GETTING STARTED GUIDE NI AO, 0 ma to 20 ma, 16 Bit Simultaneous

Similar documents
GETTING STARTED GUIDE NI V, 32-Channel (Sinking Input), 7 µs C Series Digital Module

GETTING STARTED GUIDE NI Channel Solid-State Relay (SSR) Digital Output Module

GETTING STARTED GUIDE NI Channel, 60 V, High-Speed, Sourcing Digital Output Module

GETTING STARTED GUIDE NI Channel, 50 Arms Continuous, 24-Bit, Analog Input Module

GETTING STARTED GUIDE NI S/s/channel, 4-Channel C Series Universal Analog Input Module

GETTING STARTED GUIDE NI AI, 100 S/s/ch Simultaneous, Universal Measurements

GETTING STARTED GUIDE NI Ch 24 V Sinking DI, 8-Ch 24 V Sourcing DO SIL3 Capable

SAFETY, ENVIRONMENTAL, AND REGULATORY INFORMATION. NI CompactDAQ Four-Slot Controller with Quad-Core Processor

R Series Digital I/O Module for PCI Express, 128 DIO, 512 MB DRAM, Kintex-7 160T FPGA. This document describes how to begin using the PCIe-7821R.

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9476E. 32-Channel, 24 V Sourcing Digital Output Module

R Series Reconfigurable I/O Module (AI, AO, DIO) for PXI Express, 6 AI, 18 AO, 48 DIO, 1 MS/s AIO, 512 MB DRAM, Kintex-7 160T FPGA

NI crio-9101/9102/9103/9104

NI USRP-2900/2901. Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. Universal Software Radio Peripheral

Electromagnetic Compatibility Guidelines

IVN Safety Guidelines GETTING STARTED GUIDE. 100BASE-T1 Media Converter

R Series for PXI Express Digital RIO with Kintex-7 325T FPGA. ni.com/manuals. This document explains how to install and configure the NI PXIe-7822R.

NI Safety Guidelines. Safety Guidelines for Hazardous Locations GETTING STARTED GUIDE. Ethernet Expansion Chassis for C Series Modules

Electrical. SPECIFICATIONS SH Cable

R Series for USB Multifunction RIO with Kintex-7 70T FPGA. ni.com/manuals. Electromagnetic Compatibility Guidelines

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI Channel, Sinking Digital Input/Sourcing Digital Output Module. ni.

Contents. Software. CALIBRATION PROCEDURE NI Channel, 300 Vrms, 24-Bit, Simultaneous, Channel-to-Channel Isolated Analog Input Module

Reconfigurable Embedded Chassis with Integrated MXI-Express (x1) MXI-Express Switch

Embedded Real-Time Controller with Reconfigurable FPGA for C Series Modules. This document describes how to begin using the NI crio-9064.

Contents. Software. CALIBRATION PROCEDURE NI Channel, ±5 V, 24-Bit Software-Selectable IEPE and AC/DC Analog Input Module

CALIBRATION PROCEDURE PXIe channel, 16-bit, 400 ks/s/ch, Ch-Ch Isolated Analog Input Module. ni.com/manuals

±10 V, 20 MS/s/ch, 14-Bit, 4-Channel C Series Digitizer Module

NI R Series. Contents. Software CALIBRATION PROCEDURE

NI PCIe-784xR, NI PXI-784xR, NI PXIe-784xR, NI USB-784xR, NI PCIe-785xR, NI PXI-785xR, NI PXIe-785xR, NI USB-785xR, and NI PXIe-786xR

Contents. Software. CALIBRATION PROCEDURE NI 9216/ Channel, 24-Bit, 100 Ω/1000 Ω RTD Analog Input Module

12-Channel, ±24 V Precision PXI Source Measure Unit

24-Channel, ±24 V Precision PXI Source Measure Unit

Embedded CompactRIO Controller with Real-Time Processor and Reconfigurable FPGA

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI Stepper Drive. ni.com/manuals

NI CVS Required Components. Optional Equipment GETTING STARTED GUIDE. Compact Vision System with USB3 Vision and Reconfigurable I/O

SH Cable Specifications

NI PXIe-4138/4139. Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. Single-Channel System SMU

NI Channel, 0 20 ma, 16-Bit Analog Current Output Module

NI USB Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. 10 MHz to 18 GHz RF Power Meter

