Features. Measuring and Monitoring Relays K8AB Series. Cut by 50% Industry First! Two SPDT Outputs Available in New Models DIN Sized at 22.

Similar documents
MEASURING AND MONITORING RELAYS

MEASURING AND MONITORING RELAYS

MEASURING AND MONITORING RELAYS

Measuring and Monitoring Relays

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

G3S4-A 5 VDC 12 VDC 24 VDC 0.6 A at 75 to 264 VAC (See note 1.) G3S4-A1 5 VDC 12 VDC 24 VDC Yes G3SD-Z01P-PD 1 A at 3 to 26 VDC (See note 2.

Model Number Structure

Switching Frequency Test Conditions (AC3/AC4/AC53-a)

Time-limit operation/ self-resetting DPDT --- H3M H3M with Y92F-40 adapter SPDT SPDT H3M-H H3M-H with Y92F-40 adapter

NPN output. 200 mm. Type Cable length Model Remarks

Model Number Structure

Photoelectric Sensor

ID Sensor Modules CJ1W-V600C11/V600C12 CS1W-V600C11/V600C12

Reverse Protection Relay 2. Control Power Supply Voltage None: 200/220 VAC 380: 380/400 VAC 440: 440 VAC

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

D5B. Detects Objects in Multiple Directions with High Sensitivity, Ideal for Robotics. Mechanical Touch Switch. Model Number Structure

Shape Model Measurement range Model Straight 50 to 300 mm. Straight 70 to 800 mm

Reliable Detection Unaffected by PCB Holes or Notches. PCB Sensors. Ordering Information. Sensors [Refer to Dimensions on page 4.

NJ-Series Power Supply Unit NJ-PA/PD

Communication Unit Dedicated for RFID V680 Allowing Direct Connection to OMRON PLC CJ/ CS/NJ-series

Name Specifications Model Standards. Converts RS-233C to RS-422A/RS-485. CJ1W-CIF11 UC1, N, L, CE

Power supply voltage Output configuration Output phases Resolution (pulses/rotation) Model. 100, 200, 360 E6A2-CWZ5C (resolution) 0.

Snap-in (front mounting) Locking type. Terminals Solder terminals *1 Color Light gray Black A7BL-207 *2 A7BL *2

Type Terminal Block Connector No. of poles Appearance Model 40 XW2B-40G4 50 XW2B-50G4 40 XW2B-40G5 *1 50 XW2B-50G5 60 XW2B-60G5 40 XW2B-40G5-T

EE-SX77/87. Slim, Compact Photomicrosensor that is still easy to use. Photomicrosensor with Slim Cable (Non-modulated) Ordering Information

CJ1W-INT01. CJ-series Interrupt Input Units. High-speed Starting of I/O Interrupt Tasks. Use Up to Two Units for a Total of Up to 32 Interrupt Inputs.

Limit Switch Connectors

Limit Switch Connectors

Model Number Structure

Handheld Reader Writer

Model Number Structure

Model Number Structure

Intelligent Flag Amplifier

(75 to 264 VAC) 12 VDC 24 VDC No 5 VDC G3MC-202PL 12 VDC 24 VDC

Model NPN output PNP output Standard. configuration

EE-SX97 40% Built-in connector enables downsizing and easier connection. Protective circuit for safe operation. Slot-type Photomicrosensor.

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

Model Number Structure

Output configuration Contact form Operation indicator Cable length Model PNP open collector. 1 m D5F-2B10 (+ common) ON when operated

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

M16. Cylindrical 16-dia. Indicator. Indicator (Cylindrical 16-dia.) List of Models. Same basic design as the A16 Pushbutton Switch.

