DeFelsko PosiTector IRT Infrared Thermometer Probes

Similar documents
Calibration Procedure. DeFelsko Corporation. PosiTector UTG. Ultrasonic Thickness Gage. Table of Contents

Calibration Procedure

Calibration Procedure. DeFelsko Corporation. CAL-P# and STDP# Polystyrene Blocks

Calibration Procedure

PosiTector DPM. Dew Point Meter. INSTRUCTION MANUAL v Simple. Durable. Accurate.

Infrared Thermometer User Manual

PosiTector PC. Powder Checker Coating Thickness Gage. INSTRUCTION MANUAL v. 1.0

See more with the NEW testo 880 thermal imager

Heavy Duty Psychrometer + IR Thermometer Model HD500

5mm Round With Flange Type Infrared LED Technical Data Sheet. Part No.: LL-503IRT2E-2AC

Dual Moisture Meter Pin / Pinless Moisture Meter

Surveymaster %WME DRY. Pro meter. Instruction Manual 99 Washington Street Melrose, MA Phone Toll Free

User's Manual. Professional IR Thermometer with USB

Nuclear Associates

Temperature Measurement and Calibration. Industrial Calibration Selection Guide. Multifunction Process Calibrator.

Professional Thermocouple Thermometer with Four Type K Inputs, Data Logging, and Optional Infrared Wand

1. Introduction 2. Specifications 3. Symbol Definition and Button Location 4. Operation Instructions 5. Temperature Measurement 6.

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

User's Guide. Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer. Patented

Introduction. Power-up / Power-down

Amphenol PROTIMETER. Advanced Sensors. Digital Mini. Protimeter Moisture Meter. Instruction Manual

Fluke Ti30 Thermal Imager. Provided by Everything needed for everyday imaging. Complete imaging solution. Lowest cost of ownership

-auto Power Off- T1/T2/T1-T2

IR Crop Temperature/ External Soil Temperature Meter PRODUCT MANUAL

Amphenol PROTIMETER. Advanced Sensors. Digital Mini. Protimeter Moisture Meter. Instruction Manual

Applying handheld test tools to preventive maintenance

3 Diagnostic and Detection Products

D-510 PISeca Single-Electrode Capacitive Sensor Probe

4-Channel Thermometer

LogTag TREX-8 MULTI USE TEMPERATURE RECORDER WITH REMOTE SENSOR

Infrared Thermometer Remote Temperature Measurement ( Non-Contact ) TES-1326S INSTRUCTION MANUAL

Model 2440 Service Manual Rev. B / December 2004

EA003 OPTICAL TACHOMETER CALIBRATION ADAPTER OPERATION MANUAL

5 Performance Verification

AC/DC Current Probe Model SL206 USER MANUAL

AC/DC Current Probe Model SL201

USER S MANUAL 8/2/2013 PRELIMINARY

LBTKG-CO462 TKG-CO2 SERIES. Carbon Dioxide Detector/Controller. Features. Professional Design & Manufacture CO 2 Controllers.

PCMM System Specifications Leica Absolute Tracker and Leica T-Products

PCMM System Specifications Leica Absolute Tracker and Leica T-Products

IRC 1100 Kalibrierstrahler / Calibration Source

FERITSCOPE MP30. Order number Version 2.0 Issue date 12/2001 Subject to changes. Operating Manual FERITSCOPE MP30 (2.

Infrared Thermometers

EE671 - Miniature Air Flow Transmitter

FLIR T Imaging and optical data. Minimum focus distance. Minimum focus distance with MSX. Spatial resolution (IFOV)

DPL4000 Portable Low Range Dew Point Analyzer

PROTIMETER. TimberMaster. Protimeter Moisture Meter (BLD5605, BLD5609, BLD5605-SW, BLD5609-SW) Instruction Manual. Amphenol.

DIGITAL SOUND LEVEL METER. Instruction Manual

EA15 CALIBRATION PROCEDURE

USER GUIDE. Differential Thermometer Datalogger. Model HD200

Thermometers. Operation Manual

LadyBug Technologies LLC Automated PowerSensor+ Field Certification Procedure

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7525

IAQ-CALC TM Indoor Air Quality Meter

Extech EX820 True RMS 1000 Amp Clamp Meter with IR Thermometer. User's Guide

Document Title Issue Date. TBE/KBE-DOC TBE/KBE Document List TBE/KBE-REV TBE/KBE Revision List

Quick Guide v. 1.1 DeFelsko Corporation USA 2012

ЗАО «БЕРГ АБ», (495) , Thermal cameras. Detect hot spots before they cause trouble

Bluetooth IR Pen. Instruction Manual

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1

Fluke Ti Series Thermal Imagers. Predict impending failures faster by seeing more

with PosiTector DPM probes Instruction Manual v. 1.0

DEA TORO Horizontal-Arm Coordinate Measuring Machines

TABLE OF CONTENTS FEATURES. Read manual carefully before using this product! Features 1. Overview 2. Specifications 3. Package Contents 3

