Avigilon Control Center System Integration Guide

Similar documents
Avigilon Control Center System Integration Guide

Avigilon Control Center 5 System Integration Guide. for Software House C CURE 9000

Avigilon Control Center System Integration Guide

Avigilon Control Center System Integration Guide

Avigilon Control Center Server User Guide

Avigilon Control Center Server User guide Version 3.8

Avigilon Control Center Virtual Matrix User Guide

Avigilon Control Center System Integration Guide

Avigilon Control Center Server User Guide

Avigilon Control Center 6 System Integration Guide. for Software House C CURE 9000

User Guide. Avigilon Control Center Gateway. Version 5.0. UG-ACCGateway5-A-Rev1

Avigilon Control Center Virtual Matrix User Guide

Avigilon Control Center Server User Guide. Version 5.8

Avigilon Control Center Virtual Matrix User Guide. Version 5.6

Avigilon Control Center 5 System Integration Guide. with S2 NetBox. INT-S2-B-Rev2

Avigilon Control Center Virtual Matrix User Guide. Version 5.4.2

Avigilon Control Center System Integration Guide

How to use Genetec Omnicast with Hikvision devices V1.0.0 ( )

Avigilon Control Center 6 System Integration Guide

Avigilon Control Center 6 Software

How to Use Avigilon with Hikvision Devices? (V1.0.0)

Avigilon Control Center 6 Software

Avigilon Control Center 5 System Integration Guide

CompleteView & C CURE 9000 Integration Quick Start Guide Salient CompleteView

ACTi Mobile Server User s Manual

User Guide. Avigilon Control Center Gateway. Version UG-ACCGateway5-A-Rev2

Avigilon Control Center Core Client User Guide. Version 5.8

Pelco Video Server 2.7 / Software House C CURE 9000 v2.7 Troubleshooting Guide C5638M-F 10 / 2018

Avigilon Control Center Standard Client User Guide. Version 6.0

Video Monitoring. Contents CHAPTER

Avigilon Control Center 5.2 software with HDSM Technology

Speco Manager. User s Manual SPECO MANAGER VERSION OR HIGHER MANUAL VERSION 2.3.0

DIGIOP ELEMENTS V8.1 Software-only Installation Guide

DIGIOP ELEMENTS V8.7 NVR Software-only Installation Guide

HD Network Video Recorder Workstation

D-ViewCam Standard/Professional/Enterprise

Avigilon Control Center Standard Client User Guide. Version 5.2.2

C CURE HDVR Integration User Guide. Version 1.93 REVISION A0

Avigilon Control Center 6 Software

Video Monitoring. Contents CHAPTER

Avigilon Control Center Enterprise Client User Guide. Version 5.8

Multi-NVR Manager. Quick Start Configuration Usage

Professional Edition. Hardware Requirements

Table of Contents. Chapter 1 Introduction Features System Diagram... 2

Avigilon Control Center Enterprise Client User Guide. Version 5.6

Avigilon Control Center 5.0 software with HDSM

Table of Contents. Chapter 1 Introduction Features System Diagram... 3 Multi-Server... 3 Single-Server... 3

Camera Control for Windows

User Manual. Central Monitoring Software for TER-series recorders. CenPro

The Printer Out plugin PRINTED MANUAL

IDIS Solution Suite. Streaming Service. Software Manual. Powered by

Milestone XProtect Basis+

OnSSI C CURE 9000 Video Integration

Release Notes. PC spec. Enhancements. Product: ACTi NVR Server Version: v SR1 (build ) Release Date: Apr. 16, 2007

Video Management Software

Ocularis. Installation & Licensing Guide

Introduction of ivms-4200 v2.0

NetEVS 2.0 Getting Started Guide

Avigilon Control Center Standard Client User Guide. Version 6.4

Avigilon Control Center Gateway User Guide. Version 6.6

Avigilon Control Center 6 Software

Table of Contents. Chapter 1 Introduction Features System Diagram... 2 Multi-Server... 2 Single-Server... 3

Avigilon Control Center Web Client User Guide

Quick Start Guide. State of the art hyper-optimized video management platform designed for ease, speed and efficiency.