R Series for USB Multifunction RIO with Kintex-7 70T FPGA. ni.com/manuals

R Series for USB Multifunction RIO with Kintex-7 160T FPGA. ni.com/manuals. Electromagnetic Compatibility Guidelines

CALIBRATION PROCEDURE NI channel, ±2- ma/±10 V, 24-bit Analog Input Module. ni.com/manuals

R Series for USB Multifunction RIO with Kintex-7 160T FPGA. ni.com/manuals

Embedded CompactRIO Controller with Real-Time Processor and Reconfigurable FPGA

NI PXIe Contents GETTING STARTED GUIDE. RF Preselector Module

NI SD Card Memory Module

NI sbrio Safety Guidelines GETTING STARTED GUIDE. Single-Board RIO OEM Devices. This document describes how to begin using the NI sbrio-9627.

NI PXI Contents GETTING STARTED GUIDE. 8 GHz RF Amplifier

NI 9503 Stepper Drive

GETTING STARTED GUIDE NI Port, RS232 Serial Module. Français Deutsch 日本語한국어简体中文. ni.com/manuals

NI PXIe-4080/4081/4082

Bracket and Mounting Dimensions

NI ELVIS RIO Control Module

INSTALLATION INSTRUCTIONS SH160F-160M-NI SwitchBlock Cable

SPECIFICATIONS AND FEATURES GUIDE NI Serial Legacy Hardware

GETTING STARTED GUIDE NI Port, RS485/RS422 Serial Module. Français Deutsch 日本語한국어简体中文. ni.com/manuals

NI CMS Contents MAINTAINING HARDWARE. NI Condition Monitoring System for NI InsightCM Enterprise

Related Information Refer to the NI Switches Help for detailed information about features and programming options for your NI switch product.

CALIBRATION PROCEDURE NI PXIe Channel, Isolated Voltage/Current Analog Output Module

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9208E 16-Channel, ±20 ma, 24-Bit Analog Input Module

Electromagnetic Compatibility Guidelines

PXIe Contents GETTING STARTED GUIDE. 32-Channel Digital Pattern Instrument

NI PXIe-5160/5162. Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. 10-Bit Oscilloscope

To access NI 5622 documentation, navigate to Start»All Programs»National Instruments» NI-SCOPE»Documentation.

GETTING STARTED GUIDE NI Synchronization Module

NI 9472 DATASHEET. 8 DO, 6 V to 30 V, Sourcing, 100 μs

NI REM Remote I/O Overview DATASHEET. Bus Coupler for Remote I/O

NI CMS Contents MAINTAINING HARDWARE. NI Condition Monitoring System for NI InsightCM Enterprise

SCC-AO10 Isolated Analog Output Module

This installation guide describes how to install and connect signals to the NI TBX-2808 screw terminal accessory for use with NI SwitchBlock cards.

You need the following to set up and use your terminal block:

NI 6521 Specifications

Contents. CALIBRATION PROCEDURE NI PXIe-5624R 2 GS/s, 12-Bit IF Digitizer

NI SMD-7610 Stepper Drives and NI 9512 C Series Modules

NI REM Remote I/O Overview DATASHEET. Digital Input Module for Remote I/O

NI REM Remote I/O Overview DATASHEET. Analog Output Module for Remote I/O

Single-Channel Precision System Source Measure Unit (SMU)

USER GUIDE USB-634x/635x/636x OEM X Series USB-6341/6343/6356/6361/6363/6366 OEM Devices

NI CMS-9068 and NI MMS-9068

36 V, 32-Channel (Sourcing Output), 500 µs C Series Digital Module. DSUB are referred to inclusively as the NI 9476.

NI 9375 DATASHEET. 16 DI/16 DO, 30 VDC, 7 μs Sinking DI, 500 μs Sourcing DO

Figure 1. NI-7935R. Related Information For information about the device specifications, refer to the NI-7935R Specifications at ni.com/manuals.

