INSTALLATION INSTRUCTIONS. ACB-100 Audio Control Board. This document describes the installation procedure for the ACB-100 Audio Control Board.

Similar documents
INSTALLATION INSTRUCTIONS. This document describes the installation procedure for the SAB-400 and SAB-401 Station Audio Board.

INSTALLATION INSTRUCTIONS. This document describes the installation procedures for the TMM-441 Touchscreen Master Module.

INSTALLATION INSTRUCTIONS. FST-420 Fiber Station Transceiver

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS. DCC and DCE Installation Instructions. Table of Contents

INSTALLATION INSTRUCTIONS

DXI Quick Troubleshooting Guide

INDUSTRIAL POE SWITCH

FVT/FVR20D2I1C4E INSTALLATION AND OPERATION MANUAL

ICM-400 Series Intercom Stations

9/27/04 cci Cablecom Inc. 1

4.7 Expansion Module MAC00-FS1/FS4

Installing the DX LCD Display

ZDL-V200. Refer to Steps: 1 Thru. 4 Please Follow Wiring Steps Carefully.

Connecting a Cisco Reader Module

Remote Bus Extender Slave Module

Open Desktop WorkStation System Components Items Labeled in RED are ESD Sensitive

4.8 Expansion Module MAC00-FS1/FS4

CFO100 Series. User Manual CRT141 & CRR141. CFO141 User Manual, , rev001

P/N Operation & Installation Manual Serial Control Transfer Switch Model TM-STS

Cisco ONS CL Shelf Assembly Hardware

- ELV OVERVIEW. InstallationGuide SUPPLIED PARTS RELATED PARTS. Brackets Fixtures. Other. 1 of 9 IG-STR9-ELV

BLU- CIF Interface Board

508 SERIES MICROPHONE STATIONS

Installation and Setup. In This Chapter... Installing the H0 PSCM The Profibus Network Configuring the Module

SoundwebTM. Installation Guide

Fiber optic converter audio and CAN TA OPERATION MANUAL

721EX Access Controller Installation

4100/4120-Series Class A / Class B Zone Modules Installation Instructions

RS-232 Industrial Media Converter

FSM-510G Series Ethernet Management Switch Quick Start Guide

INSTALLATION INSTRUCTIONS. Table of Contents

HygroClip DI Digital Interface for HygroClip Probes v 1.0 Instruction Manual

Automation Interface Requirements for System I/O Interface of a DPC I Welding System

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

ICPDAS FSM-510G Series Ethernet Management Switch Quick Start

7I44 MANUAL 8 CHANNEL RS-422 INTERFACE

INSTALLATION INSTRUCTIONS MODEL MRC44KP MRC44 KEYPAD

GSV-1A4 M12/2 M12/2. Highlights

Single Channel Video Insert Unit with Bi-directional Data Channel for a Dual Redundant fibre ring

Manual Documentation Number EIR418-2SFP-T 0912m

FVT/FVR10D1E(M,S)[M] 10-BIT DIGITALLY ENCODED VIDEO TRANSMITTER WITH 1 BI-DIRECTIONAL DATA CHANNEL AND 10/100MB ETHERNET

Fast Ethernet Converter. User Guide MICROSENS

Quick Installation Guide

Power connections 3) Power from 2024 to Control box (The valve harness connected) Ground (0V) +24 V. The voltage between pins 1 & 2 in JPT# 123

Digital Keypad Introduction

Instructions for the Ethernet - Product Operated Network Interface used with Ethernet Networks I.L

Kramer Electronics, Ltd. USER MANUAL. Models: 621T, DVI Optical Transmitter 621R, DVI Optical Receiver

Cabling Infrastructure

BLU- CIF Interface Board

[PDF] TYPES OF RIBBON CABLES

Saab TransponderTech. INSTALLATION GUIDE J4N Junction Box for R4 Navigation System

Operating Bulletin. Model BB3-232 and BB3-I-232 USB Multi-Drop Box. The Fastest Flow Controller Company in the World!