Demonstrating Vi-System and Vi-Search. Vi-System 4.2 Vi-Search 2.1

Avigilon Control Center Gateway User Guide. Version 5.8

Avigilon Control Center 5 System Integration Guide. for Jacques IP Audio Intercom System

Password: admin DW-BJCUBE2T-LX DW-BJCUBE4T-LX DW-BJCUBE6T-LX DW-BJCUBE9T-LX DW-BJCUBE12T-LX DW-BJCUBE18T-LX

Agilent Genomic Workbench 6.5

Avigilon Control Center 6 System Integration Guide. for Jacques Technologies IP Audio Intercom System

A&E SPECIFICATIONS. TeleEye suresight Pro Video Management Solution

Senstar Symphony. 7.2 Installation Guide

Agilent CytoGenomics 2.5

Avigilon Control Center Core Client User Guide. Version 6.10

Intellio System Software Specification. Intellio System Software Specification. December Intellio Ltd. Page 1

The DNP3 plugin PRINTED MANUAL

The Data timeout plugin PRINTED MANUAL

The Send keystrokes plugin PRINTED MANUAL

The Aggregator plugin PRINTED MANUAL

PC NVR Professional Software

Lab Determining Data Storage Capacity

DMAC-VMS-1CH, 4CH, 8CH, 16CH, 24CH, 32CH, 64CH, 128CH

IDIS Solution Suite. Video Wall Service. Software Manual. Powered by

Milestone XProtect Basis+

Milestone. XProtect. System Migration Guide Migration from XProtect Enterprise to XProtect Corporate

Avigilon Control Center 5.4 software with HDSM Technology

The "Event generator" plugin PRINTED MANUAL

Remote Backup Software

The TCP redirecting plugin PRINTED MANUAL

Bosch Video Management System Version 3.0.1

Page 1 of 18 Dave Pimm Avid Technology Dec 6th, 2013 Rev B

Avigilon Control Center Standard Client User Guide. Version 6.10

Autodesk Revit Structure 2012 System Requirements and Recommendations. Minimum: Entry-level configuration. Operating System Microsoft Windows 7 32-bit

Map Editor Release Notes December, 2010 EN V (1) Innovative Solutions

Grandstream Networks, Inc. GSurf User Manual

FortesServer An Integrated Ready to Deploy Video Management Server

SecurOS Server / Workstation Specifications INTELLIGENT SECURITY SYSTEMS 1480 US 9 NORTH, SUITE 202 WOODBRIDGE, NJ v.2.1

Avigilon Control Center Standard Client User Guide. Version 6.12

The Log packing plugin PRINTED MANUAL

ivms-5200 Mobile Surveillance V1.1.1 Software Requirements & Hardware Performance

Transcription:

Avigilon Control Center System Integration Guide with Software House C Cure 9000 INT-CCURE-B-Rev2

Copyright 2013 Avigilon. All rights reserved. No copying, distribution, publication, modification, or incorporation of this document, in whole or part, is permitted without the express written permission of Avigilon. In the event of any permitted copying, distribution, publication, modification, or incorporation of this document, no changes in or deletion of author attribution, trademark legend, or copyright notice shall be made. No part of this document may be reproduced, stored in a retrieval system, published, used for commercial exploitation, or transmitted, in any form by any means, electronic, mechanical, photocopying, recording, or otherwise, without the express written permission of Avigilon. Software House, C Cure and C Cure 9000 are registered trademarks of Tyco International Ltd and its respective companies. Avigilon has made every effort to identify trademarked properties and owners on this page. All brands and product names used in this document are for identification purposes only and may be trademarks or registered trademarks of their respective companies. Avigilon Tel +1.604.629.5182 Fax +1.604.629.5183 http://www.avigilon.com Revised 2013-2-27

Table of Contents Introduction.........................................1 Requirements............................................ 1 Server Requirements............................... 1 Client Requirements................................ 2 Software Upgrade......................................... 2 For More Information...................................... 2 Installation..........................................3 Servers................................................. 3 Client................................................... 3 Checking the License in Avigilon............................. 3 Checking the License in C Cure 9000......................... 3 Enabling the Integration in C Cure 9000........................ 4 Avigilon Configuration................................5 Assigning Logical IDs to Cameras............................ 5 Adding an Integration User in Avigilon......................... 6 C Cure 9000 Configuration.............................7 Adding Avigilon Servers and Cameras......................... 7 Adding Server Alarms...................................... 8 Adding Camera Alarms..................................... 9 Using the Integration................................11 Troubleshooting....................................12 Avigilon Server Component Not Available..................... 12 Camera Is Not Imported................................... 12