Thermal Kit for NI sbrio-9607/9627/9637

SCC-RLY01 Relay Module

SCXI -1104/C. Contents CALIBRATION PROCEDURE. For NI-DAQmx

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9870E

NI CB-37F-LP. Introduction INSTALLATION GUIDE. Connector Block for 37-Pin D-Sub Devices

NI REM Remote I/O Overview DATASHEET. Digital Output Module for Remote I/O

NI USB Introduction USER GUIDE AND SPECIFICATIONS. 4-Channel, ±10 V, 16-Bit Analog Voltage Output Module

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9871E

CALIBRATION PROCEDURE CAL Contents. Software

Embedded Direct Injector Control and Measurement (DCM) Device with Real-Time Processor and Reconfigurable FPGA

NI PXI-2567 Specifications

SCXI -1102/B/C. Contents CALIBRATION PROCEDURE. For NI-DAQmx

NOTE TO USERS NI 61xx Pinout Labels for the SCB-68 Multifunction I/O S Series Modules/Devices Using the 68-Pin Shielded Connector Block

GETTING STARTED NI SMD-7611/7612 Stepper Drives and NI 9512 C Series Modules

NI PXI/PXIe/PCI Contents GETTING STARTED GUIDE. 14-Bit, 100 MS/s PXI Oscilloscope

GETTING STARTED GUIDE

INSTALLATION GUIDE AND SPECIFICATIONS PXIe-4844

NI 9266 Datasheet DATASHEET. 8 AO, 0 ma to 20 ma, 16 Bit Simultaneous

INSTALLATION GUIDE AND TERMINAL BLOCK SPECIFICATIONS NI PXIe-4322 and TB Channel, Isolated Voltage/Current Analog Output Module

Transcription:

GETTING STARTED GUIDE NI 9266 8 AO, 0 ma to 20 ma, 16 Bit Simultaneous

This document explains how to connect to the NI 9266. In this document, the NI 9266 with screw terminal and the NI 9266 with DSUB are referred to inclusively as the NI 9266. Note Before you begin, complete the software and hardware installation procedures in your chassis documentation. Note The guidelines in this document are specific to the NI 9266. The other components in the system might not meet the same safety ratings. Refer to the documentation for each component in the system to determine the safety and EMC ratings for the entire system. Safety Guidelines Operate the NI 9266 only as described in this document. Caution This icon denotes a caution, which advises you to consult documentation where this symbol is marked. 2 ni.com NI 9266 Getting Started Guide

Caution Do not operate the NI 9266 in a manner not specified in this document. Product misuse can result in a hazard. You can compromise the safety protection built into the product if the product is damaged in any way. If the product is damaged, return it to NI for repair. Hazardous Voltage This icon denotes a warning advising you to take precautions to avoid electrical shock. Safety Guidelines for Hazardous Voltages If hazardous voltages are connected to the device, take the following precautions. A hazardous voltage is a voltage greater than 42.4 V pk voltage or 60 V DC to earth ground. Caution Ensure that hazardous voltage wiring is performed only by qualified personnel adhering to local electrical standards. Caution Do not mix hazardous voltage circuits and human-accessible circuits on the same module. Caution Ensure that devices and circuits connected to the module are properly insulated from human contact. NI 9266 Getting Started Guide National Instruments 3

Caution When terminals are hazardous live, you must ensure that devices and circuits connected to the module are properly insulated from human contact. You must use the NI 9928 backshell kit to ensure that the terminals are not accessible. NI 9266 with Screw Terminal Safety Voltages Connect only voltages that are within the following limits: AO-to- and V sup -to- Isolation Channel-to-channel ±36 V DC maximum None Channel-to-earth ground, V sup -to-earth ground, or -to-earth ground Continuous Withstand up to 3,000 m 250 V RMS, Measurement Category II 3,000 V RMS, verified by a 5 s dielectric withstand test Measurement Category II is for measurements performed on circuits directly connected to the electrical distribution system. 4 ni.com NI 9266 Getting Started Guide

This category refers to local-level electrical distribution, such as that provided by a standard wall outlet, for example, 115 V for U.S. or 230 V for Europe. Caution Do not connect the NI 9266 with screw terminal to signals or use for measurements within Measurement Categories III or IV. NI 9266 with DSUB Safety Voltages Connect only voltages that are within the following limits. AO-to- and V sup -to- Isolation Channel-to-channel ±36 V DC maximum None NI 9266 Getting Started Guide National Instruments 5