ACCESS/A TM AUDIO CONTROL SYSTEM MODEL: A740

Installation Instructions Model SNC Serial Network Card for USB Application with Windows

SoundwebTM. Installation Guide

8 Channel Video Transmit Unit with 9 Bi-directional Data and Audio Channels and Ethernet for a Multimode Fibre Link

BLU- CIF2 Interface Board

Product Overview CHAPTER

Metra NET Network Installation Manual

Metropolis ADM MultiService Mux Compact Shelf

ZEUS Series: microzeus with Flying Bus Boards

RS-232 Connector Pin Assignments

Power & Communication Cables

4 Connection and interface

CDI-S200 SERIAL INTERFACE CARD

APS SCALE SERIES DIMENSIONS

Accessories IC690ACC900

RS-232 Fiber Link Card System

Total Reach ISDN/DDS Isolation Card P30101

HD DIGITAL VIDEO A/B SWITCH INSTALLATION MANUAL

Meridian 1 Fiber Remote Multi-IPE Interface Description, installation, and maintenance

Redundant System Redundant System P9-1-1

8~14-Port Managed Ethernet Switch

Physical Specification Vending Machine Card Reader Module Model: CRM-170-xx

ME930C-RJ11 MAIN MODULE (FRONT CARD) MAIN MODULE. Line: RJ-11 INTERFACE MODULE (REAR CARD) Serial: DB25 CONN. SW1 RJ-11 CONN.

Plug & Play Universal Low-Loss Systems A LANscape Pretium Solutions Product

PROFESSIONAL AUDIO AND MEDIA APPLICATIONS

LNP-0602 series. 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx. User Manual

Modular Room Control (MRC) Series Expansion Board

BLU- CIF2 Interface Board

Connecting a Cisco Output Module

Loop-O 9300 Fiber Optical Mux

Data Isolation Cards. ADSL High Voltage Isolation Card. Single Line Voice Isolation Card With CID, CW & MWI. Floated 130VDC or 120VAC Input P30121

Luxline driver. LL-PCB-LUXlinedriver. Lux Lumen bvba Kernenergiestr. 53a 2610 Wilrijk. Luxline driver - page 1 T F

RING LIGHT. LED Strobe Indicator ON = Light Active Green Indicator LED

Hardware User s Manual. Digital Video Motion Detector DVMD1-X

PCS PATCH CORD SOLUTIONS PATCH CORD SOLUTIONS

F271XA Fiber-Optic Telephone Modem Technical Manual

VMI. Technical Documentation. 600 Industrial Drive, New Bern, N.C (tel / fax /

07. har-link Interface Connectors

10/100 AUTO-SENSING MEDIA CONVERTERS

Miniature Asynchronous Modems

HDMI over IP Extender HP100FT HDMI KVM, USB, RS232, IR over IP - Transmitter HP100FR HDMI KVM, USB, RS232, IR over IP Receiver

Breakout Box Hardware Manual

Avtec, Inc. Lighting Systems

Hello Angles... A First Use Guide to the VS Product Series: RS232 Interface with LD Standard Communication Protocol & Analogue 4-20mA Output Signals.

SPOS (Station Point of Sale) 200. SFTP (Station Fare Transaction Processor) 35. CQD (Card Query Device) 35. HCR (Handheld Card Reader) Cradles 120

7I74 MANUAL 8 CHANNEL RS-422 INTERFACE

07. har-link INTERFACE CONNECTORS

Transcription:

INSTALLATION INSTRUCTIONS MicroComm DXI -00 Audio Control Board. Intent & Scope This document describes the installation procedure for the -00 Audio Control Board. 2. Description The -00 Audio Control Board controls all the I/O cards in a MicroComm DXI card cage. It controls the system s audio switching and includes the system s digital signal processors. Audio trunking between card cages, which may be linked to form larger exchanges, is also made through the. Each audio control board may include up to two Digital Signal Processors (DSP) expansion modules. Each expansion module provides two more DSPs. These DSPs are used to support additional I/O cards and special functions such as Audio Level Alarms and conference calls. Digital audio trunk (CEPT) interfaces are available for fiber optic and copper conductor networks An Audio Control Board (-00) must be located in the first card slot of each card cage. -00 Document IM--00-2.5 997 Harding Instruments - Printed in Canada

