NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02

Similar documents
~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function

Automation stations compact model

RXB10.1. Room controller. Siemens Building Technologies Building Automation DESIGO RXB. for chilled ceilings and radiators with EIB bus communication

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

PXR11 PXR12. System controllers DESIGO PX

Room unit with PPS2 interface

DESIGO 30 Remote operator terminal. for more then one HVAC systems en. menu + esc

Non-communicating room controllers

Temperature controller Ducted systems

Product and functional description

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

MXPLC. Compact PLC process station. Summary. Application HVAC control systems, data acquisition, interfacing 3 rd party systems.

Power supply module, bus connection module

RXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

Room Temperature Controllers

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13

Product and functional description

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

EY-EM : Remote I/O module, ecolink

Operating instructions. Switching amplifier DN0210 DN / / 2015

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

MINI-PS AC/10-15DC/8

Overview of types. Technical data

Room automation station

QAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC

IMIO100 IMIO105. DDC controllers. Summary

Expansion Module HZS 541-1S

2001VT Temp & CO 2. - air quality sensor/controller NOTE!!! Manual for Installation. General. SenseAir AB

Operating instructions. Standstill monitor A / / 2011

Super universal modules

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

584 5WG AB_1 DELTA

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

Product and functional description

Electrical Actuators

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

9.5 nominal torque 4.5 W 16 VA. Min. 30 nominal voltage Min. 30 Nm. Reversible with switch By mounting. MIN (minimum position)

FCU-MULTI Modbus Fan Coil Unit Controller

Electrical Actuators

Communicative controller for VAV systems

Installation manual CF8-W-Disp-AL

Operating instructions. Speed monitor D / / 2014

Operating Instructions VEGAMET 381

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

Extension module for lighting control

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

MC 11 EB-2 Power supply cabinet with external bus, AC version

RT4F-120V/20A-WAC RECTIFIER

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Product and functional description

Electrical Actuators

is then retained absolutely without interruption.

mark150s mark150/485s DDC controllers Summary

HWS Series Wall Mount with Relay Setpoints, LCD, and Humidistat Control

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

EXOcompact. Third generation freely programmable controllers

Compact Universal Controllers

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

AIAS. Technical description

Room unit with PPS2 interface

RT4B-110V/12A RECTIFIER

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Room unit with PPS2 interface

Products no longer available

Product and functional description

Contents. Introduction / Description of operation. Alphabetical index of products Introduction Brief system description

MINI MCR-SL-UI-REL(-SP)

EY-IO 534: I/O module, analogue inputs with galvanic isolation, modu534

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

16-Channel Digital Input Termination Card 24Vdc

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

QUINT-BUFFER/24DC/24DC/40

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

Operating and mounting instructions

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

PTC/PT100 board 2.0 Option

I/O module, analogue outputs and universal inputs

Small distributed I/O module

Use. Functions. OpenAir TM. Linear version, modulating, AC 24 V

AC-DC Converter REC K10

STEP-PS/1AC/24DC/1.75

RTU560 Connections and Settings DIN Rail RTU 560CIG10

MVS RAIL ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

Non-communicating room controllers

IQ21x Series Controllers

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Power Supply, Primary Switch Mode for Universal Use QUINT-PS AC/48DC/5

Electromotoric actuators

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

Transcription:

1/8 NRK16/A, NRK16-B/A, (NRK16-T /A, NRK14-T /A, NRK16-WEB/A) Control and interlock devices with pre-programmed system-specific application modules The controllers may be used as stand-alone control and interlock devices for remote process control within a management system Especially suitable for use in small heating, ventilation and air conditioning systems NRK16/A (with NSA) NRK16-B/A (with NSA) Electrical protection The power supply is overload-protected with a PTC thermal element All DC voltages are electrically isolated from the AC 24 V input All the inputs are protected against overvoltage (max AC/DC 45 V) Low-pass filters prevent fluctuations in measurement All outputs are sustained short-circuit proof High frequency interference is suppressed by means of filters, or in the case of capacitive interference, discharged via the (earthed) housing or the TE terminal (functional earth) Important: For direction connection of AC 24 V 3-wire peripheral devices, "GND" and "NS" (^) must be connected 1) The NMID multiplexer enables four digital inputs to be connected to a universal output (see K21-06 55) The function is integrated by use of a structure macro 2) When connecting peripheral devices with special input or output signals (e g Pt100, phase cut or 3-position signals), the NTIO (NTIOS) single module carrier or an NATU adapter can be used (See K21-06 50 and K21-06 52) 3) The T1/Ni1000 supply voltage can be disabled at the inputs (see page 5) DIP switches are provided to switch the inputs from T1 to Ni1000 and vice versa Types NRK16/A NRK16-B/A NSA NRK16-T /A NRK14-T /A NRK16-WEB/A Technical data Application controller with ten universal inputs 1) and two analogue, two digital and two combined outputs Like NRK16/A, but with panel for simple local operation Application modules, varying according to country or region, for plugging into base units NRK16/A + NITEL integrated communications module for a maximum of three additional devices (see manual NT21) Like NRK16-T /A, but without analogue outputs (see manual NT21) NRK16/A + integrated NIWEB communications module for operation of up to 15 additional devices via the Internet (K1-07 62) Supply voltage Nominal voltage Max tolerance +15 / 10 % Power consumption Without output peripherals 3 VA Extra low voltage (SELV-E) AC 24 V, 50/60 Hz With output peripherals Max 12 VA Fuse Thermal element (PTC) Supply voltage for peripheral devices and remote operator terminal Output voltage DC15V ±10%, electrically isolated from AC24V Output current Max 150 ma Signal inputs 2) Universal inputs 3) Number101) Use Can be structured as T1, Ni1000, DC 0 10 V, digital volt-free, or for connection of NMID Input impedance Ri (pull-up resistor) = 10 kw to DC +15 V or 100 kw to GND (change-over, see p 6) Remote control input Use Can be structured as T1, Ni1000, DC 0 10 V, min 1 5 sink, digital volt-free contacts, or NMID Input impedance Ri (pull-up resistor) = 10 kw to DC +15 V Signal outputs 2) Digital outputs Number2 Signal DC 0 / 24 V, 20 / +15 % Source current Max 50 ma Analogue outputs Number2 Range DC 0 10 V Source/sink current Max 2 ma Technical data continued on page 2

2/8 Battery In the event of a power failure, data is protected against loss by a replaceable lithium battery (service life approx 5 10 years) Used and faulty batteries must be disposed of in accordance with local regulations 4) Applies to permanently plugged-in application modules Technical data continued from page 1 Combined outputs Number2 Type One terminal with a digital and one with an analogue output (see data above) Digital/analogue relationship High > 50 %, low < 30 % of analogue signal Remote control output Range DC 0 10 V Source current Max 10 ma Sink current Max 3 ma Product data Accuracy Class 0 5 Sampling rate Internal 100 ms Structure 0 2 1 s Data protection after power failure Structures and parameters 4) > 10 years Time / date 4) Equivalent to battery life Adjustable values in NRK16-B/A 4) Equivalent to battery life NSA application module EEPROM Type 28C64 Connections Connection terminals Cable type and length Communication RS bus 2 5 mm2 screw terminals See installation instructions, K21-11 20 Electrically isolated from AC 24 V and signal outputs Transmission speed 9600 baud Max cable length (RS bus) 2400 m NRK16 /A connection to RS bus From service socket via 10-core ribbon cable to NARB/A adapter Service terminal Weight excluding packaging NRK16/A NRK16-B/A NSA application module Dimensions (W x H x D) NRK16 /A NSA application module Mounting NBRN operator terminal; plugs directly into service socket 1 15 kg 1 25 kg 0 06 kg 162 x 252 x 52 mm 24 x 59 x 49 mm Snap-mounted on DIN rails or screwed to a flat surface; NRK16-B/A installed in control panel front with the Z402 mounting kit Safety Product safety EN 61010-1 Contamination level 2 Electrical safety SELV-E (PELV to IEC 364-4-41) General ambient conditions Use Temperature range Operation 5 45 C Installed in control panel Storage 25 70 C Ambient humidity 10 90 %rh, non-condensing Conformity This product meets the requirements for marking and is tested

3/8 Note: SAPIM (Structure and Parameter Identification Menu) is a programming language developed by Landis & Staefa for the programming of control and interlock modules It consists of a wide range of basic functions (software modules) which can be combined to create all the structures required Brief description The RSA controllers are microprocessor-based DDC controllers comprising a base unit and a plug-in application module Each plug-in application module contains an EEPROM preprogrammed with a given application chosen from a wide range of heating, ventilation and air conditioning applications The application modules are held in application libraries in the various national and regional Staefa offices They can be selected according to the system and plugged into the base unit The engineering required is thus minimal, and since suitable default settings are provided for setpoints, parameters etc, commissioning is extremely easy If no suitable standard solution is available, a program for the specific application can be designed in SAPIM and downloaded to the module from a PC At the same time, the application modules are freely programmable, so that if no suitable standard solution is available, a program can be designed in SAPIM and downloaded to the module from a PC The EEPROM also holds the NBRN-modifiable setpoints, parameters and time programmes but not the setpoints from the local operator panel of the NRK16-B/A 92.00157 Construction Essentially, the base unit consists of a metal housing and printed circuit board The housing comprises a base and a cover, and accommodates the PCB and two-part plug-in connection terminals These terminals are accessible at the top and bottom of the housing, so that peripheral devices can be connected directly without removing the cover plate Additional terminals and a 10-pin ribbon cable connector are provided for the power supply, operator terminal and RS bus communication (see page 5, Connection diagram and suitable devices) The cover plate incorporates an aperture for the plug-in application module, a rotary switch for setting the RS bus address and three LEDs: Green (power): Power supply / basic test (on = OK) Yellow (Tx RS): Normal operation / RS bus communication (flashing = OK) Red (error) Error The NRK16-B/A incorporates additional elements for control and display (see page 8)

