CLAMP-ON Graphic Power Quality Analyzer. Software Users Manual v3.4

Similar documents
Power & Harmonics Analyzer

3 PHASE POWER ANALYZER

Three-Phase Power Quality Analyzer PowerPad Model 3945-B

Three-Phase Power Quality Analyzer PowerPad Model 3945

PowerView for the EnergyPro

Enerscope-3S Studio. User Manual. Windows Software for Consulting and Analysing Data collected by Enerscope-3S Power Analyzer.

THREE-PHASE POWER QUALITY ANALYZER

DL150 Software Instructions

NanoWin. User's Manual - Rel. NW-1.1. Windows 9x and Windows NT 4.0 Data Management Software for NANOVIP Plus and NANOVIP Plus MEM Handheld Analysers

User Guide. 3-Phase Power and Harmonics Analyzer / Datalogger MODEL PQ3470

Spectrometer Visible Light Spectrometer V4.4

power quality Models 8230 & 8220

Digital Storage Oscilloscope

DL160 Datalogger Software Guide

True RMS AC Voltage/Current Datalogger

Model POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter

Smart Data Link with KM Switch. User Manual MD-KM-PIP

LadibugTM Visual Presenter Image Software User Manual

Quick Start Guide. v1.1. Copyright 2011 AVID Technologies, Inc. Twinsburg, Ohio USA All Rights Reserved

PowerPad III Model 8336

Digital Multifunction Meters. Digital Multifunction Meters

PowerPad III Model 8435

Three-Phase Power Quality Analyzer PowerPad Model 3945

BFM-II BFM-II BRANCH FEEDER MONITOR. Highlights

3 PHASE POWER ANALYZER

Table of Contents. 1 Read This First 1. Instructions for Use Software Requirements Description of Additional Functions

DIN Rail Smart Meter for Single and Three Phase Electrical Systems

NEW. DM-4 Power Quality Recorder. Rugged Remote User Interface with Memory TRUE

Plug the USB interface of KAMKBMXBRNA gaming keyboard onto the free USB port of the computer. The

PowerPad. Three-Phase Power Quality Analyzer. Power Quality Analysis Made Easy! Model 8335

for Windows Version 2.xxx User Manual Rev. 2.0 Manual EM-LAB V2.0 1 of 41

Multifunction Transducer MT440

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

USER MANUAL 2012 V1.1

PQ ANALYZER PROCUREMENT SAMPLE SPECIFICATION

USB 2.0 All-in-One Cable

USB Temperature and Humidity Data Logger Instruction Manual

Instructions for Use

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # Series Power Analyzer Model 806 Instruction Manual

NP40 - PORTABLE POWER QUALITY ANALYZER FEATURES

SDM630M CT USER MANUAL 2016 V4.7. DIN Rail Energy Meter for Single and Three Phase Electrical Systems

U-20 Data Collection Software (U-20 for Win-XP/E) Operation Manual

NEW! NP40 - PORTABLE POWER QUALITY ANALYZER FEATURES

B-Works 2 User s Guide

Quick Start Guide Agilent Technologies 14565A Device Characterization Software for Windows 98, Windows NT 4.0, Windows 2000 and Windows XP

GUI MANAGER USER GUIDE

Guide to using Multi-Flo and Med-eBase Remote control

Smart KM Link User Manual

Devices currently supported are: Fluke 43x-I V02.10 Fluke 1735 V01.10 Fluke VR 1710 V1.31

Ranger PM6000. Power Quality Monitor

mscope Low Cost, High Performance Automotive Scope

RGM180 Display Series

USB Keyboard and Mouse Console Switch User Manual

EM300 Series. ET300 Series

PQM - Power Quality Monitoring

C-322. Model. Instruction Manual. Datalogging Sound Level Meter. reedinstruments. www. com. Tripod sold separately (Model BS-6)

3 Phase Power Analyser / Data Logger

1000A 3-Phase Power Analyzer/Datalogger

Fluke 43B. Power Quality Analyzer. Getting Started. EN June Fluke Corporation, All rights reserved. Printed in The Netherlands.

Alpha-Numeric Display Pager MODEL :AL-A28. Gold Apollo Co., Ltd.

MI 2792A PowerQ4 Plus

User's Guide. Model (60Hz) Model (50Hz) 1000A 3-Phase Power Analyzer/Datalogger NO.

