NOTICE: This document contains references to Varian. Please note that Varian, Inc. is now part of Agilent Technologies. For more information, go to

Similar documents
LTQ Velos SP3 Release Notes

Agilent G1978B Multimode Source for 6100 Series Single Quad LC/MS

Agilent 6400 Series Triple Quadrupole LC/MS System

Agilent G1978B Multimode Source for 6410 Triple Quad LC/MS

Chromatography Software Training Materials. Contents

For additional information, see these documents on the Breeze 2 software DVD:

Agilent 6100 Series Quad LC/MS System

Agilent MassHunter Workstation Software 7200 Accurate-Mass Quadrupole Time of Flight GC/MS

Data Acquisition with CP-2002/2003 Micro-GC Control

MassLynx 4.1 SCN 804. Release Notes. SQ Detector 2

Installation Instructions

Q Exactive HF-X QuickStart Guide

Operating Manual. High Performance Liquid Chromatograph. Scientific Equipment Center, Prince Of Songkla University

Getting Started. Environmental Analysis Software

TraceFinder Analysis Quick Reference Guide

Agilent GC/MSD Instructions

What s New in Empower 3

Agilent G1732AA MSD Security ChemStation

Steps for LCMS-8040 Triple Quadrupole

Tutorials. Saturn GC/MS Workstation Version 5.4. Varian Analytical Instruments 2700 Mitchell Drive Walnut Creek, CA /usa

Getting low-resolution GC-MS data on the JEOL GCMate Introduction

Residual Gas Analyzers XT Series

Xcalibur. QuickQuan. User Guide. XCALI Revision C July For Research Use Only Not for use in Diagnostic Procedures

Agilent OpenLAB Chromatography Data System A SR1 - Updates

SOFTWARE UPDATE NOTIFICATION (SUN) OMNISEC SOFTWARE v10.31: PSS

Thermo Xcalibur Getting Started (Quantitative Analysis)

Retention Time Locking with the MSD Productivity ChemStation. Technical Overview. Introduction. When Should I Lock My Methods?

2-1. the ESI Probe Assembly. the PEEK Safety Sleeve and Sample Tube to the ESI Probe

TraceFinder Analysis Quick Reference Guide

Customer Information. Service Engineer s Responsibilities. Additional Instruction Notes. Agilent 6230B Series TOF LC-MS System Installation Checklist

Data Collection Software Release Notes. Real-Time PCR Analysis Software Release Notes. SNP Genotyping Analysis Software Release Notes

Agilent Instrument Control Framework A for Agilent LC/CE and GC Instruments in Non-Agilent Chromatography Data Systems Release Notes

Quick Start Guide v1.0

Warning 101 Invalid heater power for front detector, inlet, and aux 1 Warning 102 Invalid heater power for back detector, inlet, and aux 2

irc Pro (Not for diagnostic use)

Agilent G3250AA LC/MSD TOF System

Quick Guide to the Star Bar

Data Acquisition with 3800 GC Control

Agilent 7890GC. Firmware Bulletin. Revision B and A External use only

ChromQuest 5.0 Quick Reference Guide

SIM Direct Inlet Probe. Agilent 5975 MSD. Agilent 7000 Triple Quadrupole

Agilent MassHunter Drug Analysis Mode Using Quantitative Analysis Workflow Guide

Maxum Workstation Update Release Notes

Agilent Triple Quadrupole LC/MS Peptide Quantitation with Skyline

Data Acquisition with 3400/3600 GC Control

Agilent G1701DA MSD ChemStation

xponent Version 4.2 RELEASE NOTES

SOFTWARE UPDATE NOTIFICATION (SUN) OMNISEC SOFTWARE v10.30: PSS

Agilent G1732AA MSD Security ChemStation

Customer Information. Service Engineer s Responsibilities. Additional Instruction Notes. System Information. Agilent Technologies

Waters 2707 Autosampler ICS v1.20 Installer

MassLynx 4.2 SCN 989 Release Notes

Agilent G6854AA MassHunter Personal Pesticide Database Kit Quick Start Guide

LxT Version October LxT Version December LxT Version January 2014

HITACHI LACHROM ELITE

Agilent OpenLAB CDS. Version 2.2. Release Notes. OpenLAB CDS Release Notes 1

ABI PRISM 3100-Avant and 3100 Data Collection v2.0 Software Frequently Asked Questions (FAQ)

cief Data Analysis Chapter Overview Chapter 12:

RIVA / Athena Pro-Series ECU

Agilent MassHunter Qualitative Data Analysis

Bruker OminiFlex MALDI-TOF Mass Spectrometer Operation Quick Start

DataView Release Notes Version

DataView Release Notes Version Released

Hardware Overview. AB SCIEX TripleTOF 5600 System

SI-150-GIST. DART Thermo Quantiva, Endura, and Fusion VAPUR Interface User Manual. IonSense Inc. 999 Broadway Suite 404 Saugus, MA 01906

EZChrom Elite Compact. What s New in EZChrom Elite Compact Service Pack 2

Customers should provide all necessary operating supplies upon request of the engineer.

Release Notes. Analyst TF Software

ACQUITY UPLC Systems with 2D Technology Capabilities Guide

Agilent OpenLAB CDS Waters Alliance HPLC Instrument Control Add-On. Installation, Upgrade and Migration Guide

Product Release Notes

Safety Instructions 1-1 Avoid unintended Start General Description 2-2

Release Notes Life Technologies Attune NxT Software v2.3

Chromeleon-PA Analyzer User s Guide Dionex Corporation

NEW FEATURES IN CHEMCAD VERSION 6: VERSION RELEASE NOTES. CHEMCAD New Features and Enhancements. CHEMCAD Maintenance

Copyright ANRITSU. All rights reserved.

Agilent G6855AA MassHunter Personal

Product Correction Urgent Immediate Action Required

Using SIMDIS Expert 9 (Separation Systems) with Clarity

Agilent G1978A Multimode Source for 6300 Series Ion Trap LC/MS

Analyst QS. Administrator s Guide. Part Number: B July 2004

Agilent G1978A Multimode Source for G1946/G1956 LC/MSD

Agilent 1200 Infinity Series High Dynamic Range Diode Array Detector Solution

Multivariate Calibration Quick Guide

TA Instruments New Features in ITCRun TM Software

Chromeleon / MSQ Plus Operator s Guide Document No Revision 03 October 2009

Agilent MassHunter GCMS Data Acquisition for the 5977 Series MSD System

How to Run the CASPiE GCMS

Quick Reference. 5973N and 5973 inert Mass Selective Detector Local Control Panel (LCP)

Standard Operating Procedure for the HPLC-ICP-MS System By Celina Dozier Fall 2017

Agilent G1978A Multimode for 6210/6220 TOF

Addendum to S.U.N. for version 3.00

Customer ( you ) must review these notes prior to installing or operating the Attune NxT Software version ( Attune Software v1.1.0 ).

Waters ACQUITY QDa Instrument Component Software version 1.54

Manual HPLC-4 Alliance-UV

Model FP-6500 Spectrofluorometer Instruction Manual. FP-6500 for Windows

Agilent 7890 GC Instrument Control Software Version 2.5

Agilent GC, MS, and ALS

Technical Procedure for Inductively Coupled Plasma Mass Spectrometry (ICP-MS) for Gunshot Residue Analysis

Jasco 4700 FTIR. Laser Spectroscopy Labs. Jasco 4700 FTIR. Operation instructions. Laser Spectroscopy Labs, UCI

Transcription:

NOTICE: This document contains references to Varian. Please note that Varian, Inc. is now part of Agilent Technologies. For more information, go to www.agilent.com/chem.

