MiCOM P13x AREVA T&D. Feeder Management Relays

Similar documents
MiCOM P139 Feeder Management and Bay Control

MiCOM P122C Time-Overcurrent Protection

MiCOM P124 T&D. Self and Dual Powered Overcurrent Relays

MiCOM P12x/y AREVA T&D. Three phase and earth fault overcurrent relays

MiCOM P220, P225 and P226C

MiCOM P521. Fast feeder differential protection

Three phase and earth fault overcurrent relays

MiCOM P521. Fast Feeder Differential Protection

MiCOM P14x AREVA T&D. Feeder Management Relays

Recloser Controller for feeder protection and automation siemens.com/distribution-automation

Perfect protection smallest space

MiCOM P12x/y. Three phase and earth fault overcurrent relays

SIPROTEC 7SC80 Feeder Protection and Automation Answers for infrastructure and cities.

Numerical motor protection in medium voltage networks Motor Protection and Control REM620

SYMAP R Plug in Variants FI, MI, 87M, TI Technical data

MiCOM P521. Fast Feeder Differential Protection. Protection Relays. MiCOM P521 CUSTOMER BENEFITS

TWO-WINDING TRANSFORMER DIFFERENTIAL

Substation Automation Products. Line differential protection RED670 Relion 670 series

Power Systems Communications Implementation of IEC61850 in a Substation Environment

NEO 3000 Substation System THE FAMILY OF EQUIPMENT DEDICATED FOR POWER UTILITIES. Energy Sector

Relion 615 series Feeder Protection and Control REF615 Ver. 2.0 Technical Presentation

REL52002 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: V, DI: V, RS-485

Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage

MiCOM Protection 20, 30 and 40 Series Relays Key Features

MiCOM P342/3/4/5 Generator Protection Relays

DS Agile C264. Grid Solutions. Dual-bay Modular Substation Controller. Multi-function Controller. Automation and Control. Advanced Communication

Content REF615 Technical Presentation

MiCOM P124. Self and Dual Powered Overcurrent Relays. Protection Relays

Maximize protection. Sepam series 10, 20, 40, 60, 80. Modular range of digital protection relays

GE Multilin 350 Feeder Protection Relay Specifications

RELAYABLE POWER. AQ 200 series protection, control, measurement and monitoring IEDs

SR489 SR489. Generator Management Relay. Economical protection, metering, and monitoring functions for small and medium sized generators.

Relion 615 series Line Differential Protection and Control RED615 Ver. 2.0 Technical Presentation

Protection relays.

Transformer Protection and Control RET630 Numerical transformer protection in medium voltage networks

Substation Automation Products. Line distance protection REL670/650 Relion 670 and 650 series

Perfect protection smallest space

PROTECTION, AUTOMATION & CONTROL

Overcurrent and Arc Protection by Reyrolle Alexander Erokhin. 21, 2017 I Berlin

Substation Automation Products. Generator protection REG670/650 Relion 670 and 650 series

7SR21 Non-Directional 7SR22 Directional Overcurrent Relay

REL52001 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: V, DI: V, 2 x RJ-45

RELAYABLE POWER. AQ-200 series protection, control, measurement and monitoring IEDs

Agile P24xM. Grid Solutions. Protection and Control. Motor Management Series. Metering and Monitoring. Advanced Communications.

S o m e t h i n g b e t t e r t h a n p r o t e c t i v e r e l a y s. automation, control & communication

RELAYABLE POWER. AQ 200 series protection, control, measurement and monitoring IEDs

Function permission: yes/no. Operating range: 0.10 to 30 xin (step 0.01) Operating time: 0.02 to 300 s (step 0.01 s) Activation level 100%

Products Portfolio. Pole mounted Vacuum Recloser

Feeder Protection Relay REF 610. Product Guide

Price guide SEPAM, MiCOM & VAMP Ranges Automtion business unit

Maximize process uptime with the SEL-patented motor thermal model.

Substation Automation Products. Bay control REC670/650 Relion 670 and 650 series

Siprotec 7ST61 / 7ST63

Protect induction and synchronous motors with one relay.