G9SA. Safety Relay Unit. The G9SA Series Offers a Complete Line-up of Compact Units. Model Number Structure

E2K-X4ME1 2M E2K-X4ME2 2M

Solid State Relays with Failure Detection Function

Long Sensing-distance Capacitive Separate Amplifier Proximity Sensor E2J-W10MA 1M E2J-W20MA 1M. E2J-JC4A Amplifier Unit

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

Smart Sensors (with Ultra-High-Speed CCD Camera) ZFV Series

Aluminum-detecting Proximity Sensor (Separate Amplifier Type)

Conductive Level Controller

S82S (3/7.5-W Models)

G3FM. Model Number Structure. Ordering Information. Solid State Relays. Model Number Legend. List of Models

MGN. Ordering Information. Specifications. Heavy Duty Power Relay. Contact Data. 30 Amp Heavy Duty Relay. Heavy Duty Power Relay MGN 325

Multi-beam, finger- and hand protection safety sensor. Multi-beam, finger and hand protection safety sensor. Model number structure

Name No. of I/O points Model Safety inputs: 12, test outputs: 4

Connecting Sockets, Mounting Brackets, DIN Rails

E3S-GS/VS. Both Red-light Models and Greenlight Models to Detect a Wide Variety of Colors. Small Spot/Mark Sensor with Built-in Amplifier

CQM1 I/O Terminal Block Conversion Adapter. Easy and secure replacement by reusing the I/O terminal block wiring.

G3H/G3HD. Model Number Structure. Solid State Relays Model Number Legend

Long-time range model (0.1 min to 10 h) 24 VAC; SPDT H3RN-1 H3RN-11 12, 24 VDC DPST-NO H3RN-2 H3RN-21

Model Number Structure

G3F/G3FD. Model Number Structure. Solid State Relays Model Number Legend

Model Number Structure

E2EC. High-sensitivity DC 2-Wire Sensors and Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information

CX-One Ver.4. FA Integrated Tool Package CX-One. Greater Integration with the CX-One. Features

CX-One Ver.4. FA Integrated Tool Package CX-One. Greater Integration with the CX-One. Features

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

Model Number Structure

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

M22. Round Indicator Series with 22 dia. and 25 dia. (when using a ring) Indicator (Cylindrical 22/25-dia.) List of Models. Model Number Structure

Origin Position Control of an X-Y Table Coaxiality Inspection Checking Turret Indexing Position D5A

Peripheral Devices for Environment-resistive Slaves

The Next-generation Sensor Networking Units That Revolutionize the Workplace from Introduction and Startup though Operation. Fiber Units.

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

Options. 24-VDC service power supply. RUN output. No Yes No 24 VDC 70 W NX-PD7001

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

Tina 1A Blanking plug

CS1W-B7A. CS-series B7A Interface Unit. It transmits 16 points of I/O signals per word with a pair of cables. Easy and minimized wiring effort,

DPDT Basic Switch for Two Independent Circuit Control

Dimension A. Dimension B

Three-phase Phase-sequence Phase-loss Relay

Model Number Structure. Ordering Information. Switch Mode Power Supply S82K (3/7.5/15/30/50/90/100-W Models) Model Number Legend.

No. of I/O points Safety inputs Test outputs Safety outputs NE1A-SCPU01-EIP NE1A-SCPU02-EIP 1.0

E2EC. Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

Electroformed Probe Pins XP3A

Model A7BS

Number of input channels

Solid-state Timer H3FA. Model Number Structure. DIP Model Timer for PC Board Use Provides Contact and Solid-state Output

Type Terminal Block Connector No. of poles Appearance Model 40 XW2B-40G4 50 XW2B-50G4. 40 XW2B-40G5 Flat Cable Connectors

CSM_PYF S/P2RF- -S_DS_E_2_5

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2

Sensing method Appearance Connection method Sensing distance Model. Pre-wired (2 m) Power supply Application Appearance Function Model

P7TF-IS16/OS16/OS08. I/O classification I/O points Internal I/O common Rated voltage Model 12 VDC P7TF-IS16 DC12 24 VDC P7TF-IS16 DC24 For inputs

Analog Input Unit. MACH No. MODE. Regulator. Servocontroller. Variable speed controller. Chart recorder