Technical Note Series

Infrared thermometers with visible laser for measuring surface temperature without contact

User's Guide Extech EX840 True RMS 1000 Amp Clamp Meter with IR Thermometer

Hygro-/Thermometer. Operating Manual GFTH 95

350 Series AC/DC Clamp Meters

TESA UPD Gauge Block Comparator with a 25 mm Measuring Span

Luckylight. 5mm Round With Flange Type. White LED. Technical Data Sheet. Part No.: 584WC2C-W5-1PC-P

High Performance Infrared Thermometer with High D:S Ratio, Adjustable Emissivity, and Built-in Laser Sighting

DTM-321 REL HOLD T2 K-TYPE TEMP: 20 C 60 C 140 F C F HUMIDITY: %RH POWER-UP OPTIONS

EA014 TORQUE CALIBRATION ADAPTER OPERATION MANUAL

HMT330 Series Humidity and Temperature Transmitters for Industrial Applications

High-Precision Pneumatic Pressure Controller Series CPC8000-L/-X

Gas Analyzers Components for Gas Analysis

sensor, which compensates for ageing effects, is highly insensitive to pollution and offers outstanding long term stability.

Lasertalk Sales Demonstration

Instruction and Operation Manual

Digital Clamp Meter User Manual

DX3309 / DP1009 / DD / DC1009 Series

Industrial Temperature Calibration

SPRING LOADED RESISTANCE THERMOMETER CONFIGURATIONS

VM2800 & VM3800 VIBRACHECK METERS Installation Manual

API Gaging Practice. PMC Lone Star Technical Brief Doc. 100 Rev. B

Wide Bandwidth Strain Gage Input 3B18 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

SPECIFICATIONS ZU 1870MU. Panasonic Communications Co.,Ltd. Devices and Components Company. Manual Insertion Type Magnetic Card Reader NOTE: APPROVAL

Pronto-250 User manual Revision 2.0 i

IAQ-CALC TM Indoor Air Quality Meter

PosiTector DPM. Dew Point Meter. Full Guide v. 3.3

IRtec Rayomatic 60. Fiber Optic Infrared Thermometer INFRARED THERMOMETERS. "Excellence in measurements" 2-wire, 4-20 ma Transmitter

Indoor Air Quality Meter/Datalogger

Grayhill, Inc. La Grange, IL

TiR2,TiR3,TiR4, Ti40,Ti45,Ti50,Ti55 IR FlexCam Thermal Imager

Refrigerant Gas Leak Detector. DC-IR2 R32 Available. Catalogue ver FUSO CO., LTD TOKYO JAPAN

CAL250. Precision Acoustic Calibrator Manual

CarSense202 O P E R A T I N G I N S T R U C T I O N S V E HI C L E M O T I O N D E T E C T O R Johnston Parkway, Cleveland, Ohio 44128

38 MHz Passive Voltage Probe R&S RT-ZP1X

MP 101A HUMIDITY TEMPERATURE PROBE INSTRUCTION MANUAL

Transcription:

Management Procedure 2572 Revision: A Date Issued: April 12, 2018 Date Revised: Calibration Procedure DeFelsko PosiTector IRT Infrared Thermometer Probes Table of Contents 1 Introduction and UUC Performance Requirements... 2 Table 1-1 Measurement Ranges... 2 2 Measurement Standards and Support Equipment Performance Requirements... 2 Table 2-1 UUC Accuracy Requirements and Description... 2 Table 2-2 Minimum Use Specifications... 2 Table 2-3 Actual Surface Temperature Test Equipment Specifications... 2 Table 2-4 Calibration Environment and Warm-Up Requirements... 3 3 IR Temperature Calibration Set-Up Discussion... 3 4 Preliminary Operations... 3 5 Surface Temperature Calibration... 3 Figure 5-1... 4 6 Performance Requirements... 4 Table 7-1 Requirements and Calibration Data for DeFelsko PosiTector IRT Probes... 4 Management Procedure Change Notice... 5 Management Procedure MP 2572 Rev A Page 1 of 5