Relion 615 series Transformer Protection and Control RET615 Ver. 2.0 Technical Presentation

MiCOM P14x. Feeder Management Relays

MiCOM P14x. Feeder Management Relays. Protection Relays

MiCOM Agile P541 & 542. Grid Solutions. High-speed current differential unit protection. Key Benefits. Key Features. Current Differential Protection

Branch Procedure. Document No. Issue No. : : 29/06/ /06/2021 (Supersedes CEOP8012, Generation Connection: Protection Guidelines, Issue 4.

Protect induction and synchronous motors with one relay

Content FPC 400. USER MANUAL Apr Feeder F3 Motor M4 Busbar B3 Transformer T4

Approval...6. Current Revision...7. Introduction... 8 About PJM Manuals... 8 About This Manual... 8 Using This Manual...9

Feeder protection relay SPAA 121 C. Product Guide

SIPROTEC 4 7SJ64 Multifunction Protection Relay with Synchronization

Application Notes on Generator Protection Schemes

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field

Protection, Monitoring, and Control System for Distribution Substations ALARM HISTORY SYSTEM COMM. On-Line Documentation TRANSFORMER 12 MW

7SR242 Duobias Multi-Function 2-Winding Transformer Protection Relay

Protection Relays Guide

SIPROTEC 5 Application Note. Breaker-and-a-half solutions. SIP5-APN-002, Edition 2.

SOLKOR-N (7SR18) Feeder Differential Protection. Make the ight choice! Choose EYROLLE Protection

Feeder Protection REF615 Ver Technical Presentation. ABB Oy Distribution Automation. Prashant Ganoo Regional Product Marketing Manager

MP-4000 motor protection. Protection, control and diagnostics

INTRODUCTION. The PL-50 MO and PM-250 families represent the. PM-250-H: Horizontal box. PM-250-V: Vertical box

Current Matters. The Device issue. Siemens Protection Devices Ltd. In-depth looks at some of our best and most versatile products to date

Metering Devices, Protective Relays, Software and Connectivity. Pre-Wired Control Power, Voltage and CT Inputs

SIPROTEC 5 Application Note

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

SACE Emax 2 Specification guide

Landsnet-Icegrid. Requirements for protection and control systems. Principles for the Icelandic power transmission network.

1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection

Substation Automation Products. Transformer protection RET670/650 Relion 670 and 650 series

Session Five: IEC61850 Based Process Bus Protection Solution for Remote Located Power Transformers

ENhanced TEChnology. Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV. Ver.

Protective Relays & SCADA Systems

MiCOM P721 & P723. Numerical High Impedance Differential Relay. Protection Relays. Customer Benefits

Substation Automation Products. High impedance differential busbar protection REB650 Relion 650 series

2008 Many Changes in IEEE C37.2. IEEE Standard Electrical Power System Device Function Numbers, Acronyms and Contact Designations

e 2 TANGO -400 Overcurrent Relay K Catalogue EN

MiCOM Alstom P14N, P14D, P94V

UR Universal Relay Series

EDR-3000 Eaton Distribution Relay

SIPROTEC Compact Overcurrent Protection 7SJ81 for Low-Power CT and VT Applications

U lity network. system Q sys. Interconnected P sys. P load Q load. P gen Q gen. Generator network

7SR21 Non-Directional 7SR22 Directional Overcurrent Relay

DIGITAL RELAY OF PROTECTION AND AUTOMATION SERIES PC83 AND PC830

Busbar protection REB 670

Catalog Edition 6 siemens.com/protection

BITRONICS 878 DIOD Product Description BITRONICS 878 DIOD DISTRIBUTED INPUT/OUTPUT DEVICE

POWER GRID AUTOMATION. Pág.. n. RMU Automation

Transcription:

MiCOM P13x Feeder Management Relays The time-overcurrent protection devices of the MiCOM P13x range are designed for selective short-circuit protection, ground fault protection and overload protection. They can be applied in all types of medium- and high-voltage systems. compact P130C The broad spectrum of protection functions enables the user to cover a wide range of applications in the protection of cables and overhead lines, transformers and motors. In addition, numerous control functions are available. Thanks to the provision of four setting groups, the P13x devices are readily adapted to varying conditions in system operation. The intuitive user interface as well as the various communication interfaces allow simple and comprehensive setting as well as access to readings from extensive recordings. Numerous integrated communication protocols provide interfacing to almost any kind of substation control or SCADA system. modular P132 Furthermore the integrated InterMiCOM protection interface provides direct end-to-end communication between two protection devices. The particularly flat compact case of the P130C as well as the standard 19'' modular case of the P132 with a user-selected number of plug-in modules provide a flexible solution for easy integration of the devices into the substation. Both case variants are available for flush mounting and wall-surface mounting. Customer Benefits 1A/5A software setting Two communication interfaces (for SCADA/RTU and remote access) Function keys Optional Bay control AREVA T&D

APPLICATION Overcurrent protection devices MiCOM P13x provide a wide range of protection functions. For the different requirements in system protection the integrated functions follow the availability of CT and VT inputs (order options). As a result the preferred applications are as follows: > P130C with VT: Voltage and Frequency Protection > P130C with CT and VT: Directional Time-Overcurrent Protection > P132 with VT: Voltage and Frequency Protection > P132 with CT: Non-Directional Time-Overcurrent Protection > P132 with CT and VT: Directional Time-Overcurrent Protection GLOBAL FUNCTIONS The following global functions are generally available in all devices: > Parameter subset selection (4 alternative setting groups) > Metering > Operating data recording > Overload recording incl. overload data acquisition > Ground fault recording incl. ground fault data acquisition > Fault recording of all CT/VT inputs and binary events incl. fault measurands (e.g. fault location). Functions Overview P130C P130C P132 P132 P132 with VT with CT/VT with VT with CT with CT/VT 50/51 P,Q,N DTOC Definite-time o/c protection, - - three stages, phase-selective 51 P,Q,N IDMT1 Inverse-time o/c protection, - - single-stage, phase-selective 51 P,Q,N IDMT2 Inverse-time o/c protection, - - - single-stage, phase-selective 67 P,N SCDD Short-circuit direction determination - - - 50 SOTF Switch on to fault protection - - 85 PSIG Protective signaling - - 79 ARC Auto-reclosure control (3-pole) - - 25 ASC Automatic synchronism check - - - - option 67W/YN GFDSS Ground fault direction determination - - - TGFD Transient ground fault - - - - option 1) direction determination 37/48/49/ MP Motor protection - - 49LR/50S/66 49 THERM Thermal overload protection - - 46 I2> Unbalance protection - - 27/59/47 V<> Over-/Undervoltage protection - 81 f<> Over-/Underfrequency protection - 32 P<> Directional power protection - - - 50BF CBF Circuit breaker failure protection - - CBM Circuit breaker monitoring - - - MCMOM Measuring-circuit monitoring LIMIT Limit value monitoring - - LOGIC Programmable logic DEV Control and monitoring - - option 1) option 1) option 1) of up to 3 switchgear units SIG_1 Single-pole signals - - option 1) option 1) option 1) CMD_1 Single-pole commands - - option 1) option 1) option 1) ILOCK Interlocking logic - - option 1) option 1) option 1) COMMx 2 comm. interfaces, IRIG-B, protection option option option option option comm. interface InterMiCOM IEC IEC-61850-interface - - option option option F_KEY Function keys 4 4 6 1) 6 1) 6 1) INP/OUTP Binary inputs and output relays 2/8 2/8 40/30 1) 40/30 1) 40/30 1) (max.) MEASI/MEASO 2x 20 ma outputs, 20 ma input, - - option 1) option 1) option 1) 1 RTD input MEASI 9 RTD inputs - - - option 1) option 1) 1) Not available for P132 in 24TE case 2>3 MiCOM P13x provide a wide range of protection functions.

