Priva Blue ID Network module SN1/SN2/SN3/SN3t

Similar documents
Priva Blue ID Communication module RS485 SC44

Priva Blue ID Communication module RS232 SC22

Priva Blue ID Relay output module DOR4/DOR8

Priva Blue ID Digital input module DI4/DI8/DI16

Priva Blue ID Analogue output module with manual override AO2m/AO4m

Blue ID Power injection module PI60

Blue ID Communication module RS485 SC44

DOR6. Components All functions and indications are on the front of the module. Characteristics

Priva Blue ID C-Line Mix input/output module MX34

Priva Blue ID system overview

Priva Blue ID C-Line system overview

Priva Blue ID C4 Controller with manual override C-MX34m

Ha-VIS econ 2000 Fast and Full Gigabit Ethernet Basic. Features

Gigabit Ethernet Industrial Switch 10 Port with Railway and Power Substation Certification

Model Number Structure

Ha-VIS mcon 3000 Next Generation Introduction and features

ECLYPSE Communication Modules

ex-s1110-xt Gigabit Ethernet Extenders

exp-s1110pe PoE+ Gigabit Ethernet Extenders

ECLYPSE Communication Modules

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

6 Port Unmanaged Industrial Gigabit Ethernet Switch w/ 4 PoE+ Ports and Voltage Regulation - DIN Rail / Wall-Mountable

NVT Phybridge, Inc Superior Court, Unit 3 Oakville, ON, L6L 0C4 Phone: Web:

LNP-800AGH-24 Series. Features INTRODUCTION DIMENSIONS

Features and Benefits. Certifications


Stride SE2 Series Unmanaged Industrial Ethernet Switches and Media Converters

RТTH DUAL ROOM SWITCH

Model Number Structure

NVT Phybridge, Inc Superior Court, Unit 3 Oakville, ON, L6L 0C4 Phone: Web:

MC 11 EB-2 Power supply cabinet with external bus, AC version

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

Rugged Industrial Media Converter

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Room automation station

LNP series. 5-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 1*10/100Tx, 12~36VDC Input.

Industrial Switches. 9 Industrial. Industrial Switch, 5 Ports 100Base-TX 554 Industrial Switch, 8 Ports 100Base-TX 555

KFC-200. Installation Guide

Hardened PoE Ethernet Switch

Stride Industrial Ethernet Switches

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

Hardened 10/100Base-TX IEEE802.3at PoE PSE Ethernet Extender

PSI-MODEM-SHDSL/SERIAL Copper Extender

NVT Phybridge, Inc Superior Court, Unit 3 Oakville, ON, L6L 0C4 Phone: Web:

Gigabit Ethernet Micro Switch Twisted Pair Uplink PoE

TN-5308 Quick Installation Guide

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

RXTH DUAL ROOM SENSOR / SWITCH

AI561 Analog Input Module

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

User Manual Entry Line Industrial Gigabit Ethernet High Power 60/95 W PoE Injector

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

User Manual. MS657208X Industrial Gigabit Ethernet Switch 8x 10/100/1000Base-T

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

iopac 8020 Series Rugged modular RTU controllers Overview Programmable RTU Controllers Ethernet bypass feature for seamless data transmission

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

4 or 8-Port Industrial Managed Gigabit PoE Switch. EHG7504 EHG7508 Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Power supply module, bus connection module

RuggedNet. RuggedNet GPoE+/Mi KEY FEATURES. Managed Industrial 10/100/1000 Power Source Equipment (PSE) PoE/PoE+ Ethernet Fiber Switch

RXTP ROOM TEMPERATURE

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Gigabit Ethernet Micro Switch 6 Port PoE

Thread length (overall length) material

4TX + 1MMFX Unmanaged Ethernet Switch

10/100Base-TX Industrial Ethernet Extender

TF501, TF521 Terminal Bases

4 or 8-Port Industrial Managed Gigabit PoE Switch. EHG7504 EHG7508 Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Industrial Gigabit Managed Switches

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

System Specifications

Quick Start Guide. Physical Description.

