IPaCS Equipment Overview Modular Panelboard System Integrated Power Center Integrated Power Center

Similar documents
IPaCS Equipment Overview Integrated Power Center (IPC) Integrated Power Center 2 (IPC2 ) 10-4

2015 $22. Digest 177. digestplus-us.schneider-electric.com

Power-Style QED-2, Series 2 Low Voltage Switchboards

Switchboards. Product Overview

Internal Modular SPDs

PanelFAST. Setting a new standard for immediate product availability with Square D Ready to Install (RTI) Panelboards

Integrated Equipment Solutions

PDI Modular Compact Remote Power Panel

9.3. Metering Devices, Protective Relays, Software and Connectivity

I-Line Panelboards. Innovative design, smart bus technology, and simple installation

Powering innovation. Powering efficiency. Powering home

SECTION SWITCHBOARDS

Square D Homeline Load Centers and Circuit Breakers. Engineered for value

4.3. Switchboards. Contents Description Pow-R-Line Drawout Molded Case Circuit Breaker Switchboards Product Selection...

GE Energy Connections. EntellEon * Low Voltage Power Panel. Simple. Responsive. Revolutionary.

i-3 Control Technology

Zenith Series MDU & RDU. Critical Power Distribution Units

PowerPak 2 Power Distribution Unit. Flexible. Configurable. Intelligent. Safe.

Surgelogic. Surge Protective Devices (SPDs) Residential. Catalog 6671CT9701R08/

PowerLogic EM4000 series

White Paper. UL Standards for Power Control System Equipment

ASCO SERIES 300 Manual Transfer Switch Solutions

Section 6. Surge Protective Devices (SPDs) Table of Contents. Externally Mounted Surge Protective Devices

SECTION PANELBOARDS

Configurable power distribution

BSPD Surge Protective Devices

Power Xpert Branch Circuit Monitor

Integration Fully integrated Controls, Power Monitoring, Generator Paralleling, and Switching Schemes as a complete turnkey solution.

Transfer Switches 5.1 Transfer Switch Equipment Product Selection Guide... Product Description... Application Description...

Target Interface / Construction Compliance Inspection Checklist

From houses to high-rises

15U Wall-Mount Server Rack Cabinet - 20 in. Deep - Hinged

SECTION PANELBOARDS. A. NECA (National Electrical Contractors Association) -Standard of Installation

alid portable power cart epcc panel ccts EPCC-60 40" 60A, 120/208V 3PH 24 EPCC " 100A, 120/208V 3PH 24

SECTION TRANSIENT VOLTAGE SURGE SUPPRESSION

I-Line SPDs Square D TM Internally Mounted Surge Protective Devices

SECTION ( ) LIGHTING CONTROL PANELBOARD

920 Remote Control (RC) Switches

ICS Entrance Management Sign Installation Guide. Version 1.0

These specifications describe requirements for a power distribution unit (PDU) distributing power to sensitive loads.

C. New or replacement products installed in existing facilities shall be consistent with existing equipment.

Section 5. Lighting Controls. Table of Contents. Powerlink Integrated Control Systems. Powerlink Energy Management 5-6

SECTION TRANSIENT VOLTAGE SUPPRESSION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS

MiniEVR Electronic Voltage Regulator-Power Conditioner (MEVR)

4C Standard Horizontal Mailboxes

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

Square D QO Load Centers and Circuit Breakers. The leader for safe, reliable, and innovative solutions

Quick Start Installation Guide

SECTION ELECTRIC METERING

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2

Featuring Spectra RMS Breakers

PRODUCT BROCHURE. Cyberex Remote Power Panel (RPP) Power distribution system

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

PowerLogic High Density Metering System 1-Meter Enclosure

Zenith Series DPB. Distributed Power Busway

ASCO 920 Remote Control (RC) Switches

PowerPak Power Distribution Unit

SECTION SURGE PROTECTION DEVICES. A. Section includes Surge Protection Devices for low-voltage power, control, and communication equipment.

