Option H10, Multi-line 2 unit with USB service port. To be used when the multi-line 2 unit service port is USB type

Similar documents
DEIF A/S. Description of options. Option C1 Generator add-on protection package Multi-line 2 version 2. Description of options. Functional description

DEIF A/S. Description of options. Option C2, Generator add-on protection package Automatic Gen-set Controller. Description of option

DEIF A/S. Description of options. Option P1, Event and alarm printer Automatic Gen-set Controller. Description of option. Functional description

Compact Genset Controller, CGC 400 What's in the delivery? The first steps Push-buttons and LEDs

Option X4 Additional Operator Panel AOP-2 Description of option Functional description

Getting started - USW 3.x Software download from internet Software installation Device setup Data backup

Option P1 Event and alarm printer Description of option Functional description Parameter list

AGC 200 Advanced Gen-set Controller What s in the delivery? Getting started The first steps Using the AGC 200

QUICK START GUIDE Generator Paralleling Controller, GPC-3 Generator Protection Unit, GPU-3/GPU-3 Hydro Paralleling and Protection Unit, PPU-3

APPLICATION NOTES H-coupling

DEIF A/S. Description of options. Option A and B, Loss of mains protection package Automatic Gen-set controller. Description of options

Advanced Graphical Interface, AGI 100

MULTI-LINE 2 DESCRIPTION OF OPTIONS

Automatic Genset Controller, AGC-3 What's in the delivery Getting started The first steps Using the AGC

Automatic Genset Controller, AGC-4 What s in the delivery? Getting started The first steps Using the AGC

APPLICATION NOTES Translations

Automatic Genset Controller, AGC-4 What s in the delivery? Getting started The first steps Using the AGC

Inverter Interface Interface examples Wiring examples Communication topology

CODESYS v. 2.3, Ethernet driver for AGI 3xx Use the CODESYS Ethernet driver in the AGI Creator Set up the CODESYS for use with the AGI Creator

DEIF A/S. Description of options. Option H4 Serial comm. CAT CCM communication Multi-line 2 version 2. Description of option Functional description

APPLICATION NOTES DELOMATIC 4, DM-4 GAS/HYDRO

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

MULTI-LINE 2 APPLICATION NOTES

MULTI-LINE 2 APPLICATION NOTES. Converting PPU-2 to PPU-3 Parameter conversion Wiring Options I/O list. Document no.: A SW version:

QUICK START GUIDE Paralleling and Protection Unit PPU 300

Genset control and protection with safety system

Option H8.x and H12.x External I/O modules Description of option Functional description

OPERATOR'S MANUAL Generator Paralleling Controller, GPC-3 - Generator Protection Unit, GPU-3/GPU-3 Hydro - Paralleling and Protection Unit, PPU-3

QUICK START GUIDE Paralleling and Protection Unit PPU 300

QUICK START GUIDE Generator Protection Unit GPU 300

Option M2 Configurable engine control cards Multi-line 2 version B SW version 2.4X.X

APPLICATION NOTES. Advanced Graphical Interface - AGI Internal PLC (CODESYS V3) SHENDONG

Option H3 Serial communication Profibus DP

Introduction. 1 available USB type A (downstream) port. Windows 98, Windows ME, Windows 2000, Windows XP,

EAP 300 REMOTE ANNUNCIATOR INSTALLATION MANUAL. r.0454a

USB to Serial Converter User s Guide

MC-12 Software Installation Instructions

Operating manual. GTL - Configuration tool. Please keep the manual for future use.

Compact Genset Controller, CGC 200 Mounting Terminals and wiring Commissioning, using the Utility Software and/or the front panel

Software Kit. Automatic Door Controls. SIDOOR Software Kit. Introduction 1. General safety instructions. Installation. Uninstalling the software 4

USB/PPI+ Programming Cable Driver Procedure. Setting Guideline

> EME GUARD. Installation Guide. Date : Our reference :

General Information 1. Connection 2. User Interface 3 ATC5300. Menus 4. Automatic Transfer Controller. Remote Control Software Manual A5E

INTRODUCTION...1. Under Windows 98SE... 2 Under Windows ME... 6 Under Windows Under Windows XP...10

USB/PPI Programming Cable Driver Procedure. Setting Guideline

Data setting software MEXE02

USB to Serial Cable Hardware and USB Driver Installation instructions

MS6174 Data Adaptor (USB type) Software Manual

Product Manual. 8-Port RS-232 USB to Serial Adapter Data Control Box. Coolgear, Inc. Version 1.1 September 2017 Model Number: USB-8COM

USB DRIVER INSTALLATION GUIDE

8 Port USB to RS- 232/422/485 Octal Adapter. Product Manual. Coolgear, Inc. Version 1.1 April 2018 Model Number: USB-8COMi-RM.

