USER MANUAL. Longo programmable controller LPC-2.CR1 Card Reader module. Version 5

Similar documents
USER MANUAL. Longo programmable controller LPC-2.CA1M Card Reader module. Version 2

USER MANUAL. Longo programmable controller LPC-2.CH1M Card Holder module. Version 3

USER MANUAL. Longo programmable controller LPC-2.AQ1 Air Quality module. Version 1

USER MANUAL. Longo programmable controller LPC-2.IR2V Multisensor. Version 4

USER MANUAL. Longo programmable controller LPC-2.ID2 RFID Card holder. Version 8

USER MANUAL. Longo programmable controller LPC-2.SM6 Multisensor. Version 4

USER MANUAL. Longo programmable controller LPC-2.MC8 Main module. Version 10

USER MANUAL. Longo programmable controller LPC-2.EO1 EnOcean Wireless module. Version 1

USER MANUAL. Longo programmable controller LPC-3.IOR.001 Input Output Relay PLC. Version 2

USER MANUAL. 7" Touch Screen LPC-2.PC2. Version 0

Transponder card reader

GENERAL BUILDING AUTOMATION CATALOGUE. Product Overview

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Table of Contents SMARTEH ACCESS SYSTEM DESCRIPTION SMARTEH ACCESS 2

Access Terminal IF-800

Transponder card holder

REX F-0-9 Standalone or Access Controller

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

LED W RGBA User Manual

GENERAL BUILDING AUTOMATION CATALOGUE. Product Overview

IF-80x Outdoor Terminal

MOXA EtherDevice Switch & PoE Splitter

Installation Instructions Model LFMWLT450, Class 1 Series AC-DC Power Supply

MODEL: R2K-1 SEN TRONIC AG. R2K Series

TB-1230 QW. User Manual Please read the instruc on carefully before use

USER MANUAL. RC-76R/RC-78R Room Controllers MODEL: P/N: Rev 2

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: RC-76R/RC-78R Room Controllers. P/N: Rev 5

Operating instructions. Speed monitor D / / 2014

Operating instructions. Switching amplifier DN0210 DN / / 2015

CP 64 BD15 CP 64 PD15

INJ-24A Series Quick Installation Guide

SAFETY PRECAUTIONS CAUTION WARNING CAUTION. Thank you for purchasing ig5a Series Profibus Communication Module

LED PANEL. User Manual Please read the instructions carefully before use LED-7TC. Innovation, Quality, Performance 15-

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

USER MANUAL. RC-43T Remote Controller MODEL: P/N: Rev 3

SAMURAI SCAN 50 LED-SC50D. User Guide. Innovation, Quality, Performance. Professional Entertainment Technology 19-

USER MANUAL. RC-74DL Master Room Controller MODEL: P/N: Rev 4

Agilent 70612B K18 Switch Matrix

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions

GV-Card Reader. User s Manual

LED PANEL. User Manual Please read the instructions carefully before use LED-212RGB TABLE OF CONTENTS. 1. Safety Instructions

Communication Interface for SMA Inverters SMA BLUETOOTH PIGGY-BACK

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

GB DC ADAPTER OWNER'S MANUAL CHINA

USER MANUAL. RC-43SL 6-Button Room Controller MODEL: P/N: Rev 3.

QUINT-BUFFER/24DC/24DC/40

1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

MS-5000: MiniStar Reader

Industrial RFID Reader

UV Power Flood. User Manual. Order code: EQLED029

MS-5000 MiniStar Reader. Quick Start Guide MS The MS-5000 MiniStar Reader. 1.0 Specifications

MS-7000: SuperStar Reader

EL1142 Series. IEC / IEEE 1613 Hardened 2-Port 10/100BASE-TX to 2-Port 100BASE-FX Media Converter. User s Guide

LTK1100 Series Card Reader User Manual

SCHOTT FLM 4 Fiber Lighting Modul. Operating Instructions

Firmware Guide. Keysight PXIe Chassis Family

Professional Entertainment Technology. imove 50SR. Innovation, Quality, Performance 21-

User Manual. Printer P-52RUE

Blitzer Strobe. User Manual. Order code: EQLED366

5 B&W Rear View System Camera

Stand-alone Proximity Access Control

LED BEAM 300 LED-MB50. User. Guide. Professional Entertainment Technology

Professional Entertainment Technology LED BEAM 300 LED-MB50. Innovation, Quality, Performance 23-

