Switched Mode Power Supply Operating manual PAP800

Similar documents
ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

MSR 2400W. Multi purpose Power System for Telecom and Industrial Applications. Nominal Output Voltage. Voltage Setting Range

Rhino PSM Power Supplies. Operating Instructions

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

MSR 2400R. Rugged Power System for Military and Heavy Duty Applications

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

INSTALLATION MANUAL SLI 50 INVERTER

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Power Supply. Users Guide PRODUCT MANUAL. WESTELL.COM Westell Technologies MNL rd

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

SIM-9106/9303 High Current Switching Mode Power Supply with C.C., C.V., Remote Control & Sensing User Manual

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

MVS RAIL ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

IF-80x Outdoor Terminal

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

PRO1 V21.xxx series MID DIN rail single phase two wire energy meter

Power supply CP-C 24/5.0

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

RXTP ROOM TEMPERATURE

SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS

PRO1250D CT MID DIN rail three phase four wire energy meter. User manual Version 1.5

Model HM-535 Power Supply Installation and Service Instructions

ABL8BBU24200 battery control module V DC - 24 V - 20 A - for regulated SMPS

200 VA bis VA 10 V bis 80 V 2 A bis 320 A. Source-Sink NL

Switching Power Supply S8E1. Ordering Information. Compact and Economical Switching Power Supply

NTP-5521/5531/5561 SWITCHING MODE POWER SUPPLY

Voltage Current Front-mounting bracket

EX-RC1 Remote I/O Adapter

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

PRO2DM DIN rail single phase two wire energy meter

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

Test and Measurements Automated Systems Component Device Testing Semiconductor Processing & Burn-in Aerospace & Satellite Testing

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

LVN5200A-R2, rev. 1, Hardware Installation Guide

INSTRUCTION SHEET. Eaton Logic Controller ELCB Controllers

MC 11 EB-2 Power supply cabinet with external bus, AC version

Technical Manual Nova: Cabinet Security Management System (CSMS)

PRO1250D CT M-bus MID DIN rail three phase four wire energy meter. User manual Version 1.11

BACS_GX_R_AUX Businterface

USER MANUAL INSTALLATION MANUAL. Isolation transformers. ITR Isolation Transformer 7000 W 230V/32A

Power supply CP-D 12/2.1 Primary switch mode power supply

User Manual. Solar Inverter for Water Pump

Features: DSFB108 v1.1 DIN rail mounted switch 10-ports DSFB108 with buffer power supply for 8 IP cameras

QUINT-PS/ 1AC/24DC/ 5

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

D1093S INSTRUCTION MANUAL. D SIL 3 Relay Output Module with Line and Load diagnostics. DIN-Rail Model D1093S

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

DRT-301 A/D. User manual. Three phase four wire DIN rail energy meter. (Seven modules) 1.1 Safety instruction. 1.2 Foreword. 1.3 Performance criteria

PRO-1250D CT MID DIN rail three phase four wire energy meter.

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

EX-RC1 Remote I/O Adapter

PRO-75 SERIES. User manual

RTU500 series Data Sheet Power Supply CP-E 24/2.5

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

Switching Power Supply

XTM1250SA DIN rail three phase four wire LCD display energy meter

Redundancy unit CP-A RU

SLI 15 Inverter Series Data Sheet 1500 Watt, 1U Compact Inverters

Features: DSB98 v1.0 DIN rail mounted switch 9-port DSB98 with buffer power supply for 8 IP cameras

SLI 15 INVERTER SERIES, 1500 W

Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24

MINI-PS AC/10-15DC/8

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

RТTH DUAL ROOM SWITCH

QUINT-PS AC/24DC/10

Chameleon Stand-alone

INSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Repeater Relay Output, Termination Board Models D6032S, D6032D

POWERSOLVE ELECTRONICS LTD PSL400-XX series Conduction Cooled Power Supply Engineering Specification

AC-DC Converter REC K10

Power supply CP-E 24/10.0 Primary switch mode power supply

EX-RC1 Remote I/O Adapter

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

Power supply CP-E 48/1.25 Primary switch mode power supply

QUINT-PS/24DC/48DC/ 5

RECTIFIER PSR380 (48V VERSION) USER MANUAL UM_PSR380_48V_E_R1.0

CMSA-100 Manual. Cinema Media Server Automation

Industrial motor controller for brushed DC motors 24 VDC

MBP68300 SERIES. AC-distribution, Static Switch and Manual Bypass for DAC60000 Dual Inverters. BPU69000 Dual External static switch Plug-in unit

