VRp Three-Phase Precision AC Voltage Regulator

Similar documents
M215-Z Safety Information (M LL-IG-ZC)

Panduit Basic Rack PDU

Panduit Basic Rack PDU with Local Meter

M215 Safety (M LL-S22-IG / S23-IG / S24-IG)

SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS

Installation Notes TII Model 341 Protector

Enphase S-Series Microinverter and Engage Cable Safety

M215 (M215-60) Safety

M250 (M LL) Safety

Series Amp Pad Mount Quick Connect Input and Output Power Panels

Installing the Cisco AS5400XM Universal Gateway

Replacing the Power Supply

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

Junos WebApp Secure 5.0 Hardware Guide

Model 7416LED

EATON Transformer Module

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Series Amp Quick Connect Input and Output Power Panels

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Eaton 9PX PowerPass Distribution Modules and Transformers 9PXTFMR5, 9PXPPDM2, 9PXTFMR11, and 9PXPPDM1 User's Guide

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

INSTALLATION INSTRUCTIONS STZ-R SERIES (ENGLISH)

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

Three Phase Residential Solution for Australia, System Design and Installation Guidelines

PV Rapid Shutdown device

Wise HP33 THREE PHASE HIGH PRECISION AVR SURVO-MOTOR AUTOMATIC VOLTAGE STABILIZER

TBX-1316 High-Voltage Attenuator Terminal Block

Westell. Breaker Panel Technical Practice NPDRP1114

Breaker Panel Technical Practice NPDRP1114

NI PXIe-1062Q Power Supply Shuttle

Installing the Cisco MDS 9020 Fabric Switch

Installation NOTICE. S&C IntelliCap Automatic Capacitor Control. Table of Contents. Instruction Sheet

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

NI PXI-1042 POWER SUPPLY SHUTTLE USER GUIDE

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Installation. MGE Galaxy 3500 and Smart-UPS VT. Maintenance Bypass, Distribution and Transformer Cabinet

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

8x16, 2-Wire Terminal Block for the NI PXI The following conventions are used in this guide:

SVP110 SURGE VOLTAGE PROTECTOR INSTRUCTION MANUAL

5401 and 5402 Digital I/O Modules

Electrical Integration of PV Systems. Ridha Hamidi, Ph.D.

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD)

Installing the Tracer MP503 Input/Output Module Ordering number: ,

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

Broadband Automatic Disconnect Switch. User Manual

Instruction Manual: IM E

TECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2

Enphase Engage Cable and Accessories

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

Hardware Installation. Tracer MP581 Programmable Controller CNT-SVN01C-EN

SPECIAL SPECIFICATION 1864 Pole Mounted Cabinet

hp uninterruptible power system r12000 xr models installation instructions

SVP48 SURGE VOLTAGE PROTECTOR INSTRUCTION MANUAL

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Models beginning with 2M, 2L or 2X. Product Description. Technical Specifications. Installation Instructions. Series 2000 Multiple Meter Units (MMUs)

one cool inverter. GT Series Solar Inverter Quick Install Guide v1.4

Type Terminal Block Connector No. of poles Appearance Model 40 XW2B-40G4 50 XW2B-50G4 40 XW2B-40G5 *1 50 XW2B-50G5 60 XW2B-60G5 40 XW2B-40G5-T

Site Preparation CHAPTER

TRC-190 User s Manual


VFI RTG PDU 6-10K. Installation and user manual. Service and support: Call your local service representative

Installation Instructions & User Manual POWERWARE TVSS ZONESENTINEL. AC Panel Transient Voltage Surge Suppressors

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

Installation and Operation Manual

MODEL 3312 LED

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Multi Unit Enclosed Meter

Power Supply and Fan Module Installation

Temperature. Power requirements. Weight. Dimensions

NI PXI-1042 Series Power Supply Shuttle

DANGER DANGER: is used in this manual to warn of high voltages capable of causing shock, burns, or death.