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: RC-74DL Master Room Controller. P/N: Rev 5

Serial PROFIBUS Interface

Fingerprint and Card Reader User Manual

_ Access control SISTEMAS DE SEGURIDAD

Professional Entertainment Technology LED BEAM 300 LED-MB50. User. Guide

RТTH DUAL ROOM SWITCH

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

USER MANUAL RC-76M/RC-712M MODEL: P/N: Rev 3

Neets Control EcHo Plus. Installation Manual

CM E FUJITSU SEMICONDUCTOR CONTROLLER MANUAL F 2 MC-16L/16LX EMULATION POD MB HARDWARE MANUAL

S125 Multi-Purpose 125 KHz RFID Reader USER MANUAL. 9V/24V DC Operating Voltage, AC (optional) KHz RFID EM4100/2 Cards & Tags

MGate 4101-MB-PBS Series

RXTH DUAL ROOM SENSOR / SWITCH

Gobo Projector XP 80W

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

PHOENIX CONTACT - 07/2006

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.

Kvaser Linx J1587 User's Guide

Manual Version: V1.00. Video Decoder Quick Guide

MATRIX LED LED User Manual Please read the instructions carefully before use

MGate 5102-PBM-PN Series

IKS-G6524A/G6824A Series Quick Installation Guide

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

USER MANUAL. SL-10 Master Room Controller MODEL: P/N: Rev 4

CONTENTS PRODUCT FEATURES... EG-2 SAFETY PRECAUTIONS... EG-2 PARTS DESCRIPTION... EG-3 INSTALLATION AND ADJUSTMENT... EG-4 SPECIFICATIONS...

General Specifications

MINI-PS AC/10-15DC/8

USER MANUAL. RC-43SL 6-Button Room Controller MODEL: P/N: Rev 1.

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

Wiring Instructions v4

38 MHz Passive Voltage Probe R&S RT-ZP1X

IMC-21 Quick Installation Guide

Transcription:

USER MANUAL Longo programmable controller LPC-2.CR1 Card Reader module Version 5 SMARTEH d.o.o. / Poljubinj 114 / 5220 Tolmin / Slovenia / Tel.: +386(0)5 388 44 00 / e-mail: info@smarteh.si / www.smarteh.si

Written by SMARTEH d.o.o. Copyright 2016, SMARTEH d.o.o. User Manual Document Version: 005 June, 2016 i

STANDARDS AND PROVISIONS: Standards, recommendations, regulations and provisions of the country in which the devices will operate, must be considered while planning and setting up electrical devices. Work on 230 V AC network is allowed for authorized personnel only. DANGER WARNINGS: Devices or modules must be protected from moisture, dirt and damage during transport, storing and operation. WARRANTY CONDITIONS: For all modules LONGO LPC-2 if no modifications are performed upon and are correctly connected by authorized personnel in consideration of maximum allowed connecting power, we offer warranty for 24 months from date of sale to end buyer. In case of claims within warranty time, which are based on material malfunctions the producer offers free replacement. The method of return of malfunctioned module, together with description, can be arranged with our authorized representative. Warranty does not include damage due to transport or because of unconsidered corresponding regulations of the country, where the module is installed. This device must be connected properly by the provided connection scheme in this manual. Misconnections may result in device damage, fire or personal injury. Hazardous voltage in the device can cause electric shock and may result in personal injury or death. NEVER SERVICE THIS PRODUCT YOURSELF! This device must not be installed in the systems critical for life (e.g. medical devices, aircrafts, etc.). If the device is used in a manner not specified by the manufacturer, the degree of protection provided by the equipment may be impaired. Waste electrical and electronic equipment (WEEE) must be collected separately! LONGO LPC-2 complies to the following standards: EMC:EN 61000-6-2 (EN 50082), EN 61000-6-4 (EN 50081) LVD: IEC 61131-2 Vibrations and climatic-mechanical: EN 60068-2-6, EN 60068-2-27, EN 60068-2-29 Smarteh d.o.o. operates a policy of continuous development. Therefore we reserve the right to make changes and improvements to any of the products described in this manual without any prior notice. MANUFACTURER: SMARTEH d.o.o. Poljubinj 114 5220 Tolmin Slovenia ii

