DIN contacts interface

Similar documents
MyHOME. automation. DIN contacts interface F428

Control/actuator AM5851M2 H4671M2 LN4671M2

My Home AUTOMATION GUIDE

2-module actuator control with neutral AM5852M2 H/LN4672M

Touch control HD4657M3 HD4657M4 HC4657M3 HC4657M4 HS4657M3 HS4657M4

SCS-SCS gateway TECHNICAL SHEET OUT

2 WIRE video door entry system

MH201. Software Manual.

Front view. Internal view. Legend

05/16-01 PC Monobloc Audio Digital Entrance Panel. Installer manual

Lighting control for commercial buildings

SCS/SCS gateway F422

HOMETOUCH HOMETOUCH flush mounted box Additional power supply. Rear view

2 WIRE Video Door Entry system

1/6 SINGLE-FAMILY KIT WITH QUADRA AND MAXI. SB SYSTEM AWARDS KIT VIDEO QUADRA DOOR ENTRY SYSTEMS OVERVIEW HFX-9000M

D45 System. Digital colour entrance panel with addresses list

My Home - comfort. Dimmer for electronic transformers. Touch Screen

D45 System. 7 touch screen handsfree internal unit. Front & side views

eelecta & new products

Sfera Keypad Module. Installer manual 07/12-01 PC

4-channel 0 (1) to 10V output dimmer controller for Velbus system

Manual and application description 4 channel 0-10V dimmer V2.0

Din Rail 4 Output Module BO04A01KNX

1/5 SING.-FMLY KIT W/VANDALCOM & PC INTERCOM VIP SYST. KIT H.264 OVERVIEW 8504H

Arteor TM Radio/ZigBee

LED DALI Sequencer - User Manual

EN TECHNICAL MANUAL. ViP Mini hands-free monitor art. 6721W. Passion.Technology.Design.

Pneumatic Control Unit for the integrated mounting on process valves

H2C Motor Timers will be Discontinued March 2013; Replace with H3CR-A8E Solid-state Timer

DIN RAIL 12/8/4 OUTPUT MODULE. BOxxB01KNX. Product Handbook

Temperature control unit

Operating and Installation Instructions GePro Pushbutton KNX4 Frontlight- / Backlight 1 -KNX

EN TECHNICAL MANUAL. Icona door entry monitor Art. 6601W - Art. 6601W/BM. Passion.Technology.Design.

DESIGN SOLUTIONS FOR HOME AUTOMATION

XPSMCMMX inputs 2 output pairs expansion module with screw term

KNX S-B2-UP. Actuator for 230 V or 24 V. Installation and Adjustment

Manual and application description KNX/EIB LED driver V2.0

Safety System CES-FD. Non-contact safety system CES-FD- Direct connection to decentralized peripheral systems (e.g. ET200pro) PLC

KNX S-B4T-UP. Actuator for 230 V or 24 V. Installation and Adjustment

Logosol Supervisor I/O Controller CNC-SK-2310g2

Safety Monitoring Relays

Motorised actuator 0-10V EAC

iridium for HDL-BUS Pro

Din Rail Universal Module 8 inputs / 8 outputs IO88E01KNX

Video Display Eteris. Installation manual 01GF-28W10

Vandal-resistant entrance panel

Vandal-resistant entrance panel. Installer manual RA00054AA_I_EN01PC-12W16

EN TECHNICAL MANUAL. Mini door entry monitor with handset Art / Passion.Technology.Design.

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors

Installation and User Guide

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

DLB1248 single channel EASY-BLE

L4561N Stereo Control. Installation manual.

NON-PROGRAMMABLE ON DELAY, INTERVAL, TRUE OFF DELAY & FLASHER

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

170 ADI VDC - 16 Pt. Discrete Input Module Base

SC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. (407) Phone: Website:

Control Buttons / Switches for Panel Mounting Series 8003

MyHOMEServer1. Installation Manual.