Target Interface / Construction Compliance Inspection Checklist

Hubbell Surge Protective DeviceS

Product brochure. Cyberex. Remote Power Panel (RPP) Power distribution system

Custom Switchracks: Built to Comply with NEC/CEC Standards From Design to Installation, Appleton is The Switchrack Authority

Series Amp Pad Mount Quick Connect Input and Output Power Panels

SECTION DISTRIBUTION SWITCHBOARDS

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

White Paper Avoiding SPD Procurement Errors

SECTION 16450: NON-AUTOMATIC TRANSFER SWITCH / QUICK CONNECT GENERATOR SWITCHBOARD <S> <OM>

A Scalable, Reconfigurable, and Efficient High Density Data Center Power Distribution Architecture

POWER DISTRIBUTION

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

SPOS (Station Point of Sale) 200. SFTP (Station Fare Transaction Processor) 35. CQD (Card Query Device) 35. HCR (Handheld Card Reader) Cradles 120

CANADIAN CATALOG JANUARY SENTRICITY Loadcentres and Circuit Breakers Raising the standard in residential.

Metal-enclosed interrupter 5 kv-15 kv usa.siemens.com/siebreak

Surgelogic Surge Protective Device I-Line Plug-On Unit Series

Pow-R-Command 2000 System Overview

US Catalog July 2016 SMISSLINE TP

Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories

2013 ESL Power Systems, Inc. All Rights Reserved.

Application Techniques CENTERLINE 2100 Motor Control Centers

Target Interface / Construction Compliance Inspection Checklist

DATACOM CABINETS SOLUTION GUIDE

Simple Electrical Utility Cost Allocation Solutions

TSC Schneider-PDI Agenda

Target Interface / Construction Compliance Inspection Checklist

4C Std Horizontal Mailboxes - cont. on pgs 14-19

Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories

Installation Manual. APEX Series. Silicon and MOV Panel Protection. APEX Series

Target Interface / Construction Compliance Inspection Checklist

Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories

Liebert TVSS: The First Line of Defense - Product Overview. Jim Tiesi

AcquiSuite Ally 48 Advanced Branch Circuit Monitor

MIL STD 220a (50 Ohm) Model Ordering: 400LS - 277Y - DS - UFP - MX

7000 SERIES Power Switching Solutions. Closed Transition Transfer Switching. Delayed Transition Transfer Switching

Maximum Reliability & Excellent Value. Features. UL Listed Withstand & Close-On Ratings. Series 300 Power Transfer Switches

DANGER DANGER: is used in this manual to warn of high voltages capable of causing shock, burns, or death.

Flat Screen Garage. Table System Planning Guide WORKING FOR YOU

Overview These instructions are presented as a guideline for installing and setting up the LX Series Breaker Control Panel.

QuickSpecs. HP Intelligent Power Distribution Unit (ipdu) Overview

Electrical Demand Specification (Reference SOP: )

The Leviton Load Center THE FUTURE MADE CURRENT

Transcription:

Table of Contents Section 0 Integrated Power and Control Solutions (IPaCS) Equipment IPaCS Equipment Overview 0- Modular Panelboard System 0-3 Integrated Power Center 0-3 Standby Power Connection Solutions 0-4 Submetering Integrated Power Center 0-4 MPS, see page 0-3 Integrated Power Center 0-4 Integrated Power Center 0-4 Integrated Power Center Transformer Combo 0-5 Integrated Power Center Transformer Combo 0-5 Merchandise Specifications Integrated Power Center Transformer Combo 0-6 Merchandise Configurations IPC, see page 0-3 IPC, see page 0-4 0 Schneider Electric 0- This document provided by Barr-Thorp Electric Co., Inc. 800-473-93 www.barr-thorp.com