MACH No. MODE. Regulator. Servocontroller. Variable speed controller. Chart recorder

Photoelectric Sensor

Single-phase Voltage Relay

G9H. Ordering Information. Hybrid Power Relay. List of Model. Accessories (Order Separately) Connecting Socket Mounting Plate

E3Z-G. Photoelectric Sensor with Grooved Design and Easy Settings. Grooved-type Photoelectric Sensor with Built-in Amplifier. Ordering Information

Transcription:

Measuring and Monitoring Relays CSM_K8AB_series_Outline_DS_E_3_2 Industry First! Two SPDT Outputs Available in New Models DIN Sized at 22.5 mm Eight slim models featuring a variety of innovative new functions. Single-phase power : Current relay Voltage relay Upper-/lower-limit voltage relays Three-phase power : Phase-sequence phase-loss relay (Detected at startup.) Voltage phase-sequence phase-loss relay * Asymmetry phase-sequence phase-loss relay * Voltage relay Temperature : Temperature alarm device * Refer to the Q&A section for information on phase loss during operation. Features Slim 22.5-mm Design Features Two SPDT Relay Outputs (K8AB-VW, K8AB-PM, and K8AB-PW) Provides individual over voltage and under voltage settings and outputs. 1-/3-phase Power Supply Many customers require the individual upper and lower limit outputs that are normally available only in larger 45-mm relays. For the first time from any manufacturer, OMRON has achieved this and more in a slim-body design measuring just 22.5 mm. These relays not only offer advantages such as 3-phase power supply compatibility and a resistive load contact capacity of, but they also reduce panel production cost because they use 50% less space than previous models. Note: The relay output capacity for the K8AB-TH is 3 A at 250 VAC. Two SPDT Relay Outputs Relay 1 over voltage Contact capacity: Space Savings Cut by 50% DIN-sized at 22.5 mm Industry First Relay 2 under voltage (Compared with previous models) Pre-alarm Monitoring Mode Provides Advanced Warning (K8AB-VW Only) In plants and other sites that operate 365 days a year, unexpected shutdowns must be kept to an absolute minimum. OMRON addresses this problem with the K8AB-VW featuring a pre-alarm mode that can be set to two levels for two outputs. K8AB- VW makes scheduled maintenance possible because the pre-alarm mode provides advance warning of impending trip alarms. Mode 1 / AL1 AL2 Ry 1 Ry 2 Mode 2 / Pre-alarm warning AL1 AL2 Ry 1 Ry 2 Ry 1 Ry 2 Expanded Setting Range Ensures Over Voltage and Under Voltage Monitoring Flexibility and under voltage can be set for the full span of the allowable input range, so over voltage and under voltage can now be monitored with flexibility. Note: The setting range for operation time can be set within 30% to +25% of the range selected using the DIP switch on the Unit. Example: K8AB-PW 3-phase Voltage Relay Rated input voltage Three-phase, three-wire Mode 480-VAC setting 600 VAC Setting range Mode 3 / AL1 AL2 600 VAC Pre-alarm warning Setting range 336 VAC 336 VAC 1