1 ABBREVIATIONS...1 2 DESCRIPTION...2 3 FEATURES...3 4 OPERATION...4 4.1 Parameters...4 5 INSTALLATION...5 5.1 Connection scheme...5 5.2 Mounting instructions...7 5.3 Module labeling...8 6 TECHNICAL SPECIFICATIONS...9 7 SPARE PARTS...10 8 CHANGES...11 9 NOTES...12 iii

1 ABBREVIATIONS Sorted by order of appeareance in document: RFID Radio frequency identification SOS Emergency call LED Light emitting diode DIP Dual in-line package ID Identity MCU Main control unit 1

2 DESCRIPTION LPC-2.CR1 RFID reader is intended to be used as an identity verification device for room, office or other indoor entrance. When RFID tag (key-card) is approached to the reader and its code is successfully read out, the green LED blinks and a short beep is generated. In case key-card for correspondent room is valid, the green LED blinks again and a short beep is generated. Other devices can be activated at this event like door lock opening, turning light on... If key-card number is not valid, the red LED blinks and a longer beep is generated. Functionalities are controlled from MCU. Controller is accompanied with Smarteh IDE application. It is a tool, where various modules can be put together to a configuration, based on number and type of electrical signals needed. Smarteh IDE takes care for proper modules position. Latest Smarteh IDE setup can be downloaded from Smarteh web page support section: www.smarteh.si/support/downloads/software/development_tools LPC-2.CR1 module can be modified on customer request: custom front label, push buttons added, LEDs added. For more information please contact manufacturer. 2

3 FEATURES Figure 1: LPC-2.CR1 module. Table 1: Technical data RFID reader OK LED Fault X LED Power LED Internal fault LED Internal built-in buzzer Black or white glass possibility 3

4 OPERATION Operation of the CR1 module is also dependent on parameters received on RS-485 communication channel. Reader RFID field is active always when module is powered up. If tag is put inside RFID field, reader tries to resolve RFID tag code. If code is read successfully, module activates status iidnew, generates a short beep, OK LED1 blinks and code is transmitted in iidw1 - iidw3 status fields. In MCU application this code can be read out and authenticated. If code has appropriate rights, MCU should activate ook command. If code is not authorized, MCU application should activate ofault command. Regarding command received, following action are triggered on module: ook --> OK LED2 blink, short beep. ofault --> Fault LED1 blink, long beep. Either command is received or no command is received within 10 sec, module clears iidnew status and waits for next RFID tag. While CR1 module is waiting for authorization response, new RFID tags can not be read. 4.1 Parameters If parameter is set to logical 1, is considered to be active, enabled or set. If parameter has logical value 0 is considered to be inactive, disabled, or cleared. Parameter can be feedback or command. Parameter as feedback means that CR1 module is sending information to MCU. On the other hand, command represents request from MCU to module. Command: ID Fault [ofault]: Command for rejecting authorization of RFID code. ID OK [ook]: Command for authorization of RFID code. Buzzer [obuzz]: While this command is active, buzzer is active. 'Fault' ID LED [ofaultld]: While this command is active, fault LED1 is set. 'OK' ID LED [ookld]: While this command is active, OK LED2 is set. Card Type Select [oseltyp]: 0 Emarine; 1 hitag. Feedback: RFID ID Word1 [idw1]: Upper (most significant) third of RFID code. RFID ID Word2 [idw2]: Middle third of RFID code. RFID ID Word3 [idw3]: Lower (least significant) third of RFID code. New ID [iidnew]: When new RFID tag is recognized, this status is set active for 10sec or till authorization command is received (ook or ofault). Communication [icomm]: Normal state is 0. If set, there is communication error or no communication established. 'Up-right' TB [iuprtb]: signal from button located up-right corner (this button is disabled by default and can be enable in EPROM). 'Up-left' TB [iupltb]: signal from button located up-left corner (this button is disabled by default and can be enable in EPROM). 4

5 INSTALLATION 5.1 Connection scheme Figure 2: Connection scheme 5

Table 2: K1 K1.1 GND Ground K1.2 10.. 24 V DC Power supply input K1.3 RS-485 A Data receive/send line A K1.4 RS-485 B Data receive/send line B Table 3: LEDs & Buttons LED1: red Fault X ON: RFID key standard NOK or ID card number wrong OFF: No tag in proximity LED2: green OK ON: RFID key standard OK and ID card number valid OFF: No tag in proximity LED5: red Communication ON: RS-485 communication fault OFF: RS-485 communication OK LED6: green Power supply ON: power supply OK OFF: power supply missing or power off Table 4: S1 RS-485 ADDRESS Switch 1 Switch 2 0 OFF OFF 1 OFF ON 2 ON OFF 3 ON ON 6