IPaCS Equipment Overview Class 00 / Refer to Documents 30DB060, 00CT000, and 735CT000 www.schneider-electric.us Integrated Power and Control Solutions Equipment Overview For over 30 years, the Schneider Electric Integrated Power and Control Solutions (IPaCS ) business has been providing integrated equipment solutions for retail construction, commercial, and industrial projects. The Square D brand IPaCS family of integrated equipment combines electrical distribution, building controls, and automation into a single, factory-assembled and pre-wired enclosure/lineup. Our innovative, cost-effective, integrated solutions save valuable floor space, shorten construction cycle times, and reduce installation and material handling costs. Modular Panelboard System Pre-Engineered Solution The Modular Panelboard System (MPS) is tailored to customer specifications and may include panels, transformers, and lighting control equipment. Special Powerlink lighting control and column-width panel interiors are available. Additional options include power and control cable wiring, contactors, terminal blocks, surge protective devices (SPDs), equipment spaces, and power metering/monitoring solutions. Seismically qualified MPS sections are also available. Tailored to customer specifications, MPS sections are: 86 in. (84 mm) high, 9.5 in. (4 mm) deep, and vary in width depending on customer specifications Integrated Power Center Custom-Designed Solution For more complex applications, the Integrated Power Center (IPC) allows for the integration of a variety of components, including electrical distribution equipment, HVAC controls, lighting controls, power quality and power conditioning products, SPDs, building management systems and power metering/monitoring solutions. As with all IPaCS integrated solutions, the IPC is designed to meet applicable codes and standards and is available as seismically qualified. Factory-assembled, pre-wired (based on shipping splits), and tested in a controlled environment, IPC sections are: 84 in. (34 mm) high, 0.5 in. (67 mm) deep, and vary in width depending on customer specifications Standby Power Connection Solutions UL Listed The new family of Standby Power Connection Solutions are designed, tested, manufactured and listed to the UL standards providing you with a reliable solution to quickly and safely connect to a portable generator for standby power. The SPQ cam-lock (SPQCL) tap box design incorporates cam-lock receptacles for generator connection and the capabilities to be wired back to the standby power disconnect in the electrical distribution equipment. The SPQ lug-lug (SPQTB) tap box provides the capabilities to connect to a portable generator and the generator breaker cables using mechanical lugs in lieu of the cam-lock connectors. The SPQ Cam-Lock Box is: 36 in. (95 mm) high 30 in. (76 mm) wide 6 in. (407 mm) deep The SPQ Lug-Lug Box is: 36 in. (95 mm) high 30 in. (76 mm) wide 3 in. (330 mm) deep Submetering Integrated Power Center The Submetering Integrated Power Center (IPC) is an ideal solution for multi-tenant or departmental metering applications within office towers, condominiums, apartment buildings, shopping centers, and other multi-user environments. The Submetering IPC combines the panel with breakers, the PowerLogic E4800 multi-circuit energy meter and the associated CTs in a factory-assembled and pre-wired solution saving significant space and on-site installation time. Submetering IPC sections are: 0.5 in. (67 mm) deep, and vary in width and height depending on the application Integrated Power Center The newest addition to the family of Integrated solutions, the Integrated Power Center (IPC ) provides maximum flexibility to meet customers' specifications. Features include those found in the IPC and are provided in a free-standing enclosure that can be front and rear aligned when transformers are included. The IPC family is available as seismically-qualified. Enclosure options include NEMA, NEMA with driphood and NEMA 3R. IPC sections are: (34 mm) high, and vary in width and depth depending on customer specifications NOTE: Additional depths are available. Contact the Schneider Electric Integrated Power and Control Solutions business (-800-868-966) for more information.) Integrated Power Center Transformer Combo Ideally suited for projects having both 480Y/77V and 08Y/0V requirements. Available as a stand-alone solution or can be incorporated into an MPS, IPC or IPC lineup. The standard 4" wide x 4" deep footprint will decrease space requirements by 40% or more. A typical IPC Transformer Combo includes two panels in the upper cells and a transformer in the bottom cell. Other upper cell options include contactors, individually mounted circuit breakers, ATS's, equipment spaces and power metering/monitoring solutions. The IPC Transformer Combo is available as seismically qualified.enclosure options include NEMA, NEMA with driphood and NEMA 3R. IPC Transformer Combo sections are: (34 mm) high, and vary in width and depth depending on the transformer kva Additional savings are realized on installation, material costs and material handling, as shown in the table below. Table 0.: IPC Transformer Combo Estimated Savings a Stick-Built Transformer Combo Savings Realized Estimated Installation Hours 6 3 3 6 3 6 Materials Associated pipe, wire and fittings Associated pipe, wire and fittings No. of Pieces Handled 0 30 9 9 a Based on an NF 480 V panel, 75 kva transformer, NQ 40 V panel installation. The IPC Transformer Combo has been recognized by the electrical industry by winning the following awards: 006 INNOVATION Award given by the Electrical Contracting Products magazine 006 Product of the Year Gold Medal Award given by the Consulting/Specifying Engineer magazine 0-0 Schneider Electric This document provided by Barr-Thorp Electric Co., Inc. 800-473-93 www.barr-thorp.com