Introduction Avigilon Control Center System Integration Guide with Software House C Cure 9000 The Avigilon Control Center system integration with the Software House C Cure 9000 software allows users to use the C Cure 9000 interface to access Avigilon Control Center features. Specifically, users can view live and recorded video, and control PTZ devices from the Avigilon Control Center through the C Cure 9000 software. Requirements Vendor Avigilon Avigilon Avigilon Avigilon Requirements Control Center Server Software 4.10.0 and later Control Center Client Software 4.10.0 and later Avigilon Third Party Integration Licence: ACC-CCURE9-NVR Avigilon-C Cure 9000 integration executable file: Avigilon CCure Integration.exe The file can be downloaded at http://avigilon.com/#/support-and-downloads/forsoftware/integration-and-plug-in-downloads/ Software House Software House C Cure 9000 version 2.02 C Cure 9000 Integration Software License: CC9000-AVIGILON Server Requirements The following table lists the system requirements for an Avigilon HD NVR Server with a recording capacity of 32 MB/s from up to 128 cameras. The specifications below are intended for an HD NVR Server with only remote viewing: OS CPU System RAM Video card Network card Hard drives Recommended Requirements Windows XP SP2, Windows XP SP2 x64, Windows Vista 32-bit or 64-bit, Windows Server 2003 SP2, Windows Server 2008, or Windows 7. A 64-bit operating system is recommended. Intel Quad Core Xeon 2.0 GHz processor. 4 GB DDR2 n/a 1 Gbps Intel Pro/1000 or Broadcom NetXtreme II Server Adapters SATA-II 7200 RPM Enterprise Class Hard Drives 1

Client Requirements The following table lists the minimum requirements for a Client that uses the integration for viewing video: Minimum Requirements Monitor resolution 1280 x 1024 OS Windows XP with Service Pack (SP) 2 or later, Windows Vista, or Windows 7 CPU System RAM Video card Network card Hard disk space Intel Single Core 2.4 GHz processor 1 GB PCI Express, DirectX 9.0c compliant with 128 MB RAM (Intel GMA 900 or better, NVIDIA 6600 or better, ATI X1300 or better) 100 Mbps 500 MB Software Upgrade Avigilon software and integration upgrades are available for download from the Avigilon website. Check http://avigilon.com/#/support-and-downloads regularly for available upgrades. For information about the latest Software House C Cure 9000 upgrades see the Software House website: http://www.swhouse.com/support/upgrade_center.aspx For More Information For more detailed information about the procedures outlined in this guide, refer to the specific software documentation. Avigilon Control Center Client User Guide Avigilon Control Center Server User Guide C Cure 9000 Help C Cure 9000 Server Management Application User Guide C Cure 9000 Licensing User Guide 2

Installation Avigilon Control Center System Integration Guide with Software House C Cure 9000 All C Cure 9000 services and components must be turned off before the integration can be installed. The Avigilon-C Cure 9000 integration software (Avigilon CCure Integration.exe) must be installed on either a server or client that is connected to your C Cure 9000 system. NOTE: Integration upgrades can be installed on any machine that was previously running the integration. Servers Install the following on any server in your network. Client C Cure 9000 server software Avigilon Control Center Server software Install the C Cure 9000 client software on any workstation that requires access to the C Cure 9000 system. Checking the License in Avigilon After you have installed all the required software, check that the Avigilon Third Party Integration license was properly applied. 1. Open the Avigilon Control Center Admin Tool. 2. Select the Settings tab and click Licensing. The License Activation dialog box appears. The dialog box must say Integration Connections: Yes or the software was not properly licensed. Checking the License in C Cure 9000 1. Open the C Cure 9000 License application. 2. Select License > Validate. A popup dialog box appears and notifies you if all licenses are valid. 3. Select the Options tab and check that the Avigilon Control Center is listed. 3

Enabling the Integration in C Cure 9000 After you check the licenses, you must enable the integration in the C Cure 9000 software. 1. Open the C Cure 9000 Server Management Application. 2. Ensure the CrossFire Service and Server Component Framework are running. If not, click Start Server Component Framework. 3. Select the Server Components tab. 4. Right-click the Avigilon server component and select Start server component. The server component is labeled Avigilon.NextGenConnectedProgram.Server. The traffic light icon beside the Avigilon server component turns green. 4

Avigilon Control Center System Integration Guide with Software House C Cure 9000 Avigilon Configuration Once the required licence and software have been installed, configure the Avigilon Control Center for the integration. See the Avigilon Control Center Client User Guide for more information about each of the required configurations. Assigning Logical IDs to Cameras In the Avigilon Control Center Client software, assign a logical ID to each camera. The C Cure 9000 software will only detect cameras with a logical ID. By default, cameras do not have a logical ID. 1. In the Avigilon Control Center Client software, right-click a camera in the System Explorer and select Setup. 2. In the camera Setup dialog box, click General. 3. In the General settings dialog box, enter a Logical ID for the camera. The logical ID must be unique number. The logical ID should have no more than nine digits. 101 5

Adding an Integration User in Avigilon To protect the security of the Avigilon Control Center Server, add a user to the Avigilon software specifically for connecting to the integration. See the Avigilon Control Center Client User Guide for details about how to add users. This user must have the following permissions to enable all the integration features: View Live Images Use PTZ Controls Lock PTZ Controls Trigger Manual Recording View Recorded Images Export Images Backup Recorded Images The integration user name and password is used to add Avigilon servers to the C Cure 9000 application. 6