1 Introduction and UUC Performance Requirements 1.1 This procedure describes the calibration of the DeFelsko PosiTector IRT probes with the following specifications: Table 1-1 Measurement Ranges Function Measurement Range Resolution -70 to 380 C 0.1 C Surface Temperature (-94 to 716 F) (0.1 F) 1.2 The unit being calibrated will be referred to as the UUC (Unit-Under-Calibration). 2 Measurement Standards and Support Equipment Performance Requirements 2.1 The UUC accuracy requirements are based upon the published UUC performance specifications. 2.2 The test uncertainty ratio applied in this calibration procedure is 4:1 unless otherwise stated. The minimum surface temperature uncertainty ratio is 2:1. 2.3 Minimum-Use-Specifications are the minimum test equipment specifications required to meet all the UUC accuracy requirements and the test uncertainty ratio applied. Table 2-1 UUC Accuracy Requirements and Description UUC Function Range Accuracy Test Method Surface Temperature -70 to 380 C (-94 to 716 F) ± (1.0 C + 0.01 C per C) ± (1.8 F + (0.01 F per F-32 ) Infrared Calibrator Table 2-2 Minimum Use Specifications Function Range Accuracy -70 to 380 C ± 0.25 C Surface Temperature (-94 to 716 F ) ± (0.45 F) Table 2-3 Actual Surface Temperature Test Equipment Specifications Actual Equipment Specifications Manufacturer/Model # s Applicable Range Accuracy -15 to 0 C ±0.40 C >0 to 100 C ±0.50 C >100 to 120 C ±0.55 C Fluke 4180 Infrared Calibrator (5 to 32 F) (±0.72 F) (>32 to 212 F) (±0.90 F) (>212 to 248 F) (±0.99 F) Management Procedure MP 2572 Rev A Page 2 of 5

Caution: The instructions in this Calibration Procedure relate specifically to the equipment and conditions listed in this section. If other equipment is substituted, the information and instructions must be interpreted accordingly. Table 2-4 Calibration Environment and Warm-Up Requirements Measurement Standards & Support Equipment Environmental Requirements: Measurement Standards & Support Equipment Warm-up and Stabilization Requirements: Temperature: 23 ± 5 C. Relative Humidity: Less than 95% Fluke 4180 Infrared Calibrator: 30 minutes 3 IR Temperature Calibration Set-Up Discussion To limit the effect of extraneous infrared (IR) radiation during the calibration process it is recommended that the calibration target be 2 to 3 times larger than the detecting spot size of the IR sensor. The Fluke 4180 has a 152.4mm (6 ) diameter target so the IR sensor spot diameter needs to be between 50.8mm (2 ) and 76.2mm (3 ) to maintain the recommended ratio. The test set-up DeFelsko uses produces a 57mm (2.24 ) diameter detector spot centered on the calibration target. The IR sensor used in the IRT has a distance to spot ratio of 5.7:1 when measured at a 90% energy level. This means that 145mm (5.7 ) from the target 90% of the IR energy from a 25.4mm (1 ) spot is within the sensor field of view. To produce the previously mentioned 57mm (2.24 ) detector spot the DPM IR probe needs to be 325mm (12.8 ) from the target during calibration. 4 Preliminary Operations Note: Review the entire document before starting the calibration process. 4.1 Visual Inspection 4.1.1 Damage or excess wear must be repaired prior to beginning the calibration process. 4.1.2 Visually inspect the UUC for: Wear or damage to the probe body or tip Missing parts Proper identification 4.1.3 If the probe has a protective cap, remove it before proceeding. 4.1.4 Connect a PosiTector 6000 gage to the sensor fixture. 5 Surface Temperature Calibration 5.1 Verify the Fluke 4180 is set to an emissivity of 0.95 then set the temperature to 5 C and wait for the unit to beep indicating the set point has been achieved. Turn on the PosiTector gage. Note: If moisture condenses on the target you cannot take readings, you will need to wait for the target to dry and the Dewpoint to decrease. Management Procedure MP 2572 Rev A Page 3 of 5

5.2 Place the UUC in the sensor fixture (to ensure the IR sensor is centered and perpendicular to the calibration target at a distance of 325mm (12.8 )). Record the UUC and test equipment reading. Figure 5-1 5.3 Adjust the Fluke 4180 to 100 C and wait for the unit to beep indicating the set point has been achieved. Record the UUC and test equipment reading. 5.4 Remove the UUC from the sensor fixture. 6 Performance Requirements Note: The technician will collect the data needed to complete columns A and B. The technician shall then calculate the values for Column C and record all information as shown in table 7-1. Do not write in this procedure. Table 7-1 Requirements and Calibration Data for DeFelsko PosiTector IRT Probes Reference Units Set Point Test Equipment Reading (A) Gage Reading (B) Probe Measurement Accuracy (C) Allowable Tolerance Surface Temperature Low C 5 ± 1.0 Surface Temperature High C 100 ± 2.0 Note: To convert from C to F T F = 1.8 * T C + 32 Management Procedure MP 2572 Rev A Page 4 of 5

Management Procedure Change Notice Procedure Number: MP 2569 Revision Level: A Date of Change: April 12, 2018 Title: Calibration Procedure for DeFelsko PosiTector IRT Infrared Thermometer Probes Reason for Change: New product Description of Change: New procedure I confirm I have read and understand the procedure and the change described above. Printed Name Signature Date Management Form 0010.02-05/1998 Management Procedure MP 2572 Rev A Page 5 of 5