www.schneider-electric.us IPaCS Equipment Modular Panelboard System and Integrated Power Center Modular Panelboard System Class 0, 0 / Refer to Documents 00CT000 and 735CT000 The pre-engineered Modular Panelboard System (MPS) bundles electrical distribution equipment into a single factory-assembled and wired integrated system. This approach replaces the traditional method of independently mounting each panelboard and lighting control system. MPS allows for the integration of a variety of components including: Panelboards: I-Line, NF, NQ, and Column-width Surge Suppression: SPD integral to panel and/or separately mounted Lighting Controls: Powerlink or lighting contactors Monitoring/Metering: Powerlogic power meters, circuit monitors, branch circuit monitoring, and system display meters Equipment spaces including factory-installed lighting contactors are available in three configurations:. Unwired: Mounted in cell only. Line side wired: Line side of each pole is wired to a branch circuit breaker 3. Fully wired: Line side of each pole is wired to a branch circuit breaker, load side of each pole is wired to a terminal block Modular Panelboard System MPS Interior Built on a panelboard platform, Modular Panelboard System sections are NEMA -rated and meet the requirements of UL 67. Individual MPS configurations include panel sections in full-height, stacked or side-by-side arrangements. Individual sections measure: 86 in. (84 mm) high 0 44 in. (54 8 mm) wide 9.5 in. (4 mm) deep Typical applications for MPS equipment include: Restaurants / Food service Office buildings / Public buildings Warehouses Schools / Universities Integrated Power Center The custom-designed Integrated Power Center (IPC) combines electrical distribution equipment and building management controls into a single factory-assembled and wired integrated system. IPC has much greater design flexibility for producing a fully customized solution integrating a variety of distribution and control components, including: Panelboards: I-Line, NF, NQ, and Column-width Surge Suppression: SPD integral to panel and/or separately mounted Lighting Controls: Powerlink or lighting contactors Monitoring/Metering: Powerlogic power meters, circuit monitors, branch circuit monitoring, and system display meters Power quality and power conditioning Building automation HVAC controls Equipment spaces including factory-installed lighting contactors are available in three configurations:. Unwired: Mounted in cell only. Line side wired: Line side of each pole is wired to a branch circuit breaker 3. Fully wired: Line side of each pole is wired to a branch circuit breaker, load side of each pole is wired to a terminal block Integrated Power Centers are NEMA rated and meet the requirements of UL 89. As with all integrated solutions, IPCs are shipped to the site fully assembled, completely pre-tested and ready-to-install. Individual IPC configurations include panel sections in full height, stacked, or side-by-side arrangements. IPC sections measure: 84 in. (34 mm) High 0.5 (60 mm) Deep Widths vary, depending upon customer specifications Integrated Power Center Typical applications for IPC equipment include: Retail stores / Grocery stores Office buildings / Public buildings Shopping malls / Strip malls Schools/Universities Restaurants / Food service Hotels/Motels Warehouses Equipment rooms MPS and IPC Layout, Lead Time, and Pricing Contact your local Schneider Electric representative or distributor. 0 Schneider Electric IPC Interior MPS and IPC Shipping MPS and IPC lineups are shipped factory-assembled and pre-wired. Customers may specify single- or multiple-section shipping splits (some limitations apply). In addition, lineups may be ordered with or without factory-installed power cables. This document provided by Barr-Thorp Electric Co., Inc. 800-473-93 www.barr-thorp.com 0-3