Rugged MediaConverter

BACnet/IP to BACnet MS/TP Router

Fiber optic converter audio and CAN TA OPERATION MANUAL

iologik 4000 Series Modular remote I/O Introduction iologik E4200 Specifications Remote I/O Slice Form Factor and Flexible I/O Variety

10/100TX to 100FX w/ 1 PoE Injector Industrial Media Converter User Manual

Overview. Seen as an extension of the main HVAC controller when configuring, allowing you to save engineering time.

Resistance measuring module

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

STBEHC3020KC counter kit STB - 1 CH Hz - 2 I

TM3AI4 module TM3-4 analog inputs

Island bus expansion module

Industrial Switches Industrial Switches

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

TU531, TU532 Terminal Unit

316TX-N. Phone: Fax: Web: -

gigabit industrial ethernet user manual Models , ,

10/100Base-TX Industrial Ethernet Extender

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

Entry Line Industrial Gigabit Ethernet Bridging Converter, PoE+ optional 1x 10/100/1000Base-T, 1x 100/1000 SFP

Installation Instructions for UL Rev A

Transcription:

Priva Blue ID Network module SN/SN2/SN3/SN3t The system supports both bus and star topologies. Power over Ethernet An operating unit (TouchPoint) can be connected to the port for PoE, for instance. A major advantage of PoE is that it does not require a separate power supply. Auto-MDIX The Ethernet ports provide auto-mdix so that crossover cables are not required for connecting to other devices. Shielding The ports have shielded connectors where the shielding is connected to the "Ethernet shield" terminal on the base. This means that you can choose whether or not to connect the shielding. A Priva Blue ID Network module provides the Priva Blue ID system with one or more ports. The module is available in various designs, for instance, with a port for Power over Ethernet (PoE) or for 2-wire. A 2-wire port provides an Ethernet connection via 2-wire twisted-pair cables and permits the reuse of existing cabling. PoE allows you to power an TouchPoint via the Ethernet connection. The module uses the same base as the controller. Modular design The module has a unique base. As a result of this, a module cannot be incorrectly positioned in a base. You simply click the base with module onto the DIN rail. Characteristics one or more Ethernet ports Power over Ethernet (PoE) 2-wire port for transparent Ethernet communication over 2-wire twisted pair cable hot swappable Ethernet port with auto-mdix 24 V system power supply monitoring clear indication per Ethernet port Priva Blue ID Lifeline LED for status of module Port for 2-wire The port for 2-wire combines Ethernet with the reuse of existing 2-wire twisted-pair cables. This allows you to use, for instance, existing and unused telephone or cabling for the data traffic. This saves both time and money. An additional advantage is that longer distances can be bridged using 2-wire. SN/SN2/SN3/SN3t

Clear indication Priva Blue ID Lifeline The modules are equipped with blue LEDs. Together, these LEDs form the Priva Blue ID Lifeline. If the blue line is continuously on, the modules and bases are in the correct place according to the configuration in TC Engineer. LED for Ethernet connection with PoE The LED for PoE shows whether a device is being powered via the PoE connection. LED for data communication This LED uses a flashing pattern to show the data communication over the corresponding port. Legend A B C D E F G H Priva Blue ID Lifeline LED for Ethernet connection with PoE LED for data communication LED for status of Ethernet LED for status of module connection for 2-wire LED for status of 2-wire reset button for 2-wire LED for status of Ethernet The LED for the status of the Ethernet connection shows whether the corresponding port is connected to another device. LED for status of module The LED shows the status of the module. The LED is on continuously when the module is working correctly. If not, and in special circumstances, the LED flashes. LED for status of 2-wire The LED for the status of the 2-wire uses a flashing pattern to show the connection status of the data communication via the 2-wire port. Connecting Ethernet devices SN module Port Ethernet ¹ The TouchPoint must be powered separately. SN module TouchPoint¹ Other SN modules (examples) Port number 2 3 4 Port Power over Ethernet Ethernet Ethernet 2-wire SN2 module TouchPoint² ² This is the preferred position, because the TouchPoint supports Power over Ethernet. - - SN3 module TouchPoint² - SN3t module TouchPoint² 2-wire SN/SN2/SN3/SN3t 2