Varian MS Workstation 6.9 Service Pack #2 The software contained in this kit is an add-on to the Varian MS Workstation 6.9 SP1 software (P/N 03-914982-01:17), containing a number of improvements and corrections. Installing the MS Workstation 6.9 Service Pack #2 Software Verify that Version 6.9 of the MS Workstation is installed on your computer. You can do this by selecting About... under Help in the menu bar of any of the MS Workstation applications and checking the version number, or right-click on an open area of the MS Workstation Toolbar, select About Workstation Toolbar and check the displayed version number. If Service Pack 1 is not displayed under Version 6.9.0, you must install MS Workstation Version 6.9 with SP1 before you can install this Update. If MS Workstation Version 6.9 SP1 is already installed, you may install the SP2 Update by downloading it from http://www.varianinc.com/support/downloads/ and launching MSWS690SP2.EXE. 2000 MS, 4000 MS, 500-MS No changes MS Data Handling/Reports 6359 6366 6393 Manual integration sometimes updates calibration replicates incorrectly MS Workstation Platform MS DataRev Quan, Review Results When manual integration changes a compound result from Missing to Identified or from Identified to Missing, the calibration data point replicates sometimes can be updated incorrectly. If the modified calibration point was an Internal Standard, the relative response factors in the data file for all of the compounds that are calibrated with it will be updated incorrectly. Ion Time shown for Quad files! MS Workstation Platform MS DataRev - General When Quad spectra are displayed, N/A should be displayed for Ion Time values in spectrum Plot Titles. Long Sample ID name can crash Method Builder in Print Preview MS Workstation Platform DHMeth MS Standard MS Reports Method Builder can crash when Print Preview is selected if Sample ID is selected as the Sort By key in the Standard MS Reports Summary Report Format dialog, and the Sample ID string is very long. Page 1

Core Workstation Platform 5927 6386 6400 Inject Single Sample makes two injections (& repeated sample list) Core Workstation Platform Under some conditions, a sample list or single sample injection ran twice without any operator action. A potential cause of this problem was corrected 212-LC: Method Printout broken 212-LC Method Editor - Printing Method printouts for the 212-LC did not show composition or flow. Run Log printing/formatting was fine. The problem was corrected in the 212-LC driver. CPAL: Automix "Aspirate" command does not work CombiPAL AutoSampler The AutoMix "Aspirate" command moves the head to the specify vial, but the needle does not go in the vial. The command was corrected to use the penetration specified in the method. Quadrupole MS (/1200/1200L) 6387 1200 APCI Corona current resets on some Breakdown curves When running the API Capillary Breakdown in APCI mode in positive mode, the corona current resets itself to 2.0 when the breakdown starts. 6360 6361 6364 Scan parameters changed during acquisition will not take effect if probe is running ModWin - Acquistion When performing an acquisition with the probe running and the Scan Parameters (such as mass window) are changed, the message "Would you like to Install the new method into the scan?" is displayed. Clicking on Apply should cause the new parameters to be applied but they are not. If the probe program is not active and the same changes are made, the acquisition is updated correctly. Open Current Error if running Probe with automatic adjust to signal strength If the Probe is running in feedback mode (aka Changes temperature ramp to reach target ion signal strength), an "Open Current Error" occurs shortly after initiating the program with a starting current of 10. Exposure Probe maximum current is wrong Page 2

6364 When typing a number greater than 450 into the current program (or constant current) for an Exposure Probe method and clicking on Apply, the value is automatically changed to 450. The Exposure Probe max current should be 1500mA. 6365 6391 6402 6407 6443 6457 6477 If using all masses in Probe feedback mode evaluates incorrect mass range If the Intensity of ions scanned Ion signal type is selected in Probe feedback mode (Changes temperature ramp to reach target ion signal strength), an incorrect mass range is evaluated. Probe Status in Instrument Status screen gets truncated If there are more than 2 numerical digits for the probe current/temperature, the text box in the instrument status screen gets cut off, so that the values are not visible. Low end limiting of the RF is too restrictive When scanning from mass 10, some systems will sometimes exhibit a ghost peak as a result of variances in Mass Calibration. There is no 'EFC/EPC Check' Log It would be desirable to have an 'EFC/EPC Check' Log that would document the steps taken. Inlet interlock cable disconnected should behave as open cap When the Inlet interlock cable is disconnected, it should disable the filament, detector, and quad voltages as it does when the spray chamber is open. Instrument status says 'Calibrating Methane' when it s actually Flushing. When the system is switched from EI to CI the status says 'Calibrating Methane' instead of 'Flushing'. Air/Water Check runs even when masses 18 & 28 are not tuned. Currently, when the system is Autotuned with masses 18 & 28 unchecked and the 'Air Water' check is run, although the system is unable to adjust Page 3