Surface-Mounting Product Ranges

MA /2015. User manual CU-DIN DRY 4-Z KNX EC

KNX IP BAOS 772 ETS Application with building structure Technical Documentation

CLASSE 300 THE CONNECTED VIDEO INTERNAL UNIT

XPSMCMDI Input expansion module with screw term

4 CHANNEL UNIVERSAL DIMMING ACTUATOR

RFID/Digital Access Control Keypad

Deseo KNX Manual. Deseo KNX. Manual. basalte bvba hundelgemsesteenweg 1a 9820 merelbeke belgium. 1 / 65 v basalte

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

Brief description. Type overview

DALI Sequencer. Datasheet. Control Module. DALI-control unit for automatic retrieval of sequences

A quick look at the operations of the Matrix Programmable Controller by

Wireless Control Systems

Phone: Fax: Web: -

K-PO K-100 INSTRUCTION MANUAL

STEP MOTOR DRIVER SMD-4.2DIN

Overvoltage Protection

EDIFICIOS INTELIGENTES Y MULTIMEDIA: DOMOTICA Y CABLEADO ESTRUCTURADO

DT-RLC. User Manual. Lock/Light Control Interface

RS485 MODBUS Module 6RO

Structure of the device. Push-button sensor module. Ref.-no.: 4008 TSM Safety instructions

PRODUCT CATALOGUE

Din Rail 8 Input / 8 Output Module

Analog Modules AS-i, IP67, M12

Control Head for the integrated mounting on process valves

Digital Modules AS-i in IP20, 22,5 mm

XPSMCMDO Digital output pairs expansion modules with screw term

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

An OR Operation. Or (O) Function I0.4 Q0.1 I0.5 I0.5 I0.4 Q0.1. Input 3. Input 4. Output 2

Description. Installation. Power supply

Multi Voltage Options. Multi Voltage Options 110VAC + 24VAC/DC 230VAC + 24VAC/DC 24VAC/DC 110VAC 230VAC

Product and functional description

SMARTSCAN INFORMATION

ABB i-bus KNX. Room Solutions. ABB STOTZ-KONTAKT GmbH - 2CDC N0202, page 1

M A C 3 Wind Speed Alarm & Controller

Tebis application software

O N E - C H A N N E L R A D I O R E C E I V E R. 35 remotes DTM433MHz series, (MULTI version also other producers remotes) 433,92MHz OOK modulation

Copyright 2011 Rockwell Automation, Inc. All rights reserved. Next Generation Guardmaster Safety Relay Platform Overview

DRAG 2. Manual Instruction

8-channel pushbutton module. Velbus team

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

Transcription:

DIN contacts interface F428 Description This devices let you integrate traditional control devices (switches, pushbuttons, etc.) in advanced systems with BUS operating logic. Therefore, it is possible to extend the use of the Lighting Management system in rooms where traditional systems are already present or in historic and prestigious rooms whereby the complete or partial remaking of the electric system would entail heavy masonry work. The old but valuable switch with its no longer compliant wiring can therefore continue to be used with it, as the connection to the load to be controlled is carried out safely by connecting it with its SCS interface with novoltage contact. Contact controls light point PL1, contact controls light point PL2. The device is ted with 2 LEDs for the cations of contact closure, programming/ deletion, and the status of the control devices. The device may be installed in a MY HOME system and can be c red both physically and virtually, or as a component of the Lighting Management system, using c ration procedures (Plug&go, Project&Download). Technical data 5 4 C F428 1 2 Power supply from SCS BUS: 27 Vdc Operating power supply with SCS BUS: 18 27 Vdc Absorption: 9 ma Dissipated power with max. load: 0.2 W 3 Dimensional data Size: 2 DIN modules MY HOME c ration When installed in a MY HOME system, the device may be c red in two ways: PHYSICAL CONFIGURATION, by connecting the physical c rators to their sockets. VIRTUAL CONFIGURATION, by connecting the system to the PC using the 3503N Kit or the web server. The Virtual c rator software must be installed on the PC. Legend 1. Clamps for connection to traditional devices 2. C rator socket (attention, it must only be used in MY HOME systems with physical c 3. BUS 4. LED 5. Key ration).