SN module specifications General Module article description Priva Blue ID SN Network module Priva Blue ID SN2 Network module Priva Blue ID SN3 Network module Priva Blue ID SN3t Network module Module article number 502000 (V03:0 and higher) 5020002 (V03:0 and higher) 5020003 (V03:0 and higher) 5020004 (V04:0 and higher) Base article description Priva Blue ID S Base Base article number 5000 (V05:00 and higher) Number of Ethernet ports with PoE 0 Number of Ethernet ports without PoE 2 2 Number of ports for 2-wire 0 0 0 Indication Priva Blue ID Lifeline green LED for Ethernet connection with PoE orange LED for data communication green LED for status of Ethernet green LED for status of 2-wire green LED for status of module Dimensions (XYZ)¹ Weight Maximum power consumption (excluding PoE port power consumption) Maximum power consumption with maximum loading of PoE port Typical power dissipation² MTBF³ Construction Mounting of base Material Identification of connections QoS (Quality of Service) 6.5 x 9 x 7.4 mm (6.36 x 3.58 x 4.62 inches) module: 30 grams base: 235 grams 2.2 W -.5 W module: 40 grams base: 235 grams 2.2 W 20. W.5 W module: 45 grams base: 235 grams 2.3 W 20.2 W.6 W module: 65 grams base: 235 grams 4.5 W 22.4 W 4. W 4,300,000 hours 4,300,000 hours 4,300,000 hours 2,900,000 hours removable module on a base clicks onto DIN rail mixture of polycarbonate and ABS labelling with an explanatory abbreviation tag-based prioritisation 4 priorities fixed configuration standards: IEEE 802.p/q CoS IPv4 TOS IPv6 TC ¹ Excluding. mm room between the modules ² Dissipation under the following conditions: - I/O load of 50% - Energy saving mode on (LEDs off) ³ The MTBF is calculated according to the Telcordia SR-332 standard Issue 2 under the following conditions: - ambient temperature: 35 50 C - supply voltage: 24 VDC - time in operation per day: 24 hours - reliability level: 60 % SN/SN2/SN3/SN3t 3

Ethernet Network standard used Baud rate Connection of third-party equipment permitted Cable type required Maximum cable length Connector type Cable diameter (when using Priva Blue ID TouchPoint Flush Back Cover (for panel mounting)) IEEE 802.3 0BASE-T (0 Mbps) 00BASE-TX (00 Mbps) auto negotiation auto-mdix 0 Mbps and 00 Mbps yes UTP or STP, minimum category 5 00 m RJ45, shielded 4-6.5 mm 2-wire Network topology¹ Baud rate Maximum number of participants on segment Cable type required Cross section Maximum cable length between each two participants in a ² Maximum total cable length² Connector type bus, star, ring or tree 20.. 200 Mbps, depending on cable type, cable length, topology and number of participants 8 twisted pair (telephone or data cable) 0.2 2.5 mm² (without ferrule connector) 0.25 2.5 mm² (with ferrule connector) 500 m nominal 000 m nominal two-pin screw connector (polarity-insensitive connection¹) ¹ In a ring the wires in the twisted pair must not be crossed. ² Specification is based on test results with category 5E twisted pair cable and Alpha Wire 526C with 2 participants. The maximum cable length may be shorter for other cable types and other numbers of participants Power over Ethernet Network standard used IEEE 802.3af Powered Device (PD) Class 0 SN/SN2/SN3/SN3t 4

