Reducing Data Center Cooling Costs through Airflow Containment

Similar documents
Data Center Airflow Management Basics: Comparing Containment Systems

Reducing Energy Consumption with

Moving Containment Inside the Enclosure. Jeff Markle Great Lakes Case & Cabinet

Power and Cooling for Ultra-High Density Racks and Blade Servers

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

Impact of Air Containment Systems

Where s the Heat Coming From. Leland Sparks Global Account Technical Consultant Belden

High Tech Getting Too Hot? High Density Environments Require A Different Cooling Approach

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

ENCLOSURE HEAT DISSIPATION

DATA CENTER EFFICIENCY: Data Center Temperature Set-point Impact on Cooling Efficiency

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

Rittal Cooling Solutions A. Tropp

Thermal management. Thermal management

A Green Approach. Thermal

Recapture Capacity for Existing. and Airflow Optimization

AisleLok Modular Containment vs. Legacy Containment: A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings

Current Data Center Design. James Monahan Sept 19 th 2006 IEEE San Francisco ComSoc

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

MSYS 4480 AC Systems Winter 2015

Data Center Enclosures Best Practices. Maximize the Efficiency of the Enclosure within a Data Center

Reclaim Wasted Cooling Capacity Now Updated with CFD Models to Support ASHRAE Case Study Data

A) Differences between Precision and Comfort Cooling Here are the major differences exist between precision air conditioning and comfort systems.

Running Your Data Center Under Ideal Temperature Conditions

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

Effectiveness and Implementation of Modular Containment in Existing Data Centers

Avoidable Mistakes that Compromise Cooling Performance in Data Centers and Network Rooms

Data center cooling evolution. The hottest way to save energy. Lucio Bustaffa: Product Development Manager BlueBox Group

Ten Cooling Solutions to Support High- Density Server Deployment

To Fill, or not to Fill Get the Most out of Data Center Cooling with Thermal Blanking Panels

Datacenter Efficiency Trends. Cary Roberts Tellme, a Microsoft Subsidiary

Rittal White Paper 506: Cold Aisle Containment for Improved Data Center Cooling Efficiency By: Daniel Kennedy

Google s Green Data Centers: Network POP Case Study

APC APPLICATION NOTE #146

survey, 71% of respondents listed Improving capacity planning as a top driver for buying DCIM 1.

Next Generation Cooling

Design and Installation Challenges: Aisle Containment Systems

Using CFD Analysis to Predict Cooling System Performance in Data Centers Ben Steinberg, P.E. Staff Applications Engineer

HIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM.

Liebert DCW Family Chilled Water-Based High Density Cooling For The Data Center. Precision Cooling For Business-Critical Continuity

HIGHLY EFFICIENT COOLING FOR YOUR DATA CENTRE

Precision Cooling Mission Critical Air Handling Units

Rethinking Datacenter Cooling

Air Containment Design Choices and Considerations

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

Schneider Electric Cooling Portfolio. Jim Tubbesing Heath Wilson APC/Schneider North Texas Rep Tubbesing Solutions

INNOVATE DESIGN APPLY.

PROCESS & DATA CENTER COOLING. How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES

Data Center Energy and Cost Saving Evaluation

Close Coupled Cooling for Datacentres

Data Center Temperature Design Tutorial. Ian Seaton Chatsworth Products

Five Strategies for Cutting Data Center Energy Costs Through Enhanced Cooling Efficiency

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

Total Modular Data Centre Solutions

Liebert DCW CATALOGUE

Ten Cooling Solutions to Support High-density Server Deployment. Schneider Electric Data Center Science Center White Paper #42

Energy Logic: Emerson Network Power. A Roadmap for Reducing Energy Consumption in the Data Center. Ross Hammond Managing Director

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.

INNOVATE DESIGN APPLY.

Temperature monitoring and CFD Analysis of Data Centre

A LAYMAN S EXPLANATION OF THE ROLE OF IT RACKS IN COOLING YOUR DATA CENTER

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Optimizing Cooling Performance Of a Data Center

ECOBAY: Closed loop water cooled server cabinet for data centers

Survey and Audit Service Schedule. Airflow and Thermal Imaging Survey Service Schedule. Data Centre Solutions Expertly Engineered

TWO FINANCIAL IMPACT STUDIES. Seal IT Equipment Cabinets for Significant Annual Cost Savings and Simple Payback in a Few Short Months

Introducing the Heat Wheel to the Data Center

The Efficient Enterprise. All content in this presentation is protected 2008 American Power Conversion Corporation

COOLING SOLUTIONS. SmartRack Close-Coupled Cooling for IT Environments

Airflow Management s Role in Data Center Cooling Capacity

Efficiency of Data Center cooling

The Energy. David L. Moss Dell Data Center Infrastructure

Variable Density, Closed-Loop, Water-Cooled Data Center Solution

Evaporative free air cooling technology Providing evaporative free air cooling solutions.

