VM 6.1. Capacitive Air Gap Measuring Chains User s Manual P/N: M7A-110

Similar documents
PCS-200ESB Measuring Chains with LIN-300 Series Signal Conditioner. Front End Installation Manual (P/N: I2A-311)

HV-CS kv Edge Mount Triaxial Jack

5504 Thermocouple Analog Input Module

PM Series Power Meter

MODEL 245 / 345 High Range

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

Model 7705 Control Module

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

S66 Series Electronic Fan Speed Control

Resolver to Digital Expansion Board

Bluetooth Enabled Access Control MODEL BG-FE. Operating Instructions

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

5401 and 5402 Digital I/O Modules

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

KOBOLD TDA Series Digital Temperature Transmitter

Clipsal Bus Couplers. Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

Model 2380 Rack-Mount Kit

ETM-2040 Service Manual

SmartBlock I/O Module HE579MIX577/977 Isolated 4/8 Analog Inputs 2/4 Analog Outputs

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

EX-RC1 Remote I/O Adapter

Component identification

Model 4200-CVU-PWR. Parts Package. Introduction. PA-977 Rev. C / September 2016 *PPA-977C* 1

MODEL 245 / 345 DigiComp

XBR V4 INSTALLATION AND USER GUIDE

K-Beam Accelerometer. Acceleration. Capacitive MEMS, Triaxial Accelerometer. Type 8395A...

ORB TM 4-20 ma Input Box Installation & Operation Manual

Altivar 61/71 Adjustable Speed Drives Heatsink Fan Kits VZ3V1212 and VZ3V1216

The Butterfly LaserMount also offers all the features you would expect from a modern butterfly laser diode fixture, including:

K-Beam Accelerometer. Acceleration. Capacitive MEMS, Triaxial Accelerometer. Type 8396A...

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

MODELS DSH/DSV R-410A AIR SIDE ECONOMIZER KIT

Model 2380 Rack-Mount Kit

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

MODELS DSH/DSV R-410A AIR SIDE ECONOMIZER KIT

BCM2 Series Branch Circuit Monitors Quick Setup Guide

MAXIMA+ Series Rotary Level Indicator

LINE VOLTAGE TESTER CT101 USER S MANUAL. Please read this manual carefully and thoroughly before using this product.

Thank you for choosing the DIL LaserMount from Arroyo Instruments. The DIL LaserMount is designed for high performance and long term use.

Table of Contents. General Information. Document Sure-Aire Flow Monitoring System. User and Service Manual WARNING CAUTION

Draft sensor KMB series 30

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

INSTALLATION INSTRUCTIONS

1:1 Model Connection Interface

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

5521 Potentiometer Analog Input Module

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960, PMMC-1000 PM Series Power Meter

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

Tina 1A Blanking plug

INSTALLATION INSTRUCTIONS 07/2018

B&W RearView Camera Installation & Operation

Page 2 262/264 LaserMount User s Manual. Table of Contents

PTC/PT100 board 2.0 Option

INSTALLATION INSTRUCTIONS

5 B&W Rear View System Camera

SmartBlock I/O Module HE579MIX102 Isolated 6 Relay, 12 DC Inputs, 4 Analog Inputs

Product Information ROC 425 ROQ 437. Absolute Rotary Encoders with EnDat 2.2 for Safety-Related Applications

FOR SERVICE TECHNICIAN S USE ONLY

Product Information ROC 425 ROQ 437. Absolute Rotary Encoders with Solid Shaft for Safety-Related Applications

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

KOBOLD PDA Series Digital Pressure Transmitter

SAVE THESE INSTRUCTIONS

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

I/O Expansion Box Installation & Operator s Instruction Manual

APPLICATION CONTROL GUIDELINES. IntelliROL Power Supply PN Revision Date: March 15, 2017

P216. Condenser fan speed controller. Product bulletin. Features

MAXIMA + Series ROTARY LEVEL CONTROL

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4

SIAC-PS 3G SIGNAL ISOLATOR WITH POWER SUPPLY (PART NO. 8890) INSTALLATION INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS

Installation & Operation Guide

ZPU Acquisition Unit User s Manual for ZOOM Version 7.3 P/N M1A-230

Wiser EER260LLCR Load Control Control de carga EER260LLCR Contrôle de charge EER260LLCR

THE CTB08D LIGHT CONTOLLER

MT8050iE series. Installation Instruction (1) (2)

SCADAPack E 5405 Digital Input Hardware Manual

A1. Multilin EPM 4600 Meter Displays DIS3500/DIS5700. Quick Start Guide. GE Digital Energy

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

TRC-190 User s Manual

Model 2600B-PM V Protection Module with 1 A Clamp. Description / April 2015 *PPA * 1

KBMG MULTI-SPEED BOARD

DD1590 Series Proximity Driver. Connection Technology Center, Inc. Vibration Analysis Hardware. DD1590 Series. Proximity Probe Driver.

Differential Liquid/Gas Pressure Transmitter

Agilent Technologies E5339A 38-Pin Low-Voltage Probe

Analog Monitor Installation Manual

VibraLINK switchable junction boxes Installation and operating guide VLL series

User Manual CTP64-Rotate

GETTING STARTED GUIDE NI Channel, 50 Arms Continuous, 24-Bit, Analog Input Module

AC4G-D User s Manual

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Series 3700 Screw Terminal Assemblies Installation Instructions

Model 2657A-LIM-3 LO Interconnect Module

Flexible Rogowski Coil Integrator Kit with 4-20mA and 0-20mA. User's Manual

Series Amp Pad Mount Quick Connect Input and Output Power Panels

PRECAUTIONS FOR USE. Be sure to use indoor wiring within the specified voltage requirements. For extension cord, use the specified rating or more.

Transcription:

VM 6.1 Capacitive Air Gap Measuring Chains User s Manual P/N: 9428-25M7A-110

Safety Information The following manual contains information and warnings. They must be followed in order to keep the instrument in a working condition and ensure safe operation. Safety and Electrical Symbols Warning - Danger - Identifies conditions or practices that could cause physical harm or death. Caution - Identifies conditions or practices that could result in a permanent loss of data or damage the measuring chain and/or other equipment to which it is connected. Important Information - Identifies important information, hints, and tips that must be read and applied. Safety Precautions Warning - Danger Caution To use the described product correctly and safely, read and follow all safety instructions or warnings that appear throughout this manual. This product in intended to be used by qualified operators and maintenance personnel who recognize shock hazards and are familiar with the safety precautions required to avoid possible injury. Read and follow all installation, operation, and maintenance information before using this product. Use this product only as specified in this manual or the protection provided by this product might be impaired. When in doubt that safety protection has been impaired, make this product inoperative and secure it against any unintended operation. Use caution when working with voltage levels above 30 VAC RMS or 42 VDC. These voltage levels are potential shock hazards. Follow all generally accepted safety practices and procedures when working with or around electricity. Do not use this product in wet environments. NOTICE: Trademarks referenced herein are trademarks and registered trademarks of VibroSystM Inc. or third parties, and are the property of their respective owners. Third party trademarks are used for identification purposes only and shall not be construed as indicative of any relationship or endorsement between VibroSystM Inc. and the third parties. This manual is provided solely for guidance. VibrosystM Inc. takes no responsibility or liability for any damage caused by accidents, improper installation or misuse. Liability is limited to the repair and/or replacement of defective products. VibroSystM Inc. 2727 Jacques-Cartier E. Blvd, Longueuil, QC, Canada J4N 1L7 Phone: 450 646-2157 U.S. Toll-free Line: 800 663-8379 Email: techsupp@vibrosystm.com www.vibrosystm.com 2 VM6.1 - User s Manual 2017 VibroSystM Inc. All rights reserved