S base specifications General Weight Maximum power consumption Typical power dissipation¹ MTBF² 235 grams 0.6 W 0.6 W 8,760,000 hours ¹ Dissipation under the following conditions: - I/O load of 50% - Energy saving mode on (LEDs off) ² The MTBF is calculated according to the Telcordia SR-332 standard Issue 2 under the following conditions: - ambient temperature: 35 50 C - supply voltage: 24 VDC - time in operation per day: 24 hours - reliability level: 60 % Electrical Input voltage between SP and SG Maximum input current Minimum switch off voltage Maximum switch off voltage UFE-SP (max), UFE-SG (max), USP-SG (max) CFE-SP, CFE-SG RFE-SG Glass fuses Indication Switching voltage alarm output Switching current alarm output 2.6 VDC 26.4 VDC (24 VDC ± 0 %) 4.3 A (2.5 A for I/O modules and.8 A for SC module, SN module and controller) 2. VDC 26.9 VDC 30 VAC and +/- 30 VDC nf nominal MΩ nominal 3.5 AT green LED for system power max. 30 VAC max. 30 VDC 0. ma A with cosφ = Power supply The system power supply must comply with the following requirements. Requirements output voltage: 2.6 26.4 VDC double insulation between input and output Class 2 power supply for UL508, UL96, CSA C22.2 No. 4 and No. 205 General specifications of controllers, modules and bases Housing IP code Flammability class Recycle code Colour Device type IP30 (IEC 60529) V-0 (UL 94) 7 release surfaces of module and DIN rail release: blue (RAL503) other parts: white (RAL9003) open device, for use in a pollution degree 2 environment SN/SN2/SN3/SN3t 5

Installation and connection Installation DIN-rail type Maximum width of I/O modules, bus extension modules and controller in control panel: accessible to authorized personnel only can be clicked onto the DIN rail that is positioned horizontally or vertically on the mounting plate Note: The controller, SC module and SN module may only be mounted horizontally. in panel door integration in control panel: accessible to authorized personnel only can be clicked onto the DIN rail that is positioned horizontally on the mounting plate 35 x 7.5 mm (height x depth), in accordance with IEC 6075 20 m Environment Permitted temperature inside control cabinet during normal operation with horizontally mounted modules only (without airflow) Permitted temperature inside control cabinet during normal operation with vertically mounted modules only (without airflow) 0 50 ºC 0 35 ºC Permitted temperature during transport and storage -20 70 ºC Permitted relative ambient humidity Shock and vibration resistance Installation category 0 % 95 % (non-condensing) IEC 63-2 II Legislation and standards Canada / USA EMC Europe UL 508:2005 (industrial control equipment) UL 96:2007 (energy management equipment) UL 600-:2004 (measurement and control equipment) CSA C22.2 No 4-0: 20 (industrial control equipment) CSA C22.2 No 205-2: 202 (signal equipment) CSA C22.2 No 600--04 (measurement and control equipment) complies with 47 CFR Part 5 Subpart B, Class B (FCC Rules) Operation is subject to the following two conditions:. This system may not cause harmful interference. 2. This system must accept any interference received, including interference that may cause undesired operation. ISM-system, complies with Canadian ICES-00 Low voltage directive 2006/95/CE: EN 600-:200 (measurement and control equipment) EMC directive 2004/08/EC: EN 6326-:2006 (measurement and control equipment) EN 6000-6-2:2005 (generic immunity standard) EN 6000-6-3:2007 (generic emission standard) RoHS directive 20/65/EU complies with the WEEE directive 2002/96/EC International The Priva Blue ID S0 Controller is BTL registered at BACnet International. The Priva Blue ID S0 Controller is BACnet certified in accordance with ISO 6484-5/6. Priva is a member of the BACnet Interest Group Europe. SN/SN2/SN3/SN3t 6

SN/SN2/SN3/SN3t 7

Europe Office: UK Office: Canada Office: Your Priva partner: Priva Zijlweg 3 P.O. Box 8 2678 ZG De Lier The Netherlands T +3 74 522 600 F +3 74 522 700 www.priva.nl sales.building@priva.nl Priva UK Ltd. 34 Clarendon Road WD7 JJ Watford United Kingdom T +44 (0)923 83 480 F +44 (0)923 83 499 www.priva.co.uk sales@priva.co.uk Priva North America Inc. 3468 South Service Road Vineland Station Ontario LOR 2E0 Canada T +(905) 562-735 F +(905) 562-777 www.priva.ca contact.priva@priva.ca 50007_0.007_09-206