Usable as a Simple Sensor Controller Accepts inputs of 4 to 20 ma or 0 to 10 V. Compatible with Commercial CTs The 1-Phase Current Relay can be used with commercial CTs for current measurement. DIN Track Mounting Gang-mounting is also possible. CT current on Applicable model secondary side Commercial CTs 0 to 1 A AC 2 0 to 5 A AC Note: OMRON-compatible CT: K8AC-CT200L Only the 3 can be used for AC operation at both 100 and 200 A. DIP Switch Function Selection Various relay functions can be selected using a DIP switch. This means that the number of models required can be reduced to 1/8 what it had been simply by installing a relay like the. An added advantage is that it reduces the inventory of maintenance parts. Single K8AB Monitors 3-phase Power Supply with 3 or 4 Wires (K8AB-PM, K8AB-PA, and K8AB-PW) OMRON Low-voltage Monitoring Relays can be used to monitor 3- phase power supplies with 3 or 4 wires simply by changing DIP switch settings. A Single K8AB Can Monitor a 3-phase Power Supply Anywhere in the World Reduces Maintenance Parts Inventory Example: 1-Phase Current Relay Resetting method Relay drive method Operating mode Phase to phase voltage (3 wires) DIP switch Function SW2 ON Manual reset OFF Automatic reset SW3 ON Normally open OFF Normally closed SW4 ON Over current OFF Under current Note: 1. The operating time can be set to 0.1 to 30 s. 2. SW1 of is not used. Phase to neutral voltage (4 wires) N SW3 ON ON OFF OFF SW4 ON OFF ON OFF K8AB-P@1 SW2 ON P-P 200 V 220 V 230 V 240 V OFF P-N 115 V 127 V 133 V 138 V K8AB-P@2 SW2 ON P-P 380 V 400 V 415 V 480 V OFF P-N 220 V 230 V 240 V 277 V Operation Level Indication by Flashing Indicator Checking the operating status has never been convenient because of the time it takes to reach the preset operation time. The K8AB eliminates this problem by featuring a flashing alarm indicator that clearly indicates the operating status. This has greatly simplified the task of checking on-site status particularly when operation settings are changed or an error occurs. Note: Excluding the K8AB-PH and K8AB-TH. Going to trip soon! Flashing Lit Ideal for Monitoring Current or Voltage Current Monitoring Applications (Single Phase) 2 can use standardized CT!! Application Simple Sensor Controller Process control signal (using a standardized CT) Current for motors and heaters (using a special CT) The trip alarm operates when the input reaches the operation range and the preset operation time has elapsed. Indicates a continuous trip. Measured current Input Ry1 Ry2 Notification by Flashing Indicator Applicable models Note: Special CT model: OMRON K8AC-CT200L Operating value setting range 4 to 20 ma DC 1 2 to 20 ma AC/DC 10 to 100 ma AC/DC 50 to 500 ma AC/DC 0 to 1 A AC 2 0.1 to 1 A AC/DC 0 to 5 A AC 0.5 to 5 A AC/DC 0.8 to 8 A AC/DC 0 to 200 A AC 3 (See note.) Operation time Operation time --- 10 to 100 A AC 20 to 200 A AC 2