Power & Cooling Considerations for Virtualized Environments

New Techniques for Energy-Efficient Data Center Cooling

Fundamentals of CFD and Data Center Cooling Amir Radmehr, Ph.D. Innovative Research, Inc.

Precision Cooling. Precision Cooling Advantages

Virtualization and consolidation

How to Sell APC s Cisco Approved Solution for Nexus 7018

Energy Efficient Data Centers

Cabinet Level Containment. IsoFlo Cabinet. Isolated Airfl ow Cabinet for Raised Floor Data Centers

Is Data Center Free Cooling Feasible in the Middle East? By Noriel Ong, ASEAN Eng., PMP, ATD, PQP

84 kw, Tier 3, Direct Expansion, 937 ft 2

Liquid Cooling Package LCP Cooling Systems

Switch to Perfection

Data Center Energy Savings By the numbers

Five Best Practices for Increasing Efficiency, Availability and Capacity: The Enterprise Data Center Design Guide

HP Modular Cooling System: water cooling technology for high-density server installations

DATA CENTER LIQUID COOLING

Cisco Lab Setpoint Increase. Energy Efficient Data Center Demonstration Project

REPORT. Energy Efficiency of the San Diego Supercomputer Center and Distributed Data Centers at UCSD. Prepared for:

Environmental Data Center Management and Monitoring

Optimiz Chilled January 25, 2013

Energy Efficiency Best Practice Guide Data Centre and IT Facilities

Planning a Green Datacenter

Trends in Data Center Energy Efficiency

Implementing Hot and Cold Air Containment in Existing Data Centers

The Four 4R s. of Data Center Airflow Management. About Upsite Technologies

Close-coupled cooling

Transcription:

FEATURE Reducing Data Center Cooling Costs through Airflow Containment Implementing a containment solution in the data center costs much less than the alternatives of adding air handlers or other supplemental cooling equipment. Data center managers often configure cabinets in open hot/cold aisles and oversupply the room with cool air to keep equipment at operating temperature ranges. But that hurts efficiency and greatly inflates the energy bill. By DAVID KNAPP Chatsworth Products Agoura Hills, CA Data centers are one of the most energyhungry facilities out there, and as computing processors become more advanced, the average heat load per cabinet is rising. A traditional approach many data center managers take is to configure cabinets in Figure 1. Sectional view of several ducted exhaust cabinets with Vertical Exhaust Ducts showing airflow through the cabinets and through the room. Note: Hot exhaust air is isolated and removed from the room through the Vertical Exhaust Ducts. open hot/cold aisles and oversupply the room with cool air to keep equipment at operating temperature ranges. This, however, minimizes ef- An 18-year veteran with Chatsworth, the author is a product marketing manager focused on data center, enterprise networking, and power management solutions. 16 HPAC ENGINEERING MARCH 2018

ficiency and adds thousands of dollars in the energy bill. Using a containment system with perimeter cooling is still an excellent solution for today s average rack densities and the anticipated densities over the next decade. Furthermore, containment systems support retrofit from hot aisle/cold aisle, economizer applications and free air cooling. Free cooling refers to the number of hours that the economizer can be used instead of the chiller. Free cooling is not free, but economizers generally cost less to operate than chillers. The economizer rejects heat outdoors when the outdoor temperature is lower than the temperature of the chilled water loop. So, when the chilled water loop temperature increases, there are typically more hours that the economizer can be Figure 2. Sectional view of a HAC solution with ducts constructed over the hot aisles, showing airflow through the contained aisles and the room. Note: Hot exhaust air is isolated and removed from the room through the ducts over the contained hot aisles. Figure 3. Sectional view of a CAC solution with ceilings constructed over the cold aisles showing airflow into the contained aisles and through the cabinets and back to the cooling units through the room. Note: Hot exhaust air is isolated within the room by the ceilings over the contained cold aisle. Your VAPOR ZONE Protection Never Fear Moisture and Humidity Again! The perfect insulation for Aerocel ULP is ideal for hot, humid, and high moisture conditions. New Insulation Aerocel ULP is ideal for hot and humid climates where moisture is always a problem. Cost effective alternative to cellular glass and other rigid foams Lowest permeance value of.005 perm-inch / lowest absorption rate of.1% by volume Ultra-low water vapor transmission system stays sealed against moisture Ideal for extreme hot or cold high-humidity / high-moisture applications For more information go to: www.aeroflexusa.com/ulp Or call: 1-866-237-6235 (1-866-Aerocel) 1-866-237-6235 (1-866-AEROCEL) www.aeroflexusa.com Done once. Done fast. Done right. Circle 159 MARCH 2018 HPAC ENGINEERING 17