SITOP 3-phase 24 V DC, 20 to 40 A

Switching Power Supply S82J. Ordering Information. Open-Frame, Covered-Frame, or Enclosed-Frame Type with Capacity Up to 600 W

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:

PV Rapid Shutdown device

Operating and Maintenance Instructions

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

The 2U package makes the unit suitable for using in workstations, storage systems, racks for industrial and many other applications.

QUINT-PS/ 1AC/24DC/20/CO

ABB i-bus KNX Switch Actuator, x-fold, 6 A, MDRC SA/S x.6.1.1, 2CDG x R0011

CLS LDV-45. CLS Atmosphere LED-panel CLS LDV-45

User Manual. 2.2KW/7.5KW/11KW Solar Inverter for Water Pump. Version: 1.8

MINI MCR-SL-CVS NC

POE084824B. PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. v.1.1 EN* Edition: 7 from

Transcription:

Features: Switched mode power supply Wide output 0 144Vdc Analog control by an external 0 5Vdc Power failure alarm output Master-slave connection Powerfinn PAP series is a high power, lightweight, advanced power supply series using modern switching technology. All units can be used as a power supply or constant voltage battery charger. The output voltage and output current can be adjusted from 0 to maximum value by a trimmer on the front panel, or by an optional 0-5V analog control. Specifications Input voltage 55 250Vac (55 0VAC reduced power, see curve p. 3) Input current 4,5 A Power factor >0,98 Efficiency (2Vac, 10%...100% load) 85 90% Inrush current <30A, limited by an NTC resistor Input fuse (inside the unit) 6,3A Line regulation ±0.1% Load regulation ±0.5% Output setting accuracy ±0.1% Output ripple (f>50hz) <50 mvrms Hold-up time > 5 ms Status LED indicator O: power OK Isolation input-chassis 1500 Vac input-output 3750 Vac output-chassis 500 Vac Standards safety EN 60950-1:01 EMC EN 55022B, Approvals All models CE marked CB certificate with U.S. deviations 24V, 36V and 48V versions Protection class mechanical IP metal enclosure electrical Class 1 Dimensions w x h x d 2 x 112 x 73 mm Weight 1,55 kg Mounting DIN-rail, wall, bench Connectors input Power chord 1,5m output 24 V 96 V models 6 mm 2 screw terminals 2 m output cables 12 V models 2 m 10 mm 2 cable Cooling Temperature controlled fan Operating temp 0 C + C 1

Power Supply Models Trimmer adjustable power supplies Model Input voltage **) Nomina voltage Voltage Setting Nomina current Curren t setting Max powe r Installation/dimensions (width x height x depth) PAP800/12 55-250Vac 12Vdc 0-18Vdc 50A 0-50A 700W Wall /bench 2x112x73 PAP800/24 55-250Vac 24Vdc 0-36Vdc 30A 0-30A 800W Wall /bench 2x112x73 PAP800/36 55-250Vac 36Vdc 0-54Vdc A 0-A 800W Wall /bench 2x112x73 PAP800/48 55-250Vac 48Vdc 0-72Vdc 15A 0-15A 800W Wall /bench 2x112x73 PAP800/72 55-250Vac 72Vdc 0-108Vdc 10A 0-10A 800W Wall /bench 2x112x73 PAP800/96 55-250Vac 96Vdc 0-144Vdc 7,5A 0-7,5A 800W Wall /bench 2x112x73 0-5 V external control signal adjustable power supplies Model *) Input voltage **) Nomina voltage Voltage Setting Nomina current Curren t setting Max powe r Installation/dimensions (width x height x depth) PAP800/12AI 55-250Vac 12Vdc 0-18Vdc 50A 0-50A 700W Wall /bench 2x112x73 PAP800/24AI 55-250Vac 24Vdc 0-36Vdc 30A 0-30A 800W Wall /bench 2x112x73 PAP800/36AI 55-250Vac 36Vdc 0-54Vdc A 0-A 800W Wall /bench 2x112x73 PAP800/48AI 55-250Vac 48Vdc 0-72Vdc 15A 0-15A 800W Wall /bench 2x112x73 PAP800/72AI 55-250Vac 72Vdc 0-108Vdc 10A 0-10A 800W Wall /bench 2x112x73 PAP800/96AI 55-250Vac 96Vdc 0-144Vdc 7,5A 0-7,5A 800W Wall /bench 2x112x73 *) Cable sets with modular connectors are included: 1,5 m cable for analog control and 2,5 m for temperature compensated models **) Reduced power 55 0Vac, see curves; max 600W when used with DC input Models with power failure output relay (24V models as type designation example) Model Option description Cable set PAP800/24H Trimmer adjustable model with power failure alarm relay 1,5 m, modular connector PAP800/24AIH Analog controllable model with power failure alarm relay Analog + relay cables PAP800/24TH Temperature compensated model with power failure alarm relay Temp. comp + relay cables Master-slave connection (24V models as type designation example) Master units ***) Slave units PAP800/24, PAP800/24AI or PAP800/24T PAP800/24S RS232 control bus in/out Control to slave via RS232 bus PAP800/24SH slave unit with relay, RS-232 bus in only Cable set for master slave connection included in slave unit type number, 0,6 m modular connectors at both ends ***) Master unit or slave with RS232 bus output cannot include the alarm relay Customized versions on request Cyclic battery chargers or customized charging curves for all kind of batteries Sense models IP44 enclosures, 19 enclosures 2