5.2 Mounting frame selection Frame, suitable for CR1 module insertion, should be modular one at least 3 gang wide. Be careful to have corresponding flush-mounting box provided on the place where module will be positioned. Smarteh has verified following lines to be compatible with LPC-2.CR1 module: Bticino Living, Light Gewiss Playbus, System Vimar Plana, Idea Tem Modul Soft, Modul Line Master Frames of other vendors most probably suits as well, but they were not verified by Smarteh. Before installation verify compatibility of non listed frames. Module housing has a fin on each side, which can be easily removed with knife cutter or pliers. This adaptation enables housing to be build in various frame formats with two different depths. With regard to frame used you may remove fin for housing to fit in. Figure 3: Removable fin. 7

5.3 Mounting instructions Figure 4: Housing dimensions Dimensions in millimeters. All connections, module attachments and assembling must be done while module is not connected to the main power supply. Several RFID panels should not be mounted close to each other. Minimum distance to next panel is at least 30 cm. This restriction also applies in case of mounting panels on both sides of the same wall. Adequate shielding material and provisions could be used to avoid interference between panels. Mounting of RFID panels into conductive, metal frames, is not allowed. RFID panel should not be positioned close to conductive areas. 1. Set the correct RS-485 address (S1 switch) for LPC-2.CR1 (refer to the Table 4). 2. Connect interconnection cable to the connector K1. Max. allowed tractive force is 30 N. 3. Mount LPC-2.CR1 module on provided. 4. Cover LPC-2.CR1 with cover plate. LPC-2.CR1 connects to the MCU unit on its RS-485 port using interconnection cable. When more special modules (e.g. LPC-2.CA1, LPC-2.CH1, LPC-2.DP1) are connected to MCU, splitter is also required (e.g. SPL-2). Signal wires must be installed separately from power and high voltage wires in accordance with general industry electrical installation standard. 8

5.4 Module labeling Table 5: Labels on housing Label 1 (sample): Label 2 (sample): LPC-2.CR1 P/N:225CR110V01001 D/C: 01/10 S/N: CR1-S9-1000000003 Label 1 descriptions: 1. LPC-2.CR1 is the full product name. 2. P/N: 225CR110V01001 is the part number. 225 general code for product family, CR1 short product name, 10V01 sequence code, 10 year of code opening, V - denotes flush frame mounting module, 01 derivation code, 001 version code (reserved for future HW and/or SW firmware upgrades). 3. D/C:01/10 is the date code. 01 week and 10 year of production. Label 2 descriptions: 1. S/N: CR1-S9-1000000003 is the serial number. CR1 short product name, S9 user code (test procedure, e.g. Smarteh person xxx), 1000000003 year and current stack code, 10 year (last two cyphers), 00000003 current stack number; previous module would have the stack number 00000002 and the next one 00000004. 9

6 TECHNICAL SPECIFICATIONS Table 6: Technical specifications Power supply from MCU Interconnection connector type RJ-12 6/6 Power consumption 1.5 W RFID type EM4100, 125 khz, Manchester 64, read only HITAG2 UID, read only Max. reading distance 4 cm Dimensions (W x H x D) 75 x 49 x 29 mm Weight 40 g Ambient temperature 0 to 50 C Ambient humidity max. 95 %, no condensation Maximum altitude 2000 m Mounting position horizontal Transport and storage temperature -20 to 60 C Protection class IP 20 10

7 SPARE PARTS For ordering spare parts following Part Numbers should be used: LPC-2.CR1 Card Reader module LPC-2.CR1, EM, black P/N: 225CR109V01001 LPC-2.CR1 Card Reader module LPC-2.CR1, EM, white P/N: 225CR115V01W01 LPC-2.MC8 Main module LPC-2.MC8 P/N: 225MC813001001 Splitter SPL-2 (1/8) P/N: 206SPL04002001 Interconnection cable ICM-x P/N: 203ICMxxxxxxxx 11

8 CHANGES The following table describes all the changes to the document. Date V. Description 07.06.2016 5 General update. 01.06.2014 4 Power consumption data update. 01.02.2013 3 Technical update. 01.07.2012 2 CGP General update. 18.03.2010 1 The initial version, issued as LPC-2.CR1 module UserManual. 12

9 NOTES 13