FEATURE Table 1. Summary of 2015 Thermal Guidelines from ASHRAE Datacom Series 1, Thermal Guidelines for Data Processing Environments, Fourth Edition, (RP-1499). Refer to the guideline for the complete environmental recommendation. Note: Maximum elevation is 10,000 feet (3,050 meters) above sea level, and maximum rate of change is 9 F over 36 hours (5 C over 20 hours) operated instead of the chiller. As an added bonus, higher chilled water temperature also typically improves chiller efficiency. Three Methods of Containment There are three basic methods of complete containment, and regardless of which method you choose,you Circle 160 will improve the efficiency of a chilled water perimeter cooling system. Ducted exhaust cabinets are enclosed server rack cabinets with an attached Vertical Exhaust Duct. As pictured in Figure 1, the hot exhaust air given off by the servers is enclosed within the cabinet, completely isolating the air from the room. The hot air exits the cabinet through the overhead vertical exhaust duct, which directs the hot air into a plenum above the drop ceiling and back to the cooling units (shown) or to outside vents. Hot aisle containment (HAC) is the most popular type of containment solution used today. In this method, a configuration of duct work and baffles are set up over the hot aisle, with doors blocking the aisle entrances at either end. As shown in Figure 2, the HAC solution contains and isolates the hot exhaust air from the room, preventing it from reaching the adjacent cold aisles and mixing with the cold air. The hot exhaust air in the hot aisles is then returned to the cooling units, usually through drop ceiling plenums. Cold aisle containment (CAC) configurations are typically used to retrofit data center environments where a raised floor cooling system already exists. As seen in Figure 3, a roof and/or partitions are set up over the cold aisle, with doors at either end. This isolates the cold intake air within the cold aisle, keeping it separate from the hot air in the neighboring hot aisles. The hot exhaust air rises up freely in the hot aisles, and returns through the room to the air handlers. Prevent Recirculation, Bypass Airflow Effective airflow management and cooling cost reduction also requires the elimination of bypass airflow within or through the cabinet, utilizing the following best practices, as shown in Figure 4: Use proper racking techniques to block airflow around rack-mount equipment; 18 HPAC ENGINEERING MARCH 2018

Table 2. Table comparing the cooling capacity of chilled water cooling units as the return air temperature increases (left-to-right). Note: Values are in MBH (thousand BTU/hr), so 124 MBH is 124,000 BTU/hr. For conversion: 12 MBH (or 12,000 BTU/hr) = 3.5 kw (or 3,516 W) = 1 ton (refrigeration). Source: STULZ CyberAir CW Engineering Manual. Use blanking panels to seal all unused rack-mount spaces to block airflow between rack-mount equipment; Use air dams and seals around rack-mount equipment to prevent recirculation of hot air around the sides of the equipment; Use seals around cable openings in the cabinet body and raised floors; Use seals between cabinets to block airflow between cabinets into the contained space; Use panels to block airflow under the cabinet into the contained space. Reducing Temperature Variations The first noticeable effect when implementing a complete containment system is the change in room temperature. Containing hot exhaust air reduces or eliminates hot An Effective Seal is Critical When selecting a containment solution, you should take seal into account. Containment vendors typically describe system seal performance in terms of leakage, typically a percentage based on a particular volume of airflow to each cabinet under a specific operating pressure. When comparing these values, be aware that conditions may not match. The volume of airflow should be the maximum sustainable volume across the entire room at the planned static pressure during operation. For example, an optimal containment system performance is 3000 CFM (5097 CMH) of exhaust airflow per cabinet at.05 inches of water (.01 kpa) with less than 5-percent leakage. Managing Pressure Establishing a good seal in your containment system is not just a matter of having containment barriers without leaks. It also requires total pressure management of the contained environment, particularly with CAC. A complete containment architecture should include an effective pressure differential management system. This may include updating or introduction of HVAC controls. Circle 161 MARCH 2018 HPAC ENGINEERING 19

