File E41515 Vol. 5 Sec. 5 Page 1 Issued: and Report Revised:

Similar documents
File E Project 00ME December 18, 2000 REPORT COMBINATION CONTROLLERS. Siemens AG Amberg, Germany

Advantages of a Full Featured 700 Series Relay

V REG.-Nr. 3919, Z E214024

File E Project 90ME March 12, 1991 REPORT

AZ420 MINIATURE GENERAL PURPOSE RELAY

Bulletin 700-HA Tube Base Relay

Solving your relay requirements since 1922

78 Series Electromechanical Relay Selection Guide

ALLEN BRADLEY RELAY Bulletin 700-HF

Micro Contactor MA Series

PERFORMANCE SPECIFICATION

PERFORMANCE SPECIFICATION SHEET

1 POLE - 10A Low Profile Type. (c) Coil type A : Standard type (530mW) D : High sensitive type (400mW - V type only)

Ultra Slim Relays 24

PERFORMANCE SPECIFICATION SHEET

PERFORMANCE SPECIFICATION SHEET

Mini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks

Ice Cube Relays. R2/R4 Plug-in Power Relays... G58 Technical Information... G63. R15 Plug-in Power Relays... G68 Technical Information...

JV SERIES 1 POLE 5 A (MEDIUM LOAD CONTROL) POWER RELAY. RoHS compliant

POWER RELAY. NY Series. 1 POLE - 5A Slim Type FTR-K1 SERIES FEATURES

KU series KUP Enclosed Relay KUIP VDE 8mm Coil to Contacts KUGP VDE 8mm 3mm Gap Coil to Contacts KUEP 10 Amp 150VDC Load Switching KUMP 15 Amp 277VAC

SIGNAL RELAY. FTR-C2 Series. 2 POLES - 2A High Isolation Wide Contact Gap FTR-K1 SERIES FEATURES

PERFORMANCE SPECIFICATION SHEET

SILENT POWER RELAY. FTR-H3 Series. 1 POLE - 78A/120A Inrush Current Type FTR-K1 SERIES NOT FOR NEW DESIGN FEATURES

Solid-state Timer H3YN

KU series KUP Enclosed Relay KUIP VDE 8mm Coil to Contacts KUGP VDE 8mm 3mm Gap Coil to Contacts KUEP 10 Amp 150VDC Load Switching KUMP 15 Amp 277VAC

C E R T I F I C A T E O F C O M P L I A N C E

Bulletin 700-HL 2-Pole Terminal Block Relay

TABLE OF CONTENTS Bulletin 700-HA General Purpose Relays and Timing Relays. Description Page Description Page. Description

MICRO SWITCH Military-Grade Toggle Switches. TL Series. Datasheet

PRODUCT SPECIFICATION. PC Board Relays. Series.

File E Project 93ME39941, Issued: November 29, 1993 New: April 26, 2006 REPORT COMPONENT - POWER SUPPLIES. For Use In

Bulletin 700-P, 700DC-P Industrial Relays

Solving your relay requirements since 1922

PACSystems* RX3i and Series IC693MDL940 / IC694MDL940

V-3000 Series Miniature Basic Switches

Z-15GW2277 Z-15GW2277-B

File E Project 01ME October 15, 2001 REPORT

Oiltight Switches & Pilot Devices

XMC0 Series. Features. Type model nomenclature - Ordering Information. Definite Purpose Contactors. Description

VZBs. Power PCB Relay RT2 2 pole 8 A, DC and AC-coil. Features. Contact data

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

POWER RELAY. FTR-MY Series. 1 POLE - 5A Slim Power Relay FTR-K1 SERIES FEATURES. APPLICATIONS PLC, I/O module inverter control

Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers

Industrial Relays, General Information

Bulletin 871D Cylinder Position Inductive Style

Ordering Information. Snap Action Switch V. Model Number Legend V General Purpose Snap Action Switch. Snap Action Switch V 121

MICRO SWITCH Military-Grade Toggle Switches TL Series Issue 4. Datasheet FEATURES POTENTIAL APPLICATIONS DESCRIPTION DIFFERENTIATION PORTFOLIO

(e) Enclosure B : Flux proof type, RTII C : Plastic sealed type (with type), RTIII K : Plastic sealed type, RTIII

Global Water Instrumentation, Inc.