DriveWizard Plus Instruction Manual

FX-USB-AW/FX3U-USB-BD. USER'S MANUAL USB Driver Installation Edition

Model No user manual

Application Note (Revision NEW) Original Instructions EGCP-3 LS Using an EGCP-3 in a Single-Phase Zig Zag Generator Application

for Energy and Power meters AEM and APM with Modbus interface

St ar 1: : : : : : : : : version 5, modified

Product Manual. 2 Port USB to RS-422 /485 Optical Isolated Adapter. Coolgear, Inc. Version 1.1 March 2018 Model Number: USB-2COMi-Si-M

Installation Manual. Multi Power Controller MPC-1 multi-line D

Serial Adaptor Isolated USB to TTL Device Driver - Installation Guide 1 Introduction. 2 Installing the Device Driver Software (Windows XP )

Product Manual. Single Port RS-232 USB Serial Adapter Optical- ISO Surge Protection. Coolgear, Inc. Version 1.1 March 2018 Model Number: USB-COM-Si-M

SIMATIC. Process Control System PCS 7 VT Readme V8.2 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

Copyright December 2017 Nidec Issue: D

- 15G0078B130 - USB MODULE INSTRUCTIONS FOR ASAC-0/ASAC-1/ASAB

USER S MANUAL USB TO Serial Adapter

Product Manual. USB 2.0 to Serial High- Speed RS-232 Industrial Adapter. Coolgear, Inc. Version 1.1 September 2017 Model Number: USB-COM-M

Software Manual Virtual COM for Ethernet Driver / Configuration Tool

TSXCUSBMBP USB Modbus Plus Communications Adapter User Manual eng

Serial PC Card. guide. Model MAN QIG

Model No user manual PRO

Registering Your D1 with the System (Windows 2000)

Serial 2-Port ExpressCard

USB Card Reader (UISA2SE) User's Guide

USB TO SERIAL CONVERTER

USB to RS-232/RS422/485. US-101-I USB To Serial Operation Manual

Input Power Selector Switch. Product Manual (Revision NEW) Original Instructions for use with Generator Set Control Assembly

Firstly, to perform the following actions, you must have Admin Rights on your PC.

MF9300. Software setup guide

Installing LE History Record Reader program software.

Cyber 2S1P 950 PCI Quick Installation Guide

CyberSerial 4S PCI Quick Installation Guide

Leica IP C and IP S. Printer Driver Software For the Windows 8.1 (32/64 bit) and Windows 10 (64 bit) operating systems

Cyber 2S1P 950 PCI Quick Installation Guide

APPLICATION NOTES. HEADING INDICATOR SYSTEMS using XDi-N indicators. Document no.: A

Datalogger and RS232 Interface

3700 SERIES USER MANUAL

USB COMMUNICATIONS INTERFACE LOOP LINK Contents. Side 1. Page 15. Page 29. Seite 43

USER MANUAL for USB 2.0 Card Bus

MULTI-LINE 2 DESCRIPTION OF OPTIONS. Option N Modbus TCP/IP SMS/ alarms NTP time synchronisation. Document no.: D SW version:

MULTI-LINE 2 DESCRIPTION OF OPTIONS. Option N Modbus TCP/IP SMS/ alarms NTP time synchronisation. Document no.: C SW version:

! Hardware: USB-Serial adapter, USB type A to type B cable. Software: USB-Serial driver on CD-ROM

SEIKA. Braille Display. User s Manual V3 Pro Version 1.0

USB Serial Converter

SOFTWARE SETUP GUIDE DIGITAL MULTIFUNCTIONAL SYSTEM

User manual Quick start TSwin.net

efesotomasyon.com - Lenze Manual Global Drive PC system bus adapter 2173 / 2177 Software installation & configuration