Channel-to-earth ground Continuous Withstand up to 3,000 m Withstand up to 5,000 m 60 V DC, Measurement Category I 1,000 V RMS, verified by a 5 s dielectric withstand test 860 V RMS Measurement Category I is for measurements performed on circuits not directly connected to the electrical distribution system referred to as MAINS voltage. MAINS is a hazardous live electrical supply system that powers equipment. This category is for measurements of voltages from specially protected secondary circuits. Such voltage measurements include signal levels, special equipment, limited-energy parts of equipment, circuits powered by regulated low-voltage sources, and electronics. Caution Do not connect the NI 9266 with DSUB to signals or use for measurements within Measurement Categories II, III, or IV. Note Measurement Categories CAT I and CAT O are equivalent. These test and measurement circuits are for 6 ni.com NI 9266 Getting Started Guide

other circuits not intended for direct connection to the MAINS building installations of Measurement Categories CAT II, CAT III, or CAT IV. Safety Guidelines for Hazardous Locations The NI 9266 is suitable for use in Class I, Division 2, Groups A, B, C, D, T4 hazardous locations; Class I, Zone 2, AEx na IIC T4 Gc and Ex na IIC T4 Gc hazardous locations; and nonhazardous locations only. Follow these guidelines if you are installing the NI 9266 in a potentially explosive environment. Not following these guidelines may result in serious injury or death. Caution Do not disconnect I/O-side wires or connectors unless power has been switched off or the area is known to be nonhazardous. Caution Do not remove modules unless power has been switched off or the area is known to be nonhazardous. Caution Substitution of components may impair suitability for Class I, Division 2, or Zone 2. Caution The system must be installed in an enclosure certified for the intended hazardous (classified) NI 9266 Getting Started Guide National Instruments 7

location, having a tool secured cover/door, where a minimum protection of at least IP54 is provided. Special Conditions for Hazardous Locations Use in Europe and Internationally The NI 9266 has been evaluated as Ex na IIC T4 Gc equipment under DEMKO 12 ATEX 1202658X and is IECEx UL 14.0089X certified. Each NI 9266 is marked II 3G and is suitable for use in Zone 2 hazardous locations, in ambient temperatures of -40 C Ta 70 C. If you are using the NI 9266 in Gas Group IIC hazardous locations, you must use the device in an NI chassis that has been evaluated as Ex nc IIC T4, Ex IIC T4, Ex na IIC T4, or Ex nl IIC T4 equipment. Caution Transient protection shall be provided that is set at a level not exceeding 140% of the peak rated voltage value of 85 V at the supply terminals to the equipment. Caution The system shall only be used in an area of not more than Pollution Degree 2, as defined in IEC/EN 60664-1. 8 ni.com NI 9266 Getting Started Guide

Caution The system shall be mounted in an ATEX/IECEx-certified enclosure with a minimum ingress protection rating of at least IP54 as defined in IEC/EN 60079-15. Caution The enclosure must have a door or cover accessible only by the use of a tool. Electromagnetic Compatibility Guidelines This product was tested and complies with the regulatory requirements and limits for electromagnetic compatibility (EMC) stated in the product specifications. These requirements and limits provide reasonable protection against harmful interference when the product is operated in the intended operational electromagnetic environment. This product is intended for use in industrial locations. However, harmful interference may occur in some installations, when the product is connected to a peripheral device or test object, or if the product is used in residential or commercial areas. To minimize interference with radio and television reception and prevent unacceptable performance degradation, install and use this product in strict accordance with the instructions in the product documentation. NI 9266 Getting Started Guide National Instruments 9

Furthermore, any changes or modifications to the product not expressly approved by National Instruments could void your authority to operate it under your local regulatory rules. Caution To ensure the specified EMC performance, operate this product only with shielded cables and accessories. Special Conditions for Marine Applications Some products are Lloyd s Register (LR) Type Approved for marine (shipboard) applications. To verify Lloyd s Register certification for a product, visit ni.com/certification and search for the LR certificate, or look for the Lloyd s Register mark on the product. Caution In order to meet the EMC requirements for marine applications, install the product in a shielded enclosure with shielded and/or filtered power and input/output ports. In addition, take precautions when designing, selecting, and installing measurement probes and cables to ensure that the desired EMC performance is attained. 10 ni.com NI 9266 Getting Started Guide