Latching, Sequence and Impulse Relays Application Data

Siemens AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE AMBERG, GERMANY

C E R T I F I C A T E O F C O M P L I A N C E

Mechanical Relay Board: 8 and 4 gang

5 Fieldbus Technology

3 Series Thumbwheel Switches

1 POLE - 5A Medium Load Control

UL TEST REPORT AND PROCEDURE

Oiltight Switches & Pilot Devices

2 POLES - 2 A (Slim Profile Signal Relay)

File E Project 00SC September 27, 2000 REPORT COMPONENT - POWER SUPPLIES, MEDICAL AND DENTAL EQUIPMENT

Distinctive Characteristics

UL TEST REPORT AND PROCEDURE

File E Project 08CA March 24, 2009 REPORT. Intrinsically Safe Equipment and Systems for Use in Hazardous Locations.

File E Project 10NK September 7, 2011 REPORT PROGRAMMABLE CONTROLLERS, FOR USE IN HAZARDOUS LOCATIONS (NRAG, NRAG7)

EU Declaration of Conformity

Allen-Bradley Drives

M-Line Series MN Multi-Pin Plugs and Receptacles Vac, Vdc

RSTI-EP Slice I/O. Digital Output Module

Miniature Basic Switch

Magnetic Style Safety Interlock Switches

Conveyor Belt Alignment Switches from IDEM

APL/UPL, 205/295 Series Magnetic Circuit Protectors

Contacts Contact Arrangement. 8-Pole Relay. 12-Pole Relay

1 POLE 8 A (MEDIUM LOAD CONTROL)

RA4 SERIES. 4 POLES 1 to 2 A (FOR SIGNAL SWITCHING) MINIATURE RELAY. RoHS Compliant FEATURES ORDERING INFORMATION SAFETY STANDARD AND FILE NUMBERS

22mm Non Illuminated Metal Operators

4 C/O. Contact material AgNi AgNi gold-plated Nominal contact current Inrush current

DISCONTINUED (2009) RA4 SERIES. 4 POLES 1 to 2 A (FOR SIGNAL SWITCHING) MINIATURE RELAY. RoHS compliant. FEATURES Ultra high sensitivity

Cat. No. (Spring Clamp. Input Voltage

File E Project 05NK Issued: Revised: REPORT CLASSIFIED FOR USE WITH SPECIFIED EQUIPMENT (XUPD)

Pluggable interface relays CR-M Miniature relays

ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters (1 of 2) Lecture 6 Contactors and Motor Starters

File E Project 98ME March 9, 1998 REPORT

With operation indicators **LY2N-CR **LY2ZN-CR

File E Project 00NK September 15, 2000 REPORT TELEMETERING EQUIPMENT FOR USE IN HAZARDOUS LOCATIONS. Bristol Babcock Inc.

Transistor drive 2c/4c 5A slim power relays

Crane Control Contactors and Relays

New relay, production not started, engineering samples available. 1 POLE - 8A Reflow Solderable Relay

Relays & Sockets. RQ Series. RQ Series PCB Relays Part Number Selection

File E Project 89ME November 30, 1989 REPORT COMPONENT - POWER SUPPLY. Vicor Corp. Andover, MA

RPM42P7 power plug-in relay - Zelio RPM - 4 C/O V AC - 15 A - with LED

PowerFlex DC Drive Frame B Pulse Transformer Circuit Board

POWER RELAY. VF Series. 1 POLE - 20/25/30A - Heavy power control FTR-K1 SERIES. To be discontinued FEATURES

(e) Enclosure B : Flux proof type, RTII C : Plastic sealed type (with tape), RTIII K : Plastic sealed type, RTIII

Classification Enclosure rating Input voltage Type of

UL TEST REPORT AND PROCEDURE

C E R T I F I C A T E O F C O M P L I A N C E

CONTA-ELECTRONICS. Fuse, component, diode and indicator modules

J8 SWITCHES WITH TRIP FUNCTION UPGRADED TYPE

Transcription:

File E41515 Vol. 5 Sec. 5 Page 1 Issued: 11-29-73 and Report Revised: 8-10-01 DESCRIPTION PRODUCT COVERED: Type MY may be followed by Q, followed by 4, may be followed by H3YN or H3YW (Amendment), may be followed by Z, may be followed by F or S, may be followed by -0, -02 or -T, may be followed by E, may be followed by A, B or G may be followed by I, I2 or I4, may be followed by N, -D, N-D, N-D2, CR or N- CR, may be followed by -3 or -4, may be followed by optional letter(s) and/or number(s), may be followed by -40 or -04, -M, -L, -40L or -04L, may be followed by -AC6 through -AC240 or -DC5 through -DC125, may be followed by optional letter(s) and/or number(s). Type MY4 or MYQ4, may be followed by a blank, E or Z, followed by a blank, I or I2 or I4, may be followed by a blank, N, -D, -N-D or N-D2, CR or N-CR, followed by a blank, -40 or -04, followed by a blank or 3, followed by a blank, 0, 02, T, S, F, A or B, may be followed by optional letter(s) and/or number(s), followed by a blank, AC6 through AC240 or DC5 through DC125, may be followed by optional letter(s) and/or number(s). * Type MY with or without 4, followed by optional letters and/or numbers, followed by 00600 through 006999. * Type MY4, may be followed by Z, may be followed by I or I5, may be followed by N, may be followed by 1, may be followed by D, D2 or CR, may be followed by optional suffixes, may be followed by S. GENERAL: These devices are 4-pole double throw relays with normally open and/or normally closed contact for use in Industrial Control Equipment, UL 508, Clothes Dryers, Washing Machines, UL 560 and similar devices, Commercial Refrigerators and Freezers, UL 471, where the suitability of the combination has been determined by Underwriters Laboratories Inc. ENGINEERING CONSIDERATIONS (NOT FOR FIELD REPRESENTATIVE'S USE): Use - For use only in complete equipment where the acceptability of the combination is determined by Underwriters Laboratories Inc. This component has been judged on the basis of the required spacings in the Standard for Industrial Control Equipment, UL 508, 15th Edition, Table 48.1, Column B; Electric Home Laundry Equipment, UL 560, Par. 18.2; and Commercial Refrigerators and Freezers, UL 471, which covers the end-use product for which the component was designed.

File E41515 Vol. 5 Sec. 5 Page 1-1 Issued: 11-29-73 and Report Revised: 6-22-01 RATINGS: All Types (except MYQ4) 1/6 Hp; 125, 250 V ac (1,000 operations) 5.0 A, 28 V dc or 240 V ac general use maximum (Same polarity) 1/10 hp, 120 V ac, 5 A, 250 V ac, 30 V dc (resistive load) Maximum 7 A, 240 V ac, general use. Maximum 7 A, 24 V dc, resistive. *B300 Pilot Duty (same polarity only) MYQ4 Types with AC Barrier See nomenclature, Item 5 for US types Item 3 for UA types Maximum 5 A, 240 V ac, general use (same polarity) Maximum 5 A, 28 V dc, resistive 1/10 Hp, 120 V ac (single contact only) Same ratings as above, with additional rating of 120 V dc, -0.2 A, resistive load per pole. Type MY4, Additional Construction: Coil: 6-240 V ac, 6-125 V dc Contact: Single Contact MY4 4 poles 5 A, 250 V ac/30 V dc general 4 c purpose *B300 Pilot Duty (same polarity only) Single Contacts MY4Z 4 poles 4 c purpose Twin Contact 5 A, 250 V ac/30 V dc general

File E41515 Vol. 5 Sec. 5 Page 1A Issued: 11-29-73 and Report Revised: 5-31-01 Conditions of Acceptability - 1. The ratings of the control equipment should not exceed the ratings above. (Same polarity between all poles when used in Industrial Control Equipment and opposite polarity between poles when used in Electric Home Laundry Equipment where potential involved is not more than 120 V.) 2. The device should be mounted in enclosures having adequate strength and thickness in the intended manner and with acceptable spacings being provided throughout. 3. When the device is mounted in enclosures, the test record should be reviewed to determine if tests need be repeated. 4. Plug-in type devices should be supplied with the mounting base with suitable marking to identify the terminals as marked on the side of the cover. 5. The solder tab terminals (when wired) should be examined for spacings and security. 6. The spacings between the frame and the coil circuit and/or the contact circuit do not meet the spacings requirements and as such, the frame should be considered a live part. 7. Spacings are suitable for use for opposite polarity for elevator and escalator controls for 150 V or less. per Table 14 of ASME-A 17.5 dated 1996. * 8. The relay MYQ4 complies with the Sealed Device requirements of UL 2279, and Para. 21 of IEC 60079-15 for Class I, Div. 2, Groups A, B, C, D Hazardous Locations. This is based on use of the sealant described in Fig. 2, Item 2. In end use, consideration should be given to relay enclosure temperature and to mechanical securement of relay to terminal block. Ratings are limited to 3 A, 240 V. DIMENSIONS: All dimensions given in the detailed description are nominal unless otherwise indicated. Note - Please see Table 1 on Page 3A for specific parts provided with relays.