Characteristics 36V 10 18V 12V 15V, 50A 10 30 50 (A) 30 10 30V, 26A 26V, 30A 24V 10 30 (A) 100 108V 1 1 100 144V 1V, 6.3A 106V, 7.5A 50 54V 72V 80 90V, 8.5A 80V, 10A 80 30 10 45V, 17.5A 39V, A 36V 10 (A) 60 60V, 13A 53V, 15A 48V 5 10 15 (A) Nomina current / voltage characteristics PAP 800 60 72V 5 10 (A) 60 5 96V 10 (A) Pout (W) 800 600 0 0 100 0 260 Uin 46V START Output power / input voltage de-rating characteristic (see power limitation and start-up at DC-input). Installation 1. The location must be dry, dust-free and indoor. The acceptable full power temperature is 0 C + C. Higher ambient temperature will limit the power (see curve). The power supply is not waterproof. Keep it dry and away from areas with high humidity in order to avoid the risk for electrical shock and damages to the charger. 2. Equipment must be connected to an earthed mains socket-outlet. 3. The power supply can be installed horizontally or vertically. In case the power supply is mounted vertically with the cable plate downwards then installation area needs to be RESTRICTED ACCESS LOCATION and unit to be mounted on a concrete floor or other non-combustible surface. Vertical mounting is prohibited in case this condition cannot be met. 4. Leave at least 10 cm free space at both ends of the power supply to ensure sufficient ventilation. 5. When used as a charger, the charging process generates explosive hydrogen gas. Keep the area well ventilated Never use an open flame or equipment that produce sparks close to the power supply and battery. Wall mounting Screw the assembly board to the wall using the mounting holes in the back of the board. Next, place the power supply to the assembly board and fasten it by using the small screws on the sides of the board. 3