Avigilon Control Center System Integration Guide with Software House C Cure 9000 C Cure 9000 Configuration After the Avigilon Control Center configurations are complete, configure C Cure 9000 to use the integration. See the C Cure 9000 Help for more information about each of the configurations. Adding Avigilon Servers and Cameras 1. Open the C Cure 9000 Administration Workstation. 2. Select the Video tab. 3. In the Video Tree pane, right-click Company Name and select Avigilon Video Server > New. 7

4. In the Video Server Editor, give the server a name and description. 5. Enter the username and password you created for the integration. See Adding an Integration User in Avigilon on page 6 for more information. 6. Enter the Avigilon server IP address. If the integration software was installed on the same server as the Administration Workstation software, enter the localhost IP address instead (typically 127.0.0.1). 7. Select the Enable check box then click Connect. Once connected, the Enable check box will change to Online. 8. Click Import Cameras. NOTE: Only cameras that have logical IDs are imported into the C Cure 9000 system. See Assigning Logical IDs to Cameras on page 5 for more information. 9. Click Save and Close. The new server and imported cameras are added to the Video Tree pane. Adding Server Alarms You can create a server alarm that is triggered by the Avigilon server s online or offline status. 1. Open the C Cure 9000 Administration Workstation. 2. In the Video Tree pane, right-click the Avigilon server and select Edit. 8

Avigilon Control Center System Integration Guide with Software House C Cure 9000 3. In the Video Server Editor, select the Alarms tab then click Add. 4. In the Property column, select Video Server Alarm. 5. In the Values column, select what triggers the alarm when the server becomes Offline or Online. 6. In the Action column, select how you want C Cure 9000 to respond to the alarm. 7. If you selected Video Camera Action, select the Action Type tab and select what the camera will do. 8. In the Schedule column, select when the alarm can be triggered. 9. Click Save and Close. Adding Camera Alarms You can add a camera alarm that is triggered by a camera event, like motion detection. 1. In the C Cure 9000 Administration Workstation, right-click a camera in the Video Tree pane and select Edit. 9

2. In the Video Camera Editor, select the Alarms tab then click Add. 3. In the Property column, select Video Camera Alarm. If you are configuring an analog encoder, you can also select Videoloss. 4. In the Value column, select what triggers the alarm. If you selected the Video Camera Alarm property, select Motion. If you selected the Videoloss property, select True or False. 5. In the Action column, select how you want C Cure 9000 to respond to the alarm. 6. Select the Action Type tab to further define the selected Action setting. 7. In the Schedule column, select when the alarm can be triggered. 8. Click Save and Close. 10

Avigilon Control Center System Integration Guide with Software House C Cure 9000 Using the Integration Now that the integration has been installed and configured, you can use the C Cure 9000 system to monitor video and alarms detected by cameras connected to the Avigilon system. See the C Cure 9000 Help for more information about using the different features in the C Cure 9000 system. 11

Troubleshooting If the following troubleshooting solutions do not resolve your issue, contact Avigilon Support at support@avigilon.com. Avigilon Server Component Not Available When you try to enable the integration in the C Cure 9000 software (as described in Enabling the Integration in C Cure 9000 on page 4) the Avigilon server component is not listed. Check that the following integration requirements were met and the integration was installed correctly: You have an integration license from Avigilon and Software House. Both the Avigilon Control Center Server software and the C Cure 9000 Server software are installed on the same network. When you installed the integration software, all C Cure 9000 services and components were turned off. You installed the latest version of the Avigilon C Cure 9000 integration found on the Avigilon website: http://avigilon.com/#/support-and-downloads/for-software/ integration-and-plug-in-downloads/ Camera Is Not Imported After you ve added the Avigilon server and cameras to the C Cure 9000 software, a camera that you require is not listed in the Video Tree pane. There are typically two reasons why the camera does not appear in the C Cure 9000 software: 1. The camera is connected to an Avigilon Control Center Server that has not been added to the C Cure 9000 software. You can correct this by performing one of the following: Add the Avigilon Control Center Server to the C Cure 9000 software. See Adding Avigilon Servers and Cameras on page 7 for more information. Connect the camera to a server that has already been connected to the C Cure 9000 software. In the Avigilon Control Center Client software, select Tools > Connect/Disconnect Cameras and disconnect the camera from its current server then connect it to the server that is linked to C Cure 9000. 2. The camera does not have a logical ID. Perform Assigning Logical IDs to Cameras on page 5. 12