MAIN FUNCTIONS Main functions are autonomous function groups and can be individually configured or disabled to suit a particular application. Function groups that are not required and have been disabled by the user are masked completely (except for the configuration parameter) and functional support is withdrawn from such groups. This concept permits an extensive scope of functions and universal application of the device in a single design version, while at the same time providing for a clear and straight-forward setting procedure and adaptation to the protection and control task under consideration. Simple Function Selection by Mouseclick FUNCTION DIAGRAMS Communication COMM1 COMM2 to SCADA / substation control / RTU / modem... via RS485 or Fibre Optics using IEC 60870-5-101, -103, Modbus, DNP3, Courier 85 PSIG InterMiCOM LOGIC IRIGB Self Monitoring LIMIT Recording and Data Acquisition Metering Overload rec. Ground flt. rec. Fault rec. 50/51 P,Q,N DTOC 51 P,Q,N IDMT 67 P,N SCDD 50 SOTF 49 THERM 37/48/49/50S/66 MP 46 I2> MCMON 79 ARC 67W/YN GFDSS I V 27/59/47 V<> 81 f<> 32 P<> 50BF CBF always available with CT inputs further options Feeder Management / Frequency Protection P130C V ref Control/Monitoring of up to 3 switchgear units DEV ILOCK Communication COMM1 COMM2 IEC to SCADA / substation control / RTU / modem... via RS485 or Fibre Optics using IEC 60870-5-101, -103, Modbus, DNP3, Courier resp. via RJ45 or Fibre Optics using IEC 61850 InterMiCOM IRIGB 85 PSIG LOGIC Self Monitoring LIMIT Recording and Data Acquisition Metering Overload rec. Ground flt. rec. Fault rec.. 50/51 P,Q,N DTOC 51 P,Q,N IDMT_1 51 P,Q,N IDMT_2 67 P,N SCDD 50 SOTF 49 THERM 37/48/49/50S/66 MP 46 I2> CBM MCMON 25 ASC 79 ARC 67W/YN GFDSS TGFD I V 27/59/47 V<> 81 f<> 32 P<> 50BF CBF SIG_1 CDM_1 MEASI MEASO always available with VT inputs further options Feeder Management and Bay Control Unit P132 1) 1) Function diagram for P132 with CT inputs and P132 with CT and VT inputs in 40TE resp. In 84TE case Function overview for P132 with VT inputs only resp. In 24TE case please see table "function overview".

TIME-OVERCURRENT For the overcurrent protection of the three phase currents, the residual current and the negativesequence current the P13x provide definite time overcurrent protection and inverse time overcurrent protection with a multitude of tripping characteristics. The operate values of all overcurrent stages can dynamically changed (e.g. under cold load pickup conditions). Additionally, some of the phase and negative-sequence current stages can be stabilized under inrush conditions if desired. The residual and negative-sequence current stages affect the general starting signal. This effect can be suppressed if desired. Directional characteristics in short circuit direction determination Meas. Starting Variables selected for measurement Characteristic system I V meas meas angle αp or αn P A I A V BC = V BN - V CN +45 B I B V C A = V - CN V AN +45 C I C V AB = V AN - V BN +45 A-B I A V BC = V BN - V CN +60 B-C I C V AB = V AN - V BN +30 C-A I C V AB = V AN - V BN +60 A-B-C I C V AB = V AN - V BN +45 G GF I N V NG = -90...+90 1/3. (V AN +V BN +V CN ) (adjustable) Forward decision I meas Tripping time characteristics V meas (reference var.) Backward decision No. Tripping time characteristic Constants and formulae (t in s) (k = 0.01...10.00) a b c R 0 Definite Time t = k Per IEC 255-3 a 1 Normally inverse 0.14 0.02 t = k b I 2 Very inverse 13.50 1.00 1 I ref 3 Extremely inverse 80.00 2.00 4 Long time inverse 120.00 1.00 Per ANSI/IEEE C37. 112 Trip Release 5 Moderately inverse 0.0515 0.0200 0.1140 4.85 6 Very inverse 19.6100 2.0000 0.4910 21.60 7 Extremely inverse 28.2000 2.0000 0.1217 29.10 Per ANSI Trip Release 8 Normally inverse 8.9341 2.0938 0.17966 9.00 9 Short time inverse 0.2663 1.2969 0.03393 0.50 10 Long time inverse 5.6143 1.0000 2.18592 15.75 a t = k + c b I 1 Iref t = k I I ref R 2 1 SHORT-CIRCUIT DIRECTION DETERMINATION Due to the short-circuit direction determination function, the P13x can be used as directional time-overcurrent protection devices. For the individual overcurrent stages the user can select whether the stage shall be forwarddirectional, backward-directional or non-directional. Direction determination is performed in separate measuring systems for the phase current and residual current elements, respectively. Not per standard 11 RI-type inverse 1 t = k 0.236 0.339 I Iref 12 Not per standard RXIDG-type inverse I t = k 5.8 1.35 ln Iref 4>5 MiCOM P13x for rapid and selective fault clearance in your power system.