Physic ation A PL1PL2 M SPE The interface includes two independent central units, iden with positions and. The two units can send: Controls to two actuators for two independent loads (ON, OFF or adjustment) iden with the addr or; A control to the scenario module item F420; A double control intended for a single load (motor for rolling shutter UP/DOWN, OPENCLOSE curtains) iden with the address PL1 = PL2 and mode M. The interface has two LEDs to signal correct operation and three clamps to connect to traditional devices such as: Two traditional NO (normally open) and NC (normally closed) switches or pushbuttons; A twoway switch. The interface also has a pushbutton to enable virtual c ration 1) SPE=0 mode Standard functions Automation Possible function Value c rator in M single function double function Cyclical ON/OFF with short pressure and adjustment with long pressure _ ON ON _ ON timed ) 1 8 _ OFF OFF _ OFF pressing the key connected to ON pressing the key connected to and adjustment with long pressure (dimmer) 2) _ 0/1 UP/DOWN rolling shutter to end of stroke _ UP/DOWN rolling shutter monostable _ M Pushbutton PUL the table below. C rator Time (minutes) 1 1 2 2 3 3 4 4 5 5 6 15 7 30 sec. 8 0.5 sec. (2) As a function of the receiver actuator operating mode. NOTE: If circuits are connected to the interface clamps, the operating mode to select is PUL. If normally open (NO) pushbuttons are connected all the other operating modes indicated in the table are performed.

2) Operating mode with C rator in M and SPE Possible function Value c rator in SPE single function Value c Locks the status of the devices to which the control is addressed 1 1 Unlocks the status of the devices to which the control is addressed 1 2 Unlocks with key connected to and locks with key connected to 1 3 1) 2 none 9 ON (key in ) OFF (jkey in ) without adjustment 1 0/1 Cyclical ON/OFF without adjustment (only NO contact) 1 7 2) 3 1 9 Call the scenarios of module F420 4 See table (3) Management of scenario module item F420 3) 6 See table (3) Timed ON (2 sec.) 8 1 Timed ON (10 min.) 8 2 rator in M double function (1) Device to be combined with an OFF control for switching OFF. C rator Time (sec.) none 0.5 1 1 2 1.5 3 2 4 2.5 5 3 6 3.5 7 4 8 4.5 9 5 (2) Device to be combined with the dimmer actuator and an OFF control for switching OFF. (3) With SPE=4 it is only possible to recall the scenario saved in the F420 module; 3) With SPE=6 it is possible to recall and program the scenarios saved in the F420 module. M=18: group of scenarios to be controlled: M First contact () Second contact () 1 1 2 2 3 4 3 5 6 4 7 8 5 9 10 6 11 12 7 13 14 8 15 16 A=0 to 9 and PL1=1 to 9 are the room and the light point of the scenario module to be controlled. C rator N % P of load 1 10 2 20 3 30 4 40 5 50 6 60 7 70 8 80 9 90

Scenario programmer: in order to program, change or cancel a scenario, it is necessary to enable the programming mode of the Module item F420 so that the status LED is green (press the lock/unlock key on the Scenario Module for at least 0.5 seconds); continue with the following operations: 1) press one of the four control keys the scenario should be associated to for 3 seconds. 4) To change or create new scenarios to be linked to the other keys, repeat the procedure starting from point 1. To call a set scenario just press its pushbutton on the control quickly. To completely delete a scenario, press the corresponding key for 10 seconds. 2) set the scenario using the corresponding controls for the various Automation, Temperature control, Sound system, etc. functions; programming mode; 3) Mode with SPE = 7 Automation standard functions normally closed contact This mode can perform the controls envisaged by the Basic operating mode with SPE = 0 when NC pushbuttons or switches are connected to the interface clamps. 4) Mode with SPE = 5 Sound system M=0: ON/OFF mode contact: With short pressure the following sequence is sent: PL2=0, source 1 is turned on (followme mode). With extended pressure the following happens: OFF For AMB or GEN controls, only the volume is adjusted. contact: With an extended pressure the volume is adjusted (VOL ). M=1 Source cycling/track cycling mode contact: cycle source contact: cycle track In this operating mode: Room control: General type controls: A = GEN for PL1=PL2=0 general controls In this operating mode: Pointpoint control: Room control: A = AMB General control: A = GEN PL1 = 0 followme mode is activated.

Vir ation Lighting Management c ration Using the Virtual C rator software it is possible to perform all the functions listed below: contact; single light control; single disable control; single scenario control; single CEN control; single scenario PLUS control; single CEN PLUS control; single AUX control. When installed in a Lighting Management system, the device can be c following ways: Plug&Go (see the dedicated technical guide) Project&Download, red in the Using the Virtual C rator software it is possible to perform all the functions listed below: contact; single light control; single disable control; single scenario control; single CEN control; single scenario PLUS control; single CEN PLUS control; single AUX control. Wiring diagram DIN module interface Acuator M C 1 2 3 4 1 3 2 4 ART. F428 ART. F430/2 C1 C2 SCS BUS L N 5