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

MULTI-LINE 2 APPLICATION NOTES. Converting PPM-2 to PPM-3 Parameter conversion Wiring Options I/O list Modbus. Document no.: A SW version:

Basic Gen-set Controller G (UK) SW version 2.1X.X. Terminal strip overview

Transcription:

Description of options Option H10, Multi-line 2 unit with USB service port 4189340418A To be used when the multi-line 2 unit service port is USB type DEIF A/S Hardware option DEIF A/S, Frisenborgvej 33 Tel.: +45 9614 9614, Fax: +45 9614 9615 DK-7800 Skive, Denmark E-mail: deif@deif.com, URL: www.deif.com

Table of contents 1. WARNINGS AND LEGAL INFORMATION... 3 LEGAL INFORMATION AND RESPONSIBILITY... 3 ELECTROSTATIC DISCHARGE AWARENESS... 3 SAFETY ISSUES... 3 DEFINITIONS...3 2. DESCRIPTION OF OPTION... 4 3. WIRING... 5 4. COMPUTER DRIVER INSTALLATION... 6 5. FINDING THE COM PORT NUMBER OF THE USB CONVERTER ON YOUR COMPUTER... 12 6. ADJUSTING THE USB COMMUNICATION PORT PARAMETERS ON YOUR COMPUTER... 14 7. HOW TO CHANGE THE COM PORT NUMBER (IF REQUIRED)... 15 8. CONFIGURATION OF THE DEIF MULTI-LINE 2 UTILITY SOFTWARE... 16 9. HOW TO UNINSTALL THE DRIVER ON YOUR COMPUTER (IF REQUIRED)... 17 DEIF A/S Page 2 of 18

1. Warnings and legal information Legal information and responsibility DEIF takes no responsibility for installation or operation of the generator set and transformer. If there is any doubt about how to install or operate the generator/transformer set controlled by the unit, the company responsible for the installation or the operation of the set must be contacted. The units are not to be opened by unauthorised personnel. If opened anyway, the warranty will be lost. Electrostatic discharge awareness Sufficient care must be taken to protect the terminals against static discharges during the installation. Once the unit is installed and connected, these precautions are no longer necessary. Safety issues Installing the unit implies work with dangerous currents and voltages. Therefore, the installation should only be carried out by authorised personnel who understand the risks involved in working with live electrical equipment. Be aware of the hazardous live currents and voltages. Do not touch any AC measurement inputs as this could lead to injury or death. Definitions Throughout this document a number of notes and warnings will be presented. To ensure that these are noticed, they will be highlighted in order to separate them from the general text. Notes The notes provide general information which will be helpful for the reader to bear in mind. Warnings The warnings indicate a potentially dangerous situation which could result in death, personal injury or damaged equipment, if certain guidelines are not followed. DEIF A/S Page 3 of 18

2. Description of option This document describes how to install the USB driver on a PC that will run the DEIF multi-line 2 utility software linked to a multi-line 2 unit by means of a USB cable. Product features Supports the RS232 serial interface Supports windows 98/se/me/2000/xp System requirements IBM PC 486DX4-100 MHz CPU or higher or compatible system Available USB port CD-rom drive All the installation instructions must be followed. When the installation is completed, you can connect the USB cable (delivered by DEIF when ordering a multi-line 2 unit equipped with a USB type service port) to a multi-line 2 unit (see the wiring description on the next page) and power up the multi-line 2 unit. USB is an abbreviation of Universal Serial Bus. More detailed information is available from the Universal Serial Bus Internet homepage at: www.usb.org. DEIF A/S Page 4 of 18

3. Wiring When receiving a multi-line 2 unit equipped with a USB service port (instead of db9 type), you will find a USB cable (A to B type, length 3 m) and a CD-rom (containing the USB PC driver). USB cable (A to B type) delivered by DEIF. The B type end must be connected to the multi-line 2 USB service port. The A type end must be connected to the USB socket of the computer. B male type A male type Types A and B are standard, defined by the USB specification. More detailed information is available from the Universal Serial Bus Internet homepage at: www.usb.org. DEIF A/S Page 5 of 18