SWITCH ON TO FAULT Closing of a circuit breaker might inadvertently lead to a short-circuit fault due to a maintenance ground clamp not yet removed, for example. The function 'switch on to fault protection' provides for an undelayed protective tripping during a settable time after a manual close command has been issued. MOTOR For the protection of directly switched h.v. induction motors with thermally critical rotor, the following specially matched protection functions are provided: > Recognition of operating mode > Rotor overload protection using a thermal motor replica > Choice of reciprocally quadratic or logarithmic tripping characteristic > Inclusion of heat dispersion processes in the rotor after several startups > Separate cooling periods for rotating and stopped motors > Startup repetition monitoring with reclosure blocking > Control logic for heavy starting and protection of locked rotor Using the optional RTD inputs, direct monitoring of the temperature of the stator windings and the bearings can be set up with the P132. Overload memory and startup counter THERMAL OVERLOAD P13x provide thermal overload protection for lines, transformers and stator windings of h.v. motors. The highest of the three phase currents serves to track a first-order thermal replica according to IEC 255-8. For the P132 the temperature of the cooling medium can be taken into account in the thermal replica using the optional RTD inputs or the optional 20 ma input. The user has a choice of using a thermal replica on the basis of either relative or absolute temperature. OVER-/UNDERVOLTAGE The over- and undervoltage protection allows the multistage evaluation of directly measured and internally calculated voltages. OVER-/UNDERFREQUENCY The four-stage frequency protection can be operated as pure over- and underfrequency monitoring as well as combined with differential frequency gradient monitoring (df/dt) for system decoupling applications or with medium frequency gradient monitoring ( f/ t) for load shedding applications. DIRECTIONAL POWER The directional power protection monitors the active and reactive power limits and detects power drop and reversal of direction. 100 m in % 80 60 40 20 0 3 2 1 Overload memory Permissible number of startups 3 successive startups Reclosure blocking t t GROUND-FAULT DIRECTION DETERMINATION For the determination of the ground-fault direction in isolated or Peterson-coil compensated power systems two proven methods are provided: > Wattmetric or Admittance method (analysis of steady-state signals) > Transient method

(analysis of transient signals) (optional). CIRCUIT BREAKER MONITORING This function provides the user with several criteria for the assessment of circuit breaker wear: > Calculated number of remaining operations based on the CB wear curve > Mechanical operations count > Interrupted currents sum (linear and squared) > Accumulated current-time integrals of trips For each of these criteria, a signaling threshold can be set by the user. AUTO-RECLOSING CONTROL The auto-reclosing control (ARC) operates in threephase mode. ARC cycles with one high-speed reclosing (HSR) and multiple (up to nine) subsequent time-delay reclosings (TDR) may be configured by the user. AUTOMATIC SYNCHRONISM CHECK This option for the P132 can be used in conjunction with automatic or manual (re)closure and the close command of the optional control function. In non-radial networks this ensures that reclosure will proceed only if the synchronism conditions are met. PROTECTIVE SIGNALING Protective signaling can be used in conjunction with short-circuit direction determination. For this purpose the protection devices must be suitably connected by pilot wires or the optional protection interface InterMiCOM on both ends of the line section to be protected. For protection devices on the infeed side of radial networks, teleprotection can also be controlled without the short-circuit direction determination function. MEASURED DATA INPUTS AND OUTPUTS For the acquisition of an externally measured variable or the output of measured datas P139 provides optionally a 0 to 20 ma input and two 0 to 20 ma outputs. A settable scaling allows a simple adaption of the input resp. outputs ranges (e.g. 0 to 10 ma, 4 to 20 ma). Up to 10 optional resistance temperature detectors are provided for direct temperature acquisition. Depending on the set operating mode, the RTD's operate in parallel or the RTD's can be subdivided into regular inputs and reserve inputs. INTERFACE INTERMiCOM Optional InterMiCOM allows high performance permissive and blocking type unit protection to be configured, plus transfer of any digital status information between line ends. Intertripping is supported too, with channel health monitoring and cyclic redundancy checks (CRC) on the received data for maximum message security. InterMiCOM provides eight end-to-end signal bits, assignable to any function within a MiCOM relay's programmable logic. Default failsafe states can be set in case of channel outage. INFORMATION INTERFACES Information exchange is done via the local control panel, the PC interface and two optional communication interfaces. The first communication interface has settable protocols conforming to IEC 60870-5-103, IEC 60870-5-101, DNP 3.0, Modbus and Courier or provides alternatively protocol conforming to IEC 61850 and is intended for integration with substation control systems. The 2nd communication interface (COMM2) conforms to IEC 60870-5-103 and is intended for central settings or remote access. Clock synchronization can be achieved using one of the protocols or using the IRIG-B signal input. Information Interfaces COMM1 or IEC 61850 SCADA / Substation control interface HMI - Local control of switchgear units. Full access to all settings, signals and measurements MODEM MODEM COMM2 Remote access by protection engineer 6>7 PC Local access by protection engineer

