CRITICAL INFRASTRUCTURE ASSESSMENTS

Similar documents
VERTIV SERVICE CAPABILITY

VERTIV LIFE SERVICES. Remote Diagnostic and Preventive Monitoring

Liebert. APM from 30 to 300 kw. The Compact Row Based UPS With FlexPower Technology

SUPERSAVER. Energy Efficiency Optimization Software for Freecooling Systems

Liebert. EXS from 10 to 20 kw. Optimized and integrated three-phase UPS solution with high efficiency power protection

Liebert. NXC from 10 to 200 kw. Compact and Reliable Power in a Fully Integrated Packaged Solution

Data Center Assessment Helps Keep Critical Equipment Operational. A White Paper from the Experts in Business-Critical Continuity TM

POWER CONTINUITY IN HEALTHCARE: SIZING AND CONFIGURING POWER SYSTEMS FOR RELIABILITY AND COST-EFFECTIVENESS

SMARTAISLE Intelligent, Integrated Infrastructure for the Data Center

Liebert. AFC from 500 to 1700 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

FREECOOLING, EVAPORATIVE AND ADIABATIC COOLING TECHNOLOGIES IN DATA CENTER. Applications in Diverse Climates within Europe, Middle East and Africa

Liebert. PDX from 15 to 165 kw. Direct Expansion Solution for Small and Medium Data Centers

Liebert APM from kw. The Compact Row-Based UPS With FlexPower Technology TM

Liebert NXC. 10 to 40kVA Compact and Reliable Power in a Fully Integrated Packaged Solution

DATA CENTER SERVICES. A Higher Level of Service Expertise

SMARTMOD Intelligent, Integrated Infrastructure for the Data Center

2016 COOLING THE EDGE SURVEY. Conducted by Vertiv Publication Date: August 30, 2016

PLAYBOOK. How Do You Plan to Grow? Evaluating Your Critical Infrastructure Can Help Uncover the Right Strategy

APMTM UPS 18kW - 90kW The Flexpower Technology for mission critical applications

Liebert. AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability CERTIFIED HVAC-HYGIENE.

PEX+ High Efficiency, Low Operating Cost Precision Solution for Data Centers

Liebert. DCL up to 35 kw. Modular Rack Cooling

Liebert PDX. The Cooling Solution for Small and Medium Data Centers. Digital Scroll. Part Load. Competent Partner Efficiency

Liebert. EFC from 100 to 350 kw. The Highly Efficient Indirect Evaporative Freecooling Unit

DISTRIBUTED AND CENTRALIZED BYPASS ARCHITECTURES COMPARED

Liebert. DCL up to 35 kw. Modular Rack Cooling

1.0 Executive Summary. 2.0 Available Features & Benefits

PEX (R410A) High Efficiency, Green Solution Precision Cooling for Data Centers

Liebert. PCW from 25 to 220 kw. Chilled Water Units Optimizing Data Center Efficiency

SMART SOLUTIONS TM INTELLIGENT, INTEGRATED INFRASTRUCTURE FOR THE DATA CENTER

Liebert DCW CATALOGUE

SmartMod Intelligent, Integrated Infrastructure for the Data Center

Liebert. icom Thermal System Controls Greater Data Center Protection, Efficiency & Insight

ARE YOUR RACK PDUS KEEPING YOU FROM OPTIMIZING POWER MANAGEMENT?