File E41515 Vol. 5 Sec. 5 Page 2 Issued: 11-29-73 and Report Revised: 9-26-96 NOMENCLATURE: Type with Suffix -US. MY Q 4 H3YN Z F -0 E A 12 N -3 QSK1-40 -DC24 - or/and QSK2 I II III IV V VI VII VIII IX X XI XII XIII IXV XV XVI I - Basic type designation. II - Basic construction. Blank - Standard relay. Q - Plastic sealed relay. III - Number of poles. IV - Construction 4-4-poles. Blank - Provided with cover. H3YN - Provided without cover (Marking on each package only) *H3YW - Same as H3YN except welded terminals. V - Contact construction. Blank - Single contact. Z - Twin contact. VI - Cover configuration. Blank - Standard type, without mounting bracket. F - Upper mounting bracket style. S - Lower mounting bracket style. VII - Terminal construction. Blank - Solder type terminal. -0 - Printed circuit terminal. -02 - Printed circuit terminal. -T - Tab terminal. VIII - Contact material. Blank - Silver, with or without gold plated. E - Silver cadmium oxide, with or without gold plated. (Table Cont'd)

File E41515 Vol. 5 Sec. 5 Page 2A Issued: 11-29-73 and Report Revised: 2-10-97 IX - Optional construction Blank - Standard relay, without mounting screw A - Upper mounting screw type B - Side mounting screw type * G - Bottom side screw type (ground terminal type) X - Test button Blank - Standard type, without test button I - Upper mounting test button I2 - Front mounting test button I4 - Front mounting test button (AC specification; Orange) (DC specification; Blue) XI - Construction Blank - Standard type, without coil lamp N - Provided with neon lamp type -D - Provided with diode type N-D - Provided with neon lamp diode type N-D2 - Provided with neon lamp diode type CR - Provided with spark killer N-CR - Provided with neon lamp spark killer XII - Barrier construction Blank - With or without arc barrier -3 or -4 - With arc barrier XIII - Optional Suffix(es) - Does not affect construction. May include optional letter(s) and/or number(s) for safety standard(s). IXV - Additional suffix Blank - Normally open contact and normally closed contact -40 - Normally open contact only -04 - Normally closed contact only -M - Marking before breaking contact -L - Revised construction -40L - Revised construction -04L - Revised construction XV - Coil voltage Blank - Marked on cover or coil surface -AC6 through -AC240 - Any voltage within range -DC5 through -DC125 - Any voltage within range XVI - Optional suffixes May be followed by additional letter(s) and/or number(s) for sales purposes.

File E41515 Vol. 5 Sec. 5 Page 2B Issued: 11-29-73 and Report Revised: 8-27-96 NOMENCLATURE: Type with UA in type number. * MY4 E I N-D -40-3 -02 QSK1 -AC6 -or/and QSK2 I II III IV V VI VII VIII IX X I - Basic type designation. MY4 - Basic type. MYQ4 - Sealed type. II - Contact material and construction. Blank - Silver with or without gold plated, single contact. E - Silver cadmium oxide with or without gold plated, single contact. Z - Silver with or without gold plate, bifurcated contact. III - Test button. Blank - Without test button. I - Upper mounting test button. I2 - Front mounting test button. I4 - Front mounting test button (AC specification; Orange) (DC specification; Blue) IV - Construction. Blank - Not provided with coil lamp. N - Provided with neon lamp. -D - Provided with diode. N-D - Provided wtih neon lamp diode. N-D2 - Provided with neon lamp diode. CR - Provided with spark killer. N-CR - Provided with neon lamp spark killer. V - Additional suffix. Blank - N.O. and N.C. contacts. -40 - N.O. contact only. -04 - N.C. contact only. VI - Barrier construction. Blank - With or without arc barrier. -3 - With arc barrier.

