Revision Date: 1 Nov 2017 LMS-Platinum
LMS-Platinum Electronic Hotel Lock The LMS-Platinum represents the latest development in keyless electronic lock systems, offering accommodation providers a versatile, reliable and technologically advanced solution for customer and staff access. Available in Stainless Steel or Brass finish, this latest offering from KAS is modern, secure and features solid stainless steel construction for long lasting durability. This lock has also met the Australian Standards certification requirements for fire rated doors Mifare card RFID access type Stainless steel door furniture Automatic locking (5 secs after ingress) Deadlatch from the front, free passage from the inside Fire rated to Australian Standards AS-1905.1-2005 / AS-1530.4-1997 / AS-1530.4-1990. 2 year warranty Door hardware and lock software Architectural Hardware Battery powered 3 x AA with low voltage tone Mechanical override keys - 2 supplied per lock Neatly concealed barrel under the front lock face, no pins or disruptive covers Material List Front/rear lock body: Stainless steel Latch bolt: Deadlatch pin: Stainless steel 304 Stainless steel 304 Tubular Latch (TL) Heavy duty stainless steel tubular latch 304 construction Mortise Latch (ML) Heavy duty stainless steel mortise latch 304 construction Battery case: PVC Backsets available: Backset 70mm Handle: Zinc alloy die cast stainless finish 60, 70 or 127mm Fire rated mortise latch Card induction area: PVC Fire rated (up to 4 hours*) Virtual privacy snib 2 COPYRIGHT: Information in this document is subject to change without further notice. No part of this document may not be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the expressed written permission of KAS.
Hotel Lock Software Platinum Software Features User-friendly software KAS individually customise the software to your specific needs and requirements. Depending on your accommodation setup and personal preferences, certain features can be activated or deactivated as required. Full access and card programming privileges are available for managers and owners Basic card programming access levels are available for staff, guests and visitors. Common areas, access gates, car parks and gymnasiums can be made available or be personalised for selected guests. Place card here to encode Restrict or allow access to specific rooms. You can deny access temporarily and effortlessly to any lock at any time. Additional software control features: Restrict time period for staff card access Download room unlocking records reports in.xls format Setting Mifare card sector, integrating with other Mifare systems (upon request) Assign staff software logins controlled by Admin password Restrict staff login access (only program rooms) Automated time access to specific entry points System Programming Tools USB port at rear LCD screen Infrared induction area Mifare card encoder - simple connections via USB COM Port and each card can be encoded in seconds (~1 seconds per card) Lift Control System - assign specific lift floor levels to each key card. Assign a floor level that does not need card access (i.e Gym, Pool) Mifare cards/fobs can be re-encoded again and again. Additional cards/fobs can be purchased. Easy room occupancy tracking - tidy graphical layout of vacant/occupied room ratio. Change to free passage by a specific card from the software. Review the last 512 entries on each lock for security and auditing purposes. Data can be downloaded using the Mobile Programmer. Programming device connection port Mifare USB card encoder USB COM port plug and play Powered by USB port Programs all system cards 1 supplied per system Material: PVC All cables supplied 3 Encoder and PC connection port Mobile Progammer Hand held Mobile Programmer 1 supplied per system (additional devices available) Assigns room number to lock Reads unlocking records Reads battery remaining percentage LCD screen, power by 3 x AAA batteries (supplied) Material: PVC All cables supplied System requirements Windows 8 or higher Software installed remotely by KAS (TeamViewer) Software training session provided by KAS (1-2 hours) Basic tips and card issuing guides will be provided in this session
Technical Documentation Power Supply: Door Thickness: Static Power Supply: Dynamic Power Supply: Life time of battery: RFID Card Type: Working Temperature: Unlocking records: Fire rating: DC4.5V, 3 x AA batteries with low voltage alarm 35mm-57mm <10u A. <150mA. Long battery life - Approx 8000 unlocking uses Mifare Classic 1K S50 13.56MHz -20~+55degrees Audit trail records last 512 unlocking records Up to 4 hours fire rating* (AS1905/AS1530) Brass finish Stainless steel finish 70 Door Furniture Dimensions Tubular Latch Model (TL-70) KAS CARD 26 4 12 271 KAS 56 o 23 70 70 114 *All dimensions in mm 4
Hotel Access Accessories Energy Saving Device The ESD-950 has two relay switches. The first relay will allow power to the lights and normal electrical circuits while the guest card is installed inside the ESD reader. The second relay will only allow the air conditioning system to operate if both of the following criteria are met: 1. The guest card is inserted inside the reader, and 2. The door(s) and/or window(s) are fully closed - as connected to the installed door and/or window reed switches ESD-950 Voltage nominal 10A (Max. peak 16A) 220-240V-50Hz Egress time delay: 15 seconds Colour: white Operating temp: -10 / + 60 degrees Dimensions: W86mm x H86mm x D46mm Door/window reed switch Upon vacating the room and taking your guest card with you, all power to the lights, electrical circuits and air conditioning system (except for the fridge) will be turned off. Access Control System Access Control Reader (ACR) Access Control Module (ACM) Card induction area 12V DC power supply How access control readers and electric strikes work? A - Access Control Reader B - Internal request to exit button C - Electric striker A C B Access control systems are hardwired controls designed for high traffic areas such as main entrances, gyms, pools, car parks etc. Allowing customised controlled access to any entry point. This system can also be used for 'Lift call' meaning only valid card holders can retrieve the elevator. All floors are selectable from inside the elevator. The lift control system can increased energy savings, security and safety of your staff and guests. This allows only valid card holders access to their specific or pre-selected floors only. The LCM is installed into the existing lift hardware. Full user and installation instructions supplied. 5
COPYRIGHT: Information in this document is subject to change without further notice. No part of this document may not be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the expressed written permission of KAS.