Liebert NXC from 10 to 200 kva

Powering Change in the Data Center. A White Paper from the Experts in Business-Critical Continuity TM

exm UPS 80kW - 200kW Efficient, Flexible Power Optimized For Medium Size UPS Applications

Survey and Audit Service Schedule. Airflow and Thermal Imaging Survey Service Schedule. Data Centre Solutions Expertly Engineered

SmartCabinet Intelligent, Integrated Containment for IT Infrastructure

ITA2 UPS 5-20kVA Compact, Efficient & Robust UPS For Critical Applications

ITA2 UPS 5-20kVA Compact, Efficient & Robust UPS For Critical Applications

Rack & Enclosure Systems

Liebert EXL TM S kw to 1200 kw. Enhanced Design and Improved Efficiency

Liebert. EXL S1 from 100 to 1200 kw. Enhanced Design and Improved Efficiency

APMTM UPS 30kW - 300kW The Compact Row-Based UPS With Flexpower Technology

Liebert 80-eXL from 100 to 1200 kw. Enhanced Design and Improved Efficiency

SmartAisle Intelligent, Integrated Infrastructure Using Row-based Building Blocks. Solutions For Business-Critical Continuity

DATA CENTER TRANSFORMATION: THE IMPACT OF EMERGING POWER ARCHITECTURES ON TODAY S DATA CENTERS

Liebert. HPC-S Free Cooling Chiller Designed for the Efficient Cooling of Small Data Centers

APPLYING DATA CENTER INFRASTRUCTURE MANAGEMENT IN COLOCATION DATA CENTERS

Liebert PDX from 15 to 120 kw

System architecture. Datacenter Clarity LC provides flexible client-server architectures configured to meet the needs of each organization,

DATA CENTER PRECISION COOLING: The Need For A Higher Level Of Service Expertise

Liebert NXC. 10 to 40kVA Compact and Reliable Power in a Fully Integrated Packaged Solution

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

1.1 ANNUAL DATA CENTER HEALTH CHECK

Trinergy from 200 to 1600 kw. High Power Modular Scalable UPS With Three Dynamic Functioning Modes

Liebert PDX from 15 to 120 kw

INNOVATE FASTER COMPETING FOR THE IT WORKLOAD BUSINESS. Hosted Cloud, Managed Service Providers & Colocation Data Centers

Hipulse-U UPS 80kVA - 500kVA Utmost Reliable Power Solution for Critical Business Applications

1.0 Executive Summary

Liebert HPC. Freecooling Scroll Chillers for the Efficient Cooling of Data Centers

Trellis Real-Time Infrastructure Optimization Platform Release Notes

UPS PRO MODERNÍ DATOVÁ CENTRA. Rastislav Smatana AC Power Sales Manager CZ&SK

Liebert : The Right Cooling For IT Environments

5 STEPS for Turning Data into Actionable Insights

Liebert 80-eXL from 160 to 500 kw. Enhanced Design and Improved Efficiency

SmartRow Intelligent, Integrated Infrastructure in a Self-Contained Line-Up. Solutions For Business-Critical Continuity

TECHNOLOGY: THE COMPETITIVE ADVANTAGE FOR SUCCESSFUL RETAIL BUSINESS

18 th National Award for Excellence in Energy Management. July 27, 2017

SmartRow Solution Intelligent, Integrated Infrastructure for the Data Center

Schneider Electric Critical Power & Cooling Services. Services to keep your mission-critical applications operating at optimal performance

ADDRESSING CHALLENGES TO POWERING SMALL TO MIDSIZE IT SPACES

System architecture. Datacenter Clarity LC provides flexible client-server architectures configured to meet the needs of each organization,

Achieving Optimal Returns from Wellhead Operations

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Liebert APM The Compact Row-Based UPS With Flexpower Technology TM 30kW - 300kW. AC Power For Business-Critical Continuity

Media Pack. ENERGY EFFICIENCY BRITISH MANUFACTURER TRAINING

Executive Summary. Zuma Engineering and Research. Data Center Virtualization Assessment. Service Description

Smart Data Centres. Robert M Pe, Data Centre Consultant HP Services SEA

Liebert APM UPS The Industry s Highest Energy Efficiency In A Row-Based, On-line UPS. AC Power For Business-Critical Continuity