FEATURE spots by blocking the recirculation and preventing the mixing of supply and exhaust air. As a result, the temperature variation across the front of racks is reduced, as shown in Figure 5. Reduce Volume of Supply Air Complete containment also typically allows the volume of air delivered to equipment to be reduced. Traditional hot aisle/cold aisle systems are often oversupplied in an attempt to overcome bypass airflow over and around cabinets. The volume of airflow can typically be reduced once containment is in place. In existing sites with air handlers that do not have variable speed fans, this means turning some units off, resulting in some savings from reduced energy consumption. In sites with units that have variable speed fans, the fan speeds can be reduced to take advantage of fan affinity laws. Fans use less overall energy when running at reduced speed (partial capacity) because they are moving less air. Essentially, all units are run at low partial capacity instead of several units at full capacity. This configuration still provides capacity for N+1 redundancy or better, if needed, while maintaining reduced energy costs. Increase Supply Air Temps Because containment results in less temperature variation in supply air, operators can reliably increase room temperatures closer to required inlet temperatures on equipment. The ASHRAE Datacom Series 1, Thermal Guidelines for Data Processing Environments, Fourth Edition (RP-1499) defines recommended and allowable equipment environment specifications for air cooling in data center computer rooms, see Table 1. When complete isolation between hot and cold aisles is achieved, recirculation of hot return air is eliminated. Much lower temperature air is no longer necessary to overcome Figure 4. Sectional view of cabinets showing bypass airflow around equipment (left) and showing good airflow management guiding air through equipment and blocking recirculation (right). It is critical to utilize baffles and blanking panels within cabinets to seal openings that would allow air to bypass equipment. All air that passes through the cabinet should pass through equipment, and transfer heat away from equipment and out of the cabinet. Figure 5. Containing hot exhaust air reduces or eliminates hot spots by blocking the recirculation and preventing the mixing of supply and exhaust air. As a result, the temperature variation across the front of racks is reduced. air mixing, and it is possible to safely raise the temperature of the supply air up to the recommended 64.4 F to 80.6 F (18 C to 27 C) range. The advantage of increasing the temperature of supply air is improved cooling unit efficiency as a result of the corresponding higher return air temperatures and access to more free cooling hours when using economizers. Increase Chilled Water Temps In chilled water systems, fluid is used to transfer heat between air handlers and chillers and/or economizers. Depending on required conditions and system design, it may also be beneficial to raise the temperature of the chilled water (fluid). The advantage of increasing the temperature of chilled water is im- 20 HPAC ENGINEERING MARCH 2018

Leaders in-venting Innovation Grease Duct With No On-Site Welding Required! As long as there is complete isolation between hot and cold air, and the necessary power, cooling and airflow, it is possible to run high-density server loads at higher temperatures. proved chiller efficiency when using mechanical cooling and access to more free cooling hours when using economizers. Improved Cooling Efficiency With chilled water cooling units, increasing return air temperature generally results in increased sensible cooling. See Table 2. In existing facilities, this relationship typically allows higher densities in the data center once containment allows reliable airflow separation and temperature control. In new construction, this relationship can be used to optimize the sizing of units for anticipated heat loads, reducing first cost and project capital expenditure. Positive Bottom Line For existing data center installs, effective airflow management with a containment system offers two overall benefits: 1. It lowers operational expenses (OpEx) by reducing the power consumption necessary to provide cooling to the data center environment. 2. It allows data center operators to increase server capacity in the data center. As long as there is complete isolation between hot and cold air, and the necessary power, cooling and airflow, it is possible to run high-density server loads at higher temperatures, while providing the servers with adequate cooling to prevent overheating and shutdowns. As a final note, it is important to know the exact results of containment will vary for each site. Overall performance, the initial cost of the system (CapEx), the estimated operating cost (OpEx), resulting savings and return on investment will also vary. To learn more about the economics of airflow containment, view this CPI white paper: http://pages. chatsworth.com/economics-of-containment-white-paper.html. Strong. Superior. Clean. 800-361-4909 US 800-667-3387 Canada For READY TO INSTALL instructions visit: www.securitychimneys.com Circle 162 MARCH 2018 HPAC ENGINEERING 21