8 5 5 9 9 7 50 33 8 34-00 Audio Control Board DSP s Two versions of the printed circuit board used in the -00 have been produced. The latest printed circuit board is designated as PC06487-02, while the earlier version was designated as PC06487-0 or PC06487. The main difference between the two boards is the location of the headers on the printed circuit board and the label names assigned to the headers. In the following description the labels associated with the -0 version of the printed circuit board are given in brackets. The -00 has one factory installed DSP, and headers for inserting two DSP daughter cards. Each daughter card contains two DSPs. The factory installed DSP is labeled DSP #. The daughter card inserted in header CN20 (CN) contains DSPs labeled DSP and DSP, while the daughter card inserted in header CN2 (CN2) contains DSPs labeled DSP #4 and DSP #5. The following diagrams show the location and # pin of the headers CN20 (CN) and CN2 (CN2). If a daughter card is not installed in CN20 (CN) and/or CN2 (CN2) headers four shorting jumpers must be installed in positions -2, 3-4, 5-6 and 7-8 at the right hand end of the DSP daughter card header. # 56 56 PC-046487-0 PC-046487-0 DSP DSP CN CN2 CEPT CN4 Audio/ CEPT LINK 8 CEPT R T R T CEPT2 LINK 00 Header Location for DSP s on PC06487-0 Page 2 Document IM--00-2.5

8 5 5 9 9 7 50 33 8 34-00 Audio Control Board # PC-046487-02 CN8 CEPT R T R 56 CN20 Audio/ CEPT T CEPT2 DSP CEPT LINK 8 LINK 56 CN2 PC-046487-02 DSP 00 Header Location for DSP s on PC06487-02 The card cage has 7 card slots. The card is always installed in position, while the remaining 6 slots can be used for any other type of DXI card. Determining card positions should be partially based on the intensity of the workload placed on the DSP s. The card cage slots are divided into five groups, as shown in the following diagram: Document IM--00-2.5 Page 3

-00 Audio Control Board Slot Position 3 5 7 9 3 5 7 2 4 6 8 0 2 4 6 C 8-0 C 4-6C C 2-7 C -3 7 Cage Slot Positions The groups are labeled as follows C 2-7, C 8-0, C -3, C 4-6, and C 7. The notation C 2-7, for example, represents the group of cards in slot positions 2 to 7. The various DSP workloads are distributed according to the following table: Configuration C 2-7 C 8-0 C -3 C 4-6 C 7 No daughter card DSP # DSP # DSP # DSP # DSP # card DSPs & DSP # DSP DSP DSP DSP card DSPs #4 & #5 DSP # DSP # DSP #4 DSP # DSP #5 Both s DSP # DSP DSP #4 DSP DSP #5 Note: If a system is set up for conference calls, then DSP #5 will be running the conference functions and cannot perform normal operations. Therefore you should not install an audio card with switch inputs ( or AIO cards for example) in card cage slot 7. s such as a PAB, TSB, or DIO cards can be inserted in card slot 7 since these cards do not depend on the DSP for support. Each DSP is capable of supporting 4 master stations. The slot position of the cards in the card cage and the assignment of channels to master stations must be made so as to satisfy this constraint. 4. Cage Linking The MicroComm DXI I/O card cages can be linked together to form a larger exchange. When card cages are mounted in the same equipment rack, the link connection is via the DB-5 Link connector on the rear of the. CEPT trunks are available in fiber optic and cable versions. 4. Link Cable Interface If there are two to three card cages in one equipment room, and they are mounted adjacent to each other in the equipment racks (3 ft total from to ), then the s can be connected through a back plane link cable for an inexpensive audio trunk link. One of these s must act as the controlling (the master ), Page 4 Document IM--00-2.5