Liebert XDA Air Flow Enhancer. User Manual

Liebert NXC from 10 to 60kVA

Liebert exm UPS kva/kw Efficient, Flexible Power Optimized for Midsize Applications FLEXIBLE. ECONOMICAL. INTELLIGENT

Precision Cooling. Precision Cooling Advantages

Liebert. EXL UPS 800 and 1200kVA Single Module and Multi-Module Systems

Liebert exm TM. 80kW - 200kW Efficient, Flexible Power Optimized For Medium Size UPS Applications

UPS. centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw INFINITE POWER. Mission Critical Applications

Power Management Solutions Maximise the reliability and efficiency of your power critical facility

Liebert DCW Family Chilled Water-Based High Density Cooling For The Data Center. Precision Cooling For Business-Critical Continuity

02 Why Does My IT Infrastructure Need a UPS?

Google s Green Data Centers: Network POP Case Study

Liebert. GXT3 5kVA-10kVA Compact UPS Systems For High Power Network Rack Applications

THE INSIDE-OUT APPROACH. Enabling an Open, Scalable Data Center IoT

TWO FINANCIAL IMPACT STUDIES. Seal IT Equipment Cabinets for Significant Annual Cost Savings and Simple Payback in a Few Short Months

Highly Efficient Power Protection for High Density Computing Applications

CHANGING THE WAY COMPANIES RUN. The Aperture Suite

Rockwell Automation ODVA Annual Meeting

Overcoming the Challenges of Server Virtualisation

Two-Stage Power Distribution: An Essential Strategy to Future Proof the Data Center

Transcription:

CRITICAL INFRASTRUCTURE ASSESSMENTS

CRITICAL INFRASTRUCTURE ASSESSMENTS Critical Infrastructure Assessments Professional insight delivered by Vertiv experts will ensure that your infrastructure performs at its best today and into the future. Vertiv supports entire critical infrastructures with an extensive service offering, enhancing network availability and ensuring total peace of mind 24/7. With the broadest, most comprehensive service presence in the industry and more than 600 Customer Engineers dedicated to servicing Europe, Middle East and Africa, Vertiv ensures that your business is protected 100% of the time and that assistance is close by whenever needed. Vertiv Customer Engineers are experienced professionals who regular undergo intensive training programs and are certified according to country specific, European and international regulations and standards. Vertiv s professional Critical Infrastructure Assessments are designed to provide facility managers with insight into the performance of their infrastructure. The assessments furthermore assist in identifying areas of optimization in availability and efficiency. In doing so, industry best practice parameters are used to measure and evaluate data center operation and performance. The assessments specifically evaluate the extent to which cooling and power architecture is leveraged, the level of redundancy, as well as the efficiency of the installed systems, presence of hot spots, the use of floor space and air distribution versus heat dissipation. The assessments focus on: Maximizing efficiency and uptime in data centers and telecom sites Optimizing the utilization of power and cooling infrastructure Analyzing the efficiency of heat removal generated by IT and telecom equipment Identifying hot spots and potential risks Assessing the capacity of electrical systems Identifying electrical risks with the potential of leading to downtime. Utilizing industry-leading assessment tools to deliver superior analysis allows our expert Customer Engineers to verify that equipment is correctly dimensioned for the current demands. It also enables them to provide advice on how and where the critical infrastructure can be strengthened to meet future demands. The comprehensive assessment report details recommendations for optimizing the performance, capacity, availability and efficiency of both cooling and power equipment. Assessment reports are backed up by Computational Fluid Dynamics (CFD) modeling and financial return on investment (ROI) calculations. Critical infrastructure assessments include: Optimization and expansion strategies On-site power and cooling assessment Power Usage Effectiveness (PUE) analysis Computational Fluid Dynamics (CFD) modeling Documentation of findings and recommendations Consultation and review of report findings Contingency plan IT Capacity strategy Thermocamera Scan. 2