FUNCTION KEYS The function keys provide an easy local control of processes or functions by the user. A single function can be assigned to each function key that allows manually opening and closing of the CB, enabling and disabling of functions, a quick navigation with the selected menu jump list or a reset of stored information. For each function key, the user can define an operating mode suitable to the assigned functionality. To guard against inadvertent or unauthorized use each function key is protected with a password. CONTROL The optional control functions of the P132 are designed for the control of up to three electrically operated switchgear units equipped with electrical check-back signalling located in the bay of a medium-voltage substation or a non-complex high-voltage substation. P132 HMI For the selection of the bay type the P132 is provided with a number of predefined bay types. These include the assignment of binary inputs and outputs for the switchgear unit control and monitoring and the interlocking logic. The settings of the predefined bay types can be adapted to the individual needs. The P132 issues switching command outputs with the integration of switching readiness and permissibility tests; subsequently the P132 monitors the intermediate position times of the switchgear units. If a switchgear malfunction is detected, this fact will be indicated (e.g. by an appropriately configured LED indicator). The switchgear units can be controlled via binary inputs, the optional communication interface or the function keys of the HMI. P132 version with detachable HMI Just one Setting File Proven protection with advanced communication and comfortable data handling.

Device Track Record >> PS 451 / PM 481: first multi-functional, numerical time-overcurrent devices launched in 1991, more than 14000 devices installed. >> PS 441: first directional time-overcurrent device in compact case design, more than 9000 devices installed since 1994. >> PS 4x2: numerical time-overcurrent devices with extended functionality, more than 4000 devices installed since 1998. >> PS 4x2 MiCOM Design: Adaption of the PS 4x2 to the MiCOM range design, launched in 2001. >> MiCOM P13x: Complete integration of the PS 4x2 into the MiCOM range, extended functionality and realization of a 'compact-solution' in the MiCOM family. AUTOMATION-L3-P13x-BR-12.07-1772-GB - - AREVA - 2007. AREVA, the AREVA logo and any alternative version thereof are trademarks and service marks of AREVA. MiCOM is a registered trademark of AREVA. All trade names or trademarks mentioned herein whether registered or not, are the property of their owners. - 389191982 RCS PARIS - Printed in France - SONOVISION-ITEP AREVA T&D Worldwide Contact Centre: http://www.areva-td.com/contactcentre/ Tel.: +44 (0) 1785 250 070 www.areva-td.com www.areva-td.com/protectionrelays Our policy is one of continuous development. Accordingly the design of our products may change at any time. Whilst every effort is made to produce up to date literature, this brochure should only be regarded as a guide and is intended for information purposes only. Its contents do not constitute an offer for sale or advise on the application of any product referred to in it. We cannot be held responsible for any reliance on any decisions taken on its contents without specific advice.