4/8 Mounting and dimensions [mm] The base unit can be fixed with four screws directly onto any surface, or snap-mounted on two rails If mounting rails are used, proceed as follows: 1 Fix the top rail 2 Fit the bottom rail to the base unit and snap-mount the unit onto the top rail 3 Fix the bottom rail The terminal connections are grouped in blocks, making for easy wiring without the need to remove the unit cover 149 92.00156 125 243 162 52 92.00158 252 203 Caution: The application module is a staticsensitive component Before inserting or removing the module, the base unit must be disconnected from the power supply Do not touch the contact pins in the base unit 15 59 49 24 Caution: Do not touch the PCB Electronic components can be damaged by electrostatic discharge Handling the PCB without observing electrostatic precautions will invalidate the warranty Opening the controller 1 Ensure that the necessary EMC precautions have been taken 2 Undo the four cross-head screws between the terminal blocks 3 Carefully lift off the cover For the NRK16-B/A: Press the four white plastic clips together with pliers, carefully release the pcb for the display and operating unit, and pull upwards Observe similar precautions when re-assembling the controller, paying special attention to the fibre optic cables of the LEDs and the extension of switch S100

5/8 Connection diagram and suitable peripheral devices T1/Ni1000 digital DC 0... 10 V NMID +15 GND Remote control 12 GND +15 A B C D E F G H I J + + 4 6 K 92.00160en UO01 UO02 UO03 UO04 UO05 UO06 UI01 UI02 UI03 UI04 UI05 UI06 UI07 UI08 UI09 UI10 UI11 UO07 SAPIM I/O number SAPIM I/O number Notes: 1 The digital outputs (C, D, E and F) are active-type outputs, DC 0 or 24 V (max 50 ma) 2 Outputs C and D may be used as both digital and analogue outputs The digital (24 V) signal switchs on when the analogue output is > 5 V, and off when it is < 3 V 3 Other input and output types may be connected via the NTIO adapter and suitable input or output modules Service NBRN (RS485) A B C D E 3 4 AC 24 V 3 4 3-4 5 3 4 5 + + + 3 - Suitable peripheral devices (examples) Documentation T1/Ni1000 Sensors with T1 or Ni1000 measuring elements Various ZM100/A Teminal housing for DC 0 10 V valves CA2N4591 NTIO Single terminal module carrier K21-06 50 NATU Adapter for special signals K21-06 52 NMID Multiplexer (to increase the number of digital inputs) K21-06 55 Room operating units, see page 7 F 5 3 5 + 3 = COMMON 4 = DC 0... 10 V 5 = digital (DC 0 / 24 V) 3 4 ZM100 3 4 3 5 Relay, 24 VDC AC DC 24 V 15 V L TE (+) N (-) L N S S GND +15

6/8 Selection of T1 or Ni1000 sensor Both T1 and Ni1000 sensors can be connected to the RSA application controllers DIP switch S182 is used to adapt the controller to the required sensor type External access to this DIP switch is possible after removal of the NSA plug-in application module The change-over from one sensor type to the other is applied in blocks of eight and three inputs (UI01 UI08 and UI09 UI11 respectively) 00414 Rotary address switch Firmware D120 Battery T1/Ni1000 switch Application Slot for NSA module S182 D140 ON ON OFF 1) When setting the input parameters in INTEGRAL PLAN, note that the T1 input range should be used for Ni1000 sensors The controller is adapted to the sensor via the hardware only The SAPIM software is not affected Settings for switch S182 T1/Ni1000 Sensor Inputs OFF T1 UI01 to UI08 OFF T1 UI09 to UI16 ON Ni1000 1) UI01 to UI08 ON Ni1000 1) UI09 to UI16 The factory setting is T1 Inputs and jumpers Input JumperInput Jumper A UI01 X310 F UI06 X360 B UI02 X320 G UI07 X370 C UI03 X330 H UI08 X380 D UI04 X340 I UI09 X410 E UI05 X350 J UI10 X420 Disabling the sensor supply voltage The pull-up resistors (Ri = 10kW) for the T1 and Ni1000 sensor supply voltage can be disabled individually at inputs A (UI101) to J (UI10) with jumpers X310 to X420 This process is required whenever devices are connected which are unable to sink current The jumpers are located on the printed circuit board and cannot be adjusted without opening the controller housing When delivered from the factory, the jumper settings are such that the sensor supply voltage is enabled To disable the supply, each jumper must be moved one position to the left 51068A UI01... UI05 X301 UI06... UI10 X302 Caution The incorrect positioning of jumpers can give rise to offset voltages when active signal transmitters are connected (failure to reach a zero-point) X310 X320 X330 X340 X350 View of part of the PCB: In this example, apart from X350 and X360 (T1/Ni1000 supply OFF) all the jumpers are shown in their factory-set position X360 X370 X380 X410 X420