3-Phase Power Analyzer/Datalogger

OPERATION MANUAL. MV-410HS Layout Editor. Version higher. Command

MPQ2000. Portable Power Quality Analyzer. IEC Class A compliance. Powered off of phase A voltage ac/dc Vac and 1000 Vdc range

Instruction Manual HIOKI Standby Power Measurement Software

NEMO HD MULTI-FUNC METER BASE (MF96001)

TROVIS-VIEW 4 Software TROVIS Operating Instructions EB 6661 EN. Electronics from SAMSON

PITE 3561 Power Quality Analyzer User Manual

1200A 3-Phase Power Analyzer/Datalogger

CVI SPECTRAL PRODUCTS. 111 Highland Drive Putnam CT, (860) SM32Pro

UMG 605. UMG 605 power quality analyzer (EN 50160, IEEE 519, ITIC)

B+G E-Tech User Manual for SDM630 SDM630. Din Rail Smart Energy Meter for Single and Three Phase Electrical Systems USER MANUAL 2013 V1.

Manual for MantraJet 1100 CD/DVD auto-printer

ALARM-CLOCK / RADIO DIGITAL PHOTO FRAME

Quick Start for MK30XEMETER Project name: MQX-Based Kinetis (MK30X256) Single-Phase Electricity Meter Reference Design

Release Notes. R&S ES-SCAN EMI Measurement Software

Contents Introduction..2 System Requirements 2 Package Contents..3 PC Camera Introduction 3 Set up PC Camera.4 Software Installation Arcsoft

DCRJ8 DCRJ12 Automatic power factor regulator

How to install or remove the ISaGRAF development platform properly

Power Energy Analyser & Logic Controller Maximum Demand Load Shed Controller 2nd - 40th Voltage & Current Harmonic Analyser

FU2200B FU2200B V Ethernet Power Meter with Data Logger. Features. Applications

WARNING: Do not use the thermometer/data logger before you read the users manual and the following instructions.

TouchKit TouchScreen Controller User Guide for Windows 2000 / XP Version: 3.2.4

Power analyzer CVM-B100 CVM-B150 INSTRUCTION MANUAL (M010B A) MEASURING EQUIPMENT

EXPRESS. Users Guide. Version 3.5

USB Serial Converter

EM6400 series Multi-Function meters

for demos & updates

USER MANUAL S6000 / S7000 S8000 / S9000. Associated Research, Inc., West Laurel Drive Lake Forest, Illinois, U.S.A.

WiRobot TM DRK6000 QUICK START

CVM-B100 CVM-B150 INSTRUCTION MANUAL (M010B B)

Short form Manual ANALYST3Q and WinA3Q

Power Vision 1.5 (Cod )

Voltage Transducer UMT516 / MT516

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

ENERGY MASTER. Rev. 1.2 Date: 02/09/10

1.3 MegaPixel Auto Focus Webcam USER MANUAL

Copyright Autodesk, Inc.

IMC Intelligent Analysis Report v7.1 (E0301P02) Copyright (c) 2015 Hewlett-Packard Development Company, L.P. and its licensors.

Transcription:

CLAMP-ON Graphic Power Quality Analyzer Software Users Manual v3.4

Table of Contents 1. Introduction...1-1 1.1 Operating Environment...1-1 1.2 Hardware...1-1 1.3 Connecting Procedures...1-1 2. Software Installation...2-1 2.1 Install Application Program...2-1 2.2 Install USB Driver...2-2 3. Software Operation...3-1 3.1 Start Executing Program...3-1 3.2 Functions of Main Screen...3-2 3.3 Setting Parameters...3-3 3.4 Communication...3-5 3.5 Down Load Data...3-6 3.6 Clear Memory...3-7 4. Communication...4-1 4.1 Communication Screen I...4-1 4.2 Communication Screen II...4-2 4.3 Communication Screen III...4-3 4.4 Communication Screen IV...4-4 4.5 Open / Save Data...4-5 4.6 Setting MD Time & Sample Rate...4-5 4.7 Choosing Printer...4-7 4.8 Waveform...4-7 4.9 Waveform Redrawing...4-8 I

Table of Contents 4.10 Printing Waveform...4-8 4.11 Operation Modes...4-9 4.12 Mode Resetting...4-10 II