Liebert MicroPOD 230V

Type Terminal Block Connector No. of poles Appearance Model 40 XW2B-40G4 50 XW2B-50G4. 40 XW2B-40G5 Flat Cable Connectors

MicroTech II TM Remote I/O Panel Installation Manual

PS/IO Circuit Board Retrofit

Total Home Surge Protection for Point-of-Entry. FirstSurge TM. User Manual - Canada (English)

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

INSTALLATION INSTRUCTIONS FOR

Integrated Metering Systems, Inc.

Total Protection Solutions Surge Protective Devices SurgeTrack Series: 080, 120, 160, 240, 300 and 400

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W.

EMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina

CONTA-ELECTRONICS. CONTA-PROTECT overvoltage protection

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

MINI-PS AC/10-15DC/8

Quick Start Guide TS A

C5C Cross-Connect System

POWER AVAILABILITY 2U POD USER MANUAL. Power Output Distribution 230 Volt

Installing the Cisco 2524 and Cisco 2525 Routers

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

DRAFT. Application Note: Modbus/RS485 Wiring for Conext Core XC Series Inverters. 1.0 Introduction DANGER. 1.1 Related Documents

Configurable Output Distribution. 120V / 208V / 240V 60Hz. User Manual English

Transcription:

VRp-22500-0338 Three-Phase Precision AC Voltage Regulator INSTALLATION INSTRUCTIONS Inspection and Unpacking Please inspect the wooden crate for obvious shipping damage. Some crates contain up to six (6) units, each individually shrink-wrapped. If no visible damage to crate is found, proceed to remove the cover using a suitable Phillips screwdriver. Proceed to remove the sides to expose the units. Insert a lifting device into the lifting brackets on top of the VRp unit, remove the unit from the pallet inspect for damages until all units are checked. File claim with the freight carrier if any damage is found, contact TSi if a replacement unit needs to be purchased. If no damage is found, proceed to remove the protective shrink-wrap film from each unit. Leave the lifting brackets in place, as they are required during installation. Mounting VRp-22500-0338 is designed for use with the ILC-22500-0338 isolation line conditioner cabinet. Proceed as follows: 1. Invert the wall fixing brackets on the VRp cabinet Bracket Page 1 of 6

1. Place the VRp cabinet on top of the ILC cabinet and mark the wall for hole drilling. 2. Use wood screws of suitable size if holes line up with wooden studs; for concrete surfaces a carbide tip drillbit is required drill a hole deep enough for insertion of a concrete anchor. Insert anchor, put VRp on top of ILC and tighten screws; if only drywall is available the installer should consider using a piece of wood to bridge the gap between wall studs. 3. After securing VRp remove lifting brackets and replace screws. Keep the lifting brackets in case they are required later. Page 2 of 6

Electrical VRp-22500-0338 is designed to receive power from ILC-22500-0338 ONLY. DO NOT INSTALL VRP USING ANY OTHER POWER SOURCE UNLESS APPROVED BY TSI POWER. INSTALLING VRP WITHOUT AN APPROVED POWER SOURCE MAY RESULT IN VOIDED WARRANTY. ILC-22500-0338 provides a three-phase output plus neutral and ground (5 wire). The voltage is either 400/230VAC or 415/240VAC depending on country of installation. VRp-22500 uses a three-pole, 40A circuit breaker for over current protection and is connected in series with the output. THIS BREAKER IS NOT A DISCONNECT, NOR DOES IT PROVIDE INPUT PROTECTION. The ILC-22500-0338 has a three-pole, 50A circuit breaker on its input. The two (2) units together provide the necessary input/output protection. Please refer to ILC-22500-0338 installation instructions for information on this unit. NOT CONTAINED HEREIN. Grounding and Bonding VRp/ILC are not a replacement for proper site grounding and bonding. Be sure to follow proper site preparation procedures. NOT CONTAINED HEREIN. Extra Lightning Protection VRp/ILC together are designed to withstand Normal and Common-Mode indirect surge voltages and have internally coordinated surge protection devices. VRP ITSELF IS NOT A SURGE PROTECTIVE DEVICE (SPD) AND REQUIRES ILC TO PROVIDE PROTECTION FOR THE LOAD, AS WELL AS ITSELF. DO NOT INSTALL VRP WITHOUT ILC AS THIS WILL RESULT IN VOIDED WARRANTY AND RISK TO THE CONNECTED LOAD. If immunity against the more severe surges resulting from lightning strokes (defined by LPZ0a and LPZ0b) is required, it is recommended that an external surge diverter capable of withstanding IEC-61312 be installed. WARNING: MAKE SURE THAT VOLTAGE SUPPLY TO VRp IS OFF BY SWITCHING OFF UPSTREAM ILC-22500-0338 SUPPLY CIRCUIT BREAKER BEFORE PROCEEDING! Take care to follow local electrical codes where unit is installed. Page 3 of 6