Preparing the Environment Ensure that the environment in which you are using the NI 9266 meets the following specifications. Operating temperature -40 C to 70 C (IEC 60068-2-1, IEC 60068-2-2) Operating humidity (IEC 60068-2-78) Pollution Degree 2 Maximum altitude NI 9266 with screw terminal NI 9266 with DSUB Indoor use only. 10% RH to 90% RH, noncondensing 3,000 m 5,000 m Note Refer to the device datasheet on ni.com/manuals for complete specifications. NI 9266 Getting Started Guide National Instruments 11

NI 9266 Pinout AO0 AO1 AO2 AO3 AO4 AO5 AO6 AO7 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Vsup AO0 AO1 AO2 AO3 AO4 AO5 AO6 AO7 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 Vsup 12 ni.com NI 9266 Getting Started Guide

Table 1. Signal Descriptions Signal AO V sup Description Analog output signal connection Common reference connection to isolated ground No connection Voltage supply connection NI 9266 Getting Started Guide National Instruments 13

Connecting the NI 9266 External Power Supply _ Power Supply Vsup + DC/DC NI 9266 Isolated DAC Protection AO Load Common Mode Voltage 14 ni.com NI 9266 Getting Started Guide

Connecting an External Power Supply You must connect an external power supply with a 9 V DC to 30 V DC voltage range to the NI 9266. This power supply provides the current for the devices you connect to the module. You can connect only one external voltage supply to the NI 9266. 1. Connect the positive lead of the power supply to V sup. 2. Connect the negative lead of the power supply to. Caution Do not remove or insert modules if the external power supply connected to the V sup and pins is powered on. NI 9266 Connection Guidelines Make sure that devices you connect to the NI 9266 are compatible with the module specifications. You must use 2-wire ferrules to create a secure connection when connecting more than one wire to a single terminal on the NI 9266. NI 9266 Getting Started Guide National Instruments 15

For CAT II measurements, you must use a power supply with isolated DC outputs. Each channel has a common terminal,, that is internally connected to the isolated ground reference of the module. High-Vibration Application Connections If your application is subject to high vibration, NI recommends that you follow these guidelines to protect connections to the NI 9266: Use ferrules to terminate wires to the detachable connector. Use the NI 9928 connector backshell kit. Overvoltage Protection The NI 9266 provides overvoltage protection for each channel. Note Refer to the device datasheet on ni.com/manuals for more information about overvoltage protection. 16 ni.com NI 9266 Getting Started Guide

Where to Go Next CompactRIO NI CompactDAQ NI 9266 Datasheet NI-RIO Help LabVIEW FPGA Help NI 9266 Datasheet NI-DAQmx Help LabVIEW Help RELATED INFORMATION C Series Documentation & Resources ni.com/info cseriesdoc Services ni.com/services Located at ni.com/manuals Installs with the software NI 9266 Getting Started Guide National Instruments 17

Worldwide Support and Services The NI website is your complete resource for technical support. At ni.com/support, you have access to everything from troubleshooting and application development self-help resources to email and phone assistance from NI Application Engineers. Visit ni.com/services for NI Factory Installation Services, repairs, extended warranty, and other services. Visit ni.com/register to register your NI product. Product registration facilitates technical support and ensures that you receive important information updates from NI. A Declaration of Conformity (DoC) is our claim of compliance with the Council of the European Communities using the manufacturer s declaration of conformity. This system affords the user protection for electromagnetic compatibility (EMC) and product safety. You can obtain the DoC for your product by visiting ni.com/certification. If your product supports calibration, you can obtain the calibration certificate for your product at ni.com/calibration. 18 ni.com NI 9266 Getting Started Guide

NI corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas, 78759-3504. NI also has offices located around the world. For telephone support in the United States, create your service request at ni.com/support or dial 1 866 ASK MYNI (275 6964). For telephone support outside the United States, visit the Worldwide Offices section of ni.com/niglobal to access the branch office websites, which provide up-to-date contact information, support phone numbers, email addresses, and current events. NI 9266 Getting Started Guide National Instruments 19

Information is subject to change without notice. Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for information on NI trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering NI products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/ patents. You can find information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer to the Export Compliance Information at ni.com/legal/export-compliance for the NI global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015. 2017 National Instruments. All rights reserved. 376325C-01 October 13, 2017