# # # 00 0 # # # +2Vdc -2Vdc # # 00 # # # 00 0 # # # +2Vdc -2Vdc # # 00 # # # 00 0 # # # +2Vdc -2Vdc # # 00 AIB AIB AIB AOB AOB AOB AIO AIO AIO # # TSB # # TSB # # TSB RDB 00 RDB 00 RDB 00 # # TAB MicroComm DXI PSU-30 Power Supply # # TAB MicroComm DXI PSU-30 Power Supply # # TAB MicroComm DXI PSU-30 Power Supply PAB PAB PAB -00 Audio Control Board while the others will act as slave s. With the -00 this is achieved by removing jumpers on the printed circuit board (PCB) of the for each of the slave s [i.e. remove the jumpers on connector CN8 (CN4).]. The link between the cards is made through a special DB-5 connector located on the back of the. A ribbon link cable connects to each of the s using this connector. The ribbon link cable is supplied in two configurations; CBL-220 is used to connect two Cages together, while the CBL-230 is used to connect three Cages together (these part numbers are for -00 cards). The figure on the right shows the link connection between three Cages in the same rack. One limitation of a back plane link is that only up to three card cages can be linked in this fashion, and they must be adjacent to each other to comply with the length requirements. A back plane link has another limitation if the master in the link fails, the slave s will be unable to function. If the system specifications require fail-safe operation, then a CEPT loop or redundant cards (with a redundant back plane link) should be used. DIO 300 DIO 300 Slave Link Cable DIO 300 Slave The MicroComm DXI I/O card cages can be linked together to form a larger exchange. When card cages are mounted in the same equipment rack, the link connection is via the DB-5 Link connector on the rear of the card. To interconnect multiple card cages at remote locations to form an exchange, CEPT ports on the are used. CEPT trunks are available in fiber optic and copper cable versions. 4.2 CEPT Trunk Configuration The network configuration of the CEPT trunk is that of a bi-directional loop, as indicated in the diagram below. Each transmit and receive port of a CEPT pair is connected to the opposite ports of the next in the loop i.e. Tx of the first is connected to Rx2 of the next, while Tx2 of the second is connected to Rx of the first. In the CEPT network show the s are connected so that the Primary loop is in the clockwise direction, while the Secondary loop is in a counterclockwise direction. With this configuration if one link is broken then data can still be transmitted from one to any other by switching to the Secondary loop. -00-00 -00 Rx2 Tx Rx2 Tx Rx2 Tx Tx2 Rx Tx2 Rx Tx2 Rx Secondary Loop Primary Loop CEPT Network Document IM--00-2.5 Page 5

-00 Audio Control Board 4.3 Copper CEPT Network Interface For the copper conductor interface version of the CEPT trunk a CBL-0-A cable connects to the female DB-50 connector on the rear of the card. The CBL-0 cable has three individual multi-conductor cables; (i) four (4) shielded twisted pair, (ii) six (6) unshielded twisted pairs, and (iii) four (4) unshielded twisted pairs with a cable shield. Only one of the cables (four unshielded twisted pair with cable shield) is used with the card. The pin outs for a mating male connector on a CBL-0 cable is shown in the following wiring table. Only the Tx and Rx CEPT connections are used for this application. Signals indicated are from the board s perspective. The maximum distance between cards for a 22 gauge (unshielded) twisted pair is 8,200 ft (2.5 km). 4.4 Fiber Optic CEPT Network Interface The fiber optic CEPT interface version of the audio control board is provided with four ST type fiber optic connectors. These are marked for each of CEPT and CEPT 2 as Tx (Transmit) and Rx (Receive) from the board s perspective. The maximum signal strength power loss in a fiber optics CEPT link must not exceed 2 db. The length of cable, number of connectors, and number of patch panels determines the loss of signal strength in fiber optic cables. With only one pair of connectors between cards for a 62.5/25 multimode fiber optic cable the maximum distance between s is 8,500 ft (2.6 km). Typically, every connector reduces the signal by 0.3 db, and every 3,300 ft ( km) of cable reduces the signal by 3.2 db, assuming a perfect connection. You should allow for some extra margin for field-grade connections. Page 6 Document IM--00-2.5