IPaCS Equipment SPQ Cam-Lock Tap Box SPQ Lug-Lug Tap Box Integrated Power Center (IPC ) Class 30 / Refer to Documents 30HO060 and 30DB060 www.schneider-electric.us Standby Power Connection Solutions The Standby Power Quick-Connect (SPQ) Tap Box provides a reliable solution to quickly and safely connect to a portable standby power generator. Two versions of the SPQ Tap Box have been designed and tested to the required UL standard and offer a wider range of solutions for our customers. All SPQ Tap Boxes are NEMA 3R-rated. SPQ Cam-Lock Tap Box UL listed - UL 008 SB NEMA Type 3R enclosure (can be used for NEMA Type installations) Lockable door for safety and control access Mechanical lugs to standby power disconnect Color-coded cam-lock connectors for generator connection Hinged bottom access door for cam-lock connection Barriers over mechanical lugs for safety Application: 400 A and 600 A available 40 V and 480 V versions available Three-phase + neutral + ground SPQ Lug-Lug Tap Box UL listed UL 773 (cul listed also) NEMA Type 3R enclosure (can be used for NEMA Type installations) Lockable door for safety and control access Mechanical lugs to standby power disconnect Generator connection lugs rated for Type W cable Application: 400 A and 800 A available 600 V maximum Three-phase + neutral + ground Submetering Integrated Power Center The Submetering Integrated Power Center (IPC) is an ideal solution for multi-tenant or departmental metering applications. It combines the ability to meter multiple feeder breakers inside a pre-wired enclosure. The Submetering IPC offers significant space and labor savings by replacing individually enclosed, mounted, and wired panels and metering components and providing an integrated solution in one enclosure/lineup including: Panelboards PowerLogic E4800 Multi-Circuit Energy Meters and associated CTs Surge Suppression Factory-installed wiring between components Submetering IPC width and height dimensions vary depending on the application. All sections are 0.5 in. (66.7 mm) deep. Typical applications for Submetering IPC equipment include: SPQCL04RS 400 A, 08Y/0 V SPQCL404RS 400 A, 480Y/77 V SPQCL06RS 600 A, 08Y/0 V SPQCL406RS 600 A, 480Y/77 V SPQTB604RS 400 A, 600 V max. SPQTB608RS 800 A, 600 V max. Office towers Condominiums Apartment buildings Shopping centers Other multi-user environments Configurations with -PowerLogic E4800 meters plus Ethernet switch when required based on the number of metered points Submetering Integrated Power Center Integrated Power Center The Integrated Power Center (IPC ) provides maximum design flexibility. In addition to the features found in the Integrated Power Center (IPC), IPC lineups are free-standing enclosures that can be front and rear-aligned. IPC has the ability to incorporate: Panelboards: I-Line, NF, and NQ Transformers: 300 Kva (max), EE K-rated and HMT also available; may limit max kva size of transformer Individually mounted circuit breakers Surge Suppression: SPD integral to panel and/or separately mounted Automatic Transfer Switch: Open type 400 A 3-pole maximum including a variety of options Lighting Controls: Powerlink or lighting contactors PowerLogic Monitoring / Metering: power meters, circuit monitors, branch circuit monitoring, and system display meters Building Management Systems As a stand-alone solution, the IPC family provides the flexibility to enter and/or exit the section from either the top or bottom. IPC is offered in a variety of widths and depths: 4 48 in. (60 9 mm) Wide 4 36 in. (60 95 mm) Deep Typical applications for IPC equipment include: Schools/Universities Office buildings Data centers Industrial facilities Casinos Hotels Any project with panels and transformers Integrated Power Center ICP Layout, Lead Time, and Pricing Contact your local Schneider Electric representative or distributor. IPC Shipping IPC lineups are shipped fully assembled and ready-to-install. Customers may specify single- or multiple-section shipping splits (some limitations apply). In addition, lineups may be ordered with or without factory-installed power cables. 0-4 0 Schneider Electric This document provided by Barr-Thorp Electric Co., Inc. 800-473-93 www.barr-thorp.com