Voltage Monitoring Applications (Single Phase) Application Direct current ( the output voltage of a shunt) Power supply line Measured voltage Applicable models 0 to 60 mv DC K8AB-VS1 0 to 100 mv DC K8AB-VW1 0 to 150 mv DC 12 VDC 24 VDC 100 VAC 115 VAC 200 VAC 480 VAC K8AB-VS2 K8AB-VW2 K8AB-VS3 K8AB-VW3 Operating value setting range 6 to 60 mv AC/DC 10 to 100 mv AC/DC 30 to 300 mv AC/DC 1 to 10 V AC/DC 3 to 30 V AC/DC 15 to 150 V AC/DC 20 to 200 V AC/DC 30 to 300 V AC/DC 60 to 600 V AC/DC Wire Connection 2 2.5 mm 2 solid or 2 1.5 mm 2 standard ferrules. Compliance with International Standards A third party has certified CE mark compliance. This device is in compliance with UL certification requirements. Selection Guide Product name 1-Phase Current Relay 1-Phase Voltage Relay 1-Phase Voltage Relay Phase-sequence, Phase-loss Relay *3 3-Phase Voltage, Phase-sequence, Phase-loss Relay 3-Phase Asymmetry, Phase-sequence, Phase-loss Relay 3-Phase Voltage Relay Temperature Monitoring Relay Model 1 2 *1 3 *2 K8AB-VS1 K8AB-VS2 K8AB-VS3 K8AB-VW1 K8AB-VW2 K8AB-VW3 K8AB-PH1 K8AB-PM1 K8AB-PM2 K8AB-PA1 K8AB-PA2 K8AB-PW1 K8AB-PW2 K8AB-TH11S K8AB-TH12S K8AB-TH11S K8AB-TH12S Nominal input I1-COM: 2 to 20 ma AC/DC I2-COM: 10 to 100 ma AC/DC I3-COM: 50 to 500 ma AC/DC I1-COM: 0.1 to 1 A AC/DC I2-COM: 0.5 to 5 A AC/DC I3-COM: 0.8 to 8 A AC/DC I2-COM: 10 to 100 A AC I3-COM: 20 to 200 A AC V1-COM: 6 to 60 mv AC/DC V2-COM: 10 to 100 mv AC/DC V3-COM: 30 to 300 mv AC/DC V1-COM: 1 to 10 V AC/DC V2-COM: 3 to 30 V AC/DC V3-COM: 15 to 150 V AC/DC V1-COM: 20 to 200 V AC/DC V1-COM: 30 to 300 V AC/DC V1-COM: 60 to 600 V AC/DC V1-COM: 6 to 60 mv AC/DC V2-COM: 10 to 100 mv AC/DC V3-COM: 30 to 300 mv AC/DC V1-COM: 1 to 10 V AC/DC V2-COM: 3 to 30 V AC/DC V3-COM: 15 to 150 V AC/DC V1-COM: 20 to 200 V AC/DC V1-COM: 30 to 300 V AC/DC V1-COM: 60 to 600 V AC/DC 200 to 500 VAC 200, 220, 230, or 240 VAC 380, 400, 415, or 480 VAC 200, 220, 230, or 240 VAC 380, 400, 415, or 480 VAC 200, 220, 230, or 240 VAC 380, 400, 415, or 480 VAC Thermocouple/Pt100 (0 to 399 C/ F) Thermocouple (setting unit of 10 C/ F) Thermocouple/Pt100 (0 to 399 C/ F) Thermocouple (setting unit of 10 C/ F) Supply voltage Same as the input voltage. 100 to 240 VAC 100 to 240 VAC Output relays Two SPDT relays Two SPDT relays Two SPDT relays Housing DIN 22.5 mm *1 2 can use standardized CT. *2 The K8AC-CT200L CT is required to use with 3. *3 K8AB-PH can detect the phase-loss during motor operation. 3

Model Number Structure K8AB-@@ 1 2 3 1. Basic Model Notation K8AB Meaning Measuring and Monitoring Relays 2. Functions Notation Meaning Operation Datasheet available AS Single-phase Current Relay One-sided operation Yes VS Single-phase Voltage Relay One-sided operation Yes VW Single-phase Upper-/lower-limit Simultaneous upper and Yes Voltage Relay lower limit PH Phase-sequence Phase-loss Relay --- Yes PM PA Three-phase Voltage Phase-sequence Phase-loss Relay Three-phase Asymmetry Phasesequence Phase-loss Relay 3. Rated Operating Power Note: For details, refer to the relevant Ordering Information. Simultaneous upper and lower limit Yes --- Yes PW Three-phase Voltage Relay Simultaneous upper and lower limit Yes K8AB-TH1@@ 2 3 4 2. Functions Notation Meaning Operation TH1 Temperature Device One-sided operation 3. Setting range Notation Meaning 1 Low temperature range (0 to 399 C set in increments of 1 C) 2 High temperature range (0 to 1700 C set in increments of 10 C) 4. Output form Notation S output Meaning 4