TABLE OF CONTENTS 1. VM6.1 MEASURING CHAIN OVERVIEW... 5 1.1 Description... 5 1.2 Main Unit Interventions... 6 1.3 Sensor Installation Overview... 7 2. TRIAXIAL EXTENSION CABLE OVERVIEW... 8 2.1 Description... 8 2.2 Installation Overview... 8 3. LIN-300 SERIES CONDITIONER OVERVIEW... 9 3.1 Description... 9 3.2 Installation Overview... 9 3.3 Connection... 10 3.4 M12 Connector Pinout... 11 3.5 Grounding the Signal Cable s Shield... 11 3.6 Output Signal Value... 11 3.7 Operation... 12 3.7.1 Boot Sequence... 12 3.7.2 LED Functionality... 12 VM6.1 - User s Manual 3

4 VM6.1 - User s Manual

1. VM6.1 MEASURING CHAIN OVERVIEW 1.1 Description The VM6.1 measuring chains are used to measure an air gap in large rotating machines. The raw signal picked up by the VM6.1 capacitive air gap sensor is sent to a LIN -300 series conditioner through a 0.5 m [19.7 in] integral cable and extension cable to be converted into a linearized 4 to 20 ma signal. The entire chain is then connected from the conditioner to an acquisition unit through a signal cable terminated by an M12 connector. VM6.1 Capacitive Air Gap Sensor Grounding Wire SMA Connector Integral Cable Sensing Face Important Information Because of the different measuring ranges covered by the VM sensors, different types of LIN-300 conditioners must be used. Refer to the table below for the model of LIN-300 Series conditioner corresponding to the sensor. VM6.1 Measuring Chain Combinations LIN-300 Series Model Extension Cable Type Measuring Range LIN-361-10S-3/30 10 m [33 ft] Type S * 3 to 30 mm [118 to 1181 mils] * Type S cable is designed for regular operating temperature. Refer to the product data sheet for detailed specifications. VM6.1 - User s Manual 5

Measuring Chain and Signal Cable Layout Integral Cable VM6.1 Sensor Grounding Wires Extension Cable LIN-300 Series Conditioner Grounding Wire Signal Cable M12 Connector 1.2 Main Unit Interventions Epoxy resins and silicone will be used inside the unit. A hole must be threaded in the stator core pressure plate to connect the integral cable s grounding wire on the sensor side. A protection box (or more) must be installed outside the stator core to house the LIN conditioner(s). Protective conduits must be routed throughout the unit to protect the cables. 6 VM6.1 - User s Manual

1.3 Sensor Installation Overview Important Information VibroSystM technicians should be present during measuring chain installation and commissioning. The sensor s sensing face must be parallel to the target s surface. Sensors must ideally be glued against stator laminations so they can face the plane area of rotor poles, usually beneath the second ventilation hole. The integral cable must also be glued to the stator core and covered with silicon for protection. Caution If sensors are to be glued on a stator with protruding wedges, make sure to use VibroSystM spacers. Grounding wires must NEVER be cut or altered. Integral cables are factory calibrated and must NEVER be cut or altered. Never exert traction on the integral cable or connector. Do not apply paint or silicone on the sensor s sensing face. VM6.1 - User s Manual 7

2. TRIAXIAL EXTENSION CABLE OVERVIEW 2.1 Description Triaxial extension cables are the link between the VM6.1 sensor s integral cable and the LIN-300 series conditioner. Triaxial Extension Cable Female Connector Male Connector Grounding Lug Grounding Lug PV311014A Before installing the extension cable, it is important to determine where the conditioner protection boxes will be installed, keeping in mind the cable s length. The cable and connections must be protected by a combination of conduit, protective tubing, and heatshrinkable jackets. Caution Never install extension cables on high voltage components. Extension cables are calibrated and must NEVER be cut or altered. Never pull on the SMA connector to route the cables. 2.2 Installation Overview 1. Make sure the integral cable s male connector is well secured to the extension cable s female connector. Extension Cable Female Connector 2. Sensor and extension cable grounding wires must both be connected to a grounded part of the machine. Caution Integral Cable Male Connector A protective heat-shrinkable jacket must be installed around the integral and extension cable s connection to protect it from debris and isolate it from the ground. 8 VM6.1 - User s Manual