Charging operation 1. Ensure that the power supply is switched off and that the environment meets the conditions as described in the previous section. 2. Connect the output cables to the load / battery terminals: + cable to the + terminal and cable to the terminal Note: Do not cut the output cables. In case the cables are shortened, the output voltage is overcompensated as much as the loss of voltage drops in the cable. The overcompensation may cause voltage variations depending on the current consumption. 3. Turn the power on by turning the switch to position 1. 4. During normal power supply operation / charging process, the STATUS LED will light continuous o. 5. To avoid sparking, turn off the power supply before disconnecting the cables. DC Input connection The power supply input cable is connected as follows: L negative or positive DC supply input N positive or negative DC supply input PE protective earth (required ) The socket outlet shall be installed near the equipment and shall be easily accessible. Maximum 10A maximum rating of protective device required in building installation. When having unearthed DC mains 2 fuses or 2 pole circuit breaker required in building installation. Output voltage and current limit adjustment Trimmer or analog control adjustable modules, type example PAP800/24 or PAP800/24AI: The output voltage and output current limit of the power supply can be adjusted as follows: Trimmer adjustable models: with the multi-turn potentiometers accessible from the front panel. Analog controllable models by an external 0-5Cdc voltage. See detailed description Both voltage and current can be adjusted from zero to the maximum value. Maximum 800W output power is available within the adjustment. Temperature compensated models, type example PAP800/24T: LED The power supply includes 16 pre-programmed output voltages that are set by the code switch. See the setting table for this unit. Any of these 16 different voltage settings can be taken in use and additionally be adjusted within ±5% using the trimmer on the front panel. See the instructions for choosing the programmed voltage and the fine-tune adjustment. An o LED indicates a healthy power supply output voltage. Overcurrent protection The output of the power supply is protected against overcurrents and short circuits by an automatic, self-resetting electronic current limiter. Series/parallel connection Parallel operation: No restrictions, passive load sharing Series operation: Up to 500V total voltage Warning Dangerous voltages, capable of causing death are present in the power supply. Do not remove the cover. There are no operator serviceable parts inside the unit. Refer servicing to qualified service personnel only. 4

Option selection table Device have output connectors J8, J5 and J6 for option purposes. Some of the options are alternative and can not be assembled together. Columns in following table show which options can be assembled same time and the correct option character. Code-switch C C C C C Field Presettable F F F Analog control M M M Temperature measurement T T T Sense S S S S S S S S S S External LED L L L L L L L L L L L Bus OUT O 6 O O O Bus IN 6 I Relay R R R Relay steered by processor D D D Modular connectors J1 J8 J5 J6 Front panel J1 Analog input 0 5Vdc. Option: M Rear panel J8 Options: O, R, D, 6 J5 Options: T, S, I J6 Option: L Alarm relay models On models with an alarm relay, the alarm relay output indicates whether the output voltage is healthy or not. The alarm signal is activated in case of an AC failure or charger failure. Both normally closed signals and normally open contacts are available. Pin configuration, modular connector J8 with alarm relay option 1 2 3 4 Jack pin 3 Jack pin 1 NC COMMON Cable Black = common Red = NO Green = NC Jack pin 2 Common is connected to NC when the power is switched off. Common is connected to NO when the power is switched on. NO Relay Isolation: Output to case: 500V Output to gnd: 1V Technical data: 1A@24Vdc 0,5A@1Vac 5

Analog control and master slave connection The optional analog control allows full control of the output current and voltages and it provides the measured values for both of these. A +5V supply power is available for the supply of the control logic. The analog input has an isolation value of 500 V towards the input and output of the power supply. The master slave bus cables are connected from the master unit to the slave units as shown in the picture. Analog input modular connector 6 5 4 3 2 1 Pin configuration 1. Ground 2. Current control input 3. Voltage control input 4. Measured current value 5. Measured voltage value 6. +5V (max ma) output Pin configuration of the modular connector J1 The analog control card is connected via an AMP Modular 6 connector. Master slave connections. The first unit must be used as master unit. The number of slaves is unlimited. Controlling the analog card All control voltages must be between 0 and +5V, Higher voltages are not allowed. The control logic is positive, so that a +5V control voltage gives a maximum value from the power supply, while 0V means minimum output. As soon the control connector is unplugged from the modular connector, the power supply is reset to the minimum output values. The measured values can be read from the measurement signals. The measured values are scaled equal to the target values. If the power supply is set to the voltage reference, the measured value must be equal to the target. The same counts for the current control and its measured value. Measured signals (both together) can be loaded with max ma; otherwise proper operation cannot be guaranteed. The modular connector is isolated from the input, output and enclosure of the power supply. This enables the possibility to parallel or series connect several power supplies maintaining equal voltages. The number of connected devices is not limited. The 500V insulation voltage may, however, not be exceeded. This manual cannot be applied in case the connector of the analog card differs from a modular connector (9-pin D-connector). In that case it is an incompatible analog controlled power supply. Connecting example using the internal +5Vdc supply and external potentiometers. The +5V can be used as a supply for external circuits. The circuit given to the left, lets the power supply operate as a potentiometer controlled device. It is important to keep in mind that the +5V output may not be loaded more than ma, otherwise proper operation cannot be guaranteed. KP014_00328_008.odt 6