Audit Vertiv s Critical Infrastructure Audit provides a qualitative snapshot of the infrastructure s overall health, evaluating its operation based on industry benchmarks. Providing insight into the current status of the infrastructure operation, the audit also serves as a means of evaluating if a more in depth analysis, such as a Critical Infrastructure Assessment or specific Power or Thermal Management Assessment is warranted. Expert Customer Engineers carry out site visits to validate the health status of the data center using results from Infrared Cameras to determine the current viability of the facility, as well as identify steps for greater flexibility, reliability and total cost of ownership (TCO) optimization. The remote data collection and analysis relates to the overall facility, as well as more specifically to: Power and Cooling Racks and Cabling Monitoring Systems Service Practices. The result is a report of the overall analysis and recommendations for optimized site operation, capacity utilization, efficiency and availability providing evidence of: Overall performance compared to industry benchmarks Current risk cost/benefit analysis Recommended action plan. 3

CRITICAL INFRASTRUCTURE ASSESSMENTS Thermal Management Assessments Specific Thermal Management Assessments enhance IT system availability by identifying and eliminating hot spots, as well as providing vital recommendations for maximizing the performance and efficiency of cooling infrastructure, in addition to system expansion and optimization. This is achieved by carrying out an investigative on-site analysis measuring the effectiveness of the data center or telecom site s critical equipment cooling methods. The assessment is furthermore designed to identify airflow issues in existing room conditions and practices, accomplished through Computational Fluid Dynamics (CFD) modeling which illustrates the data center s thermal condition and airflow patterns. Temperature ( C) 38 31 24 17 10 Computational Fluid Dynamics (CFD) modeling visually depicts the heat-related impact on data center facilities by simulating the outcome following the implementation of recommendations. 4

Vertiv comprehensive Thermal Management Assessments feature: Air Temperature measurement Air Flow measurement Identification of hot spots through tools such as thermo cameras and Computational Fluid Dynamics (CFD) modeling Comparison of IT /Telecom equipment load with cooling unit capacity Computational Fluid Dynamics (CFD) modeling. Temperature ( C) 38 31 24 17 10 5

CRITICAL INFRASTRUCTURE ASSESSMENTS Critical Power Assessment A dedicated Power Assessment will determine the power equipment performance, as well as identify energy saving opportunities at site, ensuring overall infrastructure availability. Using industry-leading tools, Vertiv s expert Customer Engineers assess the electrical infrastructure from the incoming power through to the critical load, with the objective of recommending actions for improving power-related performance, energy and other operating cost-savings while ensuring compliance with industry best practices and safety codes and standards. As with Vertiv s wider series of assessments, industry benchmarks and best practices are used as parameters for evaluation. Vertiv comprehensive power assessments feature: Power Usage Effectiveness (PUE) analysis Single point of failure analysis Switchgear equipment analysis DC systems analysis including rated capacity, utilization and efficiency on rectifiers and inverters UPS systems analysis including rated capacity, utilization and efficiency Battery backup and battery optimization Critical components thermal analysis. Reporting is a fundamental component of the Power Assessment in which the in depth evaluation of parameters measured, together with optimization recommendations and return on investment (ROI) calculations are detailed. It is moreover designed to provide data center professionals with clear recommendations and actions for immediate and future optimization of power infrastructure. 6

7

VertivCo.com Vertiv Infrastructure Limited, George Curl Way, Southampton, SO18 2RY, VAT Number: GB188146827 2016 Vertiv Co. All rights reserved. Vertiv, the Vertiv logo, Liebert Trinergy Cube, Liebert 80-eXL 800 kw, Liebert NXL 800 kva, Liebert CROSS and Vertiv LIFE Services are trademarks or registered trademarks of Vertiv Co. All other names and logos referred to are trade names, trademarks or registered trademarks of their respective owners. While every precaution has been taken to ensure accuracy and completeness herein, Vertiv Co. assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications are subject to change without notice. MKA4L0UKDCA Rev.2-04/2014