4. Computer driver installation Follow the steps below to install the USB driver on the computer. The following screen dumps are based on a Windows XP system, which is the most used PC system in the world today. Other PC systems are not explained here. However, if you are using another PC system, it will be quite similar. Power up your computer and make sure that the USB port is enabled and working properly. Important: Do not connect the USB cable between the computer and the multi-line 2 unit. First the DEIF multi-line 2 utility software must be installed (this software can be downloaded free of charge from the DEIF web page at: www.deif.com). At the end of the installation process of the DEIF multi-line 2 utility software, the window below will appear, and the USB driver installation will begin. Press the Install button, and all the useful installation files will be copied to your PC on your C:\ drive (hard disk), at: :\Program Files\deif\CP210x. This window appears : Press the Continue anyway button several times for proceeding with this installation process. DEIF A/S Page 6 of 18

Finally, this message will be shown: Press the OK button. Finally you can check that all the files below are now present on your PC in the right folder. Now the USB cable must be connected between the computer and the multi-line 2 unit service port. The window below appears: Select the No, not this time option, and then press the Next button. DEIF A/S Page 7 of 18

Select the automatic installation (first option) and press Next. This window appears : Press the Continue anyway button for proceeding with this installation process. DEIF A/S Page 8 of 18

Press the Finish button. It is now possible to see from the Device Manager of your PC (see chapter 5) that the first USB driver part is successfully installed. DEIF A/S Page 9 of 18

It is now necessary to repeat the last operations for installing the driver for the virtual Com Port. The window below appears: Select the No, not this time option, and then press the Next button. Select the automatic installation (first option) and press Next. This window appears : Press the Continue anyway button for proceeding with this installation process. DEIF A/S Page 10 of 18

Press the Finish button. It is now possible to see from the Device Manager of your PC (see chapter 5) that the second USB driver part is successfully installed (driver for the virtual Com port). DEIF A/S Page 11 of 18

5. Finding the com port number of the USB converter on your computer Press Start and select Control Panel. Double click on System and select Hardware. Press Device Manager and double click on Ports (COM & LPT). DEIF A/S Page 12 of 18

As you can see in the above screen dump, the USB link is successfully installed and is called COM8 on the computer. This information will be useful for the future configuration of the utility software (see chapter Configuration of the DEIF utility software). DEIF A/S Page 13 of 18

6. Adjusting the USB communication port parameters on your computer Open the device manager window (as described on the previous page) and double click on the line CP210x USB to UART Bridge Controller (COM8). If the Device status is not This device is working properly., or if you have a problem with the device, try restarting windows. If the problem persists, do a reinstallation of the drivers or contact the DEIF support team. Otherwise, choose Port Settings and configure all like this: Afterwards, press OK and close all opened windows. The configuration of the USB converter is now finished. You now open the DEIF utility software and check the software version. Our newest version can be downloaded free of charge from the DEIF web site at: www.deif.com. DEIF A/S Page 14 of 18

7. How to change the COM port number (if required) Referring to the USB serial port (COM2) property window described on the previous page, click on the Advanced button. Select the required COM port in the COM Port Number field and press the OK button. DEIF A/S Page 15 of 18

8. Configuration of the DEIF multi-line 2 utility software When opened, choose the menu File and Settings, or select the hammer icon indicated by the mouse pointer. Choose Communication and select the same COM port as previously. If it is COM2 in your case, you then enter 2 (or use the up or down arrows) in the Communication port field. Press OK, and the above window will close. You are now ready to work on-line with the utility software connected to a multi-line 2 unit through the USB type service port and the USB COM2 port of your computer. DEIF A/S Page 16 of 18

9. How to uninstall the driver on your computer (if required) If you want to remove this application (or driver) from your computer in future, press Start and select Control Panel on your computer. Double click on the line Add or Remove Programs. Find and click on the line CP210x USB to UART Bridge Controller. Press Change/Remove. DEIF A/S Page 17 of 18

Press Yes. After a while, you will get a confirmation that the driver has been successfully uninstalled. Press OK. By refreshing the Add or Remove Programs window, you will notice that this program/driver is actually gone. For further technical data, please refer to the Designer s Reference Handbook. DEIF A/S reserves the right to change any of the above DEIF A/S Page 18 of 18