Introduction 1. Introduction 1.1 Operating Environment * Application program should be installed in the operation system of Microsoft Windows Vista / XP / 2000 (SP3). * NI-VISA Runtime Engine should be installed (Application program will install it automatically). * USB driver program should be installed (refer to chapter 2.2). 1.2 Hardware * Personal Computer (PC): we recommend the processor of Pentium III Celeron 600MHz or above. * RAM: min. 256MB, but we recommend 512MB of RAM or more. * Screen resolution: requires 1,024 x 768 pixels. * CLAMP-ON Graphic Power Quality Analyzer. * USB cable. 1.3 Connecting Procedures Step 1: Turn on PC and CLAMP-ON Graphic Power Quality Analyzer. Step 2: Connect RS-232 to USB Cable. Step 3: Start Application Program of CLAMP-ON Graphic Power Quality Analyzer. Step 4: Select correct Serial Port Number. 1-1

Software Installation 2. Software Installation 2.1 Install Application Program Execute setup.exe (which is in installation disc) to enter the procedures of installing Application Program. Please follow the instructions to install Application Program. 1. After putting the installation disc into CD-ROM drive, the application program will automatically execute the installation. 2. If the installation is not automatically executed, please choose the setup.exe program in the installation disc to perform the installation. 3. After Application Program has been installed, please Restart the PC. 2-1

Software Installation 2.2 Install USB Driver Choose USB Driver Directory in the installation disc, click CP210x_VCP_Win2K_XP_S2K3.exe program (for Windows Vista / XP / 2000) to execute the installation of USB Driver. 1. If the driver can t detect the hardware, please remove the hardware and then plug it in properly. 2-2

Software Operation 3. Software Operation 3.1 Start Executing Program In Start -> All Programs, choose CLAMP-ON Graphic Power Quality Analyzer to start executing program. Choose the Serial Port connected to CLAMP-ON Graphic Power Quality Analyzer. 1. Click to choose the serial port number connected to CLAMP-ON Graphic Power Quality Analyzer. 2. After choosing correct serial port number, click to confirm. 3-1

Software Operation 3.2 Functions of Main Screen Get in the main screen of software operation. 1 2 1. Tool bar including functions like: Setting parameters, Communication, Download/Clear datalogger, Information of software version, and Exit. 2. System messages including: initial status, present status, down-load percentage, etc. 3-2

Software Operation 3.3 Setting Parameters click File -> Setup of tool bar to get in parameter-setting screen. Parameters including date/time, datalogger, system, etc. After being set in Application Program, the parameters are written in the memory of CLAMP-ON Graphic Power Quality Analyzer. 1 2 1. Click to set date and time. 2. Click to finish setting. 3-3

Software Operation Datalogger-setting including: Sample, Start time and Stop time of sampling, Waveform point of sampling. System-setting including: Voltage Transformer (VT), Transient Reference Voltage (TRANS REF) and its range (%), Frequency (Hz), Max. Demanding Time (MD Time) and Auto power off. 3-4

Software Operation 3.4 Communication Click <Communication> of tool bar to get in Communication screen. To perform this Communication function, the range of CLAMP-ON Graphic Power Quality Analyzer should be adjusted to 3 Phase, 1 Phase, V, A, or VA. 1 2 1. Too bar including: File open (Open), File save (Save), File close (Close), Max. demanding time and Sampling rate (MD Time & Sample Rate), Screen printing (Print), Curve graphing (Waveform), Choosing operation mode (View), Exit. 3-5

Software Operation 2. Communication messages including: Present time (Current Time), Start time of sampling (Start Time), Max. Demanding Time and Present sampling rate (MD Time, Sample Rate), Voltage Transformer (VT), Frequency (Frequency), number of sample already recorded (Sample Count), sample showed at present (Present Sample). 3.5 Down Load Data Click Datalogger -> Down Load Data (Ctrl+D) of Tool bar to get in Down Load Data. The system message shows the current down load %. To stop downloading, press Reset on the right of screen. 3-6

Software Operation 3.6 Clear Memory Click Datalogger -> Clear Memory (Ctrl+C) of tool bar to get in Clear Memory screen. Click Clear Memory in the dialogue to clear the memory of CLAMP-ON Graphic Power Quality Analyzer. Once the memory of CLAMP-ON Graphic Power Quality Analyzer has been cleared, it can t be recovered anymore. If it s necessary to save the memory, first down load it and then save it in PC (refer to chapter 4.5). 3-7