www.schneider-electric.us IPaCS Equipment Integrated Power Center (IPC ) Class 30 / Refer to Documents 30HO060 and 30DB060 Integrated Power Center Transformer Combo For projects having both 480Y/77 V and 08Y/0 V requirements, the Integrated Power Center (IPC) Transformer Combo is the perfect solution. One of the most popular members of the IPC product family, the IPC Transformer Combo has been recognized by the industry multiple times for its innovative design. As a stand-alone solution, the IPC Transformer Combo is appropriate when panelboards and transformers are installed in close proximity to each other. It provides the flexibility to enter and/or exit the section from either the top or the bottom. Catalog numbers have been created for some of the more typical configurations (see Table 0.). All IPC sections can be close-coupled to QED switchboard, MPS, and IPC products. Enclosure options for IPC include NEMA, NEMA with driphood, and NEMA 3R-rated, and all meet the requirements of UL 89. These sections are also seismically qualified to meet IBC and ASCE7 requirements. IPC Transformer Combo Table 0.: Catalog No. IPCTC-EE IPC Transformer Combo Merchandise Configuration Specifications 480Y/77 V 3Ø 4W 5/3 MB 8 k AIC 5/3 MB 0 k AIC 75 kva 5/3 (Transformer) 39-PSO Catalog No. IPCTC-EE 480Y/77 V 3Ø 4W 400 A MLO 8 k AIC 5/3 MB 0 k AIC 75 kva 5/3 (Transformer) 39-PSO Catalog No. IPCTC-3EE NQ Panelboard NQ Panelboard Transformer 08Y/0 V 3Ø 4W 5/3 MB 0 k AIC 5 A MLO 0 k AIC 75 kva FT Lugs Catalog No. IPCTC-4EE 480Y/77 V 3Ø 4W 400 A MLO 8 k AIC 400/3 MB 0 k AIC ½ kva 75/3 (Transformer) 30-PSO Catalog No. IPCTC-5EE 480Y/77V 3Ø 4W 08Y/0V 3Ø 4W 480V-08Y/0V 3Ø 400/3 MB 8k AIC 5/3 MB 0k AIC 75kVA -5/3 (Transformer) 7-PSO Copper Bus/Ground Bus 50 C Temp Rise Copper Bus/Ground Bus Catalog No. IPCTC-6EE NF Panelboard NQ Panelboard NQ Panelboard Transformer 480Y/77 V 3Ø 4W 08Y/0 V 3Ø 4W 5/3 MB 8 k AIC 5/3 MB 0 k AIC 5 A MLO 0k AIC 75 kva 5/3 (Transformer) 39-PSO FT Lugs Catalog No. IPCTC-7EE 480Y/77 V 3Ø 4W 5 A MLO 8 k AIC 5/3 MB 0 k AIC 45 kva 60/3 (Transformer) -PSO 5-PSO Catalog No. IPCTC-8EE 480Y/77 V 3Ø 4W 5 A MLO 8 k AIC 00/3 MB 0 k AIC 30 kva 40/3 (Transformer) 5-PSO 5-PSO 0 Schneider Electric This document provided by Barr-Thorp Electric Co., Inc. 800-473-93 www.barr-thorp.com 0-5

IPaCS Equipment Sample Lineups Class 00 / Refer to Documents 30DB060 and 00CT000 www.schneider-electric.us Integrated Power Center Transformer Combo Standard Merchandise Configurations The IPC Transformer Combo is available in eight standard merchandise configurations, as shown below (additional configurations are available; contact your local Schneider Electric representative or distributor). 4 in. 4 in. 4 in. 4 in. IPCTC-EE IPCTC-EE IPCTC-3EE IPCTC-4EE 4 in. 48 in. 3 IPCTC-5EE IPCTC-6EE IPCTC-7EE IPCTC-8EE NOTE: All sections have both top and bottom conduit entry/exit points. 0-6 0 Schneider Electric This document provided by Barr-Thorp Electric Co., Inc. 800-473-93 www.barr-thorp.com