Selection Use the (+) and (-) buttons to scroll to the Humidistat mode: 4 5 % R H Press +/- to change the setpoint value. When the desired setpoint appears, press the Select button to select. Z202979-0U Page 5 of 7 2014 Veris Industries USA 800.354.8556 or +1.503.598.4564 / support@veris.com 02141

Menu Options NORMAL MODE 4 5. 5 % R H 6 8. 5 º F CONFIG/CAL MODE (Enter by any keypress when Run/Cal jumper is in CAL position) U N I T S * º F º C R E L A Y S * R H T 4 5 % R H - OR - 7 0 F Setpoint in C if Celsius units are selected. D E A D B A N D 5 % R H D E A D B A N D 4 F Deadband in C if Celsius units are selected. C A L T + 0. 0 F Setpoint in C if Celsius units are selected. C A L R H + 0. 0 % Output Scaling (does not affect LCD display) Only for switch in Volts position T E M P S E T + 5 0 + 9 5 Options are 10 to 35 C (50 to 95 F) or 0 to 50 C (32 to 122 F). O U T P U T 0-1 0 V Z202979-0U Page 6 of 7 2014 Veris Industries USA 800.354.8556 or +1.503.598.4564 / support@veris.com 02141

Replacing the HS Element Observe precautions for handling static sensitive devices to avoid damage to the circuitry that is not covered under the factory warranty. 1. Disconnect power to the unit. 2. Remove the faceplate. 3. Remove the HS element by gently pulling from the pin connector. 4. Place a new HS element onto the pin connector. Orient as shown, or the unit will not function. Ensure that the four HS pin holes are inserted fully onto the unit pin connectors. Top Side 5. Replace the faceplate. Bottom Side Z202979-0U Page 7 of 7 2014 Veris Industries USA 800.354.8556 or +1.503.598.4564 / support@veris.com 02141