7/8 Operation and service The controller can be operated by various means: Remotely, from a room operating unit Via the RS bus, with an operator terminal or PC NBRN- operator terminal or service PC for service and commissioning NRK16-B/A for simple local operation (see page 8) NRK16-WEB/A for operation with an Internet browser Important: For communication on the RS bus, the controller must be assigned the appropriate address, by use of the rotary switch on the cover plate (Factory-setting: Address 1) Remote operation Connection terminals K1, K2, K4 and K6 are provided for remote operation from a type KR room operating unit The PB operating units should be connected to universal inputs A J Suitable room operating units Documentation KRT-1B Room temperature measurement Room temperature setpoint adjustment Mode selection (AUT, ON or OFF) Heating time extension (by 1, 2 or 4 hours) CA2N1612 KRT-1L Room temperature measurement Room temperature setpoint adjustment Mode selection (AUT, ON or OFF) Holiday mode extension (by 1, 2 or 3 days) CA2N1613 KRU-1 Room temperature measurement Mode selection (AUT, ON or OFF) Timer module with independent time function CA2N1614 PBA Room temperature measurement Room temperature setpoint adjustment CA2N1651 P B C Room temperature measurement Room temperature setpoint adjustment Digital display of room temperature CA2N1655 See the relevant documentation for maximum cable lengths Operation via RS bus Since the controller is compatible with the RS bus, it can be operated remotely from any of the following devices: NBE remote operator terminal (see K21-05 18) NBRN- operator terminal (see K21-05 10 and 12) From a PC running the INTEGRAL DIALOG service software, connected via the NITEL communications module (see K21-07 30) or NARC RS485-RS232 adapter Internet browser, via the NIWEB communications module Where the INTEGRAL RS system is integrated into a higher-level system, the controllers can also be operated as follows: In an INTEGRAL MS1000, MS2000 or TS1500 building management system In the DESIGO INSIGHT building management system, with advanced graphics-based operation Service and commissioning For service and commissioning purposes an NBRN- terminal or a PC can be connected directly to the service socket on the controller The same socket is used to download an application-specific SAPIM program from a suitable PC (not required for pre-programmed modules) User manuals The following user manuals are available for the operator software described above: K23 NBRN operator terminals K9 INTEGRAL DIALOG CA12U3290 NIWEB User manual CA1B9110 DESIGO INSIGHT

8/8 Simple local operation with the NRK16-B/A The cover plate of the NRK16-B/A incorporates facilities for direct operation The functions of the selectable display and switches are defined by the application module selected 1 2 3 92.00159 5 4 1 Rocker switches 2 Four-digit 7-segment LED display 3 Display-selector keys, from top: Measured value 1 Measured value 2 Setpoint 1 Setpoint 2 4 Channel LEDs corresponding to selector keys 5 <+> and < > for setpoint entry Each rocker switch has three positions with functions which vary depending on the application module used The allocation of the two setpoints and two measured values also depends on the application These four values can be displayed in the four-digit LED display panel by use of the appropriate selector key The setpoints can be modified with the <+> and < > keys; these also operate as repeating keys when continuously depressed Each of the four values is associated with one of the red channel LEDs With some applications, the setpoints can have upper and lower limits, adjustable from an operator terminal LED function test Depressing the two lower selector keys simultaneously should cause all segments of the display panel and the channel LEDs to light up Alarm handling Subject to the application selected, the display panel can also be used to indicate alarms A code between A1 and A9 can be displayed (A1 A8 for alarms defined in accordance with the application, and A9 for a common alarm) The operation of the controller is not affected by the presence of an alarm While the measured value or setpoint is displayed, the associated channel LED will flash, i e the alarm remains active The alarm code can be displayed again by pressing the two upper selector keys simultaneously