3. LIN-300 SERIES CONDITIONER OVERVIEW 3.1 Description The LIN-300 series conditioners are signal conditioning units which, when paired with matching sensors and extension cables, deliver a 4 to 20 ma linearized raw output signal. The triaxial extension cable is connected to the conditioner through an SMA connector, while power input and signal output are provided by a signal cable through an M12 connector. LIN-300 Series Conditioner 3.2 Installation Overview The LIN-300 must be installed in a properly grounded protection box and mounting panel. The power/signal cable is limited to a maximum length of 300 m [984 ft]. Possible conditioner locations are limited by the length of the sensor s integral cable. Caution It is recommended to use a VibroSystM protection box since it is equipped with vibration dampers and offers excellent grounding. Using a generic box could affect the entire measuring chain s performance. VM6.1 - User s Manual 9

3.3 Connection 1. Make sure the grounding lug is firmly secured to the LIN- 300 s grounding terminal. Recommended torque: 1.7 Nm [15 in-lb] Grounding Lug 2. Make sure the integral cable s SMA connector is firmly secured to the LIN-300 s SMA socket. Recommended torque: 1.1 Nm [10 in-lb] SMA Connector 3. Make sure the M12 connector is firmly secured in place. Caution M12 Connector Grounding is achieved through the LIN-300 s four installation screws. 10 VM6.1 - User s Manual

3.4 M12 Connector Pinout The illustration below shows the LIN-300 s M12 male connector pinout. 3 4 5 2 1 The cable provided by VibroSystM may be replaced by any cable having similar characteristics.the table below shows the color codes, designations and specifications for VibroSystM s signal cable. M12 Connector Pin # Corresponding Color Code Designation Specifications 1 Brown Power Supply +24 VDC 2 White Current Output 4-20 ma (proportional to sensor s full range) 3 Blue Common 0 V 4 Black Not Used 5 Not Used 3.5 Grounding the Signal Cable s Shield The signal cable s shield must also be grounded. It is important that the shield be grounded on one end only to avoid creating a ground loop. If the M12 connector at the end of the signal cable is insulated from the shield, the shield must then be grounded on the acquisition unit side. However, if the M12 connector at the end of the signal cable is connected to the shield, connecting the signal cable to an already grounded LIN-300 conditioner will automatically ground the shield. In this case, the shield must not be grounded on the acquisition unit side. 3.6 Output Signal Value Once the sensor is connected, the LIN-300 s output signal value must be within the 3 to 22 ma range. The output signal provides linear current throughout the entire measuring range. The distance value is obtained by applying the following transfer formula: LIN-361-10S-3/30 D mm = (I out (ma) - 2.22) / 0.59 Over 4-20 ma Output D mils = (I out (ma) - 2.224) / 0.01505 Over 4-20 ma Output VM6.1 - User s Manual 11

3.7 Operation 3.7.1 Boot Sequence Once the sensor is connected, apply power to the LIN-300 and verify the 3-color LED indicator s flash sequence upon start-up. A normal boot sequence should be as follows: One orange flash, followed by green flashes. 3.7.2 LED Functionality Once the boot sequence is completed, the LED indicator will continue flashing green while the LIN-300 scans the measuring chain. Once the scan is completed, the LED reflects the chain s overall condition: LED Indicator Continues Flashing Green: Indicates a normal operation (Status OK). Flashes Red: Indicates an error condition. Two flash sequences are most likely to occur: Error Condition #1: The LED turns on for one second, followed by one brief flash. This means that the sensor is not connected. Error Condition #2: The LED turns on for one second, followed by two brief flashes. This means that the sensor s distance to the target is below the minimum detection range. If a different LED sequence from the ones explained above appears on the LIN-300, please contact VibroSystM. 12 VM6.1 - User s Manual