6334 6344 6385 6388 6403 6404 resolution on these masses, the check still completes and gives a report. The user should be warned to Tune the system at 18 & 28 before running the test. System Control Crash/Blue Screen of Death when syntax error occurs in Advanced Options PML command line In the Advanced Options window of the Scan Table (in Manual Control), if a PML with incorrect syntax is entered, there is an error message displayed, but System Control hangs without allowing the error to be resolved. EDR Calibration Error ModWin Auto Tune The EDR calibration error currently tells the user that the calibration was aborted: "Curve - ion signal too large". There should be an additional comment telling the user to try the calibration again after 1-7 days if a new multiplier was just installed. Acquisition hangs on Waiting for Injection When running a Sample List without an autosampler, after a number of injections, the acquisition/automation will get stuck on Waiting for Injection. If automation is suspended and restarted, it will start again, but will eventually happen again. RunLog and Detector Overrides Currently, the detector behaves in such a way that if there is an override in one segment, the detector does not revert back to the original global value when it goes to the next segment and that segment has no override checked. The RunLog shows the detector reverting back to the global value, while System Control shows the overriden value in a segment where the value is not overridden. The runlog should match what the detector actually does during the run. Manifold heater should be shut off if fuse F3 is blown Currently the software maintains power to the manifold heater as long as the line voltage is not greater than 140V. However, if the instrument is set up for 220V operation and fuse F3 is blown or missing the line voltage will continue to be powered but the current to it will be doubled. Q1ms and Q3ms switching isn t always immediately reflected in the status After typing Q1ms in the command line and then switching to Q3ms, Page 4

6406 6426 6431 6432 6454 although scanning does change as it should to Q3ms, the status screen reflecting this isn t always updated until some other action is taken in the system. Need to clarify Air/Water Check Criteria The AutoTune process currently reports the following conditions if they are detected: "Mass 18 is at least as large as Mass 69" "Mass 28 is at least as large as Mass 69" However, this situation does not necessarily imply a leak and we should eliminate these messages to stop leading users to this invalid conclusion. On the other hand, we need to encourage regular use of the Air/Water check to explicitly check for leaks. To that end: 1) Eliminate the above checks and messages from the Auto Tune process - They should not affect the results. 2) Unconditionally and automatically run the Air/Water Check at the end of each Auto Tune [Tune and Calibrate, Calibrate] when operating in EI mode. CID Pressure Calibration ModWin - Diagnostics Change the way that CID and source pressure calibration results are reported. If there is too much noise or pressure drift, report the resulting error with a message like "Warning!, CID calibration is only within 1.2mTorr" If there is no pressure or any other error not allowing the creation of a calibration curve, report the following: "CID calibration failed, no new calibration was generated" or "CID calibration failed, default calibration table was installed" Uninitialized EEPROM on new power PCB should be initialized When a new Power PCB is installed in a Quad the EEPROM on it has not yet been initialized. If there is a valid config.cub on the system then the EEPROM should be initialized automatically. Correcting this should resolve spurious Model Definition errors. Analyzer Connections test questionable Eliminate the dirt test from the Analyzer Connections test. EDR Calibration Problems ModWin Auto Tune Periodically, especially with new detectors, there are discontinuities in the EDR calibration due to the broad range of voltages included in the curve. Limiting the curve to the range of calibrated values eliminates the problem. Page 5

6478 Autotune vs. Report Only flags are inconsistent ModWin Auto Tune The Autotune report will flag ions that were not used in the tune as report only, not tuned. However, if a report is generated without re-tuning the instrument, the tune report shows warning flags for mass shifting and peak resolution on these unused ions. These flags should match the Autotune report so as not to confuse and unduly concern the user. 6489 Mass shift on Q1 System Control (General) When doing Full Scan: If the collision cell energy listed in the Scan Table is 0.00, rather than a blank cell, the masses are shifted on Q1 (M-1), but OK on Q3. In Full Scan, if 0.00 is the collision cell energy, it should behave the same as if there was no energy entered. Note: The following change to the Tune Report was implemented in MSWS 6.90 for Quadrupole MS systems: If a problem is encountered with a mass that is specified to be included in the report but not tuned, the message Reported only, not tuned will appear in the report under that particular mass. If the mass is reported only and no problem is encountered, no message will appear. Page 6