Power entry is through two circular holes on the upper left side of unit. Use the two provided strain-relief connectors to route cable between ILC and VRp. Use lower entry point for power supplied from ILC and the upper exit for output from VRp. If compliance with North-American electrical standards is required, use 1 conduit connectors (not provided). Use minimum AWG 8 (8.4 square mm). All conductors must be of the same size. TSi recommends using stranded copper wire with a minimum 105 C insulation system. Note that three wires plus neutral and ground are required for both input and output. Insert wire through the strain-relief connectors. Ensure that there is enough wire to reach the respective terminal, take care to leave enough slack. Strip approximately 3/8 (or 10 mm) insulation from the end of each pair of (5) wires. Page 4 of 6

Input terminals are located on a DIN-rail inside the VRp cabinet on the left side. The threephase Output is provided by the three-pole circuit breaker on the left side of the cabinet neutral and ground conductors must be connected to the DIN-rail terminals next to the circuit breaker. The input terminals are marked as follows: L1in for phase A, L2in for phase B, L3in for phase C, NI for neutral in, G for input earth ground, terminal is green/yellow stripes. The output terminals are marked as follows: The OUTPUT label below the circuit breaker from left to right: L3 for phase C, L2 for phase B, L1 for phase A. The output neutral is located on the DIN-rail next to the circuit breaker and is marked: NO The output earth ground, yellow/green stripe, is located to the left of the NO terminal on the DIN-rail. VERIFY PHASE SEQUENCE BEFORE PROCEEDING. MAKE ABSOLUTELY SURE THAT INPUT/OUTPUT ARE NOT REVERSED AS SERIOUS DAMAGE WILL OCCUR WHEN ENERGIZING AN INCORRECTLY WIRED UNIT. Before proceeding to the next step, make sure that ILC-22500-0338 produces a phase to neutral output voltage of between 220 to 240VAC. Using a volt meter, check each phase to neutral to verify proper voltage. Turn the breaker off. Carefully insert each wire into the appropriate terminal, taking care to ensure that all strands are inserted properly. Tighten each terminal screw, and perform a pull test to make sure the connection is adequate. Note that failure to follow these instructions can lead to malfunction or short circuit. Page 5 of 6

Energizing VRp 1. Close the front door, 2. Switch on the ILC-22500-0338 circuit breaker, 3. VRp is now energized, 4. After a short blink of the Amber BYPASS LED the Green NORMAL LED, located on the left of each row, should be ON. 5. The Green OVP LED, located to the right of each row, should also be ON, 6. VRp is now operational, 7. To turn on power to the load open the VRp cabinet door be careful not to touch any live circuits. 8. Switch on the Output circuit breaker and close the door. VRp is operating normally when the green LEDs in each of the three rows are lit. Please contact TSi or its representative in your country if any of the green LEDs are off; or if a Red or Amber LED is permanently lit. Page 6 of 6