Application Examples Chain Breakage Protection for Conveyors 2 can use standardized CT!! Battery Voltage Checking K8AB-VS Foreign object Locked conveyor Motor CT Over current detection Instantaneous over current When the motor locks up, its rotational torque may break the chain. To prevent that from happening, the relay must trip the instant it detects a motor lock error. A thermal relay cannot be used for chain protection because it takes too long to start operating. The offers effective alarms because it starts operating in 0.1 s or less. (If a motor is used as the load, be careful that the inrush current does not exceed the allowable input range.) Battery The K8AB-VS is used to check battery charge levels. The K8AB-VS can detect when the battery charge is low. Monitoring the Control Power Supply at Communication Bases K8AB-VS K8AB-VW Protection against Idle Running of a Submersible Pump 2 can use standardized CT!! 220 VAC K8AB-VW Over and Under Voltage Monitoring Power supply 24 VDC Wireless communications base CT Under current detection Under current Voltage input level Power supply Submersible pump Idle pump operation Bulb Burnout Detection 2 can use standardized CT!! Under current Pump A submersible pump will malfunction if it begins to operate out of water, so instantaneous detection of this kind of idle operation is essential. The can detect idle pump operation by detecting under current levels. alarm indicator alarm indicator alarm relay alarm relay Flashing Communications bases must be carefully monitored because the effects of a power outage or voltage drop would be highly detrimental to communications. This is why the K8AB-VW monitors the control panel power supply for over voltage and under voltage levels. It can detect over voltage and under voltage as well as output individual over voltage and under voltage alarms using SPDT relays. T1 T Flashing Lit T Lit T: Operation time (0.1 to 30 s) T1: 1 s or 5 s selection (Timer when the control power supply is turned ON.) Under current detection Bulb External CT L L L L L The is used to detect burned out light bulbs. The can detect burned out light bulbs by detecting under current levels. The Relay's sensitivity can be adjusted to detect burned out light bulbs even in applications where multiple light bulbs are used. 5

Monitoring Phase Sequence/ Phase Loss for Escalators Can detect the phase-loss during motor operation!! K8AB-PH Monitoring Generated Voltage High voltage reception K8AB-PW Power grid panel OCR, RPR UVR, OVR Generator panel PLC K8AB-PH Phase-sequence and phase-loss Motor Contactor The K8AB-PH detects the phase sequence or phase loss in escalator power supplies. A single K8AB-PH can detect the phase sequence or phase loss at startup. Monitoring Compressor Power Supplies Fixed type Mobile type K8AB-PM Load Power grid protection relay K8ABA-PW 3-Phase voltage Generator The K8AB-PW monitors the voltage of power generated by a generator. It also detects over voltage and under voltage in power from a generator. A single K8AB-PW can monitor 3-phase voltage. It can also output individual alarms for over voltage and under voltage using SPDT relays because it features two outputs with SPDT relays. The voltage measurement range can be switched from 200 to 480 VAC and the K8AB-PW can be switched to monitor phase voltage or line voltage. Compressors cannot operate correctly under conditions such as under voltage, asymmetry voltage, phase loss, or phase sequence. The K8AB-PM can be used to monitor 3-phase voltage, the phase sequence, and phase loss. A single K8AB-PM can monitor over voltage, under voltage, the phase sequence and phase loss in 3-phase voltage. It can also output individual alarms for over voltage or under voltage using an SPDT relay. The K8AB-PM is able to recognize which alarm has occurred. Load 6 A at 250 VAC (resistive load) J7L Contactor K8AB-PM 3-Phase voltage, phase-sequence, and phase-loss Monitoring Voltage Generated by Wind-powered Generators L1 L2 L3 K8AB-PW The K8AB-PW detects over voltage and under voltage in power generated by a wind-powered generator. A single K8AB-PW can be used for a 3-phase power supply with 3 or 4 wires. It can be used to individually set and output over voltage and under voltage alarms. Wind-powered generator N K8AB-PW Simultaneous 3-phase over and under voltage The application examples provided in this catalog are for reference only. Check functions and safety of the equipment before use. Never use the products for any application requiring special safety requirements, such as nuclear energy control systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, or other application involving serious risk to life or property, without ensuring that the system as a whole has been designed to address the risks, and that the OMRON products are properly rated and installed for the intended use within the overall equipment or system. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. 6

Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ 2010.9 In the interest of product improvement, specifications are subject to change without notice. (c)copyright OMRON Corporation 2010 All Right Reserved.