Communication 4. Communication The software will display what is shown in the LCD of analyzer. Users should press the FUNC button to select display. 4.1 Communication Screen I Adjust the sliding switch of CLAMP-ON Graphic Power Quality Analyzer to 3 Phase (or 1Phase), and Click Communication to get in Communication screen. 1 2 3 1. Display of Apparent Power (S) and KVAH, True Power (P) and KWH, Reactive Power (Q) and KVARH. 2. Display of Average demanding (Ave.), Max. Demanding (Max.). 3. Display of Power factor (PF), PFH, Phase angle, Horse power (HP). 4-1

Communication 4.2 Communication Screen II Adjust the sliding switch of CLAMP-ON Graphic Power Quality Analyzer to V and get in Communication screen. After measuring voltage/harmonics, you will get in below screen. (refer to below remarks for the function of current/harmonics measurement). 4 1 3 5 2 1. Display of voltage and waveform. 2. Display of amplitude spectrum. 3. Display of harmonics (selective function). 4. Display of present RMS, Peak, THD. 5. Display of magnitude, percentage. 4-2

Communication 4.3 Communication Screen III Adjust the sliding switch of CLAMP-ON Graphic Power Quality Analyzer to VA and get in Communication screen. After measuring voltage/current/waveform, you will get in below screen. 1 2 1. Display of voltage, current and waveform. 2. Display of present P, S and Phase readings. 4-3

Communication 4.4 Communication Screen IV Adjust the sliding switch of CLAMP-ON Graphic Power Quality Analyzer to VA and get in Communication screen. After measuring voltage/waveform, you will get in below screen. (refer to below remarks for the function of current/waveform measurement). 1 2 1. Display of voltage and waveform. 2. Display of present RMS and Peak readings. 4-4

Communication 4.5 Open / Save Data You can Open/Save the data of Communication screen or the down-load data from/to PC. Click File -> Save (Ctrl+S) in Communication screen, the data of the present screen can be saved as.csv files. 1 The down load information of transient data includes: Transient starting time (Start Time), Duration of transience (Duration), End time of transience (End Time), Higher than set voltage (High), Lower than set voltage (Low) and Opening circuit (Open). 4.6 Setting MD Time & Sample Rate 4-5

Communication Click File -> MD Time & Sample Rate in Communication screen and then click Setting in the dialogue. The max. demanding time (MD Time) and sampling rate (Sample Rate) can be reset. When you finish setting parameters and press Enter, the recorded data will be cleared (Reset). If you want to save this data, you must save it before resetting MD Time & Sample Rate. 4-6

Communication 4.7 Choosing Printer Click File -> Print in Communication screen, and then click beside the Name column to choose the printer you d like to use. There is also a printer-selection function in Waveform function. 4.8 Waveform Click Waveform in Communication screen, then choose the waveform name that you want. In various Communication screens, you can choose among the following waveform names: Communication screen I : V, A, S, P, Q, PF, Phase, KVAH, KWH, KVARH, PFH, VA(AD), W(AD), VA(MD), W(MD) Communication screen II : RMS, Peak, THD Communication screen III : V, A, P, S, Phase Communication screen IV : RMS, Peak 4-7

Communication 4.9 Waveform Redrawing In Waveform screen, you can adjust Scale and Cursor position manually to observe readings. If you improperly adjust Scale or Cursor position, click File -> Redraw to perform Waveform redrawing which can automatically make a proper adjustment. 1 3 2 4 1. Display readings of present cursor position. 2. Draw chosen waveform. 3. Adjust present cursor position (or drag the cursor). 4. Click Scale input values to change observation range. 4.10 Printing Waveform 4-8

Communication Click File -> Print to perform waveform printing function which can output the present observed screen to a printer. (There is also a printing function in Communication screen). 4.11 Operation Modes Operation modes include Real Time mode, History mode, File mode. Choose the mode you want in Communication screen by clicking View to get in the chosen mode. Real Time mode: Real-time display the present reading in Communication screen. History mode: observe the previous data of readings; keep data logging. File Mode: open the saved data of readings. 4-9

Communication 4.12 Mode Resetting Execute View -> Reset function, then all the present data will be reset and recorded again, and the Mode will be returned to Real Time mode. 1 2 1. Choose operation mode and mode resetting. 2. Choose present displayed data (only available under History mode and File mode). 4-10