Wiring Table DB-50 Pin Number -00 Audio Control Board Signal Name Wire Color Cable Wire Color Cable 2 Wire Color Cable 3 Audio + Black 8 Audio - Red 2 34 Audio Shield BR Shield 3 2 Input White-Blue 4 9 Common Blue-White 5 35 Output White-Orange 6 3 Audio 2 + Black 7 20 Audio 2 - White 8 36 Audio 2 Shield BW Shield 9 4 Input 2 Orange-White 0 2 Common 2 White-Green 37 Output 2 Green-White 2 5 Audio 3 + Black 3 22 Audio 3 - Green 4 38 Audio 3 Shield BG Shield 5 6 Input 3 White-Brown 6 23 Common 3 Brown-White 7 39 Output 3 White-Grey 8 7 Audio 4 + Black 9 24 Audio 4 - Blue 20 40 Audio 4 Shield BBl Shield 2 8 Input 4 Grey-White 22 25 Common 4 Red-Blue 23 4 Output 4 Blue-Red 24 9 N/C 25 26 N/C 26 42 N/C 27 0 N/C 28 27 N/C 29 43 N/C 30 N/C 3 28 N/C 32 44 N/C 33 2 N/C 34 29 N/C 35 45 N/C 36 3 N/C 37 30 N/C 38 46 N/C 39 4 N/C 40 3 N/C 4 47 Rx 2 + White-Blue 42 5 Rx 2 - Blue 43 32 Tx 2 - White-Orange 44 48 Tx 2 + Orange 45 6 Gnd Cable Shield 46 33 Rx + White-Green 47 49 Rx - Green 48 7 Tx - Brown 49 50 Tx + White-Brown 50 Terminal Block Pin Number Document IM--00-2.5 Page 7

-00 Audio Control Board 5. System Planning Worksheet The table on the following page may be copied and used as a worksheet for planning system wiring. It shows the audio control board s pin numbers, pin signal name, associated CBL-0 cable wire colors, and terminal block terminal numbers. The blank column is to be used to identify the field wiring interface connection. Page 8 Document IM--00-2.5

-00 Audio Control Board Cage: DB-50 Pin Number Signal Name Wire Color Cable Wire Color Cable 2 Wire Color Cable 3 Terminal Block Pin Number Audio + Black 8 Audio - Red 2 34 Audio Shield BR Shield 3 2 Input White-Blue 4 9 Common Blue-White 5 35 Output White-Orange 6 3 Audio 2 + Black 7 20 Audio 2 - White 8 36 Audio 2 Shield BW Shield 9 4 Input 2 Orange-White 0 2 Common 2 White-Green 37 Output 2 Green-White 2 5 Audio 3 + Black 3 22 Audio 3 - Green 4 38 Audio 3 Shield BG Shield 5 6 Input 3 White-Brown 6 23 Common 3 Brown-White 7 39 Output 3 White-Grey 8 7 Audio 4 + Black 9 24 Audio 4 - Blue 20 40 Audio 4 Shield BBl Shield 2 8 Input 4 Grey-White 22 25 Common 4 Red-Blue 23 4 Output 4 Blue-Red 24 9 N/C 25 26 N/C 26 42 N/C 27 0 N/C 28 27 N/C 29 43 N/C 30 N/C 3 28 N/C 32 44 N/C 33 2 N/C 34 29 N/C 35 45 N/C 36 3 N/C 37 30 N/C 38 46 N/C 39 4 N/C 40 3 N/C 4 47 Rx 2 + White-Blue 42 5 Rx 2 - Blue 43 32 Tx 2 - White-Orange 44 48 Tx 2 + Orange 45 6 Gnd Cable Shield 46 33 Rx + White-Green 47 49 Rx - Green 48 7 Tx - Brown 49 50 Tx + White-Brown 50 Slot: To Document IM--00-2.5 Page 9