File E41515 Vol. 5 Sec. 5 Page 2B1 Issued: 11-29-73 and Report Revised: 8-27-96 VII - Terminal and cover figure. Blank - Solder type terminal. -0 - Printed circuit terminal. -02 - Printed circuit terminal. -T1 - Tab terminal. S - Mounting tab at lower position. F - Mounting tab at upper position. A - Upper mounting style. B - Side mounting style. * VIII - Optional Suffix(es) - Does not affect construction. May include optional letter(s) and/or number(s) for safety standard(s). IX - Coil voltage. -AC6 through 240 (any voltage within range) -DC5 through 125 Blank - Marked on cover or coil surface. X - Optional suffixes. May be followed by additional letter(s) and/or number(s) for sales purposes.

File E41515 Vol. 5 Sec. 5 Page 2B2 Issued: 11-29-73 and Report Revised: 9-27-01 TYPE MY4, ADDITIONAL CONSTRUCTION: MY 4 Z I N 1 - D - QSK1 - QSK2 (S) I II III IV V VI VII VIII IX X I. Basic Type Designation II. Contact Form 4: 4PDT III. Contact Type Blank: Single Z: Bifurcated IV. Test Button Blank: None I: Provided with Test Button * I5: Provided with Test Button without mechanical indicator V. LED Indicator Blank: None N: Provide with LED Indicator VI. Coil Polarity Blank: Standard 1: Reverse VII. Classification Blank: General-purpose D: Provided with Diode (DC Coil Only) D2: Provided with Diode (LED Indicator and DC Coil Only) CR: Provided with Spark Killer (AC Coil Only) VIII. Optional Suffixes May include optional letters and/or numbers for safety standards. IX. Optional Suffixes May include optional letters and/or numbers for sales purpose. X. Mechanical Indicator and Label Blank: None (S): Provided with Mechanical Indicator and Label

File E41515 Vol. 5 Sec. 5 *Page 2C Issued: 11-29-73 and Report Revised: 1-2-86 REPLACES PAGE 2C

File E41515 Vol. 5 Sec. 5 Page 3 Issued: 11-29-73 and Report Revised: 10-25-91 *SPACINGS: UL 560 UL 508 Spacing0-125 V 126-250 V 51-300 V Between uninsu- Through 1.6 mm 2.4 mm 1.6 mm lated current- Air carrying parts of opposite polarity and between uninsu- Over 1.6 mm 2.4 mm 3.2 mm lated current- Surface carrying parts and grounded metal parts. The frame is to be considered an intermediate part between the coil circuit and the contact circuit in which the sum of the spacings between the frame and coil circuit and between the frame and contact circuit meets the spacing requirements. MARKING: *See Sec. Gen. Marked on top or side of dust cover. Factory identification on side of dust cover or on iron core frame. Provided with coil voltage rating when not part of the nomenclature. Note: All ratings do not have to be marked on a device. Also a lower rating may be used, for example a 5 A rated device could be marked 3 A.

File E41515 Vol. 5 Sec. 5 *Page 3A Issued: 11-29-73 and Report New: 10-8-92 TABLE 1 (CONSTRUCTION TABLE) Printed Coil Neon Holder Wiring Type Ratings LED Lamp Block Board Resistance Remarks MY4N AC 6 to 240 V 0 0 None MY4N DC 6 to 120 V 0 0 270 ohm MY4N-D DC 6 to 99 V 0 0 1.2K ohm to 16K ohm MY4N-D DC 100 to 0 0 330K ohm to 125 V 430K ohm MY4N-D2 DC 6 to 125 V 0 0 270 ohm MY4N-CR AC 6 to 99 V 0 0 1.2K ohm to 15K ohm MY4N-CR AC 100 to 0 0 150K ohm to 240 V 430K ohm Note: Each provided part shows "0" mark or resistance value.

File E41515 Vol. 5 Sec. 5 Page 4 Issued: 11-29-73 and Report Revised: 1-16-98 CONSTRUCTION DETAILS: Remainder of document intentionally left blank.